Roger Access Control System
MCT12M Installation Manual
Firmware version: x.1.30.266 and higher
Document version: Rev. B
This document contains minimum information that is necessary for initial setup
and installation of the device. The detailed description of configuration
parameters and functionalities is specified in respective Operating Manual
available at www.roger.pl.
INTRODUCTION
The reader is designed for operation with MC16 access controller (RACS 5
system). Factory new reader is configured with default settings including ID=100
address.
DEVICE CONFIGURATION
The reader can be configured in regard of various parameters (including
address) in order to adapt it to the requirements of specific installation. Device
can be configured from VISO v2 management software or RogerVDM utility
software.
Note: Remote configuration of device from VISO v2 software is possible only if
jumper is placed on MEM contacts (fig. 3). If the jumper is removed then such
configuration is blocked. In case of factory new device, jumper is placed on MEM
contacts.
CONFIGURATION WITH VISO V2PROGRAM
In RACS 5 v2 system the reader can be installed at site without previous
configuration. According to AN006 application note, its address and other
settings can be configured from VISO v2 management software and during such
configuration the access to its service contacts (fig. 3) is not required.
CONFIGURATION WITH ROGERVDM PROGRAM
Fig. 1 Connection of MCT reader to RUD-1 interface (configuration)
Programming procedure:
1. Connect the device to RUD-1 interface (fig. 1) and connect the RUD-1 to
computer’s USB port.
2. Remove jumper from MEM contacts (fig. 3) if it is placed there.
3. Restart the device (switch power supply off and on or short RST contacts for
a moment) and orange LED SYSTEM will pulsate. Then within 5 seconds
place jumper on MEM contacts.
4. Start RogerVDM program, select MCT device, firmware version, RS485
communication channel and serial port with RUD-1 interface.
5. Click Connect, the program will establish connection and will automatically
display Configuration tab.
6. Enter unoccupied RS485 address in range of 100-115 and other settings
according to requirements of specific installation.
7. Click Send to Device to update the configuration of device.
8. Optionally make a backup by clicking Send to File… and saving settings to
file on disk.
9. Disconnect from RUD-1 interface and leave jumper on MEM contacts to
enable further configuration of device from VISO v2 software or remove
jumper from MEM contacts to block such remote configuration.
Note: Do not read any cards nor press reader keypad when reader is configured
with RogerVDM.
MANUAL ADDRESSING
Manual addressing procedure enables configuration of new RS485 address with
all other settings unchanged.
Manual addressing procedure:
1. Remove all connections from A and B lines.
2. Remove jumper from MEM contacts (fig. 3) if it is placed there.
3. Restart the device (switch power supply off and on or short RST contacts for
a moment) and orange LED SYSTEM will pulsate. Then within 5 seconds
place jumper on MEM contacts.
4. Enter 3 digits of RS485 address in range of 100-115 with keypad or with any
MIFARE card.
5. Leave jumper on MEM contacts to enable further configuration of device from
VISO v2 software or remove jumper from MEM contacts to block such remote
configuration.
6. Restart the device.
Readers without keypad can be addressed with multiple card readings where the
N number of readings emulates digit of the address. Three series of readings
with any MIFARE proximity card are necessary to set the address. After each
series wait for two beeps and proceed with the next digit. Zero digit is emulated
with 10 readings.
Example:
Programming of ID=101 address with card readings:
1. Read card 1 time and wait for two beeps.
2. Read card 10 times and wait for two beeps.
3. Read card 1 time and wait for two beeps.
4. Wait till reader is restarted with the new address.
MEMORY RESET
Memory reset procedure resets all settings to factory default ones including
ID=100 address.
Memory reset procedure:
1. Remove all connections from A and B lines.
2. Remove jumper from MEM contacts (fig. 3) if it is placed there.
3. Restart the device (switch power supply off and on or short RST contacts for
a moment) and orange LED SYSTEM will pulsate. Then within 5 seconds
place jumper on MEM contacts.
4. Press [*] or read any MIFARE card 11 times.
5. Wait till device confirms reset with long acoustic signal.
6. Leave jumper on MEM contacts to enable further configuration of device from
VISO v2 software or remove jumper from MEM contacts to block such remote
configuration.
7. Restart the device.
FIRMWARE UPDATE
The firmware of device can be changed to newer or older version. The update
requires connection to computer with RUD-1 interface (fig. 2) and starting
RogerVDM software. The latest firmware file is available at www.roger.pl.
Firmware update procedure:
1. Connect the device to RUD-1 interface (fig. 2) and connect the RUD-1 to
computer’s USB port.
2. Place jumper on FDM contacts (fig. 3).
3. Restart the device (switch power supply off and on or short RST contacts for
a moment).
4. Start RogerVDM program and in the top menu select Tools and then Update
firmware.
5. In the opened window select device type, serial port with RUD-1 interface
and path to firmware file (*.hex).
6. Click Update to start firmware upload with progress bar in the bottom.
7. When the update is finished, disconnect from RUD-1 interface and remove
jumper from FDM contacts. Additionally it is recommended to start memory
reset procedure.
Fig. 2 Connection of MCT reader to RUD-1 interface (firmware update)
2/2
APPENDIX
Fig. 3 Service contacts
Table 1. Wires
Name
Wire colour
(MCT12M-IO)
Wire colour
(MCT12M)
Description
12V
Red
Red
Supply plus
GND
Black
Black
Ground
A
Yellow
Yellow
RS485 bus, line A
B
Green
Green
RS485 bus, line B
IN1
Brown
IN1 input line
IN2
Blue
IN2 input line
IN3
Grey
IN3 input line
IO1
White
IO1 output line
IO2
Violet
IO2 output line
NC
Grey-pink
REL1 relay output (NC)
COM
Red-blue
REL1 relay common
terminal
NO
Pink
REL1 relay output (NO)
Table 2. Specification
Supply voltage
Nominal 12VDC, min./max. range 10-15VDC
Current consumption
(average)
MCT12M-BK/MCT12M-BK-IO/
MCT12M-BK-DES-IO: ~65 mA
MCT12M/MCT12M-IO/
MCT12M-DES-IO: ~85 mA
Inputs
Three parametric inputs (IN1..IN3) internally
connected to the power supply plus through a
5.6kΩ resistor. Approx. 3.5V triggering level for
NO and NC inputs.
Relay output
Relay output (REL1) with single NO/NC contact,
30V/1.5A DC/AC max. load
Transistor outputs
Two (IO1, IO2) open collector outputs, 15VDC/1A
max. load
Tamper protection
Enclosure opening reported to access controller
Proximity cards
MCT12M-DES-IO/MCT12M-BK-DES-IO:
13.56MHz MIFARE Ultralight, Classic,
DESFire EV1 and Plus
Remaining MCT12M readers:
13.56MHz MIFARE Ultralight, Classic
Reading range
Up to 7 cm for MIFARE Ultralight, Classic
Up to 4 cm for MIFARE DESFire EV1, Plus
Distance
1200m maximal cable length for RS485 bus
between controller and reader
IP Code
IP65
Environmental class
(according to EN 50133-1)
Class IV, outdoor general conditions, temperature:
-25°C to +60°C, relative humidity: 10 to 95% (no
condensation)
Dimensions H x W x D
152,5 x 46 x 23(35) mm
Weight
~150g
Certificates
CE
Fig. 4 Connection of readers and expanders to MC16 access controller
Fig. 5 Connection of door lock, door contact and exit button to MCTxx-IO reader
This symbol placed on a product or packaging indicates that the
product should not be disposed of with other wastes as this may
have a negative impact on the environment and health. The user is
obliged to deliver equipment to the designated collection points of
electric and electronic waste. For detailed information on recycling,
contact your local authorities, waste disposal company or point of
purchase. Separate collection and recycling of this type of waste
contributes to the protection of the natural resources and is safe to
health and the environment. Weight of the equipment is specified in
the document.
Contact:
Roger Sp. z o. o. sp. k.
82-400 Sztum
Gościszewo 59
Tel.: +48 55 272 0132
Fax: +48 55 272 0133
Tech. support: +48 55 267 0126
E-mail: support@roger.pl
Web: www.roger.pl

Other manuals for MCT12M

2

Other Roger Control System manuals

Roger RUD-3-DES User manual

Roger

Roger RUD-3-DES User manual

Roger MCT62E User manual

Roger

Roger MCT62E User manual

Roger H70/104AC Product manual

Roger

Roger H70/104AC Product manual

Roger PRT12MF-DES User manual

Roger

Roger PRT12MF-DES User manual

Roger B73/LTM Product manual

Roger

Roger B73/LTM Product manual

Roger B70/2DC Product manual

Roger

Roger B70/2DC Product manual

Roger CPR32-SE v2.0 User manual

Roger

Roger CPR32-SE v2.0 User manual

Roger ASCD-1 User manual

Roger

Roger ASCD-1 User manual

Roger MC16-RAW-KIT User manual

Roger

Roger MC16-RAW-KIT User manual

Roger MC16-PAC-2-KIT User manual

Roger

Roger MC16-PAC-2-KIT User manual

Roger RKD32 User manual

Roger

Roger RKD32 User manual

Roger MCX16-UZ User manual

Roger

Roger MCX16-UZ User manual

Roger MCT12E User manual

Roger

Roger MCT12E User manual

Roger MCT80M-BLE User manual

Roger

Roger MCT80M-BLE User manual

Roger MCT62E User manual

Roger

Roger MCT62E User manual

Roger PR411DR-SET User manual

Roger

Roger PR411DR-SET User manual

Roger B71/BCHP HW02 Product manual

Roger

Roger B71/BCHP HW02 Product manual

Roger PSD4D User manual

Roger

Roger PSD4D User manual

Roger MCT88M-IO User manual

Roger

Roger MCT88M-IO User manual

Roger OSR88M-IO User manual

Roger

Roger OSR88M-IO User manual

Roger H85/TDR Product manual

Roger

Roger H85/TDR Product manual

Roger MC16-PAC-2-KIT User manual

Roger

Roger MC16-PAC-2-KIT User manual

Roger MCT80M User manual

Roger

Roger MCT80M User manual

Roger MCT82-FK User manual

Roger

Roger MCT82-FK User manual

Popular Control System manuals by other brands

Sel SEL-451-5 manual

Sel

Sel SEL-451-5 manual

BENDIXKing Skymap IIIC pilot's guide

BENDIXKing

BENDIXKing Skymap IIIC pilot's guide

Contro l4 Onyx user guide

Contro l4

Contro l4 Onyx user guide

Gema OptiFlex A1 Operating instructions and spare parts list

Gema

Gema OptiFlex A1 Operating instructions and spare parts list

Keyautomation 900CT-380 instructions

Keyautomation

Keyautomation 900CT-380 instructions

BM PRO OdysseyControl owner's manual

BM PRO

BM PRO OdysseyControl owner's manual

Fike Epaco user manual

Fike

Fike Epaco user manual

Vent-Axia Sentinel Installation operation & maintenance

Vent-Axia

Vent-Axia Sentinel Installation operation & maintenance

Keba KeContact Series System manual

Keba

Keba KeContact Series System manual

Velux Integra Kux 110 manual

Velux

Velux Integra Kux 110 manual

Vista LCS installation instructions

Vista

Vista LCS installation instructions

Balboa Instruments GS520DZ manual

Balboa Instruments

Balboa Instruments GS520DZ manual

SALUPO IMPEDANCE 1 SQ701. Series Instruction and installation manual

SALUPO

SALUPO IMPEDANCE 1 SQ701. Series Instruction and installation manual

Fagor 8070 BL Programming manual

Fagor

Fagor 8070 BL Programming manual

Ormazabal cgmcosmos-l General instructions

Ormazabal

Ormazabal cgmcosmos-l General instructions

Mitsubishi Electric M800VW Series Programming manual

Mitsubishi Electric

Mitsubishi Electric M800VW Series Programming manual

JUMO mTRON T System description

JUMO

JUMO mTRON T System description

Norac UC4.5 installation manual

Norac

Norac UC4.5 installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.