manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Salto
  6. •
  7. Lock
  8. •
  9. Salto Node User manual

Salto Node User manual

Other Salto Lock manuals

Salto Ei6***GD Series Operating and maintenance instructions

Salto

Salto Ei6***GD Series Operating and maintenance instructions

Salto Geo Padlock P3 User manual

Salto

Salto Geo Padlock P3 User manual

Salto Clay IQ User manual

Salto

Salto Clay IQ User manual

Salto SMILE Operating instructions

Salto

Salto SMILE Operating instructions

Salto LE7S 7 Series User manual

Salto

Salto LE7S 7 Series User manual

Salto GEO GxE1 Series User manual

Salto

Salto GEO GxE1 Series User manual

Salto A i 650 Series User manual

Salto

Salto A i 650 Series User manual

Salto XS4 Mini User manual

Salto

Salto XS4 Mini User manual

Salto Neo MIWA User manual

Salto

Salto Neo MIWA User manual

Salto XS4 Mini User manual

Salto

Salto XS4 Mini User manual

Salto XS4 Mini User manual

Salto

Salto XS4 Mini User manual

Salto Geo Cylinder GxE Series User manual

Salto

Salto Geo Cylinder GxE Series User manual

Salto XS4-Locker User manual

Salto

Salto XS4-Locker User manual

Salto XS4 Geo User manual

Salto

Salto XS4 Geo User manual

Salto XS4 Mini User manual

Salto

Salto XS4 Mini User manual

Salto Geo G P21 Series User manual

Salto

Salto Geo G P21 Series User manual

Salto KPB22 Series User manual

Salto

Salto KPB22 Series User manual

Salto Strike CEGD**IM series User manual

Salto

Salto Strike CEGD**IM series User manual

Salto XS4 Original+ E i 450 Series User manual

Salto

Salto XS4 Original+ E i 450 Series User manual

Salto Neo User manual

Salto

Salto Neo User manual

Salto Aelement User manual

Salto

Salto Aelement User manual

Salto Ei75 Series User manual

Salto

Salto Ei75 Series User manual

Salto Neoxx G4 User manual

Salto

Salto Neoxx G4 User manual

Salto LE7S Series User manual

Salto

Salto LE7S Series User manual

Popular Lock manuals by other brands

Magic 105 manual

Magic

Magic 105 manual

Gantner GAT NET.Lock 7020 System Installation, configuration & operation

Gantner

Gantner GAT NET.Lock 7020 System Installation, configuration & operation

Dorma Studio Classic Installation instruction

Dorma

Dorma Studio Classic Installation instruction

Securam ECSL-601 quick start guide

Securam

Securam ECSL-601 quick start guide

Sudhaus 3003 operating manual

Sudhaus

Sudhaus 3003 operating manual

Safety 1st 48517 user guide

Safety 1st

Safety 1st 48517 user guide

Pado FDS-10 user manual

Pado

Pado FDS-10 user manual

Esco systeQ Series installation instructions

Esco

Esco systeQ Series installation instructions

COMPX National D8951 instruction sheet

COMPX

COMPX National D8951 instruction sheet

secureo Key Box instruction manual

secureo

secureo Key Box instruction manual

Stock Loks C8713 instruction sheet

Stock Loks

Stock Loks C8713 instruction sheet

COMPX 1T-058 Information

COMPX

COMPX 1T-058 Information

Auslock T11 user manual

Auslock

Auslock T11 user manual

Stealth SAFES ShadowVault Instructions & Troubleshooting

Stealth SAFES

Stealth SAFES ShadowVault Instructions & Troubleshooting

Knox KeySecure 5 Admin & user guide

Knox

Knox KeySecure 5 Admin & user guide

Kwikset 48334/01 Quick installation guide

Kwikset

Kwikset 48334/01 Quick installation guide

Metra Electronics Door Access Terminal Combo Technical manual

Metra Electronics

Metra Electronics Door Access Terminal Combo Technical manual

Kilitronik miniK10m operating manual

Kilitronik

Kilitronik miniK10m operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Electrical characteristic Características eléctricas Caractéristiques électriques
All contents current at timeof publication.
SALTO Systems S.L. reserves the right to change availability of any
item in this catalog, its design, construction, and/or materials.
European view
Installation guide
SALTO Node
221136-ED.2 - 19/12/2022
©
2021 SALTO Systems S.L. 1/2
The SALTO Node is part of SALTO wireless system. It works as a bridge, with the
SALTO Gateway, between SALTO's access control software and wireless locks.
El SALTO Node forma parte del sistema wireless de SALTO. Actúa como
puente, junto con el SALTO Gateway, entre el software de control de acceso
de SALTO y las cerraduras wireless.
Le SALTO Node fait partie du système radio-fréquence SALTO. Il joue
le rôle de pont, avec le SALTO Gateway, entre le logiciel de contrôle
d'accès et les serrures radio-fréquence de SALTO.
SALTO´s Software
*RS485 Bus
*Power Supply
UTP CAT5e
*RS485 Bus
*Power Supply
UTP CAT5e
Up to 6 External RF Node
per SALTO Gateway
SALTO
Node
Up to 112 SALTO RFnet Lock per
SALTO Gateway (16 per SALTO Node)
Power
RS485 bus to Nodes
SALTO
Gateway
Eng
E
Operation conditions
Min Typ Max Unit
Temperature
-20 25 70
ºC
Humidity
35 85
RS485 Connection (AB) Generic twisted pair wire
Power Connection (Vdd)
24 AWG
Note 1
Cable requirements
Note 1: 1x2x24AWG or UTP CAT5e recommended
Nodes current consumption
2400-2483.5 Mhz
IEEE 802.15.4
Frequency Range
Standard
10/15m
Indoor Radio Range
71228V
mA
Imput Voltage
Current consumption
Min Typ Max Unit
Note 2
2400-2483.5Mhz
Bluetooth Low Energy
Frequency Range
RF Standard
5m/10m
Indoor Radio Range
5dBm
Max output power
SALTO BLUEnet Characteristics
SALTO RFnet Characteristics
8dBm
Max output power
Mechanical installation Instalación mecánica Installation mécanique
Eng
E
SALTO
Node
Note 2: Power supply must be calculated taking into account SALTO Gateway
and
71228V
mA
Imput Voltage
Current consumption
Min Typ Max Unit
Note 2
Power Supply for BLUENET
Power Supply for SALTO RFnet
75
45
83
(3-1/4")
20
(25/32")
34
(1-11/32")
83
(3-1/4")
1 GANG ELECTRICAL STANDARD BOX
1 MÓDULO CAJA ELÉCTRICA ESTANDARD
1 BOÎTIER ÉLECTRIQUE À BRANCHEMENTS STANDARD
F
F
Installation guide
Guía de instalación
Guide d'installation
Eng
E
F
All contents current at timeof publication.
SALTO Systems S.L. reserves the right to change availability of any
item in this catalog, its design, construction, and/or materials.
European view
Installation guide
SALTO Node
221136-ED.2 - 19/12/2022
©
2021 SALTO Systems S.L.
Electrical installation
Instalación eléctrica
Installation électrique
Eng
E
2/2
RS485 bus termination resistor is
needed (ON position) when the node
is located at the end of the bus.
La resistencia de terminación del bus
RS485 es necesaria (posición ON)
cuando el equipo esté situado en
uno de los extremos del bus.
Résistance de terminaison du bus
RS485 nécessaire (position ON)
quand le noeud se trouve à la fin du
bus.
Installation example
Ejemplo instalación
Exemple d'installation
Eng
E
SALTO Gateway
Up to 5/10m
to Node
RF Link
UTP CAT5e
1pair RS485
1pair 12v Power
20m max
UTP CAT5e 1pair RS485 1pair 12v Power
25m
(if internal node installed)
Signalling
Señalización Signalisation
Eng
E
Eng
E
The green (SALTO RFnet) or blue (SALTO BLUEnet) LED of the Node indicates that the Node is properly powered.
El LED en verde (SALTO RFnet) o azul (SALTO BLUEnet) indica que el Nodo está alimentado correctamente.
La LED verte (SALTO Rfnet) ou bleue (SALTO BLUEnet) du noeud indique que le noeud est correctement branché.
Eng
Operational test
Test operacional
Test de fonctionnement
Eng
E
Once the product is installed, follow these steps to check the correct operation:
- When SALTO Gateway and locks are installed, check that the RF Node is active in SALTO's software.
Una vez instalada la unidad de control, para comprobar el correcto funcionamiento de la instalación, siga los siguientes pasos:
- Comprobar que al instalar el SALTO Gateway y las cerraduras el nodo está activo en el software de SALTO.
Lorsque le produit est installé, suivez ces étapes pour vérifier le bon fonctionnement :
-
Lorsque le gateway et les serrures SALTOsont installés, vérifiez que le noeud RF est actif dans le logiciel de SALTO.
Maintenance
Mantenimiento
Maintenance
Eng
E
Eng
E
The unit should be tested at least once a year as described in "Operational test".
Keep the device in a safe place!
Es recomendable realizar un testeo operacional una vez al año siguiendo el "Test operacional".
¡Guarde el dispositivo en un lugar seguro!
L'unité doit être testée au moins une fois par an comme décrit dans « Test defonctionnement ».
Gardez le dispositif en lieu sûr!
SALTO Node SALTO Node SALTO Node SALTO Node SALTO Node SALTO Node
E
F
Eng
E
F
Eng
E
F
F
F
F
F
F
F
The environment has a direct impact on the BLUEnet range radiation (metal, concrete walls...)
The receiver device must be located facing the product antenna. Please check your product's BLUEnet antenna position.
Recommended connectivity distance: 5m - 10m
El entorno tiene un impacto directo sobre el rango de radiación de BLUEnet (metal, paredes de hormigón...)
El dispositivo receptor debe ubicarse frente a la antena del producto. Compruebe la posición de la antena BLUEnet de su dispositivo.
Distancia de conectividad recomendada: 5m - 10m
L’environnement a un impact direct sur le rayonnement de la gamme BLUEnet (métal, murs en béton …)
Le dispositif récepteur doit être placé face à l’antenne du produit. Veuillez vérifier la position de l’antenne BLUEnet du produit.
Distance de connectivité maximale : 5m – 10m
BLUEnet information Información BLUEnet BLUEnet information
Eng
E F
E
Eng
F