Singer SDHM-10L SMART ION User manual

SDHM-10L & SDHM-12L SMART ION
Dehumidifier
Αφυγραντήρας
Влагоабсорбатор
GB
INSTRUCTION MANUAL
GR
ΒΙΒΛΙΟ ΟΔΗΓΙΩΝ
BG
ИНСТРУКЦИИ ЗА ЕКСПЛОАТАЦИЯ R290

GB ENGLISH....................................... 3
GR EΛΛΗΝΙΚΑ .................................. 28
BG БЪЛГАРСКИ ............................... 58

3
ENGLISH
This product is using the Environment
friendly refrigerant R290. R290 has no
damaging influence on the ozone layer
(ODP), a negligible greenhouse effect (GWP)
and is available worldwide. This refrigerant
is tasteless and combustible, moreover,
it can burn and explode under certain
condition. Special precautions must be
taken into consideration before using and
maintenance of this appliance due to the
coolant's high flammability: so please read
this user manual carefully before using and
maintenance.
SYMBOLS FROM THE UNIT AND USER MANUAL
This unit uses a flammable refrigerant gas.
If refrigerant gas leaks and comes in contact
to fire or heating part, it will be created harmful
gas and there is risk of fire.
Read the USER MANUAL carefully before op-
eration and maintenance.
Further information is available in the USER
MANUAL and the SERVICE MANUAL.
Service personnel are required to carefully
read the USER and SERVICE MANUAL before
operation and maintenance.
Additional warning for appliance with R290 refrigerant gas
(refer to the rating plate for the type of refrigerant gas used).
R290 refrigerant gas complies with European environmental
directives.

4
ENGLISH
WARNINGS (FOR USING R290 REFRIGERANT ONLY)
Appliance shall be installed, operated and
stored in a room with a floor area larger than
4 m2.
This product needs to be in a room without
continuously operating ignition sources (for
example: open flames, an operating gas appli-
ance, an operating electric heater or stove with
open fire, etc.)
• Be aware that the refrigerants may not contain an odor.
• Do not pierce or burn.
• Do not use means to accelerate the defrosting process or to
clean, other than those recommended by the manufacturer.
• Compliance with national gas regulations shall be observed.
• Keep ventilation openings clear of obstruction.
• The appliance shall be stored so as to prevent mechanical
damage from occurring.
• A warning that the appliance shall be stored in a well-ventilat-
ed area where the room size corresponds to the room area as
specified for operation.
CAUTION: RISK OF FIRE
FLAMMABLE MATERIAL
READ THE MAΝUAL CAREFULLY
BEFORE USING THE APPLIANCE.
MAKE SURE TO SAVE THIS MANUAL
FOR FUTURE REFERENCE.

5
ENGLISH
• Any person who is involved with working on or breaking into a
refrigerant circuit should hold a current valid certificate from an
industry-accredited assessment authority, which authorizes
their competence to handle refrigerants safely in accordance
with an industry recognized assessment specification.
• Servicing shall only be performed as recommended by the
equipment manufacturer. Maintenance and repair requiring
the assistance of other skilled personnel shall be carried out
under the supervision of the person competent in the use of
flammable refrigerants.
IMPORTANT SAFETY INFORMATION
• Avoid installation behind a door.
• Use only with the supply voltage specified on the rating plate
of the Dehumidifier.
• Before installing, cleaning and servicing turn off the power and
unplug the unit.
• Do not place appliance close to a radiant heat source.
• Do not use the appliance near flammable gas of combustibles,
such as gasoline, bezene, thinner, etc.
• Do not immerse in liquid or allow liquid to run into the interior of
the appliance, as this could create an electrical shock hazard.
• Do not use this appliance on a wet surface, or where it can fall
or be pushed into water.
• Do not reach for an appliance that has fallen into water. Switch
off at supply and unplug immediately.
• Do not operate any appliance with a damaged cord, plug or
after the appliance malfunctions or has been dropped or dam-

6
ENGLISH
aged in any manner. Refer appliance to a qualified electrical
person for examination, electrical or mechanical adjustment,
service or repair before further use.
• Do not operate appliance with wet hands.
• This appliance is intended for indoor household use only and
not for commercial or industrial use.
• Use this appliance only as described in this manual. Any other
use is not recommended by the manufacturer and may cause
fire, electric shock or injury.
• Do not use this appliance in a window as rain may cause elec-
tric shock.
• Do not use abrasive cleaning products on this appliance. Wipe
with a soft cloth to clean the exterior. Always remove plug from
the mains supply before cleaning.
• Switch off the appliance before changing its position.
• Do not remove the power plug from the socket by pulling the
cord – grip the plug instead.
• Always unplug appliance when not in use.
• Do not run cord under carpeting, throw rugs or runners etc.
Arrange cord away from areas where it is likely to be tripped
over.
• Do not modify power cord length or share the outlet with other
appliances.
• Disconnect the power if strange sounds, smell or smoke
comes from it.
• Do not place heavy object on the power cord and take care so
that the cord is not compressed.
• This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabili-
ties, or lack of experience and knowledge, unless they have
been given supervision or instruction concerning use of the

7
ENGLISH
appliance by a person responsible for their safety.
• Young children should be supervised to ensure they do not
play with the appliance.
• If the supply cord is damaged, it must be replaced by a quali-
fied electrical person in order to avoid a hazard.
• Do not spray pesticides or flammable gas near the unit.
• Do not scrape the unit using sharp objects.
• Do not splash any oil or water into the unit.
• Install the unit on a flat, horizontal surface to avoid vibration
and noise.
• Do not put heavy objects on the appliance.
• Do not cover the intake or exhaust opening with cloths or tow-
els.
• Do not drink or use the water drained from the unit.
• Do not take the water tank out during operation.
• Empty the water tank before moving the unit to avoid water
spilling.
• Do not tilt the unit to prevent water from spilling and damaging
the machine.
• Do not insert or allow slim rods or other foreign objects to enter
any opening, as this may cause an electric shock, fire or dam-
age to the appliance.
• Never insert your finger or other foreign objects into grills or
openings. Take special care to warn children of these dangers.
• If any abnormal situations occur, immediately turn off the pow-
er supply.

8
ENGLISH
SERVICE & REPAIR
1. For service or repair under warranty, please contact the au-
thorized service company that is mentioned on the guarantee
card that accompanies the product.
2. Do not operate any product with a damaged cord or plug. If
the supply cord is damaged, return the appliance to a SINGER
service center for examination repair or adjustment. Do not at-
tempt to dismantle any part of the appliance. This should only
be done at an authorized SINGER service centre.
3. The partial or total non-respect of the safety instructions in the
present instruction manual will automatically release Singer of
any type of responsibility in case of malfunction of the machine
or injuries to persons or animals.
4. In case of manipulation, repairing or any modification of the
machine made by unqualified persons or in case of improper
use, the guarantee will be automatically cancelled.
PRODUCT DESCRIPTION
The dehumidifier is used to remove excessive moisture from the
air. The resulting reduction in relative humidity protects buildings
and their contents from the adverse effects of excess humidity.
Before Initiation
• To avoid any damage, place the unit in an upright position for
at least 24 hours before initiation.
• Make sure that the air outlet and air inlet are never blocked.
• Only operate the unit on a horizontal surface to ensure no wa-
ter leaks out.
• After removing the packaging, make sure that the appliance is
in good condition.
• Do not allow children to play with the packaging materials as
there is risk of suffocation.

9
ENGLISH
OVERVIEW
SPECIFICATIONS
MODEL No. SDHM-10L SMART ION SDHM-12L SMART ION
Dehumidify Capacity 10L/day (30ºC,80%) 12L/day (30ºC,80%)
Rated voltage/Frequency AC220-240V/50Hz AC220-240V/50Hz
Rated power input 200W (27°C 60%) 210W (27°C 60%)
Max. Input Power 245W (32°C 90%) 250W (32°C 90%)
Rated Input Current 1.25A (27°C 60%) 1.26A (27°C 60%)
Max. Input Current 1.40A (32°C 90%) 1.45A (32°C 90%)
Water Tank Capacity 2,2L 2,2L
Air volume 120m³/h 120m³/h
Noise Level ≤45dB(A) ≤45dB(A)
Refrigerant Charge R290/35(g) R290/45(g)
Product Dimensions (LxWxH) 280X240X460 280X240X460
Net Weight 9kg 10kg
Suction Side Pressure 1.2MPa 1.2MPa
Discharge Side Pressure 2.5MPa 2.5MPa
Power switch
Air outlet
Handle
Air inlet
Water tank
Front Back
ACTIVE CARBON FILTER
to filter air

10
ENGLISH
BEFORE FIRST USE
Install the unit in a convenient position as per the diagram shown below.
Notes:
• Before moving the unit, remove any water from the water tank.
• To save energy, keep windows and door closed when unit is running.
• Please install the unit on a flat horizontal surface.
minimum 20cm
minimum 20cm
minimum 20cm
minimum 20cm
minimum 20cm

11
ENGLISH
CONTROL PANEL
3-color Ambient humidity indicator on the inner part of the panel
BLUE color shows Ambient humidity <50%
GREEN color shows Ambient humidity between 50% and 70%
RED color shows Ambient humidity >70%
POWER: Press the POWER button to turn the unit on or off.
IONIZER
FUNCTION:
SETTING: Press the button to set the desired dehumidification degree (30%-
80%). The humidity can be set in 5% increments from 30, 35, 40,
45,…, 80.
MODE: Press the MODE button to select the mode of operation. Four dif-
ferent modes are possible:
1. ORDINARY DEHUMIDIFYING mode: Ordinary mode is the
default mode when the power is on and appliance operate un-
der default humidity 55% RH. Button lights up and the fan
The ionizer function will be on when unit turn on and off when
unit turn off.

12
ENGLISH
speed is low. Both
f
an speed and humidit
y
can be adjusted
u
n
d
er or
d
inary mo
d
e accor
d
in
g
to t
h
e environmental
h
umi
d
ity
.
2. L
O
W DEHUMIDIFYING mode
:
Press the M
O
DE button to
s
elect t
h
i
s
mo
d
e. Here, t
h
e unit alwa
y
s works wit
h
low
f
an speed
f
or an
y
room humidit
y
and the humidit
y
cannot be
ch
an
g
e
d.
3. HI
G
H DEH
U
MIDIFYIN
G
m
o
de
:
Press the MODE button once
to
s
elect t
h
i
s
mo
d
e. Here, t
h
e unit always works wit
h
h
i
gh
f
an speed
f
or an
y
room humidit
y
and the humidit
y
cannot be
ch
an
g
e
d
. T
h
e environmental
h
umi
d
ity can
b
e s
h
own on t
h
e
pane
l.
4.
C
ontinuous (clothes dryin
g
) mode
:
Pre
ss
t
h
i
s
b
utton
to
switc
h
to continuous clot
h
es
d
ryin
g
mo
d
e
.
There will be hi
g
h
f
an speed under this mode and the humidity
c
annot
b
e c
h
an
g
e
d
. T
h
e environmental
h
umi
d
ity can
b
e s
h
own
o
n t
h
e panel
.
FAN:
Pre
ss
t
h
e FAN
b
utton to
s
elect t
h
i
s
mo
d
e. You can
s
witc
h
to low
o
r hi
g
h
f
an speed by pressin
g
the FAN button a
g
ain
.
TIMER:
Press the button to determine off or on time
(
0-24h
)
Settin
g
of timed shutdown
Under the operation status o
f
the machine, press the [Timer] ke
y
to adjust the time
f
rom 1 hour to 24 hours. Each press will in
-
c
rease the set time by one hour and a
f
ter 24 hours, the
fi
g
ure
w
ill return to 1
f
or another circulation. User could also lon
g
press
the
[
Timer
]
ke
y
and the time increases in rotation. When the set
time is due, the machine will be shut down automaticall
y
. A
f
ter the
settin
g
, i
f
there’s no action on the [Timer] key within 5 seconds, it
means the timin
g
has been con
fi
rmed. Under the timed shutdown
status, the key li
g
ht above the
[
Timer
]
is on
.

13
ENGLISH
Setting of the timed startup
Under the standby status of the machine, the way to adjust the
time is the same as that of the timed shutdown. After the setting,
if there is no action on the [Timer] key within 5 seconds, it means
the timing has been confirmed. Under the timed startup status,
the key light above the [Timer] is on and the control screen dis-
plays the set time.
CHILD LOCK:
Keep the button pressed to lock or unlock all the keys.
• Press and hold LOCK button for more than 3sec to lock all the
control panel buttons.
• Press and hold LOCK button again for more than 3sec to unlock
all the control panel buttons.
AIR CLEAN: By pressing this button only AIR FILTER mode is in operation.
Under this mode Dehumidification does not operate. Fan and
Timer are effective.
SLEEP MODE:
Press this button, the button lights up and the Sleep mode turns
on. All indications become dark. Touch any button to activate the
display. Touch the Sleep button again to exit this mode.
Clothes drying: Place the unit in a room with closed doors along with
the clothes rack and switch on the appliance by pressing the Con-
tinuous (clothes drying) mode button.

14
ENGLISH
LED DISPLAY
Ordinary Dehumidifying mode
Low Dehumidifying mode
High Dehumidifying mode
Continuous (clothes drying) mode
Room Humidity, when the SETTING button is pressed the Set Hu-
midity is displayed
Timer hours
Water Tank full/ Water Tank not placed correctly
Auto defrost function- Low temperature work

15
ENGLISH
WATER TANK INDICATOR
When the water tank is full for 5 seconds, the indicator light shows red, the
buzzer will warn for 20 times and the compressor will stop automatically. At this
time, empty the water tank and put it back to correct position.
EMPTY THE TANK
●Grab the notch at the side of the tank and pull it out with both hands.
Take it slowly and steadily in case of spilled water.
●Empty the water.
●Put the water tank back in position. The dehumidifier automatically starts
working again.
AUTO DEFROST-LOW TEMPERATURE WORK
Dehumidifier may defrost automatically if it is operated in room temperature
less than ≤23℃.
Defrosting function may start up and operate for some time (about 5 minutes)
automatically every 25 minutes or even longer according to room temperature:
• 18℃< temperature ≤23℃; the machine will automatically defrost every 120
minutes. The power indicator will flash continuously, and the fan will keep
working at high speed.
• 12℃< temperature ≤18℃the machine will automatically defrost every 25
minutes. The power indicator will flash continuously, and the fan will keep
working at high speed.
• 5℃< temperature ≤12℃the machine will automatically defrost every 20
minutes. The power indicator will flash continuously, and the fan will keep
working at high speed.
• During the defrosting operation, the dehumidification function and air purifica-
tion function may intermit

16
ENGLISH
• Please do not turn off the intermit or pull out the power plug during the de-
frosting operation.
MAINTENANCE
CAUTIONS
1. Do not remove the float in the water tank, otherwise, the machine cannot
start work or power on.
2. If the water tank is dirty, clean by cool water or warm water, cannot use
cleaner, steel wool, chemical rag duster, gas oil, benzene, thinner or other
solvent to clean it, otherwise, it would damage the water tank and lead to
leakage.
3. When you place the water tank back into place, please use two hands to
push the water tank into the machine and force to the right position. If you do
not place the water tank in the right position, the machine would not power
on or start.

17
ENGLISH
CONTINUOUS DRAINAGE
This dehumidifier has a continuous drainage hole which used to be connected
by a plastic tube, then the dehumidification water can be continuous drainage.
• Turn off the unit and unplug, then insert the pipe
• Use a water hose to connect the water outlet.
• For continuous drainage, the end of the hose should not be submerged in
water to prevent it from being blocked or damaged.
CLEANING AND MAINTENANCE
The unit must be regularly cleaned to prolong its life and keep it functioning
properly.
Warning: Before performing any cleaning, turn off the unit and unplug it to
avoid electrical shocks.
Do not use hot water or chemical solvents for cleaning.
1. Regularly, clean the Water Tank and its cover with cold or warm water and
dry with a soft cloth to avoid any mildew.
2. Clean the surface of the unit using a moist cloth. Do not use detergents or
abrasive sponges that can cause damage to the plastic surface.
3. When the unit will not be used for a long time, use the Internal Drying
Function to dry the interior to prevent mildew.
ACTIVE CARBON FILTER
This is a non-washable filter and can be cleaned by using vacuum cleaner.

18
ENGLISH
TROUBLESHOOTING
Before contacting the service, review this list which includes common incidents
that are not result of a defect in the device.
Problem Possible Cause Solution
Not working
No power supply Connect to a function-
ing outlet and switch on
Water Full Indication
Flashes
Drain water tank and
reset it, or re-position
the water tank to right
place
Small dehumidifying
capacity
Is the air filter clogged? Clean the air filter as
instructed
Is the intake duct or
discharge duct ob-
structed?
Remove the obstruction
from the discharge duct
or intake duct.
Loud noise when run-
ning
Is the machine put in
the plat place?
Put the machine on the
plat ground
Is the filter clogged? Wash the filter
Stop operation dur-
ing the dehumidifying
process
Whether the room
temperature is too high
or too low.
The dehumidifier may
start automatically
when the room tem-
perature be normal
The clothing cannot be
dry fast
Whether the room tem-
perature is very low
The wet clothing may
dry more slowly in low
temperature
PRODUCT REPAIR FOR APLLIANCES CONTAINING R290
Warnings
• Do not exceed impedance greeter than 0.236ohm in supply the appli-
ance is connected to. Failure to comply may lead the supply authority
to impose restrictions to connection. Please consult your energy supply
authority if the use of equipment exceeds 0.236 ohm.

19
ENGLISH
• All operators or refrigeration circuit maintenance personnel should obtain
a valid certificate issued by an industry-approved assessment agency to
determine their qualification for safe disposal of refrigerants as required
by the industry-approved assessment specification.
• Remember the environment when disposing of packaging around the ap-
pliance and when the appliance has reached its by date.
• A warning that the appliance shall be stored in a well-ventilated area
where the size corresponds to the room area as specified for operation.
• The appliance shall be stored to prevent mechanical damage from occur-
ring.
• Information for spaces where refrigerant pipes are allowed, including
statements
• that the installation of pipework shall be kept to a minimum.
• that pipework shall be protected from physical damage and, in the case
of flammable refrigerants, shall not be installed in an unventilated space.
• that compliance with national gas regulations shall be observed.
• that mechanical connections shall be accessible for maintenance pur-
poses.
• that, for appliances containing flammable refrigerants, the minimum floor
area of the room shall be mentioned in the form of a table or a single
figure without reference to a formula.
• A warning to keep any required ventilation openings clear of obstruction.
• A notice that servicing shall be performed only as recommended by the
manufacturer.
• A warning that ducts connected to an appliance shall not contain a poten-
tial ignition source.
• When the portable air conditioner or dehumidifier is turned on, the fan can
work continuously stable under normal conditions to provide the minimum
air volume of 100m3/h even when the compressor is closed due to the
temperature controller.
• Do not pierce or burn.
• Use only implements recommended by the manufacturer for defrosting or
cleaning.
• Do not perforate any of the components in the refrigerant circuit. Refriger-
ant gas may be odorless.
• Use care when storing the appliance to prevent mechanical faults.

20
ENGLISH
• Only persons authorized by an accredited agency certifying their compe-
tence to handle refrigerants in compliance with sector legislation should
work on refrigerant circuit.
• All repairs must be carried out in accordance with the manufacturer’s rec-
ommendations.
• Maintenance and repairs requiring the assistance of other qualified per-
sonnel must be carried out under the supervision of specialists in the use
of inflammable refrigerants.
• Do not perforate any of the components in the refrigerant circuit. Refriger-
ant gas may be odorless.
1. Checks to the area
Prior to beginning work on systems containing flammable refrigerants, safety
checks are necessary to ensure that the risk of ignition is minimized. For repair
to the refrigerating system, the following precaution shall be completed prior to
conducting work on the system.
2. Work procedure
Work shall be undertaken under a controlled procedure to minimize the risk
of a flammable gas or vapor being present while the work is being performed.
3. General work area
All maintenance staff and others working in the local area shall be instructed
on the nature of work being carried out. Work in confined spaces shall be
avoided.
4. Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector prior to and
during work, to ensure the technician is aware of potentially toxic or flammable
atmospheres. Ensure that the leak detection equipment being used is suitable
for use with all applicable refrigerants, i.e. non-sparking, adequately sealed or
intrinsically safe.
5. Presence of fire extinguisher
If any heat-processing operation is to be conducted on the refrigerating equip-
ment or any associated parts appropriate fire extinguishing equipment shall be
This manual suits for next models
1
Table of contents
Languages:
Other Singer Dehumidifier manuals

Singer
Singer SDHM-16L-55DIA User manual

Singer
Singer Dry Up SDHM-20L ECO User manual

Singer
Singer SDHM -10M User manual

Singer
Singer Arido SDHM-10L User manual

Singer
Singer Supreme Dry SDHM-25L-25DIA User manual

Singer
Singer SDHM-10DI User manual

Singer
Singer SDHM-16L PURE DRY ION User manual

Singer
Singer PrestoDry SDHM-10L-25DIA User manual

Singer
Singer Mega Dry SDHM-25L-50DI User manual

Singer
Singer SDHM-16L-55DIA User manual