Sony CCP-9000-C User manual

C:\Documents and Settings\Administrator\My Documents\3704635021\370463502CCP9000-
CWW\01GB01CV1-WW.fm masterpage:Right
CCP-9000-C
3-704-635-02 (1)
CENTER CONTROL PANEL PACK
CCP-9000-C
OPERATION MANUAL [English]
1st Edition (Revised 1)
MKS-8011 MKS-8031TB MKS-8032 MKS-8033 MKS-8035
MKS-8041 MKS-8075
1 M/E CONTROL PANEL
MKS-9011
2 M/E CONTROL PANEL
MKS-9012

C:\Documents and Settings\Administrator\My Documents\3704635021\370463502CCP9000-
CWW\01GB02CV2-WW.fm masterpage:Left
CCP-9000-C
3-704-635-02
(
1
)
2
To prevent fire or shock hazard, do not
expose the unit to rain or moisture.
To avoid electrical shock, do not open the
cabinet. Refer servicing to qualified
personnel only.
THIS APPARATUS MUST BE EARTHED.
For the customers in the USA
This equipment hasbeen tested and found to comply with the
limits for a Class A digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is
operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and,
if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own
expense.
You are cautioned that any changes or modifications not
expressly approved in this manual could void your authority to
operate this equipment.
The shielded interface cable recommended in this manual
must be used with this equipment in order to comply with the
limits for a digital device pursuant to Subpart B of Part 15 of
FCC Rules.
(MKS-8011/8031TB/8032/8033/8035/8041/8075 only)
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) this
devicemay notcause harmful interference, and(2) this device
must accept any interference received, inmcluding
interference that may cause undesired operation.
For customers in Canada (MKS-8011/8031TB/8032/8033/
8035/8041/8075 only)
This Class A digital apparatus complies with Canadian ICES-
003.
Pour les utilisateurs au Canada (MKS-8011/8031TB/8032/
8033/8035/8041/8075 uniquement)
Cet appareil numérique de la classe A est conforme à la
norme NMB-003 du Canada.
This symbol is intended to alert the user to the
presence of important operrating and
maintenance (servicing) instructions in the
literature accompanying the appliance.
WARNING: THIS WARNING IS APPLICABLE FOR USA
ONLY.
If used in USA, use the UL LISTED power cord specified
below.
DO NOT USE ANY OTHER POWER CORD.
Plug Cap Parallel blade with ground pin
(NEMA 5-15P Configuration)
Cord Type SJT, three 18 AWG wires
Length Less than 2.5 m (8 ft 3 in)
Rating Minimum 10 A, 125 V
Using this unit at a voltage other than 120V may require the
use of a different line cord or attachment plug, or both. To
reduce the risk of fire or electric shock, refer servicing to
qualified service personnel.
WARNING: THIS WARINING IS APPLICABLE FOR OTHER
COUNTRIES.
1. Use the approved Power Cord (3-core mains lead)/
Appliance Connector/Plug with earthing-contacts that
conforms to the safely regulations of each country if
applicable.
2. Use the Power Cord (3-core mains lead)/Appliance
Connector/Plug conforming to the proper ratings (Voltage,
Ampere).
If you have questions on the use of the above Power Cord/
Appliance Connector/Plug, please consult a qualified service
personnel.
WARNING
This unit has no power switch.
When installing the unit, incorporate a readily accessible
disconnect device in the fixed wiring, or connect the power
cord to a socket-outlet which must be provided near the unit
and easily accessible.
If a fault should occur during operation of the unit, operate the
disconnectdevicetowhichthepowersupplyoff,ordisconnect
the power cords.
AVERTISSEMENT
Cet appareil ne poss
ède pas d’interrupteur d’alimentation.
Lors de l’installation de l’appareil, incorporer un dispositif de
coupure dans le câblage fixe ou brancher le cordon
d’alimentation dans une prise murale proche de l’appareil et
facilement accessible.
En cas de problème lors du fonctionnement de l’appareil,
enclencher le dispositif de coupure d’alimentation ou
dèbrancher le cordon de la prise.
WARNING

C:\Documents and Settings\Administrator\My Documents\3704635021\370463502CCP9000-
CWW\01GB02CV2-WW.fm masterpage:Right
CCP-9000-C
3-704-635-02 (1)
3
WARNUNG
Dieses Gerät hat keinen Netzschalter.
Beim Einbau des Geräts ist daher im Festkabel ein leicht
zugänglicher Unterbrecher einzufügen, oder das Netzkabel
muß mit einer in der Nähe des Geräts befindlichen, leicht
zugänglichen Wandsteckdose verbunden werden.
Wenn während des Betriebs eine Funktionsstörung auftritt, ist
der Unterbrecher zu betätigen bzw. das Netzkabel
abzuziehen, damit die Stromversorgung zum Gerät
unterbrochen wird.
Um Feuergefahr und die Gefahr eines
elektrischen Schlages zu vermeiden, darf
das Gerät weder Regen noch Feuchtigkeit
ausgesetzt werden.
UmeinenelektrishenSchlag zu vermeiden,
darf das Gehäuse nicht geöffnet werden.
Überlassen SieWartungsarbeiten stets nur
qualifiziertem Fachpersonal.
DIESES GERÄT MUSS GEERDET
WERDEN.
Afin d’éviter tout risque d’incendie ou
d’électrocution, ne pas exposer cet
appareil à la pluie ou à l’humidité.
Afin d’écarter tout risque d’électrocution,
garder le coffret fermé. Ne confier
l’entretien de l’appareil qu’à un personnel
qualifié.
CET APPAREIL DOIT ÊTRE RELIÉ À LA
TERRE.
For the customers in Europe (MKS-9011/9012 only)
This product with the CE marking complies with both the EMC
Directive (89/336/EEC) and the Low Voltage Directive (73/23/
EEC) issued by the Commission of the European Community.
Compliance with these directives implies conformity to the
following European standards:
• EN60950: Product Safety
• EN55103-1: Electromagnetic Interference (Emission)
• EN55103-2: Electromagnetic Susceptibility (Immunity)
This product is intended for use in the following
Electromagnetic Environment: E4 (controlled EMC
environment, ex. TV studio).
Für Kunden in Europa (nur MKS-9011/9012)
Dieses Produkt besitzt die CE-Kennzeichnung und erfüllt
sowohldieEMV-Direktive(89/336/EEC)alsauchdieDirektive
Niederspannung (73/23/EEC) der EG-Kommission.
Die Erfüllung dieser Direktiven bedeutet Konformität für die
folgenden Europäischen Normen:
• EN60950: Produktsicherheit
• EN55103-1: Elektromagnetische Interferenz (Emission)
• EN55103-2: Elektromagnetische Empfindlichkeit
(Immunität)
Dieses Produkt ist für den Einsatz unter die folgende
elektromagnetische Bedingung ausgelegt: E4 (kontrollierter
EMV-Bereich, z.B. Fernsehstudio).
Pour les clients européens (MKS-9011/9012 uniquement)
Ce produit portant la marque CE est conforme à la fois à la
Directive sur la compatibilité électromagnétique (EMC) (89/
336/CEE) et à la Directive sur les basses tensions (73/23/
CEE) émises par la Commission de la Communauté
européenne.
La conformité à ces directives implique la conformité aux
normes européennes suivantes:
• EN60950: Sécurité des produits
• EN55103-1: Interférences électromagnétiques (émission)
• EN55103-2: Sensibilité électromagnétique (immunité)
Ce produit est prévu pour être utilisé dans l’environnement
électromagnétique suivant: E4 (environnement EMC contrôlé
ex. studio de télévision).
For the customers in Europe (MKS-8011/8031TB/8032/
8033/8035/8041/8075 only)
This product with the CE marking complies with the EMC
Directive (89/336/EEC) issued by the Commission of the
European Community.
Compliance with this directive implies conformity to the
following European standards:
• EN55103-1: Electromagnetic Interference (Emission)
• EN55103-2: Electromagnetic Susceptibility (Immunity)
This product is intended for use in the following
Electromagnetic Environment: E4 (controlled EMC
environment, ex. TV studio).
Für Kunden in Europa (nur MKS-8011/8031TB/8032/8033/
8035/8041/8075)
Dieses Produkt besitzt die CE-Kennzeichnung und erfüllt die
EMV-Direktive (89/336/EEC) der EG-Kommission.
Die Erfüllung dieser Direktive bedeutet Konformität für die
folgenden Europäischen Normen:
• EN55103-1: Elektromagnetische Interferenz (Emission)
• EN55103-2: Elektromagnetische Empfindlichkeit
(Immunität)
Dieses Produkt ist für den Einsatz unter die folgende
elektromagnetische Bedingung ausgelegt: E4 (kontrollierter
EMV-Bereich, z.B. Fernsehstudio).
VORSICHT
AVERTISSEMENT

C:\Documents and Settings\Administrator\My Documents\3704635021\370463502CCP9000-
CWW\01GB02CV2-WW.fm masterpage:Left
CCP-9000-C
3-704-635-02
(
1
)
4
Pour les clients européens (MKS-8011/8031TB/8032/8033/
8035/8041/8075 uniquement)
Ce produit portant la marque CE est conforme à la Directive
sur la compatibilité électromagnétique (EMC) (89/336/CEE)
émise par la Commission de la Communauté européenne.
La conformité à cette directive implique la conformité aux
normes européennes suivantes:
• EN55103-1: Interférences électromagnétiques (émission)
• EN55103-2: Sensibilité électromagnétique (immunité)
Ce produit est prévu pour être utilisé dans l’environnement
électromagnétique suivant: E4 (environnement EMC contrôlé
ex. studio de télévision).
Periodic inspections
To guarantee safe long-term operation, periodic inspections
are recommended. Please contact your Sony representative
for detailed information about the content and cost of periodic
inspections.
Voor de Klanten in Nederland (alleen voor de MKS-9011/
9012)
Dit apparaat bevat een vast ingebouwde batterij die niet
vervangen hoeft te worden tijdens de levensduur van het
apparaat.
Raadpleeg uw leverancier indien de batterij toch vervangen
moet worden.
De batterij mag alleen vervangen worden door vakbekwaam
servicepersoneel.
Gooi de batterijniet weg maarlever deze in alsklein chemisch
afval (KCA).
Lever het apparaat aan het einde van de levensduur in voor
recycling, de batterij zal dan op correcte wijze verwerkt
worden.
Für Kunden in Deutschland (nur MKS-9011/9012)
Wenn Sie das Gerät entsorgen wollen, wenden Sie sich bitte
an das nächste Sony-Kundendienstzentrum. Der eingebaute
Akku muß als chemischer Sondermüll entsorgt werden.

5
C:\Documents and Settings\Administrator\My Documents\3704635021\370463502CCP9000-
CWW\01GB00-WWTOC.fm masterpage:Right
CCP-9000-C
3-704-635-02
(
1
)
Table of Contents
Table of Contents
Overview ...............................................................................6
Features......................................................................................6
Units and Modules.....................................................................6
Optional Accessories .................................................................7
Location and Function of Parts...........................................8
MKS-9011/9012 Front Panel.................................................... 8
MKS-9011/9012 Rear Panel..................................................... 9
MKS-8011 Menu Panel.......................................................... 11
MKS-8075 Extension Adaptor............................................... 11
Example System Configuration ........................................12
MVS-8000 System Configuration.......................................... 12
Center Control Panel Connection........................................... 13
Exchanging Button Labels................................................14
Adjusting Fader Torque.....................................................14
Power Supply Unit Status Indicators................................15
Maintenance........................................................................15
Specifications.....................................................................16
Center Control Panel................................................................16
MKS-9011 1 M/E Control Panel.............................................16
MKS-9012 2 M/E Control Panel.............................................17
MKS-8011 Menu Panel...........................................................17
MKS-8031TB Track Ball Module...........................................18
MKS-8032 DSK Fader Module...............................................18
MKS-8033 Utility/Shotbox Module........................................18
MKS-8035 Key Control Module.............................................18
MKS-8041 Blank Panel (1/2)..................................................18
MKS-8075 Extension Adaptor................................................18

C:\Documents and Settings\Administrator\My Documents\3704635021\370463502CCP9000-
CWW\01GB03BOD-WW.fm masterpage:Left
6
CCP-9000-C
3-704-635-02
(
1
)
Overview
Overview
Overview The CCP-9000 Center Control Panel Pack
provides control panels for operation of the MVS-8000/
8000SF Multi Format Switcher system or DVS-9000/
9000SFProductionSwitchersystem.Ithas a widerangeof
application, being usable in live production systems in
studios and ENG/ OB vans as well as in postproduction
editing systems.
“Center control panel” refers to the control panel as a
whole, which is comprised of the following Panel and
Extension module elements.
Control Panel
This is the main panel to provide the operating controls of
the system. Two types are available, the 1-M/E type
(MKS-9011) and the 2-M/E type (MKS-9012), and both
are equipped with 12 cross-point buttons. The main panel
is comprised of three sections: an operation section, a
control section, and a power supply section. Up to three
operation modules can be installed apart from the main
panel by mounting each module in an MKS-8075
Extension Adaptor.
Menu Panel
The menu panel provides a GUI interface for making
system settings.
Features
Control panel mountable in a 19-inch EIA
rack
The small-size control panel can be mounted in a 19-inch
EIA standard rack (height: 10 units).
The operation section, the control section and the power
supply section are integrated in a single unit.
Intuitive, easy-to-use man-machine
interface
The menu control block features a large, touch-sensitive
LCD panel for speedy menu operations.
Special features for mid- and large-scale
live switcher systems
The center control panel was designed with many features
for live operation, such as snapshot functions, sourcename
display on cross-point buttons, and redundant power
supply.
Powerful external device control
The center control panel can control devices such as Sony
routing switchers and IF processors. Control of devices
such as VTRs and DDRs can be linked to timelines of
switchers and DME.
Generous storage capacity
The center control panel has an internal hard disk drive for
storage of settings and still pictures from switcher frame
memory. A PCMCIA card slot is available for storage to
Memory Sticks and other memory cards.
Units and Modules
MKS-9011 1 M/E Control Panel
A 1 M/E control panel with 12 cross point buttons.
MKS-9012 2 M/E Control Panel
A 2 M/E control panel with 12 cross point buttons.
MKS-8011 Menu Panel
A menu operation panel equipped with a 10.4-inch color
LCD touch screen.
MKS-8031TB Track Ball Module
A module for DME operations using a track ball and for
switcher wipe positioner operations.
MKS-8032 DSK Fader Module
An operation module for fader lever operations on four
downstream keys.
MKS-8033 Utility/Shotbox Module
An operation module to provide buttons that may be used
as utility buttons or shotbox recall buttons.
MKS-8035 Key Control Module
An operation module for key adjustments and other
operations.
MKS-8041 Blank Panel (1/2)
A blank panel to fill parts of the main panel which are not
filled by the modules in its current configuration.
MKS-8075 Extension Adaptor
An adaptor which allows modules to be installed apart
from the main panel.

7
C:\Documents and Settings\Administrator\My Documents\3704635021\370463502CCP9000-
CWW\01GB03BOD-WW.fm masterpage:Right
CCP-9000-C
3-704-635-02 (1)
Overview
Optional Accessories
SWC-5002 50-pin Panel Cable (2 m/7 ft)
SWC-5005 50-pin Panel Cable (5 m/16 ft)
SWC-5010 50-pin Panel Cable (10 m/33 ft)

C:\Documents and Settings\Administrator\My Documents\3704635021\370463502CCP9000-
CWW\01GB03BOD-WW.fm masterpage:Left
8
CCP-9000-C
3-704-635-02
(
1
)
Location and Function of Parts
Location and Function of Parts
MKS-9011/9012 Front Panel
aMemory card slot
A slot for memory cards that complies with the PCMCIA
Type II standard. Used to install software and to save and
read data such as snapshot, key frame effects, and setup
data.
bMomory card access indicator
Lights when a memory card is being read from or written
to.
Note
Do not remove a memory card while this indicator is lit.
cPOWER A, B status indicators
The status indicators light in green when the unit is
powered on.
Note
If the status indicators do not light even though the AC
power cord is connected, there may be failure in the unit.
Disconnect the AC power cord and contact a Sony service
or marketing representative.
dDEVICE connector (USB Type A)
Connect a mouse, keyboard, pen tablet or other device
with a USB interface.
Note
Contact a Sony service or marketing representative for
more information about connectable devices.
POWER
AB
1Memory card slot
2Memory card access indicator
4DEVICE connector
3POWER A, B status indicators

9
C:\Documents and Settings\Administrator\My Documents\3704635021\370463502CCP9000-
CWW\01GB03BOD-WW.fm masterpage:Right
CCP-9000-C
3-704-635-02 (1)
Location and Function of Parts
MKS-9011/9012 Rear Panel
aMENU PANEL connector (D-sub 50-pin,
special interface)
Connect to the menu panel.
bEXT (extension) PANEL connector (D-sub 50-pin,
special interface)
Connect to the MKS-8075 Extension Adaptors to install
operation modules apart.
c- AC IN (AC power input) A and B connectors
(3-pin)
Connect to 100 to 240 V AC power supply with the
optional AC power cords.
dGPI (General Purpose Interface) connector
(D-sub 25-pin)
Connect to external devices for input and output of trigger
signals. Up to eight inputs and eight outputs are possible,
with input and output conditions set on the center control
panel.
eU(signal ground) terminal
Connect to the system ground.
fPERIPH (peripheral) connector (RJ-45)
Connect to the DCU-8000 Device Control Unit Pack with
a cross cable to enable communications with the DCU-
8000.
Note
An Ethernet switch is required to connect two or more
DCU-8000 Device Control Units.
Caution
When using a LAN cable: For safety, do not connect to a
connector for peripheral device wiring that might have
excessive voltage.
EXT DISPLAY DATA MENU PANEL EXT PANEL EDITOR PANEL REF IN REMOTE CTRL PERIPH GPI
BA
8REMOTE connector
9REF IN connectors
4GPI connector
3- AC IN A and B connectors
5Uterminal
0EDITOR PANEL connector
6PERIPH connector
qaDATA connector
7CTRL connector
1MENU PANEL connector
qsEXT DISPLAY connector
2EXT PANEL connector

C:\Documents and Settings\Administrator\My Documents\3704635021\370463502CCP9000-
CWW\01GB03BOD-WW.fm masterpage:Left
10
CCP-9000-C
3-704-635-02
(
1
)
Location and Function of Parts
gCTRL (control) connector (RJ-45)
Connect to an Ethernet switch*.
The MVS-8000/DVS-9000 Switcher Processor Pack, the
MVE-8000 DME Processor Pack and other devices are
connected in the same way to the Ethernet switch to form
a network for exchange of signals between the devices.
This network is used primarily to control the various
devices from the center control panel.
* For information about Ethernet switches that can be used in an MVS
system, contact your Sony service representative.
* Ethernet is a trademark of XEROX Corporation.
For more information about Ethernet switch connectors,
see “MVS-8000 System Configuration” (page 12).
For detailed information about setting up the Ethernet
switch, refer to the documentation supplied with the
Ethernet switch.
Caution
When using a LAN cable: For safety, do not connect to a
connector for peripheral device wiring that might have
excessive voltage.
hREMOTE connector (BNC type)
Connectthisconnectorwitha BNCcable toan S-BUSdata
link via a T bridge.
An S-BUS data link is a single signaling circuit (S-BUS)
to which multiple devices can be connected to exchange
data.
Connecting devices such as HDS-X series routing
switchers and remote panelsto an S-BUS data link enables
the following kinds of control.
• Returning to the S-BUS, tallydata created by thisunit on
the basis of data received from other devices
• Switching the cross-points ofa routingswitcher from the
center control panel
• Switching the cross-points of a switcher from the remote
panel
• Displaying on the center control panel source names set
on a routing switcher
iREF IN (reference signal input) connectors
(BNC type)
Ifyou wishtosynchronizethisunittoan externalreference
signal, input the reference signal. For an HDTV system,
input an HD tri-level sync signal, black burst signal, or
analog sync signal. For an SDTV system, input a black
burst signal or analog sync signal.
The two connectors have a loop-through configuration.
Signal input to one connector can be output from the other
connector. If you will not be using the loop-through
output, be sure to terminate the unused connector with the
supplied 75Ωterminator.
jEDITOR PANEL connector (D-sub 9-pin,
RS-422A)
This connector is reserved for future system expansion.
kDATA connector (RJ-45)
Connect to an Ethernet switch.
The MVS-8000/DVS-9000 Switcher Processor Pack, the
MVE-8000 DME Processor Pack and other devices can be
connected in the same way to the Ethernet switch to form
a network for exchange of signals between the devices.
This network is used primarily for exchange of various
types of data (key frame effects, snapshots, etc.) and still
pictures of frame memory.
Caution
When using a LAN cable: For safety, do not connect to a
connector for peripheral device wiring that might have
excessive voltage.
lEXT (extension) DISPLAY connector
(high-density D-sub 15-pin, analog RGB)
This connector is reserved for future system expansion.

11
C:\Documents and Settings\Administrator\My Documents\3704635021\370463502CCP9000-
CWW\01GB03BOD-WW.fm masterpage:Right
CCP-9000-C
3-704-635-02 (1)
Location and Function of Parts
MKS-8011 Menu Panel
SCU connector (D-sub 50-pin, special interface)
Connect to the MENU PANEL connector of the MKS-
8010/9011/9012 System Control Unit.
MKS-8075 Extension Adaptor
aSCU IN (system control unit input) connector
(D-sub 50-pin, special interface)
Connect to one of the EXT PANEL connectorof the MKS-
8010/9011/9012 System Control Unit or to the SCU OUT
connector of the MKS-8075.
bSCU OUT (system control unit output) connector
(D-sub 50-pin, special interface)
Connect to the SCU IN connector of the MKS-8075.
SCU connector
OUT
IN
1SCU IN connector 2SCU OUT connector

C:\Documents and Settings\Administrator\My Documents\3704635021\370463502CCP9000-
CWW\01GB03BOD-WW.fm masterpage:Left
12
CCP-9000-C
3-704-635-02
(
1
)
Example System Configuration
Example System Configuration
MVS-8000 System Configuration
CTRLDATA LAN
DATA CTRL REMOTE 1 CTRL
REMOTEDATA PERIPH
PERIPH
Reference video signal b)
BVE-9100 Editing
Control System
Ethernet switch a)
MVE-8000 DME
Processor Pack
MKS-9011/9012
System Control Unit
BKS-R Series
HDS-X Series
Reference
video signal b)
Reference video signal b)
Cross cable
Cable with BNC
connectors
MVS-8000SF Switcher Processor Pack
Ethernet switch a)
VTR DDR Audio Mixer
Reference video signal b)
DCU-8000 Device Control Unit Pack
a)It is recommended that the CTRL and DATA LAN
networks be configured by connecting separate
Ethernet switches for each LAN.
However, it is also possible to make connections
for both LANs on a single Ethernet switch.
b)Terminate with the supplied 75Ωterminators.
Terminators are supplied in the product package.

13
C:\Documents and Settings\Administrator\My Documents\3704635021\370463502CCP9000-
CWW\01GB03BOD-WW.fm masterpage:Right
CCP-9000-C
3-704-635-02 (1)
Example System Configuration
Center Control Panel Connection
The follwing table shows the number of modules that can
be connected to a MKS-9011/9012.
(Up to a total of 3 modules can be connected.)
Contact your Sony service representative for more
information about connectable devices.
Note
To make connections to the EXT PANEL connector,
MAIN PANEL connector, and MENU PANEL connector
on the MKS-9011/9012 System Control Unit, always use
the cables supplied in the package, or SWC-5002/5005/
5010 cables.
MENU PANEL
SCU IN
SCU IN
SCU OUT
SCU IN
SCU OUT EXT PANEL
SCU
MKS-8075 Extension Adaptor
Reference video signal
MKS-8011
Menu Panel
MKS-9011/9012 System Control Unit
100 to 240 V AC power supply
Model Module name Max. modules
MKS-8031TB Track Ball Module 1
MKS-8033 Utility/Shotbox Module 2
MKS-8035 Key Control Module 3
MKS-8032 DSK Fader Module 3

C:\Documents and Settings\Administrator\My Documents\3704635021\370463502CCP9000-
CWW\01GB03BOD-WW.fm masterpage:Left.L1+L1
14
CCP-9000-C
3-704-635-02 (1)
Exchanging Button Labels / Adjusting Fader Torque
Exchanging Button
Labels
A button top puller is supplied with the center control
panel.
After changing a pattern assigned to a numeric button, you
can use the following procedure to exchange the button
label.
1
Writethenewpatternonone ofthe suppliedexchange
labels.
2
Grip the holes on the button sides with the supplied
button top puller and remove the button.
3
Grip the slots on the sides of the white button cap with
the button top puller, so that the cap flexes slightly,
and remove the cap.
4
Remove the old label and insert the new label.
5
Replace the button cap.
6
Replace the button in its original location.
Adjusting Fader Torque
You can adjust faders without removing them from the
center control panel or operation modules.
Proceed as follows to adjust faders.
1
Pull the fader lever to an upright position between the
two holes on the fader cover.
2
Insert a hexagonal screwdriver or a hexagonal wrench
(2.5 mm sides) into one or both of the holes and rotate
to adjust the torque.
Rotate clockwise:
Fader lever operation becomes firmer.
Rotate counterclockwise:
Fader lever operation becomes freer.
23

15
C:\Documents and Settings\Administrator\My Documents\3704635021\370463502CCP9000-
CWW\01GB03BOD-WW.fm masterpage:Right.L1+L1
CCP-9000-C
3-704-635-02 (1)
Power Supply Unit Status Indicators / Maintenance
Power Supply Unit Status
Indicators
The power supply unit status indicators show the status of
the power supply unit during operation and when the unit
is powered on.
Maintenance
Clean the menu display screen (touch screen) with a soft
cloth lightly moistened with ethanol.
Be sure to wipe only the dirty places lightly, taking care
not to spread the dirt. Moistening the cloth with too much
ethanol may also result in spreading the dirt.
A lens cleaning cloth may be useful to clean the screen.
Notes
• Do not use liquid other than ethanol to clean the screen.
• Be careful not to drip ethanol between the screen and the
body while cleaning.
• Wiping the screen with excessive force may scratch the
surface.
For details of the menu display, refer to the User’s Guide
for the MVS-8000 series/DVS-9000 series.
Meaning of status indicator displays
Indicator
color Status Description Steps to take
Green Lit Operating normally −
−Not lit Power supply unit
fault Exchange the
power supply
unit

C:\Documents and Settings\Administrator\My Documents\3704635021\370463502CCP9000-
CWW\01GB03BOD-WW.fm masterpage:Left
16
CCP-9000-C
3-704-635-02
(
1
)
Specifications
Specifications
The following specifications show the reference
performance for this unit and individual option boards/
modules.
Design and specifications are subject to change without
notice.
Center Control Panel
The center control panel is comprised of the MKS-9011 1
M/E Control Panel or the MKS-9012 2M/E Control Panel
and Menu Panel (MKS-8011).
The following accessories are center control panel
accessories.
Accessories supplied
75Ωterminator (1)
T bridge (1)
Button top puller (1)
50-pin cables*
Switch cover 12 (20)
Switch cover 15 (20)
Self-lighting switch chip (5)
Operation Manual (1)
Installation Manual (1)
User’s Guide (2)
Software License Agreement (1)
∗The number depends on the system configuration.
MKS-9011 1 M/E Control Panel
General
Power requirements
AC 100 to 240 V, 50/60Hz
Power consumption
100V: 1.0A, 240V: 0.5A
Operating temperature
5ºC to 40ºC (41ºF to 104ºF)
Peak inrush current
(1) Power ON, current probe method:
20 A (100 V), 60 A (240 V)
(2) Hot switching inrush current,
measured in accordance with
European standard EN55103-1: 11 A
(230 V)
Performance temperature
10ºC to 35ºC (50ºF to 95ºF)
Storage temperature
−20ºC to +60ºC (−4ºF to +140ºF)
Operating humidity
10% to 90%
Dimensions (w/h/d)
478×208×442 mm (187/8×81/4×171/2
inches)
Mass Approx. 11.5 kg (25 lb 5 oz)
PC card slot Type II×1 (Supports CardBus)
Reference input
REF IN BNC type, 75Ω, with loop-through
output
HDTV systems:
HD tri-level sync/SDTV analog black
burst/SDTV analog sync
SDTV systems:
Analog black burst/analog sync
Control connectors
CTRL RJ-45
Complies with 100Base-TX standard
DATA RJ-45
Complies with 100Base-TX standard
PERIPH RJ-45
Complies with 100Base-TX standard
MENU PANEL D-sub 50-pin, female
EXT PANEL D-sub 50-pin, female
DEVICE USB Type A
Maximum supply current 400 mA
REMOTE BNC type, 75Ω
S-BUS
Data transfer rate: 312/1250 Kbps
GPI D-sub 25-pin, female
TTL inputs: 8
Relay contact outputs: 4 (30 V AC/DC,
0.1 A)
Open collector outputs: 4
EDITOR PANEL
D-sub, 9-pin, female
Complies with RS-422A standard
Data transfer rate: 38.4 Kbps
Video output
EXT DISPLAY High-density D-sub 15-pin, female
Analog RGB
AC input
AC IN A, B 3-pin AC connector
Accessories not supplied
AC power cord (for USA and Canada only) (125 V 10 A
2.4 m (8 ft)) (Part No.: 1-557-377-11)

17
C:\Documents and Settings\Administrator\My Documents\3704635021\370463502CCP9000-
CWW\01GB03BOD-WW.fm masterpage:Right
CCP-9000-C
3-704-635-02 (1)
Specifications
AC power cord (for Europe only) (250 V 10 A 2.4 m (8 ft))
(Part No.: 1-782-929-21)
MKS-9012 2 M/E Control Panel
General
Power requirements
AC 100 to 240 V, 50/60Hz
Power consumption
100V: 1.1A, 240V: 0.5A
Operating temperature
5ºC to 40ºC (41ºF to 104ºF)
Peak inrush current
(1) Power ON, current probe method:
20 A (100 V), 60 A (240 V)
(2) Hot switching inrush current,
measured in accordance with
European standard EN55103-1: 11 A
(230 V)
Performance temperature
10ºC to 35ºC (50ºF to 95ºF)
Storage temperature
−20ºC to +60ºC (−4ºF to +140ºF)
Operating humidity
10% to 90%
Dimensions (w/h/d)
478×208×442 mm (187/8×81/4×171/2
inches)
Mass Approx. 12.5 kg (27 lb 8 oz)
PC card slot Type II×1 (Supports CardBus)
Reference input
REF IN BNC type, 75Ω, with loop-through
output
HDTV systems:
HD tri-level sync/SDTV analog black
burst/SDTV analog sync
SDTV systems:
Analog black burst/analog sync
Control connectors
CTRL RJ-45
Complies with 100Base-TX standard
DATA RJ-45
Complies with 100Base-TX standard
PERIPH RJ-45
Complies with 100Base-TX standard
MENU PANEL D-sub 50-pin, female
EXT PANEL D-sub 50-pin, female
DEVICE USB Type A
Maximum supply current 400 mA
REMOTE BNC type, 75Ω
S-BUS
Data transfer rate: 312/1250 Kbps
GPI D-sub 25-pin, female
TTL inputs: 8
Relay contact outputs: 4 (30 V AC/DC,
0.1 A)
Open collector outputs: 4
EDITOR PANEL
D-sub, 9-pin, female
Complies with RS-422A standard
Data transfer rate: 38.4 Kbps
Video output
EXT DISPLAY High-density D-sub 15-pin, female
Analog RGB
AC input
AC IN A, B 3-pin AC connector
Accessories not supplied
AC power cord (for USA and Canada only) (125 V 10 A
2.4 m (8 ft)) (Part No.: 1-557-377-11)
AC power cord (for Europe only) (250 V 10 A 2.4 m (8 ft))
(Part No.: 1-782-929-21)
MKS-8011 Menu Panel
General
Power requirements
12 V DC
Power consumption
Max. 1A
Dimensions (w/h/d, excluding projections)
424×46×220 mm
(163/4×113/16×83/4inches)
Mass Approx. 2.5 kg (5 lb 8 oz)
Control connectors
SCU D-sub 50-pin, female
Accessories supplied
Operation and Installation Guide (1)
(supplied only when product is purchased separately)

C:\Documents and Settings\Administrator\My Documents\3704635021\370463502CCP9000-
CWW\01GB03BOD-WW.fm masterpage:Left
18
CCP-9000-C
3-704-635-02
(
1
)
Specifications
MKS-8031TB Track Ball Module
Power requirements
12 V DC
Power consumption
Max. 1 A
Dimensions (w/d, excluding projections)
220×132 mm (83/4×51/4inches)
Mass Approx. 0.7 kg (1 lb 8 oz)
Accessories supplied
Operation and Installation Guide (1)
(supplied only when product is
purchased separately)
MKS-8032 DSK Fader Module
Power requirements
12 V DC
Power consumption
Max. 1 A
Dimensions (w/d, excluding projections)
220×132 mm (83/4×51/4inches)
Mass Approx. 0.8 kg (1 lb 12 oz)
Accessories supplied
Operation and Installation Guide (1)
(supplied only when product is
purchased separately)
MKS-8033 Utility/Shotbox Module
Power requirements
12V DC
Power consumption
Max. 1.5 A
Dimensions (w/d, excluding projections)
220×132 mm (83/4×51/4inches)
Mass Approx. 0.7 kg (1 lb 8 oz)
Accessories supplied
Operation and Installation Guide (1)
(supplied only when product is
purchased separately)
MKS-8035 Key Control Module
Power requirements
12 V DC
Power consumption
Max. 1 A
Dimensions (w/d, excluding projections)
220×132 mm (83/4×51/4inches)
Mass Approx. 0.6 kg (1 lb 5 oz)
Accessories supplied
Operation and Installation Guide (1)
(supplied only when product is
purchased separately)
MKS-8041 Blank Panel (1/2)
Power requirements
12 V DC
Power consumption
Max. 0.1 A
Dimensions (w/d, excluding projections)
220×132 mm (83/4×51/4inches)
Mass Approx. 0.4 kg (14 oz)
Accessories supplied
Operation and Installation Guide (1)
(supplied only when product is
purchased separately)
MKS-8075 Extension Adaptor
General
Power requirements
12 V DC
Power consumption
Max. 0.5 A
Dimensions (w/h/d, excluding projections)
263×79×132 mm
(103/8×31/8×51/4 inches)
Mass Approx. 0.9 kg (1 lb 15 oz)
Control connectors
EXT IN D-sub 50-pin, male
EXT OUT D-sub 50-pin, female
Accessories supplied
50-pin cable (1)
Connecting panel A (2)
Connecting panel B (1)
Connecting panel C (1)
Connecting screws (+BV 3×10) (4)
Panel cover (L) (1)
Panel cover (R) (1)
Operation and Installation Guide (1)
(supplied only when product is purchased separately)

C:\Documents and Settings\Administrator\My Documents\3704635021\370463502CCP9000-
CWW\01GB04CV4-WW.fm masterpage:Right
CCP-9000-C
3-704-635-02
(
1
)
The material contained in this manual consists of information
that is the property of Sony Corporation and is intended solely
for use by the purchasers of the equipment described in this
manual.
Sony Corporation expressly prohibits the duplication of any
portion ofthis manual or the use thereof for any purpose other
thantheoperationormaintenanceoftheequipmentdescribed
in this manual without the express written permission of Sony
Corporation.
Le matériel contenu dans ce manuel consiste en informations
qui sont la propriété de Sony Corporation et sont destinées
exclusivement à l’usage des acquéreurs de l’équipement
décrit dans ce manuel.
Sony Corporation interdit formellement la copie de quelque
partie que ce soit de ce manuel ou son emploi pour tout autre
but que des opérations ou entretiens de l’équipement à moins
d’une permission écrite de Sony Corporation.
Das in dieser Anleitung enthaltene Material besteht aus
Informationen, die Eigentum der Sony Corporation sind, und
ausschließlich zum Gebrauch durch den Käufer der in dieser
Anleitung beschriebenen Ausrüstung bestimmt sind.
Die Sony Corporation untersagt ausdrücklich die
Vervielfältigung jeglicher Teile dieser Anleitung oder den
Gebrauch derselben für irgendeinen anderen Zweck als die
Bedienung oder Wartung der in dieser Anleitung
beschriebenen Ausrüstung ohne ausdrückliche schriftliche
Erlaubnis der Sony Corporation.

C:\Documents and Settings\Administrator\My Documents\3704635021\370463502CCP9000-
CWW\01GB04CV4-WW.fm masterpage:Left
CCP-9000-C
3-704-635-02 (1)
SonyCorporation
B&PCompany
Printed in Japan
2003.01.13
©2002
CCP-9000-C
(WW)
3-704-635-02 (1) Printed on recycled paper
Other manuals for CCP-9000-C
1
This manual suits for next models
9
Table of contents
Other Sony Control Panel manuals

Sony
Sony MKS-R3210 User manual

Sony
Sony RM-X7BT User manual

Sony
Sony RCP-1001 User manual

Sony
Sony RCP-730 User manual

Sony
Sony RCP-D50 User manual

Sony
Sony BKDS-7080 User manual

Sony
Sony RCP-TX7 User manual

Sony
Sony CCP-9000A-C User manual

Sony
Sony MKS-9011A User manual

Sony
Sony BKDS-7017 Instruction Manual