Takex MS-12TE User manual

DUAL ZONE OUTDOOR PIR
MS-12TE & MS-12FE
INSTRUCTION MANUAL
We appreciate your purchase of a TAKEX passive infrared sensor. This sensor will provide long and dependable service when properly
installed. Please read this Instruction Manual carefully for correct and effective use.
Please Note: This sensor is designed to detect intrusion and to initiate an alarm; it is not a burglary-preventing device.
TAKEX is not responsible for damage, injury or losses caused by accident, theft, Acts of God (including inductive surge
by lightning), abuse, misuse, abnormal usage, faulty installation or improper maintenance.
The dual zone outdoor PIR is an automatic switch which uses passive infrared sensor to detect infrared (body
temperature) emitted from a human body. (Suitable for indoor/outdoor)
1) This sensor is equipped with an "AND" detection and pulse count system.
2) The AND detection system will issue an alarm signal only when detection occurs
in both horizontal and downward zones simultaneously.
3) The sensor is equipped with many features such as
¬Alarm output control depending on the illuminance of the surrounding area.
ÁOutput time delay switch setting.
ÂCombining the sensor with other devices such as a video monitoring system to display and record the
presence of an intruder.
The sensor can be combined with an audible or visual warning device to annunciate the presence of visitors.
Lower Sensor
Upper Sensor
Body
Cover
Sensor
[MS-12TE] [MS-12FE]
Cover locking screw
Operation LED
Lens
Wiring hole Wiring knockout
(4 corners)
Setting
switch
Adjustment
lever
Adjustment
volume
Adjustment
lever
Adjustment
volume
Setting
switch
Area masking sheet
self tapping screw
2 pcs
Accessory

1. Precautions on Installation
2. Other Precautions
•Install the unit at the height of 2.6’ to 4.0’ from the ground. •Do not install the unit by
an air conditioning exhaust
vent.
•Remove all obstructions
(trees, clotheslines, etc.).
•Remove all obstacles (including clear glass), which will
create non detection zone.
•Make sure that downward zone will not be affected by sun
light reflected by water on the road etc.
•Operation LED blinks for about 1 min after turning on power.
During this warm up period, the sensor doesn’t make
detection.
•Day light switch allows this unit to issue an alarm signal only
when the surrounding area is darker than set illuminance.
In other words, if surrounding area is brighter than set
illuminance, this sensor doesn’t output signal.
•This sensor operates during detecting time + delay time set by
a potentiometer.
It continues to issue alarm as long as it detects objects
regardless of set delay time.
•Do not pour water on this unit with a hose as it is designed to
be rainproof, not waterproof.
•When detection mode is set at AND mode, this sensor outputs
alarm signal only when both upper and lower sensor detect
objects.
In other words, it won’t make detection in the area, which is
not covered by both upper and lower sensor.
[Only applicable to MS-12FE]
•Install the unit in such a direction that people are more
likely to cross the detection zone.
•Install the unit horizontally so that its horizontal zone is
parallel to the ground.
2.6’~4.0’ (0.8~1.2m)
Non detection area
Upper sensor coverage
(No detection)
Upper sensor coverage
Lower sensor coverage
Lower sensor coverage
(No detection)
[Detection area]
(This area covered by both
upper and lower sensor)

Horizontal zone
Alarm signal is issued only
when both horizontal and
downward zone detect objects.
It does not detect small
animals, which are not likely
to reach the height of
horizontal zone.
It does not detect vehicles
moving in the area outside the
range of the downward zone.
Downward zone
Detection distance
Detection distance
Detection distance
(12m)
40’
(12m)
40’
(1m)
3.3’
0(5m)
16.5’
(10m)
33’
(12m)
40’
[TOP VIEW]
Horizontal
Detection
[SIDE VIEW]
[Wide angle detection]
15º
Variable
Pitch
90º
ADJUSTABLE: 90º
VARIABLE: 180º
(10m)
33’
(10m)
33’
(5m)
16.5’
(5m)
16.5’
0
(12m)
40’
(12m)
40’
Fine Adjustment
[TOP VIEW]
Wall Detection
3” 3”
Masking
unnecessary zones.
Variable
range Downward Zone
Horizontal Zone Horizontal Zone
(10m)
33’
(10m)
33’
(5m)
16.5’
(5m)
16.5’
0
(12m)
40’
(12m)
40’
(1m)
3.3’
±90º
±90º
Sensor Centre
0(5m)
16.5’
(10m)
33’
(12m)
40’
[SIDE VIEW]
15º
Variable
Pitch
LOWER SENSOR
COVERAGE
UPPER SENSOR
COVERAGE
LOWER SENSOR
COVERAGE
UPPER SENSOR
COVERAGE
ADJUSTABLE: 90º
VARIABLE: 180º
(10m)
33’
(10m)
33’
(5m)
16.5’
(5m)
16.5’
0
(12m)
40’
(12m)
40’
Fine Adjustment
[TOP VIEW]
Wall Detection
DETECTION
MODE: OR
Fine Adjustment
3” 3”
3” 3”
Masking
unnecessary zones.
Variable
range Downward zone
(10m)
33’
(10m)
33’
(5m)
16.5’
(5m)
16.5’
0
Detection distance is set by adjusting the angle of downward zone.
Adjusting range 10’(3m) to 40’(12m). [7 ranges]
Detection distance is set by adjusting the angle of downward zone.
Adjusting range 10’(3m) to 40’(12m). [7 ranges]
The detection zone of this unit consists of
horizontal zone and downward zone.
Alarm signal is issued only when both detection
zones detect objects.
Detection distance can be set by adjusting the
angle of downward zone.
MS-12TE is equipped with 1 set of sensor on the
upper side.
MS-12FE is equipped with 2 sets of sensor on the
upper and lower side, making it possible to select
AND mode or OR mode.
Area adjustment
(1) Point the sensor to the centre of the area to be detected.
By turning the sensor up to ±45º, it can detect all
directions in front of it.
When the unit is turned more than ±45º, detection
zone will be eliminated one by one from the end.
(2) It consists of seven
detection zone
(Wide angle : 90º).
(3) Utilize attached area
masking sheet when
eliminating detection zone.
[MS-12TE] [MS-12FE]
[TOP VIEW]
Horizontal
Detection
X2
UPPER SENSOR
LOWER SENSOR
DETECTION
MODE: OR

(1) Attach area masking sheet (accessory) to the lens holder
of cover without cutting it out.
(2) Turn the sensor by 90º to the direction to be detected.
(3) Horizontal fine adjustment
Fine adjustment can be made within the range of ±3º, in
case there are some obstacles on the wall.
(Detection zone shifts about 2’(0.6m) at 40’(12m) range.)
Slide the lever to the left or right.
*Make sure that the lever is set at 0º for horizontal
detection.
(1) Cut the necessary area number on the area masking sheet.
See below area masking picture for your reference and cut
out the same place on both horizontal and downward zones.
(2) Attach the area masking sheet to the lens holder located
inside cover.
(3) Attach cover and check detection zone.
•Detection distance adjustment
Detection distance can be adjusted within a range from
10’(3m) to 40’(12m) by turning the angle of downward
zone vertically.
Refer to the index and slide the adjustment lever up or
down.
Slide it up and the detection distance becomes shorter,
sliding it down, detection distance becomes longer.
Detection distance depends on how the sensor is
installed and how its sensitivity adjustment is set.
•Area masking sheet
•When shifting detection
zone away from the wall,
slide the lever towards
the wall.
•When shifting detection
zone towards the wall,
slide the lever away from
the wall.
• Zone ➆cannot be masked by area masking sheet.
[Wall detection]
Index
Short distance
detection
Long distance
detection
Area masking sheet
Cut the necessary
area number
Cut the necessary
area number Print side
Cut off
Lens holder
Adjustable
range
Adjustment lever
Horizontal zone
Horizontal zone
Downward zone
Detection range
Downward zone
Detection range No detection

Operation LED blinks for about 1 min after supplying power.
The unit doesn’t operate for this time as it is the sensor
stabilising period.
The number of counts can be selected according to the
environmental conditions.
* MS-12FE has two sets of above switches upper and lower
sensor.
Alarm is triggered only when surrounding environment is
darker than the illuminance setting.
Warm up period Contact output selectable
Detection mode [Only applicable to MS-12FE]
Pulse count selectable
Sensitivity adjustment
LED ON/OFF selectable switch
Day Light
Operation time can be adjusted between 2sec. and to 5min.
approx.
Delay time
ON
OFF
ON
OFF
[Factory set]
•
•
ON
1a
1b
OFF
a (N.O)
b (N.C)
[Factory set]
•
•
Less sensitive, prevents false alarms
caused by temperature fluctuation.
More sensitive
ON
OFF
ON
OFF
[Factory set]
•
•
Lights at alarm
LED disabled. (During warm up
period, light flickers.)
ON
OFF
AND
OR
[Factory set]
•
•
Alarm signal is issued only when
both upper and lower sensors detect
objects simultaneously.
Alarm signal is issued when either
upper or lower sensors detect
objects.
The unit operates during night time only.
The unit operates day and night.
(Factory set)
Sensitivity can be adjusted between 30% (L)
and 170%(H).
[Factory set:100%]
Operation time can be adjusted between
2sec. and 5min. approx.
[Factory set : 2sec]
HL
NIGHT
DAY &
NIGHT
2 sec. 5 min.

1. Terminal Configuration 2. Wiring distance
SUPPLY VOLTAGE
•12V to 30VDC (Non Polarity)
•Power consumption
35mA MAX (MS-12TE)
40mA MAX (MS-12FE)
OUTPUT SIGNAL
Dry contact relay output form N.O/N.C selectable
CONTACT OPERATON
Detection time + off delay (2sec.-5min. approx.)
CONTACT CAPACITY
30V (AC/DC), 0.5A MAX. (resistive load)
DAY LIGHT
Output operates when daylight is below setting.
TAMPER
•Dry contact relay output N/C
CONTACT CAPACITY
30V (AC/DC), 0.5A MAX. (resistive load)
WIRE SIZE
AWG24 ~ AWG14 (0.2mm2) ~ (2mm2)
Exposed wiring
Mounted wiring
Power voltage
DC12V DC24V
0.3mm2(ø0.65mm) 820’ (250m) 8,500’ (2600m)
0.5mm2(ø0.8mm) 1,480’ (450m) 14,100’ (4300m)
0.8mm2(ø1.0mm) 2,300’ (700m) 21,300’ (6500m)
1.2mm2(ø1.25mm) 3,120’ (950m) 29,500’ (9000m)
Note: 1) Maximum wiring distance when two or more sets are
connected is the value above divided by number of sets.
2) The signal line can be wired to a distance of up to 3,000ft.
(1,000m) with AWG 22 (dia. 0.65mm) telephone wire.
3. Wire Insertion
•Break one outside knockout and its related inside knockout
as necessary.
Pull wire through the insertion holes and connect it to the
terminals.
•Break inside knockout,
pull wire through wiring
hole and connect it to the
terminals.
* When installing the sensor
to flush mount box, use
wall mount bracket (BW-
24) [sold separately].
Outside
knockout Inside
knockout
Wiring
hole
Wiring
box
Outside
knockout
(1) Read PRECAUTIONS (3) before installation.
(2) Loosen cover locking screw and detach cover. (3) Refer to WIRING (6) and connect wires to the terminal.
(4) Install the unit.
(5) Refer to DETECTION
AREA (4) and OPERATION
CHECK (8) and check
detection area and operation.
(6) Replace the cover.
Power
Cover locking screw
Contact output Tamper Size of wire

(1) Make final setting according to the purpose.
(2) Attach cover and check if operation LED and connected
devices operate properly.
1. Setting for operation check
• Operation LED : ON
• Day light : DAY & NIGHT
• Delay time : 2 sec.
(1) Determine the required area of detection and set the
horizontal angle of the sensor and detection distance.
(2) Attach cover and fix it to the sensor with the locking
screw.
(3) Turn the power ON and wait for 1 min. until the alarm
LED stops blinking.
(4) After warm-up period, operate a walk test in the
detection area to check, if the required area is covered.
(5) Readjust sensitivity, masking or count if necessary.
2. Operation check
Trouble Check Corrective Action
Completely Inactive 1. No power supply, broken wire or improper voltage. 1. Correct power supply or replace broken wire.
2. Cover shielded by substances (including glass). 2. Remove the substances.
3. Improper area adjustment. 3. Readjust the protection area setting.
4. Improper operation mode setting. 4. Readjust operation mode setting.
5. Not yet 1 minutes after power turned on. 5. Allow for warming up time (about 1 min.)
(Operation LED is flickering.)
6. No area covered by both upper and lower sensor 6. Readjust the sensor angle so that the area to be detected
when set at AND mode. [Only applicable to MS-12FE] is covered by both upper and lower sensor.
Sometimes Inactive 1. Improper area adjustment. 1. Readjust the protection area setting.
2. Improper operation mode setting. 2. Readjust operation mode setting.
3. Cover face is soiled with dust or water drop. 3. Clean the cover with soft cloth.
4. Area covered by both upper and lower sensor is too small to be 4. Readjust the sensor angle.
detected when set at AND mode. (Only applicable to MS-12FE)
Activated when no 1. Unstable power voltage. 1. Stabilize the power voltage.
person has passed 2. Something moving in protected area or too rapid 2. Remove the cause.
temperature variations.
3. Large electrical noise source such as power machine nearby 3. Relocate device.
or its wiring close to that of sensor.
4. Intense reflection of sunlight or head light shining on the sensor. 4. Relocate device. Readjust the protection area setting.
5. Reflecting lights such as sunlight or head light affect the 5. Remove reflective objects.
downward zone. Readjust the protection area setting.
6. Improper installation of the sensor. 6. Install the sensor parallel.
7. Detection distance of the downward zone is too long. 7. Readjust detection distance.
The alarm LED 1. Poor contact connection or broken wire or short circuit. 1. Check the wiring or connection.
lights, but connected 2. Contact output is not working. 2. Check the contact output terminal using a tester.
device is inactive 3. Is the connected device operation normal? 3. Check the connected device.
Solve possible problems according to the following table. If normal operations cannot be restored
by this means, contact either the dealer from whom you bought the unit or TAKEX.

Model MS-12TE MS-12FE
Detection system Passive infrared
Coverage When horizontal
detection Angle: 90º
Detection distance: 40’(12m)
2 sets of MS-12TE
Horizontal zone: 7 zones
sensor (Full cover 180º)
Downward zone: 7 zones
Coverage adjustment Horizontal : ±90º
Detection distance : 10’~40’ (3m~12m) [7 steps]
(By adjusting vertical angle of downward curtain)
Supply voltage 12 to 30V DC (Non polarity)
Current consumption 35mA MAX 40mA MAX
Alarm output Dry contact relay output N.C/N.O. selectable N.C/N.O
*Contact capacity: 30V (AC/DC), 0.5AMAX
(Resistive load)
*Contact operation: Detection time+off delay
(2sec.-5min.approx)
*Day light : 10 lux (night) - (day & night)
Tamper output Dry contact relay output N/C
*Contact capacity: 30V (AC/DC), 0.5A MAX
(Resistive load)
Operation LED Red LED
Blinking at Warming up
Lighting at alarm (LED disabled)
Counts selectable switch Once/three times (with a switch)
Sensitivity adjustment *Approx. 30% (L) – Approx. 170% (H) (By volume)
Detection mode AND/OR selectable
Connection Terminals
Ambient temperature -4ºF to 122ºF (-20ºC to 50ºC )
Mounting position Indoor/Outdoor (Height 0.8 – 1.2m)
Weight 13.7oz (390g) 16.5oz (470g)
Appearance Body: AES resin Lens: PE resin
Accessory Tapping screw: 2 Tapping screw: 2
Area masking sheet: 1 Area masking sheet: 2
Optional Wall mount attachment (BW-24)
Pole attachment (BP-22)
TAKEX Europe Limited.
Aviary Court, Wade Road,
Basingstoke,
HANTS RG24 8PE
UK
Tel. +44(0)1256-475555
Fax. +44(0)1256-466268
Webpage: www.takexeurope.com
MS-12FE SI-10/04 (CRI 175)
KNOCKOUT
11.5mmX8mm
(0.45”X0.31”)
KNOCKOUT
11.5mmX8mm
(0.45”X0.31”)
OPERATION LED
80mm
(3.15”)
234mm (9.21”)
209.5mm (8.25”)
107mm (4.21”)
91mm
(3.58”)
88mm
(3.46”) MOUNT HOLE
COVER LOCKING SCREW
ø4.5mm
2-ø0.18”
Limited Warranty
All TAKEX Products are subject to 5 years warranty.
All other warranty periods agreed are subject to a formal written agreement.
During the warranty period, TAKEX Europe Ltd. will repair or replace, as its sole
option, free of charge, any defective parts returned prepaid.
Our warranty does not cover damage or failure caused by Acts of God, abuse, misuse,
abnormal usage, faulty installation, improper maintenance, unauthorised customer
modifications or any repairs other than those carried out by TAKEX Europe Ltd.
Other manuals for MS-12TE
1
This manual suits for next models
1
Table of contents
Other Takex Accessories manuals

Takex
Takex PR-5B User manual

Takex
Takex DA-303S User manual

Takex
Takex ASW-SG85F User manual

Takex
Takex FS-3500E User manual

Takex
Takex PA-480S User manual

Takex
Takex MW-100AL Manual

Takex
Takex PA-6612E User manual

Takex
Takex TXF-125 Series User manual

Takex
Takex PA-15WE User manual

Takex
Takex TXF-20TDM User manual

Takex
Takex F71R User manual

Takex
Takex PXB-50HF-KH User manual

Takex
Takex PR-11BE User manual

Takex
Takex MS-12TE User manual

Takex
Takex GS-1100E User manual

Takex
Takex PB-IN-50HFA User manual

Takex
Takex PA-470L User manual

Takex
Takex TX-124R User manual

Takex
Takex PA-4810E User manual

Takex
Takex F85R User manual