1. Introduction.......................................................................3
2. Safety Information.............................................................4
3. System Overview ...............................................................7
4. Installation & Operating Instructions................................. 8
5. Resin Change...................................................................10
6. Technical Data .................................................................11
Tips for cleaning with pure water .......................................12
Spare Parts.......................................................................... 13
DANGER
!
• Spilled resin is a slipping hazard. Clean up
spilled resin immediately.
• Resin can cause skin irritation.
Avoid skin contact.
• Wash hands thoroughly after use.
• Can cause eye irritation. Avoid eye contact.
Wear safety goggles. In case of eye contact,
immediately ush eyes thoroughly with clean
water. Consult doctor if symptoms persist.
• Do not drink the water produced by this
system.
READ OPERATING INSTRUCTIONS
BEFORE USING PRODUCT!
STORAGE: Do not store resin in open or unlabeled containers. Store in a cool, dry place
(15°F to 100°F).
DISPOSAL: Dispose of in accordance with applicable federal, state/provincial, and local regulations.
All HydroPower Ultra units require the use of mixed bed ion exchange resin (commonly referred to as
de-ionizing resin).
Contents under pressure. Can cause severe
injury or death from tank rupture.
When starting system:
• Do not exceed pressure of 116 psi (8 Bar).
• Check system for cracks.
• Be sure cover is in locked position.
• Keep Water OUT connection open and hold yellow
lever down to remove trapped air from system.
• For use only with drinking (tap) water.
Before servicing system:
• Shut o tap water supply and open Water OUT
connection.
• Disconnect water supply and allow tank to drain.
• Before opening tank, Press yellow FastLock
™
opening lever to remove pressure the tank, rotate
handles counter-clockwise 1/8 turn, and remove top
cap using handles.

ENGLISH
Introduction
1. Introduction
Thank you for choosing HydroPower Ultra for your pure water needs. You have chosen a
high quality product backed by Unger’s 100% customer satisfaction guarantee. When used
as intended, the unit will produce zero TDS pure water for site glass cleaning.
The production of pure water, through deionization, is based on the principal of ion exchange.
In this process, the minerals responsible for producing spotting are removed from the water.
The use of HydroPower Ultra has the following advantages:
• With a waterfed wash pole and brush will eectively clean glass and other surfaces without
the need for chemicals.
• Run-o does not have to be remediated, and is safe for plants and animals.
• No electricity or external power supply needed – system works with plumbing line pressure.
• Resin packs are factory lled with the precise amount of mixed bed DI Resin for optimum
system performance.
As with any commercial equipment, care must be taken when operating and servicing the
unit. There is a risk of damage to the system due to:
• Operating and installation errors.
• Use of loose resin (overll and expansion of resin will damage unit).
• Vessel is opened incorrectly.
• Using non-Unger spare parts.
• Performing unauthorized modication to unit.
• Insucient maintenance.
Use only original spare parts by Unger (according to spare parts list, pg. 13).
For all inquiries and spare parts orders, it is important to provide detailed
information located on the device (serial and/or part number).

Safety Information
2. Safety Information
2.1 General
Please observe all applicable rules and regulations, including all accident prevention procedures.
Unger is not liable for damage to application areas, plumbing system, or persons.
Ensure work area has sucient water drainage.
Turn o water supply when not in use.
Ensure HydroPower Ultra System, including carts, are properly secured to car, trailer or truck
bed during transportation.
The user must meet all applicable local, state/provincial, federal licensing and registration
requirements and must strictly adhere to all applicable local, state/provincial and federal labor
laws and safety codes and standards.
2.2 Intended use
This system may be dangerous if it is improperly installed, not regularly maintained or not used
as intended. Use this system only for water treatment to reach an optimal water quality for glass
and surface cleaning. Any other use, especially water treatment for food production
(e.g., beverages) is prohibited.
2.3 Operating temperatures, pressures and connections
The system must be protected against frost. The temperatures in the operating area must be at
least 15°F. The water temperature should not exceed 86°F, and maximum operating pressure is
116 psi (8 Bar).

ENGLISH
Safety Information
2.4 General hazards
Read and follow ANSI Standard IWCA 1-14.1 (Window Cleaning Safety).
Puried water is delivered to the waterfed pole by hoses from the HydroPower Ultra system.
This introduces a risk of tripping both to worker and general public. Identify work area with
appropriate signage.
Any surface that becomes wet must be identied with appropriate signage to direct pedestrians
and workers away from work area. During wintertime, it is important to avoid water pooling,
which could freeze, creating a dangerous slip hazard.
General hazards associated with the use of water fed poles and deionization equipment1:
• Trip hazard to the general public when using hoses.
• Slip hazard presented from wet pathways.
• Slip hazard for operator when concentrating on work.
• Falls from height when working on at roofs.
• Electrocution from poles coming into contact with overhead power source.
• Injuries to others from falling poles or fabric of the building that may be dislodged.
• Injury to others from falling poles caused by incorrect handling or failure of pole.
• Injury through incorrect manual handling of poles and other equipment.
• Hazards from carrying tanks, systems and equipment that are overloaded, unstable,
unsecured or incorrectly installed within a vehicle.
1: British Window Cleaning Academy (BWCA): Safety in window cleaning using waterfed pole systems.

3
2
5
7a
7b
green = top position
in all units
red = middle and bottom
position in UHP3C
1
2
3
44
5
6
8
System Overview
3. System Overview
3.1 What is Pure Water?
Pure Water is water in its purest form, physically processed to remove the minerals that
would otherwise lead to limescale spots and streaks. Such impurities are referred to as TDS
(Total Dissolved Solids) and are measured in ppm (parts per million). Water is considered
100% demineralized (pure) when its TDS is measured at 0 ppm. The average TDS of
drinking water is 180 ppm.
3.2 HydroPower Ultra
1. Water IN connection,
chrome-plated brass, including valve
2. Water OUT connection
chrome-plated brass
3. FastLock opening lever
to release pressure in the
tank and to open the tank
4. Top Cap with Handles
to carry and open the system.
5. TDS Meter
to check the water quality
6. Tank
7. Ultra Resin Pack
8. Cart (only UHP3C)
3.3 Ultra Resin
Packs

ENGLISH
4. Installation and Operation
4.1 New Machine Setup
• Unpack unit: Inspect HydroPower Ultra unit and all components. Read warnings and
operating instructions.
• Inspection & Scope of Delivery: Refer to illustration; perform visual inspection and take
inventory of the following items that should be shipped with the system, then test system
for functionality:
• TDS Meter (powers on/o)
• FastLock lever (yellow) – depress lever, rotate in counter-clockwise direction and
remove top cap assembly.
• Ultra Resin Packs installed in unit.
- UHPR1 - One Green Pack
- UHPR2 - Three Green Packs
- UHPR3 - One Green & Two Red Packs
• Connection ttings installed in unit.
• Cart, wheels and tank clamp system (if purchased with cart).
• Water supply connection
• Inowing water temperature max. 86°F
• Temperature on site 41°F to 104°F; and not in the immediate vicinity of heat sources
or in direct sunlight.
Installation & Operation

Startup
4.2 Startup
1. LOCATE JOBSITE WATER SUPPLY
Unger recommends testing the on‐site water supply for TDS (total dissolved solids) prior
to working. Higher TDS levels reduce the system’s capacity.
• Inspect system – ensure Unger‘s Ultra Resin Packs are properly installed: the red Resin
Pack is only used on a large tank unit and placed in the middle and bottom position.
The green Resin Pack is used in all units and is placed in the top position. NOTE: The
performance of HydroPower Ultra is optimized when used with Ultra Resin Packs.
NEVER use loose resin as it may damage the system.
• Set up system in upright position.
• Choose a stable on‐site location.
2. CONNECT WATERFED WASH POLE TUBING
• Attach waterfed wash pole hose onto Water OUT connection (g. A).
• Ensure all on/o valves are in “OPEN” position when lling system.
3. CONNECT WATER SUPPLY (GARDEN HOSE) TO WATER IN CONNECTION
• Thread On/O Valve to garden hose prior to connecting water supply (g. B).
• Attach On/O Valve directly onto Water IN connection at base of unit (g. C).
4. TURN ON FEED WATER SUPPLY
• When water begins to ow out of the unit, turn on TDS meter and inspect pure water
quality (g. D). A reading of ‘0’ is best and indicates the system is running properly.
When the TDS meter reaches 10ppm or higher the resin should be replaced.
• Adjust ow at waterfed pole brush head by:
- Tap water valve or,
- Waterfed wash pole control (on/o) valve (if applicable).
A
C
B
D

ENGLISH
Operation & Resin Change
4.3 Operation
1. Periodically inspect the HydroPower Ultra system during use. Ensure hoses are properly
attached. Inspect system for leaks and proper t of top cap assembly.
2. Take care when working to ensure there is enough slack in waterfed pole tubing. This
tubing is connected to the top cover of the unit, and excessive tugging may cause the
system to tip over.
3. Tap water ows into the system’s lower connection port via tap pressure and ows
upwards through the HydroPower Ultra unit. Pure water exits through the top connection.
When plumbing line pressures fall below 44 psi (3 Bar), a reduction in ow rates will be
noticeable.
5. Resin Change
5.1 Resin Change - Ultra Resin Pack
Unger‘s pre-measured replacement Ultra Resin Packs are designed
to allow a controlled resin expansion within a designed safety limit.
1. SHUT OFF FEED WATER SUPPLY
• Depress yellow lever on system head assembly.
• Turn tap water valve to “OFF” position.
• Disconnect waterfed wash pole hose.
2. RELEASE SYSTEM HEAD ASSEMBLY
• While continuing to depress the yellow lever, use a counter-clockwise
quarter‐turn to release system head assembly; remove and set aside.
• Reach into housing and remove exhausted resin by hand; discard
according to local regulations.
• Press yellow FastLock opening lever (g. E) to remove pressure from
the tank.
• Steady (or “Stabilize”) the base unit with your feet, gently press the top
cap down and use a counter-clockwise 1/8 turn to release top cap
assembly; remove and set aside (g. F).
• Open all valves to facilitate the removal of the Ultra Resin Packs.
• Reach into housing and remove exhausted Ultra Resin Pack(s) by hand
with the rubber handle (g. G); discard according to local regulations.
E
F
G

H
3. REPLACE ULTRA RESIN PACKS
• Install new Ultra Resin Packs (g. H) – be sure to seat the packs with rubber
handle facing up. Pat down the resin pack by hand to ensure it is
seated properly.
Small Tank Unit (UHP01):
= 1x green Ultra Resin Pack
(never use red Ultra Resin Pack
in this unit!)
Large Tank Unit (UHP3C):
=
1x green Ultra Resin Pack (top position)
2x red Ultra Resin Packs (middle + bottom position)
green
red
red
green
I
J
L
K
4. REINSTALL TOP CAP ASSEMBLY
• Press down gently, then turn the top cap 1/8 clockwise while steadying
the base unit with your feet.
5. RECONNECT WATERFED POLE TUBING (g. I)
• Turn “ONˮ water supply at tap (g. J).
• Inspect system as it pressurizes.
• Keep discharge line open and hold down yellow lever to remove
trapped air from system (g. K).
6. TEST SYSTEM TDS (g. L) The value should be at 000.
Factor UHP01 UHP3C
Weight incl resin 21 lb. 71 lb.
Length x Width x Height 14.75ˮx13.75ˮx12ˮ 27.5ˮx21ˮx42.5ˮ
Inner Diameter 8ˮ 8ˮ
Dimension of base 11ˮx12ˮ 11ˮx12ˮ
Ultra Resin Packs 1x 1x , 2x
Max. permanent pressure (Bar) max. 8 max. 8
Max. water temp. (°F) 86˚F 86˚F
Min. water temp. (°F) 41˚F 41˚F
6. Technical Data
Resin Change &
Technical Data

ENGLISH
After cleaning I see stains or smudges on the window.
What could be causing this ?
How do I clean wooden window frames?
The cleaning was not thorough enough:
Make sure to wash o all visible dirt and residue. Rinse thoroughly.
Cleaning detergent residue on the surface:
If the window was previously cleaned using traditional method, it may take up to
2-3 rounds of cleaning with pure water to achieve desired results and remove all soap
residue from the glass.
The water is not 100% pure:
Water is considered pure when its TDS measure is 0 ppm - use the TDS meter to check.
To help ensure spot-free cleaning, the resin should be changed when the TDS meter
reads 10 ppm.
Consider the overall quality of the water being used, e.g., well water may contain
contaminants that make it unsuitable for window cleaning.
Wrong movement of the brush:
Always wash and rinse from top to bottom.
Dirt around the frames:
Over time, dirt may accumulate in and around the frames, especially when silicone joints
and rubber seals are not watertight. Water can loosen and transfer the dirt onto the glass,
so wash and rinse thoroughly.
Avoid glazed or oiled frames:
Pure water dissolves the oils or tannin.
Varnished window frames:
Avoid using pure water as it may accelerate stripping of these coatings.
Tips For Cleaning With Pure Water

Additional Tips
Damage to laminated and coated glass:
Test on a small area rst and allow to dry. Check the results before cleaning the entire
glass surface. Water beading on the surface may indicate hydrophobic glass – change to
Fan Jets for better results.
High air pollution:
Dirt particles present in the air, especially in heavy trac or high pollen count areas, may
aect cleaning results – you may need to dry the window with a squeegee.
Dirty brush:
Clean the brush to avoid transferring any impurities back onto the window.
Post construction cleaning:
This may require removal of plaster, stucco, concrete, paint, texture, taping mud,
mortar, silicone, stickers and tape from glass. Generally, traditional glass cleaning
methods are recommended for this type of cleaning.
Scratching of plexiglass & acrylic:
Surface dirt retained through static charge can produce scratches in the soft material.
Apply plenty of pure water and use a soft brush such as a boar bristle brush. Advise client
of the risk of scratching.
Lack of experience:
Ask for advice! Your Approved Unger Dealer, Unger Customer Service Team or your
UNGER Sales Representative will be happy to help you.
Tips for cleaning
with pure water

ENGLISH
A21064 Water OUT Connection with O-Ring
1
B18481 Water OUT Hose Connection
1
C21066 FloWater™Unit
1
D21065 Water IN On/Off Connection
1
E21063 O-Rings (5), Care Resolution
1
F21071 Top Cap Assembly
1
G21151 TDS Meter
1
H 21504 Water IN Hose Connection
1
Key Code Part # Description Case Qty.
E
G
F
H
A
B
C
D
Spare Parts

Contenido
1. Introducción ......................................................................3
2. Información de seguridad..................................................4
3. Descripción general del sistema .......................................7
4. Instrucciones de instalación y operación.......................... 8
5. Cambio de resina............................................................. 10
6. Datos técnicos.................................................................11
Consejos para la limpieza con agua pura............................12
Piezas de repuesto ..............................................................13
PELIGRO
!
• La resina derramada constituye un riesgo de
resbaladura. Limpie inmediatamente la resina
derramada.
• La resina puede causar irritación de la piel. Evite
el contacto con la piel.
• Lávese bien las manos después de cada uso.
• Puede causar irritación de los ojos. Evite el
contacto con los ojos. Use gafas de seguridad.
Si ocurre el contacto con los ojos, enjuáguese
inmediatamente los ojos completamente con
agua limpia. Si los síntomas persisten, consulte
al médico.
• No beba el agua producida por este sistema.
¡LEA EL MANUAL DE INSTRUCCIONES
ANTES DE USAR EL PRODUCTO!
ALMACENAMIENTO: No almacene la resina en recipientes abiertos o sin etiquetar. Almacene el
producto en un lugar fresco y seco (15 °F a 100 °F).
ELIMINACIÓN: Elimine el producto de acuerdo con las normativas federales, estatales y locales
aplicables. Todas las unidades HydroPower Ultra requieren el uso de resina de intercambio iónico
con lecho mixto (comúnmente conocida como resina desionizante).
Contenido bajo presión. Puede causar lesiones
graves o la muerte por la ruptura del tanque.
Al arrancar el sistema:
• No exceda la presión de 116 psi (8 Bar).
• Verique que no haya grietas en el sistema.
• Asegúrese de que la cubierta esté en posición de
bloqueo.
• Mantenga abierta la conexión Water OUT y
mantenga hacia abajo la palanca amarilla para
eliminar el aire entrampado en el sistema.
• Para el uso únicamente con agua potable (del grifo).
Antes de brindar servicio al sistema:
• Cierre el grifo de suministro y abra la conexión Water
OUT (salida de agua).
• Desconecte el suministro de agua y deje que se
vacíe el tanque.
• Antes de abrir el tanque, presione la palanca amarilla
de apertura FastLock
™
para eliminar la presión del
tanque, gire a la izquierda las manijas 1/8 de vuelta y
retire la tapa superior usando las manijas.

ESPAGNOL
Introducción
1. Introducción
Gracias por elegir HydroPower Ultra para sus necesidades de agua pura. Usted ha elegido
un producto de alta calidad respaldado por la garantía de satisfacción del cliente del 100%
de Unger. Cuando se utiliza según lo previsto, la unidad producirá agua pura con cero TDS
para la limpieza de cristales en el sitio.
La producción de agua pura, por medio de desionización, está basada en el principio de
intercambio iónico. En este proceso, los minerales responsables de producir manchas se
eliminan del agua.
El uso de HydroPower Ultra tiene las siguientes ventajas:
• Con una barra de lavado y un cepillo alimentados con agua limpiarán ecazmente el
cristal y otras supercies sin necesidad de productos químicos.
• El agua escurrida no tiene que recibir tratamiento alguno y es de uso seguro para plantas
y animales.
• No se necesita electricidad ni fuente de alimentación externa, el sistema funciona con la
presión de la red de abastecimiento de agua.
• Los paquetes de resina se llenan en fábrica con la cantidad exacta de resina de DI con
lecho mixto para un rendimiento óptimo del sistema.
Al igual que con cualquier equipo comercial, se debe tener cuidado al operar y dar
mantenimiento a la unidad. Existe riesgo de daño al sistema debido a:
• Errores de instalación y operación.
• El uso de resina suelta (el sobrellenado y la expansión de la resina dañará la unidad).
• La apertura incorrecta del recipiente.
• El uso de piezas de repuesto que no sean de Unger.
• Realizar modicaciones no autorizadas en la unidad.
• Mantenimiento insuciente.
Use únicamente piezas de repuesto originales genuinas de Unger (de acuerdo con la lista
de repuestos incluida en la página 13).
Para todas las consultas y pedidos de repuestos, es importante proporcionar la información
detallada ubicada en el dispositivo (número de serie y/o número de referencia).

Información de
seguridad
2. Información de seguridad
2.1 Aspectos generales
Tenga presente los reglamentos y normativas aplicables, incluidos todos los procedimientos
de prevención de accidentes. Unger no es responsable por daños a personas, a las áreas de
aplicación ni a los componentes de sistemas de plomería.
Asegúrese de que el área de trabajo tenga suciente escurrimiento de agua.
Cierre el suministro de agua de la tubería cuando no esté en uso.
Asegúrese de que el sistema HydroPower Ultra, incluidos los carros, estén correctamente
asegurados a la plataforma del carro, remolque o camión durante el transporte.
El usuario debe cumplir todos los requisitos locales, estatales/provinciales, federales de
licencia y registro y debe adherirse estrictamente a todas las leyes laborales locales, estatales/
provinciales y federales aplicables, y también a los códigos y estándares de seguridad.
2.2 Uso previsto
Este sistema puede ser peligroso si no está instalado correctamente, si no se le brinda un
mantenimiento regular o no se utiliza de la manera prevista. Use este sistema solo para que
el agua a tratar alcance una calidad de agua óptima para la limpieza de cristales y supercies.
Está prohibido cualquier otro uso, especialmente el tratamiento del agua para la producción
de alimentos (por ejemplo, bebidas).
2.3 Temperaturas, presiones y conexiones de funcionamiento
El sistema debe estar protegido contra el congelamiento. Las temperaturas en el área de
operación deben ser de al menos 15 °F. La temperatura del agua no debe exceder los 86 °F,
y la presión máxima de operación es de 116 psi (8 Bar).

ESPAGNOL
Información de
seguridad
2.4 Peligros generales
Lea y cumpla las normativas ANSI IWCA 1-14.1 (Seguridad para la limpieza de ventanas).
El agua puricada se suministra a la barra alimentada por agua por medio de mangueras
del sistema HydroPower Ultra. Esto introduce un riesgo de tropiezo tanto para el trabajador
como para el público en general. Identique el área de trabajo con los letreros apropiados.
Cualquier supercie que se humedezca debe ser identicada con los letreros apropiados
para dirigir a los peatones y a los trabajadores lejos del área de trabajo. Durante el invierno,
es importante evitar el encharcamiento de agua, la cual podría congelarse, y crear así un
riesgo peligroso de resbaladuras.
Peligros generales asociados con el uso de barras alimentadas por agua y equipos de
desionización1:
• Presenta riesgos de tropiezo para el público en general cuando se utilizan mangueras.
• Hay riesgos de resbaladuras en los trayectos húmedos.
• Riesgo de resbaladura para el operador al estar concentrado en el trabajo.
• Caídas desde sitios altos al trabajar en techos planos.
• Electrocución causada por las barras que entran en contacto con fuentes de energía
eléctrica elevadas.
• Lesiones a otros por barras que caen o telas del edicio que pueden desprenderse.
• Lesiones a otros causadas por barras que caen debido a la manipulación errónea o por el
fallo de la barra misma.
• Lesiones debidas a la manipulación manual errónea de barras y otros equipos.
• Riesgos de transportar tanques, sistemas y equipos que están sobrecargados, son
inestables, no están sujetados o están instalados erróneamente dentro de un vehículo.
1: British Window Cleaning Academy (BWCA): Seguridad en la limpieza de ventanas utilizando sistemas de barras con
alimentación por agua.

3
2
5
7a
7b
1
2
3
44
5
6
8
Descripción general
del sistema
3. Descripción general del sistema
3.1 ¿Qué es el agua pura?
El agua pura es agua en su forma más pura, procesada físicamente para eliminar los
minerales que de otro modo provocarían manchas y vetas de cal. Estas impurezas se
denominan TDS (Total de sólidos disueltos) y se miden en ppm (partes por millón). El agua
se considera 100 % desmineralizada o pura cuando su TDS medido es de 0 ppm. EL TDS
promedio del agua potable es de 180 ppm.
3.2 HydroPower Ultra
verde = posición superior
en todas las unidades
rojo = posición central
e inferior en UHP3C
1. Conexión de entrada de agua
(Water IN), latón cromado,
incluida la válvula
2. Conexión de salida de agua
(Water OUT), latón cromado
3. Palanca de apertura FastLock
para liberar la presión en el
tanque y abrir el tanque
4. Tapa superior con asas para
transportar y abrir el sistema
5. Medidor de TDS para vericar la
calidad del agua
6. Tanque
7. Paquete de Ultra Resina
8. Carro (solo UHP3C)
3.3 Paquetes
de Ultra
Resina

ESPAGNOL
4. Instalación y operación
4.1 Configuración de la nueva máquina
• Desempaque la unidad: Inspeccione la unidad HydroPower Ultra y todos sus
componentes. Lea las advertencias y las instrucciones de operación.
• Inspección y alcance de la entrega: Consulte la ilustración; lleve a cabo una inspección
visual y prepare un inventario de los artículos siguientes que deben haber sido enviados con
el sistema, y a continuación pruebe el funcionamiento del sistema:
• Medidor de TDS (encendido/apagado)
• Palanca FastLock (amarilla). Presione la palanca, gírela a la izquierda y retire el conjunto
de la tapa superior.
• Paquetes de Ultra Resina instalados en la unidad.
- UHPR1 - Un paquete verde
- UHPR2 - Tres paquetes verdes
- UHPR3 - Un paquete verde y dos rojos
• Accesorios de conexión instalados en la unidad.
• Carro, ruedas y sistema de sujeción del depósito (si se compra con carro).
• Conexión de suministro de agua
• Temperatura del agua de entrada, máx. 86 °F
• Temperatura en el sitio 41 °F a 104 °F; y no en las inmediaciones de fuentes de calor o
expuesta a la luz directa del sol.
Instalación y operación

A
C
B
D
Puesta en marcha
4.2 Puesta en marcha
1. LOCALIZAR EL ABASTECIMIENTO DE AGUA EN EL SITIO DE TRABAJO
Unger recomienda que antes de trabajar se verique el suministro de agua en el lugar de trabajo para
determinar el nivel de TDS (total de sólidos disueltos). Los niveles más elevados de TDS reducen la
capacidad del sistema.
• Inspeccione el sistema. Asegúrese de que los Paquetes de Resina Ultra de Unger estén
correctamente instalados: el paquete de resina rojo solo se utiliza en una unidad de tanque grande y
se coloca en la posición central e inferior. El Paquete de Resina verde se utiliza en todas las unidades
y se coloca en la posición superior. NOTA: El rendimiento de HydroPower Ultra se optimiza cuando
se utiliza con los paquetes de resina Ultra. NUNCA use resina suelta ya que puede dañar el sistema.
• Coloque el sistema en posición vertical.
• Elija una ubicación estable en el lugar.
2. CONECTE LA MANGUERA DE LA BARRA DE LAVADO ALIMENTADA POR AGUA
• Conecte la manguera de la barra de lavado alimentada por agua en la conexión Water OUT (g. A).
• Asegúrese de que todas las válvulas de paso (on/o) estén en posición “ABIERTA” al llenar el
sistema.
3. CONECTE EL SUMINISTRO DE AGUA (MANGUERA DE JARDÍN) A LA CONEXIÓN WATER IN
• Enrosque la válvula de paso (On/O) a la manguera de jardín antes de conectar el suministro de agua
(g. B).
• Acople directamente la válvula de paso (On/O) en la conexión WATER IN en la base de la unidad
(g. C).
4. ABRA EL SUMINISTRO DE AGUA DE ALIMENTACIÓN
• Cuando el agua comience a salir de la unidad, active el medidor de TDS e inspeccione la calidad
del agua pura (g. D). Una lectura de ‘0’ es óptima e indica que el sistema está funcionando
correctamente. Cuando el medidor de TDS alcance 10 ppm o más, se recomienda sustituir la resina.
• Ajuste el ujo en el cabezal del cepillo de la barra de lavado alimentada por agua mediante lo
siguiente:
- Válvula de agua del grifo o,
- Válvula de control de la barra de lavado alimentada por agua (on/o) (si corresponde).
This manual suits for next models
1
Table of contents
Languages:
Other unGer Cleaning Equipment manuals

unGer
unGer OmniClean User manual

unGer
unGer HYDRO POWER ULTRA User manual

unGer
unGer RINSE 'N' GO PLUS User manual

unGer
unGer CleanXpress User manual

unGer
unGer nLite Hydro Power HP06T User manual

unGer
unGer OmniClean CLBK1D User manual

unGer
unGer OmniClean User manual

unGer
unGer Hydro Power Ultra UNP01 User manual

unGer
unGer CLBK1 User manual

unGer
unGer nLITE POWER PAD User manual