V2 STARK6 User manual

ZIS549
EDIZ. 01/09/2022
STARK6
D
NICHT UMKEHRBARER
ELEKTROMECHANISCHER
ANTRIEB FÜR FLÜGELTORE
NL
ELEKTROMECHANISCHE,
ONOMKEERBARE LINEAIRE
MOTOR VOOR HEKKEN MET
VLEUGELS
PL
ELEKTROMECHANICZNY
NIEODWRACALNY SIŁOWNIK DO
BRAM SKRZYDŁOWYCH
I
ATTUATORE ELETTROMECCANICO
IRREVERSIBILE PER CANCELLI A
BATTENTE
GB
IRREVERSIBLE
ELECTROMECHANICAL
ACTUATOR FOR SWING GATES
F
OPERATEUR ELECTROMECANIQUE
IRREVERSIBLE POUR
PORTAILS BATTANTS
E
OPERADOR ELECTROMECÁNICO
IRREVERSIBLE PARA
CANCELAS BATIENTES

117 1030
110
80
200
10
80
50
R10
Ø12,2
R20
21 179
10
150
120
163
13515
70
15
30
10
Ø35
Ø12,2
R5
Ø39
Ø19,8
150
120
55
25
10

ENGLISH
- 11 -
IMPORTANT REMARKS
mPrior to proceeding with installation, it is essential the
instructions be read in full, since they contain important
information regarding safety, installation, use and
maintenance.
AUTOMATION MUST BE IMPLEMENTED IN COMPLIANCE
WITH THE EUROPEAN REGULATIONS IN FORCE:
EN 60204-1, EN 12453, EN 13241-1, EN 12635
• The installer must provide for a device (es. magnetotermical
switch) ensuring the omnipolar sectioning of the equipment
from the power supply. The standards require a separation of
the contacts of at least 3 mm in each pole (EN 60335-1).
• The plastic case has an IP44 insulation; to connect flexible or
rigid pipes, use pipefittings having the same insulation level.
• Installation requires mechanical and electrical skills, therefore it
shall be carried out by qualified personnel only, who can issue
the Compliance Certificate concerning the whole installation
(Machine Directive 2006/42/CEE, Annex IIA).
• Also the automation upstream electric system shall
comply with the laws and rules in force and be carried out
workmanlike.
• We recommend to make use of an emergency button, to be
installed by the automation (connected to the control unit
STOP input) so that the gate may be immediately stopped in
case of danger.
• For correct installation of the system, we recommend
following the instructions issued by UNAC very carefully.
• This instruction manual is only for qualified technicians, who
specialize in installations and automations.
• The contents of this instruction manual do not concern the
end user.
• Every programming and/or every maintenance service should
be done only by qualified technicians.
• Anything not expressly described in these instructions is
prohibited; unforeseen uses may be a source of danger to
people and property.
• Do not install the product in explosive environments and
atmospheres: the presence of inflammable gases or fumes is a
serious safety hazard.
• Do not make any modifications to any part of the automation
device, or the accessories connected to it, unless described in
this manual.
• Any other modifications will void the warranty on the product.
• The installation steps should be conducted so as to avoid rainy
weather, which can expose electronic circuits to dangerous
water seepage.
• All operations requiring the casing of the device to opened
should be performed with the control unit disconnected from
the electricity supply and with a warning notice displayed, for
example: ”CAUTION, MAINTENANCE IN PROGRESS”.
• Avoid exposing the device close to sources of heat and flame.
• In the event of interventions on automatic or differential
breakers or fuses, it is essential that faults be identified and
resolved prior to resetting. In the case of faults that cannot
be resolved using the information to be found in this manual,
consult the V2 customer assistance service.
• V2 declines all responsibility for failure to comply with good
construction practice standards in addition to structural
deformation of the gate that might occur during use.
• V2 reserves the right to make modifications to the product
without prior warning.
• Installation/maintenance personnel should wear individual
protection devices (IPDs), such as overalls, safety helmets,
boots and gloves.
• The ambient operating temperature should be that indicated
in the technical characteristics table.
• The automation device should be shut down immediately in
the event of any anomalous or hazardous situation; the fault
or malfunction should be immediately reported to the person
responsible.
• All safety and hazard warnings on the machinery and
equipment should be complied with.
• Electromechanical actuators for gates are not intended to be
used by people (including children) with diminished physical,
sensory or mental capacity, or lacking in experience or
knowledge, unless they are under supervision or have been
instructed in use of the actuator by a person responsible for
safety.
V2 has the right to modify the product without previous
notice; it also declines any responsibility to damage or
injury to people or things caused by improper use or wrong
installation.
DISPOSAL OF THE PRODUCT
As for the installation operations, even at the end of this product’s
life span, the dismantling operations must be carried out by
qualified experts.
This product is made up of various types of materials: some can be
recycled while others need to be disposed of. Find out about the
recycling or disposal systems envisaged by your local regulations
for this product category.
Important! – Parts of the product could contain pollutants or
hazardous substances which, if released into the environment,
could cause harmful effects to the environment itself as well as to
human health.
As indicated by the symbol opposite, throwing away this product
as domestic waste is strictly forbidden. So dispose of it as
differentiated waste, in accordance with your local regulations,
or return the product to the retailer when you purchase a new
equivalent product.
Important! – the local applicable regulations may envisage heavy
sanctions in the event of illegal disposal of this product.
TECHNICAL SERVICE
For any installation problem please contact our Customer Service
at the number +39-0172.812411 operating Monday to Friday
from 8:30 to 12:30 and from 14:00 to 18:00.

ENGLISH
- 12 -
PRELIMINARY CHECKS AND IDENTIFICATION OF THE TYPE TO BE USED
It should be remembered that the device does not compensate for defects caused by improper installation, or poor maintenance, thus, prior
to proceeding with installation, ensure that the structure is suitable and meets current standards and, if necessary, perform any structural
modifications aimed at the implementation of safety gaps and the protection or segregation of all crushing, shearing and transit zones, and
verify that:
• Your gate is equipped with a central latch.
• The gate has no friction points, either during closing or opening.
• The gate is well balanced, i.e. there is no tendency to move spontaneously when stopped in any position.
• The position identified for fixing the motor reducer allows easy and safe manual manoeuvring, compatible with the
size of the motor reducer itself.
• The support on which the automation device will be fixed is solid and durable.
• The mains power supply to which the automation device is connected has a dedicated safety earthing system and differential breaker
with tripping current less than or equal to 30 mA (the breaker gap distance should be greater than or equal to 3 mm).
Warning: The minimum safety level depends on the type of use; please refer to the following outline:
GROUP 1 - Only a limited number of people are authorised for use, and closure is not in a public area. Examples of this type are gates inside
business premises, where the sole users are employees, or a part of them who have been suitably informed.
GROUP 2 - Only a limited number of people are authorised for use, but in this case, closure is in a public area. An example of this may be a
company gate that accesses onto a public street, and which is only used by employees.
GROUP 3 - Anyone can use the automated closure, which is thus located on public land. For example the access gate to a supermarket or
an office, or a hospital.
PROTECTION A - Closure is activated by means of a control button with the person present, i.e. with maintained action.
PROTECTION B - With the person present, closure is activated by a command controlled by means of a key-switch or the like, in order to
prevent use by unauthorised persons.
PROTECTION C - Restricts the force of the leaf of the door or gate. I.e., in the case of the gate striking an obstacle, the impact force must
fall within a curve established by the regulations.
PROTECTION D - Devices, such as photocells, capable of detecting the presence of people or obstacles. They may be active on just one side
or on both sides of the door or gate.
PROTECTION E - Sensitive devices, such as footboards or immaterial barriers, capable of detecting the presence of a person, and installed in
such a way that the latter cannot be struck in any way by a moving leaf or panel. These devices should be active within the entire “danger
zone” of the gate. The Machinery Directive defines “Danger Zone” as any zone surrounding and/or near machinery where the presence of
an exposed person constitutes a risk to the health and safety of that person.
The risk analysis should take into consideration all danger zones for the automation device, which should be appropriately
protected and marked.
In a clearly visible area, apply a sign with information identifying the motorised door or gate.
The installer should provide the user with all the information relating to automatic operation, emergency opening and
maintenance of the motorised door or gate.
CLOSURE USE TYPE
TYPE OF ACTIVATION
COMMANDS
GROUP 1
Informed people
(use in private area)
GROUP 2
Informed people
(use in public area)
GROUP 3
Informed people
(unlimited use)
Man-present command A B Not possible
Remote control and closure in
view (e.g. infrared)
C or E C or E C and D or E
Remote control and closure not
in view (e.g. radio)
C or E C and D or E C and D or E
Automatic control
(e.g. timed closure control)
C and D or E C and D or E C and D or E

ENGLISH
- 13 -
EU DECLARATION OF CONFORMITY
AND DECLARATION OF
INCORPORATION OF PARTLY
COMPLETED MACHINE
Declaration in accordance with Directives: 2014/35/UE (LVD);
2014/30/UE (EMC); 2006/42/CE (MD) ANNEX II, PART B
The manufacturer V2 S.p.A., headquarters in Corso Principi di
Piemonte 65, 12035, Racconigi (CN), Italy
Under its sole responsibility hereby declares that:
the partly completed machinery model(s):
STARK6-24V, STARK6-230V
Description: electromechanical actuator for gates
• is intended to be installed on gates, to create a machine
according to the provisions of the Directive 2006/42/EC.
The machinery must not be put into service until the final
machinery into which it has to be incorporated has been
declared in conformity with the provisions of the Directive
2006/42/EC and 89/106/CE.
• is compliant with the applicable essential safety requirements
of the following Directives:
Machinery Directive 2006/42/EC (annex I, chapter 1)
Low Voltage Directive 2014/35/EU
Electromagnetic Compatibility Directive 2014/30/EU
Directive RoHS-3 2015/863/EU
The relevant technical documentation is available at the national
authorities’ request after justifiable request to:
V2 S.p.A., Corso Principi di Piemonte 65, 12035, Racconigi (CN),
Italia
The person empowered to draw up the declaration and to provide
the technical documentation:
Sergio Biancheri
Legal representative of V2 S.p.A.
Racconigi 01/06/2019
USE LIMITATIONS
Before installing the product, check
that the sizes and the weight of the
gate leaf are within the limits stated in
CHART 1.
kg - maximum gate leaf weight
m - maximum gate leaf length
mWARNING
• Leaves exceeding 5 metres
should not be panelled.
• Solenoid latch required for 4 m
and above.
• Over 5 m, mechanical stops on
the ground are required. 0 1000
100
200
300
400
kg
500
600
700
800
2000 3000 4000
m
5000 6000 7000
0 1000
100
200
300
400
kg
500
600
700
800
2000 3000 4000
m
5000 6000 7000
STARK6-24V
STARK6-230V
CHART 1

ENGLISH
- 14 -
TECHNICAL DATADESCRIPTION OF THE PRODUCT
This product has been designed to automate gates or
doors with leaf opening, for residential or industrial use.
mCAUTION!
Any other use different to that described and in ambient
conditions different to those set out in this manual is to be
considered improper and forbidden!
The product is an electromechanical gear motor, equipped
with motor and an endless screw reduction gear.
The gear motor is powered by the external control unit to
which it is connected.
In the event of a black out, it is possible to move the gate
leaves by hand, unblocking the gear motor manually.
Fig. 1 shows all the components provided in the package:
a-electromechanical gear motor
b - front bracket and plate (for fixing the gear motor to
the gate leaf)
c - rear bracket and plate (for fixing the gear motor to the
wall)
d - metal parts (screws, washers, etc.)
e-keys to manually unlock the gear motor
STARK6-24V STARK6-230V
Max. leaf lenght m 6 6
Max. leaf weight Kg 750 750
Power supply Vdc 24 230
Idling current A 0,8 1
Full load current A 7 1,2
Electric power W 170W 240W
Opening time of the leaf 0÷90° s 28 25
Max travel mm 540 540
Operating speed (unloaded) m/s 0,016 0,016
Operating speed (full load) m/s 0,012 0,014
Maximum thrust N 2400 2000
Working temperature °C -20 ÷ +55 -20 ÷ +55
Protection IP 44 44
Working cycle % 80 30
Motor weight Kg 9 10
a
d
e
b
c
FIG.1

ENGLISH
- 15 -
INSTALLATION LAYOUT
1 1D
E
3
A
B
C
2
56
4
A
B
C
D
E
1
2
3
4
5
6
Key switch
Pillar photocells
Pillar-mounted digital radio switch
Safety edges
ECO-LOGIC system (only with STARK6-24V and CITY2+)
Motor
Control unit
Transmitter
Receiving module
Photocells
Flashing light
COMPONENTS ADDITIONAL ACCESSORIES
LENGTH OF THE CABLE < 10 metres from 10 to 20 metres from 20 to 30 metres
Power supply (230V) 3G x 1,5 mm23G x 1,5 mm23G x 2,5 mm2
24V motor power supply 2G x 1,5 mm22G x 1,5 mm22G x 2,5 mm2
24V motor power supply 2G x 1,5 mm22G x 1,5 mm22G x 2,5 mm2
Photocells (TX) 2 x 0,5 mm22 x 0,5 mm22 x 0,5 mm2
Photocells (RX) 4 x 0,5 mm24 x 0,5 mm24 x 0,5 mm2
Key switch 2 x 0,5 mm22 x 0,5 mm22 x 0,5 mm2
Safety edges 2 x 0,5 mm22 x 0,5 mm22 x 0,5 mm2
Flashing light 2 x 1,5 mm22 x 1,5 mm22 x 1,5 mm2
Antenna (integrated into the flashing light) RG174 RG174 RG174
ECO-LOGIC (accumulator unit) 2 x 1,5 mm2- -
ECO-LOGIC (solar panel) 2 x 1 mm2- -

ENGLISH
- 16 -
INSTALLATION MEASURES
To carry out a proper installation of the operator parts as well as
to ensure the best automation performance, the measurement
levels shown in the following table shall be complied with.
Change the gate structure to adapt it to one of the cases in the
table, if necessary.
mATTENTION!
• Make sure that the door is able to open at the desired angle
without impediments
• The front bracket must always be mounted to its maximum
length (173 mm) therefore it must NOT be cut!
CAUTION: Failure to comply with the bracket installation
distances may lead to automation operation faults, such as:
- Cyclical movements and accelerations at some positions
of the stroke.
- Increased motor noise.
- Limited opening, or no opening at all (in case of
counterlever fixed motor).
A
E
D (945mm)
W

ENGLISH
- 17 -
Before it can be fixed to the wall, the bracket must be welded to
the fastening plate (Fig. 3); the bracket may be cut to the desired
length, adjusting distances Aand Eaccordingly
NOTE - The bracket supplied with the gearmotor is 180 mm
long
mWARNING! Before fixing the rear bracket, make sure
that the front bracket will be fixed to a solid position of
the gate leaf; the front bracket will have to be secured at a
different height than the rear bracket (Fig. 4).
28 mm
Fix the bracket in place using suitable plugs, screws and washers
(not supplied)
INSTALLATION OF THE FRONT FIXING
BRACKET
1. For the installation of the front bracket to the gate leaf, refer
to distance D(fig. 2).
2. Define the front bracket installation height in accordance with
fig. 4.
3. Fix the bracket to the solid section of the gate leaf.
FIG.3
FIG.4
gW [mm] E [mm] A [mm]
90°
20 200
if S > 20
A = 80 + (S - 20)
if S < 0
A = 80
30 210
40 220
50 230
60 240
70 250
80 260
90 270
100 280
110 290
120 300
130 310
140 320
150 330
160 340
170 350
180 360
190 370
200 380
gW [mm] E [mm] A [mm]
100°
20 200
A = 120 + S
30 210
40 220
50 230
60 240
70 250
80 260
90 270
100 280
110 290
120 300
130 310
gW [mm] E [mm] A [mm]
110°
20 200
A = 155 + S
30 210
40 220
50 230
60 240

ENGLISH
- 18 -
SECURING THE GEARMOTOR TO THE
FIXING BRACKETS
1. Secure the gearmotor to the rear bracket:
NOTE: if the rear bracket is not completely level, the
back tilting section can help compensate for any axis
misalignments between the two brackets (+/-5°).
- 5°
+ 5°
2. Secure the gearmotor to the bracket as shown in fig. 6, using
the screw, washer and nut supplied;
3. Fully tighten the nut and then loosen it again by approximately
1/10 of a turn, to allow a minimum clearance between the
parts.
1
2
4. Secure the gearmotor to the front bracket.
5. Secure the gearmotor to the bracket as shown in fig. 7, using
the screw and the washer supplied.
6. Fully tighten the screw.
1
2
3
FIG.5
FIG.6
FIG.7

ENGLISH
- 19 -
ADJUST OF THE LIMIT SWITCHES
1. Release the gearmotor as shown in fig. 8.
13
24
2. Remove the 2 screws underneath the handle and remove the
cover as shown in fig. 9.
1
2
3. Manually move the gate leaf until the mechanical stop screw is
visible; loosen the screw (fig. 10)
4. Manually move the gate leaf to the desired open position.
5. Move the mechanical stop against the pin and tighten the
screw (fig. 11).
6. Now repeat the procedure by manually moving the gate leaf
to the maximum closed position, to adjust the closing limit
switch (fig. 12).
1
7. Replace the cover and tighten the two screws.
8. Lock the gearmotor..
FIG.8 FIG.11
FIG.12
FIG.9
FIG.10

ENGLISH
- 20 -
FIG.13
FIG.14
FIG.15
ELECTRICAL CONNECTIONS
mCAUTION!
• A wrong connection can cause faults or danger; therefore
follow scrupulously the connections set out.
• Perform the connection operations when the electricity is off.
To connect the gear motor to the control unit, proceed as follows:
1. Remove the lid of the gear motor as shown in fig. 13.
1
2
2. Loosen the cableway of the gear motor and insert the
connecting cables inside it (fig. 14)
1
2
3. Connect the various wires and grounding cable, exactly as
shown in the wiring diagram of fig. 15
M
ES128700
M
COM CHAP
EMTO.4870
230V
24V
4. Replace lid on gear motor.
To check the connections, direction of rotation of the motor,
phase shift in the movement of the leaves and setting the
limit switch, refer to the instructions manual of the control
unit.
Other manuals for STARK6
1
Table of contents
Other V2 Controllers manuals
Popular Controllers manuals by other brands

Dell
Dell Dial Totem user guide

WAREMA
WAREMA 1MPF.4 UP Short description

Danfoss
Danfoss erc 112 user guide

Lumenpulse
Lumenpulse Lumenstudio user manual

Greenwood Air Management
Greenwood Air Management GRF1 manual

Mitsubishi Electric
Mitsubishi Electric MEsoftstart/I01 USERS, INSTALLATION & INSTRUCTION MANUAL