V2 CALYPSO Series User manual

- 1 -
IL 186
EDIZ. 10/09/2018
CALYPSO
I
ATTUATORE ELETTROMECCANICO
IRREVERSIBILE PER CANCELLI A
BATTENTE
GB
IRREVERSIBLE
ELECTROMECHANICAL
ACTUATOR FOR SWING GATES
F
OPERATEUR
ELECTROMECANIQUE
IRREVERSIBLE POUR PORTAILS
BATTANTS
E
OPERADOR ELECTROMECÁNICO
IRREVERSIBLE PARA CANCELAS
BATIENTES
P
ACTUADOR ELECTROMECÂNICO
IRREVERSÍVEL PARA PORTÕES DE
BATENTE
D
NICHT UMKEHRBARER
ELEKTROMECHANISCHER
ANTRIEB FÜR FLÜGELTORE
NL
ELEKTROMECHANISCHE,
ONOMKEERBARE LINEAIRE
MOTOR VOOR HEKKEN MET
VLEUGELS
PL
ELEKTROMECHANICZNY
NIEODWRACALNY SIŁOWNIK DO
BRAM SKRZYDŁOWYCH
H
VISSZAFORDÍTHATATLAN
ELEKTRO-MECHANIKUS
MŰKÖDTETŐ LENGŐ KAPUKHOZ
RU
НЕРЕВЕРСИВНЫЙ
ЭЛЕКТРОМЕХАНИЧЕСКИЙ
ПРИВОД ДЛЯ РАСПАШНЫХ
ВОРОТ

177 mm120 mm
A
B
C
ø12,5 mm
ø13 mm
120 mm59,5 mm
6 mm
6 mm
10 mm
8,5 mm
80 mm
50 mm
CALYPSO 400 500 600
A819 944 1044
B762 887 987
C1162 1387 1644

ENGLISH
- 7 -
IMPORTANT REMARKS
mPrior to proceeding with installation, it is essential the
instructions be read in full, since they contain important
information regarding safety, installation, use and
maintenance.
AUTOMATION MUST BE IMPLEMENTED IN COMPLIANCE
WITH THE EUROPEAN REGULATIONS IN FORCE:
EN 60204-1, EN 12445, EN 12453, EN 13241-1, EN 12635
• The installer must provide for a device (es. magnetotermical
switch) ensuring the omnipolar sectioning of the equipment
from the power supply. The standards require a separation of
the contacts of at least 3 mm in each pole (EN 60335-1).
• The plastic case has an IP44 insulation; to connect flexible or
rigid pipes, use pipefittings having the same insulation level.
• Installation requires mechanical and electrical skills, therefore it
shall be carried out by qualified personnel only, who can issue
the Compliance Certificate concerning the whole installation
(Machine Directive 2006/42/CEE, Annex IIA).
• Also the automation upstream electric system shall
comply with the laws and rules in force and be carried out
workmanlike.
• We recommend to make use of an emergency button, to be
installed by the automation (connected to the control unit
STOP input) so that the gate may be immediately stopped in
case of danger.
• For correct installation of the system, we recommend
following the instructions issued by UNAC very carefully.
• This instruction manual is only for qualified technicians, who
specialize in installations and automations.
• The contents of this instruction manual do not concern the
end user.
• Every programming and/or every maintenance service should
be done only by qualified technicians.
• Anything not expressly described in these instructions is
prohibited; unforeseen uses may be a source of danger to
people and property.
• Do not install the product in explosive environments and
atmospheres: the presence of inflammable gases or fumes is a
serious safety hazard.
• Do not make any modifications to any part of the automation
device, or the accessories connected to it, unless described in
this manual.
• Any other modifications will void the warranty on the product.
• The installation steps should be conducted so as to avoid rainy
weather, which can expose electronic circuits to dangerous
water seepage.
• All operations requiring the casing of the device to opened
should be performed with the control unit disconnected from
the electricity supply and with a warning notice displayed, for
example: ”CAUTION, MAINTENANCE IN PROGRESS”.
• Avoid exposing the device close to sources of heat and flame.
• In the event of interventions on automatic or differential
breakers or fuses, it is essential that faults be identified and
resolved prior to resetting. In the case of faults that cannot
be resolved using the information to be found in this manual,
consult the V2 customer assistance service.
• V2 declines all responsibility for failure to comply with good
construction practice standards in addition to structural
deformation of the gate that might occur during use.
• V2 reserves the right to make modifications to the product
without prior warning.
• Installation/maintenance personnel should wear individual
protection devices (IPDs), such as overalls, safety helmets,
boots and gloves.
• The ambient operating temperature should be that indicated
in the technical characteristics table.
• The automation device should be shut down immediately in
the event of any anomalous or hazardous situation; the fault
or malfunction should be immediately reported to the person
responsible.
• All safety and hazard warnings on the machinery and
equipment should be complied with.
• Electromechanical actuators for gates are not intended to be
used by people (including children) with diminished physical,
sensory or mental capacity, or lacking in experience or
knowledge, unless they are under supervision or have been
instructed in use of the actuator by a person responsible for
safety.
V2 has the right to modify the product without previous
notice; it also declines any responsibility to damage or
injury to people or things caused by improper use or wrong
installation.
DISPOSAL OF THE PRODUCT
As for the installation operations, even at the end of this product’s
life span, the dismantling operations must be carried out by
qualified experts.
This product is made up of various types of materials: some can be
recycled while others need to be disposed of. Find out about the
recycling or disposal systems envisaged by your local regulations
for this product category.
Important! – Parts of the product could contain pollutants or
hazardous substances which, if released into the environment,
could cause harmful effects to the environment itself as well as to
human health.
As indicated by the symbol opposite, throwing away this product
as domestic waste is strictly forbidden. So dispose of it as
differentiated waste, in accordance with your local regulations,
or return the product to the retailer when you purchase a new
equivalent product.
Important! – the local applicable regulations may envisage heavy
sanctions in the event of illegal disposal of this product.
TECHNICAL SERVICE
For any installation problem please contact our Customer Service
at the number +39-0172.812411 operating Monday to Friday
from 8:30 to 12:30 and from 14:00 to 18:00.

ENGLISH
- 8 -
PRELIMINARY CHECKS AND IDENTIFICATION OF THE TYPE TO BE USED
The automation device should not be used until installation, as specified in “Testing and start-up”, has been performed.
It should be remembered that the device does not compensate for defects caused by improper installation, or poor maintenance, thus, prior
to proceeding with installation, ensure that the structure is suitable and meets current standards and, if necessary, perform any structural
modifications aimed at the implementation of safety gaps and the protection or segregation of all crushing, shearing and transit zones, and
verify that:
• The gate is equipped with central and side stops.
• The gate has no friction points, either during closing or opening.
• The gate is well balanced, i.e. there is no tendency to move spontaneously when stopped in any position.
• The position identified for fixing the motor reducer allows easy and safe manual manoeuvring, compatible with the
size of the motor reducer itself.
• The support on which the automation device will be fixed is solid and durable.
• The mains power supply to which the automation device is connected has a dedicated safety earthing system and differential breaker
with tripping current less than or equal to 30 mA (the breaker gap distance should be greater than or equal to 3 mm).
Warning: The minimum safety level depends on the type of use; please refer to the following outline:
GROUP 1 - Only a limited number of people are authorised for use, and closure is not in a public area. Examples of this type are gates inside
business premises, where the sole users are employees, or a part of them who have been suitably informed.
GROUP 2 - Only a limited number of people are authorised for use, but in this case, closure is in a public area. An example of this may be a
company gate that accesses onto a public street, and which is only used by employees.
GROUP 3 - Anyone can use the automated closure, which is thus located on public land. For example the access gate to a supermarket or
an office, or a hospital.
PROTECTION A - Closure is activated by means of a control button with the person present, i.e. with maintained action.
PROTECTION B - With the person present, closure is activated by a command controlled by means of a key-switch or the like, in order to
prevent use by unauthorised persons.
PROTECTION C - Restricts the force of the leaf of the door or gate. I.e., in the case of the gate striking an obstacle, the impact force must
fall within a curve established by the regulations.
PROTECTION D - Devices, such as photocells, capable of detecting the presence of people or obstacles. They may be active on just one side
or on both sides of the door or gate.
PROTECTION E - Sensitive devices, such as footboards or immaterial barriers, capable of detecting the presence of a person, and installed in
such a way that the latter cannot be struck in any way by a moving leaf or panel. These devices should be active within the entire “danger
zone” of the gate. The Machinery Directive defines “Danger Zone” as any zone surrounding and/or near machinery where the presence of
an exposed person constitutes a risk to the health and safety of that person.
The risk analysis should take into consideration all danger zones for the automation device, which should be appropriately
protected and marked.
In a clearly visible area, apply a sign with information identifying the motorised door or gate.
The installer should provide the user with all the information relating to automatic operation, emergency opening and
maintenance of the motorised door or gate.
CLOSURE USE TYPE
TYPE OF ACTIVATION
COMMANDS
GROUP 1
Informed people
(use in private area)
GROUP 2
Informed people
(use in public area)
GROUP 3
Informed people
(unlimited use)
Man-present command A B Not possible
Remote control and closure in
view (e.g. infrared)
C or E C or E C and D or E
Remote control and closure not
in view (e.g. radio)
C or E C and D or E C and D or E
Automatic control
(e.g. timed closure control)
C and D or E C and D or E C and D or E

ENGLISH
- 9 -
EU DECLARATION OF CONFORMITY
AND DECLARATION OF
INCORPORATION OF PARTLY
COMPLETED MACHINE
Declaration in accordance with Directives: 2014/35/UE (LVD);
2014/30/UE (EMC); 2006/42/CE (MD) ANNEX II, PART B
The manufacturer (*) V2 S.p.A., headquarters in Corso Principi di
Piemonte 65, 12035, Racconigi (CN), Italy
Under its sole responsibility hereby declares that:
the partly completed machinery model(s):
CALYPSO400-230V (*), CALYPSO500-230V (*)
CALYPSO600-230V (*)
CALYPSO400-120V (*), CALYPSO500-120V (*)
CALYPSO600-120V (*)
CALYPSO400-24V (*), CALYPSO500-24V (*)
CALYPSO600-24V (*)
Description: electromechanical actuator for gates
• is intended to be installed on gates, to create a machine
according to the provisions of the Directive 2006/42/EC.
The machinery must not be put into service until the final
machinery into which it has to be incorporated has been
declared in conformity with the provisions of the Directive
2006/42/EC and 89/106/CE.
• is compliant with the applicable essential safety requirements
of the following Directives:
Machinery Directive 2006/42/EC (annex I, chapter 1)
Low Voltage Directive 2014/35/EU
Electromagnetic Compatibility Directive 2014/30/EU
Directive ROHS2 2011/65/CE
The relevant technical documentation is available at the national
authorities’ request after justifiable request to:
V2 S.p.A., Corso Principi di Piemonte 65, 12035, Racconigi (CN),
Italia
The person empowered to draw up the declaration and to provide
the technical documentation:
Antonio Livio Costamagna
Legal representative of V2 S.p.A.
Racconigi, il 01/06/2015
(*) made in extra EU Countries on behalf of V2 S.p.A.
TECHNICAL DATA
CALYPSO
400-230V
CALYPSO
500-230V
CALYPSO
600-230V
CALYPSO
400-120V
CALYPSO
500-120V
CALYPSO
600-120V
CALYPSO
400-24V
CALYPSO
500-24V
CALYPSO
600-24V
Max. leaf lenght m 2,5 3 4 2,5 3 4 2,5 3 4
Max. leaf weight Kg 400 500 500 400 500 500 300 400 400
Power supply Vac - Hz 230 - 50 230 - 50 230 - 50 120 - 60 120 - 60 120 - 60 24 Vdc 24 Vdc 24 Vdc
Idling current A 0,8 0,8 0,8 2 2 2 2 2 2
Full load current A 1,2 1,2 1,2 2,8 2,8 2,8 10 10 10
Electric power W 200 200 200 300 300 300 - - -
Opening time of the
leaf 0÷90°
s 22 25 30 22 25 30 22 27 35
Capacitor µF 8 8 8 25 25 25 - - 8
Max travel mm 400 500 600 400 500 600 400 500 600
Operating speed m/s 0,016 0,016 0,016 0,018 0,018 0,018 - - -
Maximum thrust N 2300 2300 2300 2300 2300 2300 2000 2000 2000
Working temperature °C -30 ÷ +50 -30 ÷ +50 -30 ÷ +50 -30 ÷ +50 -30 ÷ +50 -30 ÷ +50 -30 ÷ +50 -30 ÷ +50 -30 ÷ +50
Protection IP 44 44 44 44 44 44 44 44 44
Working cycle % 30 30 30 30 30 30 90 90 90
Motor weight Kg 6,5 6,8 7,1 6,5 6,8 7,1 6,3 6,6 7,1

ENGLISH
- 10 -
INSTALLATION LAYOUT
A
B
C
D
E
1
2
3
4
5
6
Key switch
Pillar photocells
Pillar-mounted digital radio switch
Safety edges
ECO-LOGIC system (only with CALYPSO-24V and CITY2+BC)
Motor
Control unit
Transmitter
Receiving module
Photocells
Flashing light
COMPONENTS ADDITIONAL ACCESSORIES
LENGTH OF THE CABLE < 10 metres from 10 to 20 metres from 20 to 30 metres
Power supply (230V) 3G x 1,5 mm23G x 1,5 mm23G x 2,5 mm2
230V motor power supply 4G x 1,5 mm24G x 1,5 mm24G x 2,5 mm2
24V motor power supply 2G x 1,5 mm22G x 1,5 mm22G x 2,5 mm2
Photocells (TX) 2 x 0,5 mm22 x 0,5 mm22 x 0,5 mm2
Photocells (RX) 4 x 0,5 mm24 x 0,5 mm24 x 0,5 mm2
Key switch 2 x 0,5 mm22 x 0,5 mm22 x 0,5 mm2
Safety edges 2 x 0,5 mm22 x 0,5 mm22 x 0,5 mm2
Flashing light 2 x 1,5 mm22 x 1,5 mm22 x 1,5 mm2
Antenna (integrated into the flashing light) RG174 RG174 RG174
ECO-LOGIC (accumulator unit) 2 x 1,5 mm2- -
ECO-LOGIC (solar panel) 2 x 1 mm2- -
1 1D
3
A
C
2
56
4

ENGLISH
- 11 -
INSTALLATION MEASURES
To carry out a proper installation of the operator parts as well as
to ensure the best automation performance, the
measurement levels shown in the following table shall be
complied with. Change the gate structure to adapt it to one of
the cases in the table, if necessary.
• For the installations OPENING TOWARDS THE INSIDE, refer to
the table at page 62-63
• For the installations OPENING TOWARDS THE OUTSIDE, refer
to the table at page 64-65
mWARNING: In the case of leaf longer than 2 metres, an
electric lock must be fitted to ensure an efficent closing
ACTUATOR FIXING
Choose measures referring to the table you can find in the
previous page, mark them on the pillars and continue as follows:
• Fix the clamps to the pillar and to the gate soldering directly;
if the material does not allow it, it is necessary to solder the
clamps to plates to be fixed to the gate and the pillars by
screws.
• Close the swing.
• Unlock the actuators.
• Position CALYPSO on the brackets and fix the pins no. 1 and
no. 2 with seeger (see the picture).
• Open and close the swings repeatedly manually to verify the
absence of frictions between gate and ground.
mWARNING: in order to avoid damage to the
actuator, please adhere to the following conditions:
• The brackets must be installed at the same height.
• In case of gate completely closed the maximum stroke of arm
Ashould not exceed:
456 mm (CALYPSO400)
556 mm (CALYPSO500)
625 mm (CALYPSO600)
• The minimum stroke of arm Bmust be more than 56 mm (in
case of gate completely open).
A
B

ENGLISH
- 12 -
ELECTRICAL CONNECTIONS
230V / 120V 24V
230V 120V FUNCTION
1YELLOW - GREEN GREEN GND
2GREY WHITE COMMON
3BLACK BLACK CLOSING
4BROWN RED OPENING
24V FUNCTION
1BLACK CLOSING
2RED OPENING
EMERGENCY RELEASE
In case of a blackout, the gate can be operated directly from the
motor. Insert the key supplied in the lock, perform 1/2 of a turn.
To restore the automation, simply rotate the key in closed position
and insert the provided plastic cover onto the lock.
mWARNING: always remember to
connect the earth according to current
standards (EN 60335-1, EN 60204-1).
Avoid tension in the cable during open and
close operations.

- 61 -

- 62 -
γ
B
C
F
g max B [mm] C [mm] F
[mm]
90°
130 130 1010
150 140 1000
170 150 990
190 150 980
200 150 980
210 140 980
250 120 1010
g max B [mm] C [mm] F
[mm]
100°
130 170 970
150 180 960
170 180 960
190 170 970
210 140 990
g max B [mm] C [mm] F
[mm]
110°
130 190 950
150 180 960
160 170 970
CALYPSO 400

- 63 -
g max B [mm] C [mm] F
[mm]
90°
130 170 1200
150 180 1190
170 180 1190
190 190 1180
210 190 1170
230 190 1170
250 180 1170
270 190 1170
290 170 1180
g max B [mm] C [mm] F [mm]
90°
295 280 1290
315 295 1300
335 265 1310
g max B [mm] C [mm] F [mm]
100°
175 190 1390
195 200 1370
215 220 1360
235 235 1350
255 255 1330
275 270 1300
g max B [mm] C [mm] F [mm]
110°
195 200 1370
215 220 1360
235 235 1350
255 250 1335
g max B [mm] C [mm] F
[mm]
100°
130 160 1210
150 170 1200
170 170 1200
200 180 1190
210 170 1190
230 190 1170
250 180 1180
270 160 1200
280 160 1200
g max B [mm] C [mm] F
[mm]
110°
130 170 1200
150 180 1190
170 180 1190
190 190 1180
210 200 1170
220 200 1170
CALYPSO 500
CALYPSO 600

- 64 -
γ
BF
C

- 65 -
g max B [mm] C [mm] F [mm]
80° 110 ÷ 130 90 949
85° 110 ÷ 130 100 967
90° 110 ÷ 130 110 986
95° 110 ÷ 130 120 1006
100° 110 ÷ 130 130 1027
110° 110 ÷ 130 140 1057
g max B [mm] C [mm] F [mm]
80° 130 100 995
85° 130 110 1005
90° 130 120 1015
95° 130 130 1025
100° 130 140 1035
110° 130 150 1045
g max B [mm] C [mm] F [mm]
100° 200 200 1340
220 220 1320
110°
130 130 1380
140 140 1380
160 160 1380
180 180 1360
CALYPSO 400
CALYPSO 500
CALYPSO 600

V2 S.p.A.
Corso Principi di Piemonte 65/67
12035 RACCONIGI CN (ITALY)
Tel. +39 0172 812411 - Fax +39 0172 84050
www.v2home.com
Other manuals for CALYPSO Series
1
This manual suits for next models
3
Table of contents
Other V2 Controllers manuals
Popular Controllers manuals by other brands

Milnor
Milnor MilTouch MWF27Z8 Series Operator's guide

PhaseOne
PhaseOne iX MK 5 Installation and operation guide

Doli
Doli EDC580 Assembly instruction

Walchem
Walchem W600 Series instruction manual

Emerson
Emerson Bettis RGS Q Series Installation, operation and maintenance manual

Loctite
Loctite Single CureJet Operation manual