logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. WE-EF
  6. •
  7. Outdoor Light
  8. •
  9. WE-EF ESC100 LED Series User manual

WE-EF ESC100 LED Series User manual

This manual suits for next models

2

Other WE-EF Outdoor Light manuals

WE-EF EFL540 LED User manual

WE-EF

WE-EF EFL540 LED User manual

WE-EF LSP434 User manual

WE-EF

WE-EF LSP434 User manual

WE-EF RMC320 LED User manual

WE-EF

WE-EF RMC320 LED User manual

WE-EF AFL100 Series User manual

WE-EF

WE-EF AFL100 Series User manual

WE-EF PIA240 LED User manual

WE-EF

WE-EF PIA240 LED User manual

WE-EF PSY414 LED User manual

WE-EF

WE-EF PSY414 LED User manual

WE-EF SLS400 LED Series User manual

WE-EF

WE-EF SLS400 LED Series User manual

WE-EF QRO379 LED User manual

WE-EF

WE-EF QRO379 LED User manual

WE-EF ETC100-GB LED Series User manual

WE-EF

WE-EF ETC100-GB LED Series User manual

WE-EF QRI354 LED User manual

WE-EF

WE-EF QRI354 LED User manual

WE-EF ESC130-FS User manual

WE-EF

WE-EF ESC130-FS User manual

WE-EF DLO229 LED User manual

WE-EF

WE-EF DLO229 LED User manual

WE-EF VFL530 User manual

WE-EF

WE-EF VFL530 User manual

WE-EF ZFY230 LED User manual

WE-EF

WE-EF ZFY230 LED User manual

WE-EF ZA630 User manual

WE-EF

WE-EF ZA630 User manual

WE-EF FLA780 User manual

WE-EF

WE-EF FLA780 User manual

WE-EF FLA740 LED User manual

WE-EF

WE-EF FLA740 LED User manual

WE-EF ZTY630 LED User manual

WE-EF

WE-EF ZTY630 LED User manual

WE-EF KTY234 LED User manual

WE-EF

WE-EF KTY234 LED User manual

WE-EF MRY224 User manual

WE-EF

WE-EF MRY224 User manual

WE-EF ETC130 User manual

WE-EF

WE-EF ETC130 User manual

WE-EF CFY259 LED User manual

WE-EF

WE-EF CFY259 LED User manual

WE-EF LTC440 User manual

WE-EF

WE-EF LTC440 User manual

WE-EF ESC130 User manual

WE-EF

WE-EF ESC130 User manual

Popular Outdoor Light manuals by other brands

Sealey LED37 instructions

Sealey

Sealey LED37 instructions

nordlux VEJERS Mounting instruction

nordlux

nordlux VEJERS Mounting instruction

SImx ELITE LED LHTC637 installation instructions

SImx

SImx ELITE LED LHTC637 installation instructions

GEV CAROLINE 10833 manual

GEV

GEV CAROLINE 10833 manual

Lindby 9949029 Intended use

Lindby

Lindby 9949029 Intended use

HEPER DOGO Side LW6048.585-US Installation & maintenance instructions

HEPER

HEPER DOGO Side LW6048.585-US Installation & maintenance instructions

Maretti VIBE S 14.6080.04.A quick start guide

Maretti

Maretti VIBE S 14.6080.04.A quick start guide

BEGA 84 253 Installation and technical information

BEGA

BEGA 84 253 Installation and technical information

HEPER LW8034.003-US Installation & maintenance instructions

HEPER

HEPER LW8034.003-US Installation & maintenance instructions

HEPER MINIMO Installation & maintenance instructions

HEPER

HEPER MINIMO Installation & maintenance instructions

LIGMAN BAMBOO 3 installation manual

LIGMAN

LIGMAN BAMBOO 3 installation manual

Maretti TUBE CUBE WALL 14.4998.04 quick start guide

Maretti

Maretti TUBE CUBE WALL 14.4998.04 quick start guide

Maxim Lighting Carriage House VX 40428WGOB installation instructions

Maxim Lighting

Maxim Lighting Carriage House VX 40428WGOB installation instructions

urban ambiance UQL1273 installation instructions

urban ambiance

urban ambiance UQL1273 installation instructions

TotalPond 52238 instruction manual

TotalPond

TotalPond 52238 instruction manual

Donner & Blitzen 0-02661479-2 owner's manual

Donner & Blitzen

Donner & Blitzen 0-02661479-2 owner's manual

LIGMAN DE-20023 installation manual

LIGMAN

LIGMAN DE-20023 installation manual

Spectroline MAXIMA ML-3500 Series Operator's manual

Spectroline

Spectroline MAXIMA ML-3500 Series Operator's manual

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

Safety Notice
The manufacturer is discharged from liability when damage
is caused by improper use or installation.
If any luminaire and/or accessory is subsequently modi-
fied, the persons responsible for the modification shall be
considered as manufacturer.
ESC100 LED_060521 / 006-1339
Technical specifications are subject to change.
© WE-EF 2022
we-ef.com
WE-EF LIGHTING USA
Tel +1 724 742 0030
[email protected]
WE-EF LIGHTING
Installation and
Maintenance Instructions for
Inground Uplights
ESC100 LED Series
120-
277 V
ø 12.01
6.30
12.40
ESC140
ø 9.84
5.12
10.43
ESC130
12.40
16.5
4
10.43
14.7
6
ESC140 + BET
ESC130 + BET
14.7
6
10.83
16.5
4
12.80
5.75
ø 0.394 (max.)
ø 0.472-0.748 (max.)
BET13-II - 185-0322 BET14-II - 185-0323
Installation Accessories
Installation Blockouts lb
185-0322 BET13-II-270/375 max. 75W 0.77
185-0323 BET14-II-325/430 max.100W 0.91
Installation Accessories
Sealable junction box
185-1624 SJB130 0.18 lb
Inground Uplight with Installation Blockout
IP67, IK07
Light source
ESC100 ................12 LED 18W / 24 LED 24W*
* Nominal power, for latest data refer to
www.we-ef.com
Class I
ø0.315 –0.335 in
3 x 16 AWG
Installation
The luminaire should be installed and maintained by a
suitably qualified person in compliance with the latest
construction and electrical regulations and relevant
legislation.
The luminaire should not get covered partly or complete.
Dirt on the lens has to get removed.
Do not open the luminaire in humid conditions or during
rain. This will result in condensation forming inside the
luminaire.
In case of questions please contact our technical hot-
line at +1 724 742 0030 (Monday - Friday from 08:00
until 16:00 hours).
Installation Methods
Installation with BET
Ensure that proper drainage is provided for the shown
installation methods.
1) In landscaped areas (soil with gravel base), pic. 1
2) In paved areas (concrete with gravel base), pic. 2
pic. 1 pic. 2
pic. 3 pic. 4 pic. 5 pic. 6
gravel (drainage)
concrete
soil
Phase Two
(Electrical connection, aiming)
4) Switch off mains electrical supply.
5) Check that rating shown on luminaire label conforms
with the mains electrical supply. Observe the maxi-
mum permissible wattage in connection with BET
installation blockouts (refer to table “Installation
Accessories”).
6) Loosen screws Kand remove cover B. Remove
cover Gand lens/gasket assembly H/I by removing
the six countersunk screws J.
Installation without BET
3) In landscaped areas (soil with gravel), pic. 3
4) In landscaped areas (soil with concrete and graval
base), pic. 4
5) In paved areas (concrete), pic. 5
6) In paved areas (concrete with gravel base) see pic. 6
Installation with Blockout BET
Phase One
(During earth or masonry works)
1) Put the mounting ring Eon to the installation
blockout Oin that way, that the connector L lock
into position on the blind rivets S.
2) A suitable recess to be provided to accomodate
installation blockout/mounting ring assembly E/O.
Proceed as follows:
a) Set in position together with supply cable(s) P.
b) Luminaire mounting ring Eto be flush with surface
F(if the floor will be tiled or paved afterwards
leave an appropriate gap).
c) Point arrow Rtowards the object (wall, tree,
column ...) to be illuminated.
3) During ongoing earth and/or masonry works, ensure
that installation blockout/mounting ring assembly
E/O is not damaged and maintains its original
shape. If necessary use a cover plate.
7) Remove the chassis M from the luminaire housing N.
8) Ensure that all surfaces are clean and dry. Then
remove gel bag from aluminium envelope. Place
bag inside the bottom of the luminaire N.
9) Remove the two screws Qfrom mounting ring E.
Open the packaging of the desiccant bag. Place
the bag in the lower part of the luminaire housing.
10) Connect wires of luminaire cable Aand mains
supply cable Pin sealable junction box C(e.g.
WE-EF product no. 185-1624) and/or provided
UL410-D wire nuts. Seal junction box properly.
11) Insert the housing into the blockout. Fix mounting
ring Eto luminaire by inserting two stainless screws
Qand tightening them equally.
12) Assemble in reverse order.
13) Set lens/gasket assembly H/I, cover Gand the six
countersunk screws Jin position as described.
Then, while taking all necessary precautions to
ensure safety:
a) Leave the screws untightened and ignite the lumin-
aire for approx. 30 minutes to allow any moisture
to evaporate.
b) Begin tightening the countersunk screws Jin steps
in a criss-cross pattern, until all six screws are pro-
perly seated and secured. Repeat tightening proce-
dure, again in a criss-cross pattern, for another two
rounds with a torque of 9 Nm.
14) Set luminaire in position while observing to avoid
stress on junction box C, cable Aand cable gland D.
15) Reposition cover Band tighten screws K.