YOKOGAWA 701978 User manual

User's
Manual
Notes
• The contents of this manual are subject to change without prior notice as a result of continuing
improvements to the product’s performance and functionality. The figures given in this manual may
differ from those that actually appear on your product.
• Every effort has been made in the preparation of this manual to ensure the accuracy of its
contents. However, should you have any questions or find any errors, please contact your nearest
YOKOGAWA dealer.
• Copying or reproducing all or any part of the contents of this manual without the permission of
YOKOGAWA is strictly prohibited.
Conventions Used in This Manual
Improper handling or use can lead to injury to the user or damage to the instrument.
This symbol appears on the instrument to indicate that the user must refer to the
user’s manual for special instructions. The same symbol appears in the corresponding
place in the user’s manual to identify those instructions. In the manual, the symbol is
used in conjunction with the word “WARNING” or “CAUTION.”
WARNING Calls attention to actions or conditions that could cause serious or fatal injury to the
user, and precautions that can be taken to prevent such occurrences.
CAUTION Calls attention to actions or conditions that could cause light injury to the user or
damage to the instrument or user’s data, and precautions that can be taken to prevent
such occurrences.
Note Calls attention to information that is important for the proper operation of the
instrument.
Safety Precautions
This product is designed to be used by a person with specialized knowledge. To use this product
correctly and safely, the general safety precautions described herein must be observed during all
phases of operation. YOKOGAWA assumes no liability for the customer’s failure to comply with these
requirements.
This manual is part of the product and contains important information. Keep this manual in a safe
place so that you can refer to it immediately when using the product until you dispose of the product. In
addition, before using the probe, read the manuals of the oscilloscope to thoroughly familiarize yourself
with its specifications and operation.
The following symbols are used on this instrument.
Handle with care. Refer to the user’s manual or service manual. This symbol appears on
dangerous locations on the instrument which require special instructions for proper handling
or use. The same symbol appears in the corresponding place in the manual to identify those
instructions.
Risk of electric shock
Notes about Usage
WARNING
Purpose of the product
The product is used in combination with an oscilloscope to observe and measure electrical
signals. Do not use for any other purpose.
Grounding of the measuring instrument
The protective grounding terminal of the oscilloscope must be connected to ground.
Check the grounding
Before connecting the probe input terminal to the device under measurement, ensure that
the measuring instrument is grounded properly and that the probe’s BNC connector is
connected to the oscilloscope input.
Observe the maximum input voltage
Do not apply a voltage exceeding the input range specified in the specifications between an
input lead and ground or between two input leads. Also, take the set attenuation ratio into
account.
Be careful of electric shock
Never use the probe with wet hands or when the probe itself is wet. Doing so may cause
electric shock. Be careful of electric shock when you connect the probe to the device under
measurement.
Avoid exposed circuitry
To prevent electric shock, remove metal and jewelry such as watches and rings. Do not
touch exposed connections or components when power is present on the device.
Precautions when connecting and disconnecting the probe
Do not disconnect the probe from the oscilloscope while the probe is connected to the
device under measurement. Doing so may cause electric shock.
Do not operate in wet or damp conditions.
To prevent electric shock, do not operate the probe in wet or damp conditions.
Do not operate in explosive atmosphere
To prevent injury or fire hazard, do not operate the probe in an atmosphere of flammable or
explosive gases or vapors.
Do not operate with suspected failures
Stop using the probe if you suspect that the probe is damaged. Consult your nearest
YOKOGAWA dealer.
Do not operate with a damaged signal cable
If the signal cable is torn and the inner metal is exposed or if a color different from the outer
sheath appears, stop using the cable.
Do not disassemble or modify
Do not disassemble or modify the product. YOKOGAWA assumes no liability if you
disassemble or modify the product.
Thank you for purchasing the Model 701978 Differential Probe. This user’s manual explains usage,
specifications, and the handling precautions of the 701978. To ensure correct use, please read this
manual thoroughly before beginning operation. After reading this manual, keep it in a safe place.
IM 701978-01EN
3rd Edition
CAUTION
Application and design of the product
The product has not been designed or manufactured for applications in which high reliability
is required over a long period of time.
Protective structure
The product is not dust or water resistant. Do not use it in areas with a lot of dust or near
water.
Usage and storage environment
Avoid using or storing the product in an environment that does not meet the specifications,
such as direct sunlight, high temperature and humidity, or condensation. Deformation or
insulation deterioration can occur resulting in failure to retain the product specifications.
Handling the probe
Avoid vibration, shock, and static electricity when handling the probe. Do not bend or pull the
cables excessively. Doing so may damage or disconnect the probe.
Operating environmental limitations
The product is a Class A (for industrial environments) product. Operation of the product in
a residential area may cause radio interference in which case the user will be required to
correct the interference.
1. Overview
Model 701978 Differential Probe is a differential input active probe that supports high voltage up to
1.5 kV and high frequency inputs up to 150 MHz. It can be used for oscilloscopes with single-ended
inputs. The attenuation ratio can be switched between 50:1 and 500:1
2. Configuration and Functions
Offset voltage adjustment screw
Overload indicator
Attenuation switch
(50:1/500:1)
To oscilloscope
1. Probe head
Input lead
To device under measurement
Probe cable
Power cable
2. Probe interface unit
4. Extension lead
(black/red, 1 m)
3. Pincher tip
(black/red)
5. 100-Ω resistor
adapter (yellow)
6. 150-Ω resistor
adapter (green)
7. O-ring (8 colors)
8. Manuals
No. Standard Parts Part No. Optional Accessories
(Sold separately)
Part No.
1. Probe head – Long test clip 701906
2. Probe interface unit – Alligator clip (dolphin type) 701954
3. Pincher tip B9852MM(black)/
B9852MN(red)
Fork terminal adapter 758921
Alligator clip (rated 300 V) 758922
4. Extension lead B8099LF(black)/
B8099LG(red)
Alligator clip (rated 1000 V) 758929
Safety terminal adapter 758931
5. 100-Ω resistor adapter (yellow) B8099LJ
6. 150-Ω resistor adapter (green) B8099LK
7. O-ring (8 colors, attached to the
probe cable)
–
8. Manuals (see below) –
Manual Title Manual No. Description
Model 701978 Differential Probe
User’s Manual
IM 701978-01EN This manual. Explains usage,
specifications, and the handling
precautions of the 701978.
Model 701978 Differential Probe
Safety Instructions
IM 701978-02FR The warnings and cautions in French to
supplement the IM 701978-01EN
Safety Instruction Manual IM 00C01C01-01Z1 Safety manual (European languages)
Inquiries PIM 113-01Z2 List of worldwide contacts
The “EN”, “FR”, “Z1”, and “Z2” in the manual numbers are the language codes.
Power Supply
Power is supplied from the probe power terminal on the connected oscilloscope or the power supply
unit (model 701934 or model 700938, sold separately) through the power cable of this cable.
Attenuation Switch
Switches the attenuation ratio between 50:1 and 500:1. When measuring a signal of 150 V or less,
select 50:1 for measurement of higher resolution and less noise. When measuring a signal above
150 V, select 500:1.
Overload Indicator
When the differential input exceeds the following value, the indicator lights.
±150 V at 50:1 attenuation ratio.
±1500 V at 500:1 attenuation ratio.
Offset voltage adjustment screw
This screw adjusts the internal variable resistor. The residual offset voltage can be adjusted using
an appropriate screwdriver.
3. Operating Procedure
WARNING
• Use this probe only with YOKOGAWA’s oscilloscopes. Even with YOKOGAWA’s
oscilloscopes, this probe can be used only when specified as an accessory.
• Do not apply a voltage exceeding the maximum voltage values between the input and
ground. Failure to follow this precaution may cause accidents, such as electric shock or
damage to the instruments.
• To use the probe, first connect to the oscilloscope and then to the device under
measurement. After use, turn off the power to the device under measurement, disconnect
the probe from the device under measurement first, and then disconnect from the
oscilloscope.
CAUTION
• This probe is designed to measure the voltage difference between two points on the
device under measurement. It does not electrically isolate the device under measurement
from the measuring instrument.
• When cleaning the probe, wipe with a piece of soft cloth to prevent damaging the probe.
Do not immerse the probe body in liquid. Do not use abrasive cleaners or volatile solvents
such as benzine on the probe.
Model 701978
Differential Probe
3rd Edition : January 2022 (YMI)
All Rights Reserved, Copyright © 2021, Yokogawa Test & Measurement Corporation
Printed in Japan
IM 701978-01EN 1/2
5 The equipment is for measurement category III (CAT III). Do not use it with measurement
category IV (CAT IV). When using devices or accessories with different measurement categories,
the lower measurement category applies. See below for definitions of measurement categories.
Measurement Category Definition
Measurement category Other “O” Measurement category Other “O” applies to
measurement of a circuit that is not connected directly
to the main power source.
Measurement category II (CAT II) CAT II applies to measurement of electrical equipment
that is powered through a fixed installation such
as a wall outlet wired to a distribution board and
measurement on such wiring.
Measurement category III (CAT III) CAT III applies to measurement at the distribution level,
that is, building wiring, fixed installations.
Measurement category IV (CAT IV) CAT IV applies to measurement at the primary supply
level, that is, overhead lines, cable systems.
6 Pollution degree refers to the degree of adhesion of a solid, liquid, or gas which deteriorates
withstand voltage or surface resistivity. Pollution Degree 2 applies to normal indoor atmospheres
(with only non-conductive pollution).
7 The product is a Class A (for industrial environments) product. Operation of the product in a
residential area may cause radio interference in which case the user will be required to correct
the interference.
8 For conformity to environmental regulations and/or standards other than EU, contact your local
Yokogawa office.
Input Voltage Derating by Frequency
WARNING
As the frequency of the input signal increases, the maximum input voltage of the probe
decreases.
Input Voltage Derating by Frequency
10000
1000
100
10
0.01 0.1 1 10 100
Frequency [MHz]
Maximum input voltage
[V]
150
1000
Regulations and Sales in Various Countries and Regions
Waste Electrical and Electronic Equipment (WEEE)
(EU WEEE Directive valid only in the EEA* and UK WEEE Regulations in the UK)
This product complies with the WEEE marking requirement. This marking indicates
that you must not discard this electrical/electronic product in domestic household
waste. When disposing of products in the EEA or UK, contact your local Yokogawa
office in the EEA or UK respectively.
*EEA: European Economic Area
Authorized Representative in the EEA (AR)
Yokogawa Europe B. V. is the authorized representative of Yokogawa Test & Measurement
Corporation for this product in the EEA. To contact Yokogawa Europe B. V., see the separate list of
worldwide contacts, PIM 113-01Z2.
Disposal
When disposing of YOKOGAWA products, follow the laws and ordinances of the country or region
where the product will be disposed of.
产品中有害物质的名称及含量
This section is valid only in China.
部件名称 有害物质
铅 (Pb)汞 (Hg)镉 (Cd)六价铬 (Cr(VI)) 多溴联苯 (PBB) 多溴二苯醚 (PBDE)
框架 ( 塑料) ×○ ○ ○ ○ ○
框架 ( 金属) ×○ ○ ○ ○ ○
线路板部件组装 ×○ ○ ○ ○ ○
电缆 ×○ ○ ○ ○ ○
配件 ×○ ○ ○ ○ ○
○:
表示该有害物质在该部件所有均质材料中的含量均在 GB/T 26572 规定的限量要求以下。
×:
表示该有害物质至少在该部件的某一均质材料中的含量超出 GB/T 26572 规定的限量要求。
环保使用期限
该标识适用于 SJ/T 11364 中所述,在中华人民共和国销售的电子电气产品的环
保使用期限。
只要您遵守该产品相关的安全及使用注意事项,在自制造日起算的年限内,则
不会因产品中有害物质泄漏或突发变异,而造成对环境的污染或对人体及财产
产生恶劣影响。
注)该年数为“环保使用期限”,并非产品的质量保证期。零件更换的推荐周期,
请参照使用说明书。
1.
Connect the appropriate accessories to the probe input leads. See also below for connecting
accessories.
2.
Supply power from the probe power terminal on the connected oscilloscope or the power supply
unit sold separately through the power cable. Warm up the probe for at least 30 minutes.
3.
Connect the BNC output connector to the oscilloscope input terminal.
4.
Select the appropriate attenuation ratio with the attenuation switch.
5.
If the residual offset voltage is large, short the tips of the input leads, and turn the offset voltage
adjustment screw using an appropriate screwdriver to adjust the offset voltage.
6.
Connect the two tips of input leads to the two points of the device under measurement (differential
measurement). Connect both tips since connecting only one tip will reduce performance.
Connecting Accessories
If using input leads and pincher tips, use the 100 Ω resistance adapters.
Input leads
Pincher tips
100 Ω resistance adapter (yellow)
If connecting extension leads to input leads, use the 150 Ω resistance adapters.
Input leads
Pincher tips
150 Ω resistance adapter (green)
Extension leads
Note
• Accurate measurements may not be possible near objects with strong electromagnetic fields
such as transformers, large current circuits, or wireless equipment.
• Before use, operate the attenuation switch several times. The electrical contacts of the switch
can weaken if not used for long periods of time.
• It is recommended to calibrate the probe once a year for accurate measurements.
4. Specifications
Item Specifications1
Frequency band2DC to 150 MHz (−3 dB) (with 100 Ω resistance adapters)
Using extension leads (with 150 Ω resistance adapters):
DC to 100 MHz (−3 dB) (typical3)
Attenuation ratio 50:1, 500:1 (switchable)
DC gain accuracy Common mode input within 400 V: ±2 %
Common mode input within 1000 V: ±3 %
Input capacitance 5 pF (to ground, typical3)
Input resistance 4.1 MΩ ±3 % (to ground)
Rise time 2.34 ns (typical3)
Delay time 50:1 14 ns (typical3)
500:1 13 ns (typical3)
Allowable differential voltage
(between +/− terminals)
50:1 ±150 V (DC + ACpeak)
500:1 ±1500 V (DC + ACpeak)
Maximum input voltage (to ground)4±1500 V (DC + ACpeak)
Allowable common mode voltage 1000 Vrms
Maximum non-destructive input
voltage
Differential mode: ±1600 V (DC + ACpeak)
Common mode: 1300 Vrms
Overload range 50:1 150 V or more
500:1 1500 V or more
CMRR (typical3)−80 dB (60 Hz), −50 dB (1 MHz)
Output voltage ±3.0 V (offset voltage adjustable)
Input conversion noise 50:1 50 mVrms or less
500:1 300 mVrms or less
Length Probe total 2430 mm ±30 mm
Input lead 200 mm ±10 mm
Power cable 1000 mm ±30 mm
Weight Approx. 300 g
Power supply voltage ±12.0 V ±0.6 V
Consumption current 60 mA (typical3)
Connector type BNC
Operating environment Temperature +5 °C to +40 °C (no condensation)
Humidity 25 % to 85 %RH
Altitude 2000 m or less
Storage environment Temperature −30 °C to +60 °C (no condensation)
Humidity 25 % to 85 %RH
Altitude 3000 m or less
Warm-up time 30 minutes or more
Compliant
standards
Safety standards5, 6 Probe only (excluding pincher tip)
EN 61010-031
Measurement category III 1000 Vrms, Pollution degree 2
Pincher tip only (B9852MM/B9852MN)
EN 61010-031
Measurement category III 1000 Vrms, Pollution degree 2
Extension lead (B8099LF/B8099LG)
EN 61010-031
Measurement category III 1000 Vrms, Pollution degree 2
Combination of probe and the accessories above
EN 61010-031
Measurement category III 1000 Vrms, Pollution degree 2
EMC standards Emission7EN 61326-1 Class A
EN 55011 Class A Group 1
Immunity EN 61326-1 Table 2
Environmental
standards8
EU RoHS Directive compliant
1 They depend on conditions of 23 ±5 °C, 55 ±10 %RH, and 30 minutes after power-on.
2 In combination with an oscilloscope
3“Typical” values are typical or average values and are not strictly guaranteed.
4 Input voltage derating by frequency applies. See the following figure for details.
IM 701978-01EN 2/2

Other YOKOGAWA Analytical Instrument manuals

YOKOGAWA OX100 User manual

YOKOGAWA

YOKOGAWA OX100 User manual

YOKOGAWA Vigilantplant NFBU200-S Series User manual

YOKOGAWA

YOKOGAWA Vigilantplant NFBU200-S Series User manual

YOKOGAWA 701922 User manual

YOKOGAWA

YOKOGAWA 701922 User manual

YOKOGAWA EXAxtZR User manual

YOKOGAWA

YOKOGAWA EXAxtZR User manual

YOKOGAWA MG8G User manual

YOKOGAWA

YOKOGAWA MG8G User manual

YOKOGAWA ZR22S User manual

YOKOGAWA

YOKOGAWA ZR22S User manual

YOKOGAWA 701941 User manual

YOKOGAWA

YOKOGAWA 701941 User manual

YOKOGAWA ZR202G User manual

YOKOGAWA

YOKOGAWA ZR202G User manual

YOKOGAWA SMARTDAC+ GX10 User manual

YOKOGAWA

YOKOGAWA SMARTDAC+ GX10 User manual

YOKOGAWA ZS8 User manual

YOKOGAWA

YOKOGAWA ZS8 User manual

YOKOGAWA EXAxt ZR22G Manual

YOKOGAWA

YOKOGAWA EXAxt ZR22G Manual

YOKOGAWA 701940 User manual

YOKOGAWA

YOKOGAWA 701940 User manual

YOKOGAWA 701940 User manual

YOKOGAWA

YOKOGAWA 701940 User manual

YOKOGAWA ZR Series Specification sheet

YOKOGAWA

YOKOGAWA ZR Series Specification sheet

YOKOGAWA 701977 User manual

YOKOGAWA

YOKOGAWA 701977 User manual

Popular Analytical Instrument manuals by other brands

Johnson 40-6004 instruction manual

Johnson

Johnson 40-6004 instruction manual

Swann AMU-II Installation instruction

Swann

Swann AMU-II Installation instruction

RinnoVision RV-PRO 360 User guideline

RinnoVision

RinnoVision RV-PRO 360 User guideline

Parkside PLEM 50 A1 Operation and safety notes

Parkside

Parkside PLEM 50 A1 Operation and safety notes

VEVOR 451P user manual

VEVOR

VEVOR 451P user manual

In-situ SMARTROLL MP Operator's manual

In-situ

In-situ SMARTROLL MP Operator's manual

Unit UT390B operating manual

Unit

Unit UT390B operating manual

Technoline WZ 1100 manual

Technoline

Technoline WZ 1100 manual

Prexiso P60LC Instrument Set-up

Prexiso

Prexiso P60LC Instrument Set-up

PCE Instruments PCE-LRF 500 user manual

PCE Instruments

PCE Instruments PCE-LRF 500 user manual

LaserLiner VideoScope XXL manual

LaserLiner

LaserLiner VideoScope XXL manual

Ryobi LDM-60 Owner's operating manual

Ryobi

Ryobi LDM-60 Owner's operating manual

IFM O1D103 operating instructions

IFM

IFM O1D103 operating instructions

Wetecom 85 94 39 instruction manual

Wetecom

Wetecom 85 94 39 instruction manual

Instek Digital GOS-6103C user manual

Instek Digital

Instek Digital GOS-6103C user manual

Dräger Pac 7000 Instructions for use

Dräger

Dräger Pac 7000 Instructions for use

cytiva Amersham ImageQuant 800 user manual

cytiva

cytiva Amersham ImageQuant 800 user manual

Bosch FSA 720 instruction manual

Bosch

Bosch FSA 720 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.