manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. 3One data
  6. •
  7. Switch
  8. •
  9. 3One data ICS5400 Series User manual

3One data ICS5400 Series User manual

ICS5400 Series
Rack-mounted Layer 3 Industrial
Ethernet Switch
Quick Installation Guide
3onedata Co., Ltd.
Address: 3/B, Zone 1, Baiwangxin High Technology
Industrial Park, Xili, Nanshan District, Shenzhen
Website: www.3onedata.com
Tel : +86 0755-26702688
Fax: +86 0755-26703485
【Package Checklist】
Please check the integrity of package and accessories while
first using the switch.
1.
Switch ×1
2.
Mounting lug x2
3.
AC power line x2 (AC product only)
4.
Warranty card
5.
Certificate
If any of these items are damaged or lost, please contact our
company or dealers, we will solve it ASAP.
【Product Overview】
This series are rack-mounted layer 3 industrial Ethernet
switches. For convenience, the products of this series adopt
the following number on the left in this guide, please confirm
the number of your product:
Model I. ICS5400-24GT4XS-2LV (24 Gigabit copper ports + 4
10G SFP+ slots, 12~55VDC redundant power
supply).
Model II. ICS5400-12GT16GS4XS-2LV (12 Gigabit copper
ports + 16 Gigabit SFP slots + 4 10G SFP+ slots,
12~55VDC redundant power supply)
Model III. ICS5400-24GT8GS4XS-2LV (24 Gigabit copper
ports + 8 Gigabit SFP slots + 4 10G SFP+ slots,
12~55VDC redundant power supply)
Model IV. ICS5400-24GT16GS4XS-2LV (24 Gigabit copper
ports + 16 Gigabit SFP slots + 4 10G SFP+ slots,
12~55VDC redundant power supply)
Model V. ICS5400-24GT4XS-2HV (24 Gigabit copper ports +
4 10G SFP+ slots, 85~264VAC redundant power
supply).
Model VI. ICS5400-12GT16GS4XS-2HV (12 Gigabit copper
ports + 16 Gigabit SFP slots + 4 10G SFP+ slots,
85~264VAC redundant power supply)
Model VII. ICS5400-24GT8GS4XS-2HV (24 Gigabit copper
ports + 8 Gigabit SFP slots + 4 10G SFP+ slots,
85~264VAC redundant power supply)
Model VIII.ICS5400-24GT16GS4XS-2HV (24 Gigabit copper
ports + 16 Gigabit SFP slots + 4 10G SFP+ slots,
85~264VAC redundant power supply)
【Panel Design】
DC device: front view
Model I
Model II
Model III
Model IV
DC device: rear view
AC device: front view
Model V
Model VI
Model VII
Model VIII
AC device: rear view
1. Lugs
2. Grounding screw (M4)
3. Relay alarm output interface
4. 100/1000Base-X Gigabit SFP slot (GS 1-16/1-8)
5. 10/100/1000Base-T(X) Gigabit copper port (GE
1-24 / 17-28 / 17-32 / 9-32 / 17-40)
6. 1G/2.5G/10GBase-X 10Gigabit SFP+ slot (XS 1-4)
7. CONSOLE port
8. Device indicators, from left to right in turn they are:
- Ethernet port indicator (G1-G24/28/32/40,
X1-X4)
- Power indicator (P2-P1)
- Alarm indicator (ALM)
- Running indicator (RUN)
9. DC power supply input terminal blocks
10. AC power 2 supply input socket (PWR2)
11. AC power 1 input socket (PWR1)
【Mounting Dimension】
The external dimensions of this series of products are the
same, unit: mm.
DC device
AC device
Notice Before Mounting:
Don't place or install the device in area near water or
moist, keep the relative humidity of the device
surrounding between 5%~95% without condensation.
Before power on, first confirm the supported power
supply specification to avoid over-voltage damaging the
device.
The device surface temperature is high after running;
please don't directly contact to avoid scalding.
【Rack-mounted】
This product adopts 1U rack-mounting, mounting steps as
below:
Select the device mounting location to ensureStep 1
enough size.
Adopt 4 bolts to install the mounting lugs in theStep 2
device position as figure below.
Place the device in the rack; adopt 4 bolts to fix twoStep 3
sides mounting lugs in the rack.
Check and confirm the product is mounted firmly onStep 4
the rack, mounting ends.
【Disassembling Device】
Power off the device.Step 1
Adopt screw driver to loosen the 4 bolts fixed onStep 2
the mounting lugs in the rack.
Shift out the device from rack, disassembling ends.Step 3
Notice before power on:
Power ON operation: First insert the power supply
terminal block into the device power supply interface,
then plug the power supply plug contact and power on.
Power switch “—” means power ON, “O” means power
OFF.
Power OFF operation: First, put the powers switch to
the "O" side and then disconnect the power supply.
Finally disconnect the connector between the device and
the power cord. Please notice the operation order above.
Please be aware of the power input range supported by
the device before powering on. Use the recommended
voltage of the device to avoid device damage.
【Power Supply Connection】
DC device power supply
Model I- Model IV provide 5-pin
5.08mm pitch terminal blocks and the
built-in dual power supply redundancy
supports DC power input. The power
input supports 1 single power supply
input or 2 power supply inputs at the same time; When two
power supply input at the same time, it supports redundant
backup of power supply. If one power supply fails, the device
can still work normally without interruption. Power supply
supports anti-reverse connection, which cannot power the
device but won’t damage it when it's reversely connected. The
definitions of power pin are shown in the left figure, and the
power input range is 24VDC/48VDC (12~55VDC).
AC device power supply
Model V-Model VIII provides 2 AC
power sockets with switch, PWR1 and
PWR2, and supports AC power supply
input. The power input supports 1 single
power supply input or 2 power supply
inputs at the same time; When two power supply input at the
same time, it supports redundant backup of power supply. If
one power supply fails, the device can still work normally
without interruption. Power supply input range:
110VAC/220VAC (85~264VAC).
【Relay Connection】
Provide 3-pin 5.08mm pitch terminal block,
support 1 relay alarm output. In power off
situation, R- and R+ are a group of normally
closed contacts. After powered on, the relay is
open circuit in normal non-alarm state by default, closed when
any alarm information occurs. The relay supports power
supply alarm or network abnormality alarm. It can be
connected to alarm light or alarm buzzer or other switching
value collecting devices, which can timely inform operators
when the alarm occurs.
【Console Port Connection】
Provide 1 program debugging port based on
RS-232 serial port which can conduct device CLI
command management after connecting to PC.
The interface adopts RJ45 port, the RJ45 pin definitions are
as follows:
Pin No.
2
3
5
Definition
TXD
RXD
GND
【Checking LED Indicator】
Provide LED indicators to monitor its operating status, which
has simplified the overall troubleshooting process. The
function of each LED is described in the table below:
LED
Indicate
Description
P1/P2
ON
Power P1/2 is running normally
OFF Power P1/2 is disconnected or
running abnormally
LED
Indicate
Description
ALM
ON Power supply or port link has
alarm
OFF Power supply, port link without
alarm
RUN
ON
The device is running
abnormally
Blinking
Blinking 1 time per second,
system is running normally
OFF
The device is powered off or
the device is abnormal.
LINK
(G1-24/28/32/40
, X1-X4)
ON Ethernet port has established a
valid network connection
Blinking
Ethernet port is in an active
network status
OFF
Ethernet port has not
established valid network
connection
【Logging in to WEB Interface】
Support WEB management and configuration. Computer can
access the device via Ethernet interface. The way of logging
in to device’s configuration interface via browser is shown as
below:
Configure the IP addresses of computer and theStep 1
device to the same network segment, and the
network between them can be mutually accessed.
Enter device’s IP address in the address bar of theStep 2
computer browser.
Enter device’s username in the login window asStep 3
shown below.
Click “Login” button to login to the WEB interface ofStep 4
the device.
Note:
The default IP address of the device is “192.168.1.254”.
The default username and password of the device are
“admin123”.
If the username or password is lost, user can restore it to
factory settings via management software; all modified
configurations will be cleared after restoring to factory
settings, so please backup configuration file in advance.
Please refer to user manual for specific configuration
method of logging in to WEB interface and other
configurations about network management function.
【Specification】
Panel
Gigabit copper port 10/100/1000Base-T(X)
self-
adaption or forced mode,
RJ45, Automatic Flow Control,
Full/Half Duplex Mode,
MDI/MDI-X Autotunning
Gigabit SFP 100/1000Base-X self-adaption
or forced mode, SFP slot
10Gigabit SFP+ 1G/2.5G//10GBase-X
self-
adaption or forced mode,
SFP+ slot
Relay 1 relay alarm information output,
using 3-
pin 5.08mm pitch
terminal blocks, and the current
load capacity is 1A@30VDC or
0.3A@125VAC
CONSOLE port CLI command line management
port (RS-232), RJ45
Indicator Power indicator, alarm indicator,
running indicator, interface
indicator
Switch Property
Backplane bandwidth
160G
Packet buffer size
32Mbit
MAC Address Table
32K
Power Supply
Model I-Model IV
24VDC/48VDC (12~55VDC),
dual power supply redundancy,
using 5-
pin 5.08mm pitch
terminal blocks, support
anti-reverse connection
Model V-Model VI 110VAC/220VAC (85~264VAC),
dual power supply redundancy,
using AC socket with switch
Power Consumption
Full-load
<
47.3W
Working Environment
Working temperature
-40~75℃
Storage temperature
-40~85℃
Working humidity
5%
~
95% (no condensation)
Protection grade
IP40 (metal shell)
【Disposal of Waste Electrical and Electronic
Equipment (WEEE 2012/19/EU)】
(Applicable in the EU-member states)
The crossed-out wheeled bin symbol on the equipment or its
packaging indicates that the product, at the end of its service
life, shall not be mixed with unsorted municipal waste but
should be collected separately, in accordance with local laws
and regulations.
A proper separate collection of end-of-life equipment for the
subsequent recycling, treatment and environmentally
compatible disposal, will help prevent potential damage to the
environment and human health, facilitating the reuse,
recycling and/or recovery of its component materials.
Private users should contact their vendor or municipal waste
management service and ask for disposal information.
Professional users should contact their suppliers and check
the terms of their selling agreement.
This product must not be disposed of with other commercial
waste.
Users’ cooperation in the correct disposal of this product will
contribute to saving valuable resources and protecting the
environment.

Other 3One data Switch manuals

3One data TNS5800D User manual

3One data

3One data TNS5800D User manual

3One data PS5010G-2GS-8PoE User manual

3One data

3One data PS5010G-2GS-8PoE User manual

3One data ICS6420 Series User manual

3One data

3One data ICS6420 Series User manual

3One data IES2008 User manual

3One data

3One data IES2008 User manual

3One data IPS7110-2GC-8POE User manual

3One data

3One data IPS7110-2GC-8POE User manual

3One data TNS5000D Series User manual

3One data

3One data TNS5000D Series User manual

3One data IES7110 3GS Series User manual

3One data

3One data IES7110 3GS Series User manual

3One data IPS215 Series User manual

3One data

3One data IPS215 Series User manual

3One data TNS5800 Series User manual

3One data

3One data TNS5800 Series User manual

3One data IES6100 Series User manual

3One data

3One data IES6100 Series User manual

3One data IES1028 Series User manual

3One data

3One data IES1028 Series User manual

3One data TNS5800D Series User manual

3One data

3One data TNS5800D Series User manual

3One data IPS7110 Series User manual

3One data

3One data IPS7110 Series User manual

3One data ES2010G-2GS User manual

3One data

3One data ES2010G-2GS User manual

3One data IES2312-8GT2GS2HS-2P48 User manual

3One data

3One data IES2312-8GT2GS2HS-2P48 User manual

3One data IES615-2DI Series User manual

3One data

3One data IES615-2DI Series User manual

3One data IPS3110 Series User manual

3One data

3One data IPS3110 Series User manual

3One data IES5028-4GS-2F User manual

3One data

3One data IES5028-4GS-2F User manual

3One data IES2100SL Series User manual

3One data

3One data IES2100SL Series User manual

3One data ICS5428 Series User manual

3One data

3One data ICS5428 Series User manual

3One data IPS716-2GC-4POE User manual

3One data

3One data IPS716-2GC-4POE User manual

3One data IPS7112G-4GS-8POE User manual

3One data

3One data IPS7112G-4GS-8POE User manual

3One data IES3000 Series User manual

3One data

3One data IES3000 Series User manual

3One data IES7110-2GS Series User manual

3One data

3One data IES7110-2GS Series User manual

Popular Switch manuals by other brands

ATEN Master View CS-82A user manual

ATEN

ATEN Master View CS-82A user manual

Brocade Communications Systems 300 Hardware installation guide

Brocade Communications Systems

Brocade Communications Systems 300 Hardware installation guide

Bticino L4003CW quick start guide

Bticino

Bticino L4003CW quick start guide

ITT NEO-DYN 100P ENCLOSURE 7 Installation and operation manual

ITT

ITT NEO-DYN 100P ENCLOSURE 7 Installation and operation manual

Smart Digital SMART MIX SDM300 user manual

Smart Digital

Smart Digital SMART MIX SDM300 user manual

NETGEAR Nighthawk GS808E installation guide

NETGEAR

NETGEAR Nighthawk GS808E installation guide

Luceat 320.SIS.VDIP202S004P user manual

Luceat

Luceat 320.SIS.VDIP202S004P user manual

H3C S3610 Series Operation manual

H3C

H3C S3610 Series Operation manual

TRENDnet TEG-S40SX user guide

TRENDnet

TRENDnet TEG-S40SX user guide

Linksys SLM248P - Cisco - 10/100 Product data

Linksys

Linksys SLM248P - Cisco - 10/100 Product data

Enterasys Matrix-V V2H124-24 Hardware installation guide

Enterasys

Enterasys Matrix-V V2H124-24 Hardware installation guide

Juniper EX2200 Series Hardware guide

Juniper

Juniper EX2200 Series Hardware guide

Icy Box IB-HUB1426-U3 Quick installation guide

Icy Box

Icy Box IB-HUB1426-U3 Quick installation guide

HPE FlexFabric 5940 SERIES Configuration guide

HPE

HPE FlexFabric 5940 SERIES Configuration guide

Eaton P3-63/I4 Instruction leaflet

Eaton

Eaton P3-63/I4 Instruction leaflet

Planet Networking & Communication IGS-10020HPT user manual

Planet Networking & Communication

Planet Networking & Communication IGS-10020HPT user manual

Intellinet 502931 instructions

Intellinet

Intellinet 502931 instructions

ATEN KH1508Ai user manual

ATEN

ATEN KH1508Ai user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.