manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. 3One data
  6. •
  7. Switch
  8. •
  9. 3One data ICS5428 Series User manual

3One data ICS5428 Series User manual

Other 3One data Switch manuals

3One data IES716-2GS User manual

3One data

3One data IES716-2GS User manual

3One data IES7116G-8GS Series User manual

3One data

3One data IES7116G-8GS Series User manual

3One data IES3012G Series User manual

3One data

3One data IES3012G Series User manual

3One data IPS7112G-4GS-8GPOE User manual

3One data

3One data IPS7112G-4GS-8GPOE User manual

3One data IES215-1GX-4G User manual

3One data

3One data IES215-1GX-4G User manual

3One data IPS7112G-4GS-8GPOE User manual

3One data

3One data IPS7112G-4GS-8GPOE User manual

3One data IPS215 Series User manual

3One data

3One data IPS215 Series User manual

3One data IPS7110-2GC-4POE Series User manual

3One data

3One data IPS7110-2GC-4POE Series User manual

3One data IES618 Series User manual

3One data

3One data IES618 Series User manual

3One data IES1024 Series User manual

3One data

3One data IES1024 Series User manual

3One data MES600 Series User manual

3One data

3One data MES600 Series User manual

3One data IES3016 Series User manual

3One data

3One data IES3016 Series User manual

3One data IES5028-4GS-2F User manual

3One data

3One data IES5028-4GS-2F User manual

3One data IES2210 Series User manual

3One data

3One data IES2210 Series User manual

3One data TNS5800-8GP16GT-P24VDC User manual

3One data

3One data TNS5800-8GP16GT-P24VDC User manual

3One data IES7110-2GS Series User manual

3One data

3One data IES7110-2GS Series User manual

3One data PS5026G-2GS-24PoE User manual

3One data

3One data PS5026G-2GS-24PoE User manual

3One data IES6306 Series User manual

3One data

3One data IES6306 Series User manual

3One data IPS716-2GC-4POE User manual

3One data

3One data IPS716-2GC-4POE User manual

3One data ES2010G-2GS User manual

3One data

3One data ES2010G-2GS User manual

3One data SW4485I User manual

3One data

3One data SW4485I User manual

3One data IES6320 Series User manual

3One data

3One data IES6320 Series User manual

3One data PS1005G-1GT-4POE Operating and maintenance instructions

3One data

3One data PS1005G-1GT-4POE Operating and maintenance instructions

3One data IES6100PN-8T-2LV User manual

3One data

3One data IES6100PN-8T-2LV User manual

Popular Switch manuals by other brands

SMC Networks SMC6224M Technical specifications

SMC Networks

SMC Networks SMC6224M Technical specifications

Aeotec ZWA003-S operating manual

Aeotec

Aeotec ZWA003-S operating manual

TRENDnet TK-209i Quick installation guide

TRENDnet

TRENDnet TK-209i Quick installation guide

Planet FGSW-2022VHP user manual

Planet

Planet FGSW-2022VHP user manual

Avocent AutoView 2000  AV2000BC AV2000BC Installer/user guide

Avocent

Avocent AutoView 2000 AV2000BC AV2000BC Installer/user guide

Moxa Technologies PT-7728 Series user manual

Moxa Technologies

Moxa Technologies PT-7728 Series user manual

Intos Electronic inLine 35392I operating instructions

Intos Electronic

Intos Electronic inLine 35392I operating instructions

Cisco Catalyst 3560-X-24T Technical specifications

Cisco

Cisco Catalyst 3560-X-24T Technical specifications

Asante IntraCore IC3648 Specifications

Asante

Asante IntraCore IC3648 Specifications

Siemens SIRIUS 3SE7310-1AE Series Original operating instructions

Siemens

Siemens SIRIUS 3SE7310-1AE Series Original operating instructions

Edge-Core DCS520 quick start guide

Edge-Core

Edge-Core DCS520 quick start guide

RGBLE S00203 user manual

RGBLE

RGBLE S00203 user manual

Thrustmaster FLIGHT SIMULATOR X quick guide

Thrustmaster

Thrustmaster FLIGHT SIMULATOR X quick guide

Southwire SURGE GUARD 41390 RVC troubleshooting guide

Southwire

Southwire SURGE GUARD 41390 RVC troubleshooting guide

Buhler Nivotemp NT 61 Brief instructions

Buhler

Buhler Nivotemp NT 61 Brief instructions

Kramer VS-41HDCP user manual

Kramer

Kramer VS-41HDCP user manual

Techly IDATA AU-270 user manual

Techly

Techly IDATA AU-270 user manual

Belkin F1U109 user manual

Belkin

Belkin F1U109 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

IES2105 Series
Unmanaged Industrial Ethernet
Switch
Quick Installation Guide
3onedata Co., Ltd.
【Package Checklist】
Please check whether the package and accessories are intact
while using the switch for the first time.
1. S
witch (with terminal
block)
2. Quick installation guide
3. DIN-
Rail mounting
attachment
4. Warranty card
5.
Certification
If any of these items are damaged or lost, please contact our
company or dealers, we will solve it ASAP.
【Product Overview】
This series are 100M unmanaged industrial Ethernet switches.
For convenience, the products of this series adopt the
following number on the left in this guide, please affirm the
number of your product.
Model I. IES2105-5T-P48 (5 100M copper ports + 1 48VDC
power supply)
Model II. IES2105-5T-P220 (5 100M copper ports + 1
220VAC power supply)
Model III. IES2105-4P1T-P48 (4 100M PoE copper ports + 1
100M copper port + 1 48VDC power supply)
Model IV. IES2105-4P1F-P48 (4 100M PoE copper ports + 1
100M fiber port + 1 48VDC power supply)
Model V. IES2105-4T1F-P48 (4 100M copper ports + 1
100M fiber port + 1 48VDC power supply)
Model VI. IES2105-4T1F-P220 (4 100M copper ports + 1
100M fiber port + 1 220VAC power supply)
Model VII. IES2105-3T2F-P48 (3 100M copper ports + 2
100M fiber ports + 1 48VDC power supply)
Model VIII. IES2105-3T2F-P220 (3 100M copper ports + 2
100M fiber ports + 1 220VAC power supply)
【Panel Design】
Side view
Model I, II Model III Model IV
Model V, VI Model VII, VIII
Rear view, Bottom view and Top view
1. Power supply indicator
2. 100M copper port
3. Interface connection indicator
4. PoE indicator
5. 100M PoE copper port
6. 100M Fiber Port
7. DIN-Rail mounting kit
8. Terminal block for power input
9. DIP switch
10. Grounding screw
【Mounting Dimension】
Unit: mm
Address:
3/B, Zone 1, Baiwangxin High Technology
Industrial Park, Xili, Nanshan District,
Shenzhen
Website:
www.3onedata.com
Tel:
+86 0755-26702688
Fax:
+86 0755-26703485
【DIN-Rail Mounting】
The product adopts 35mm standard DIN-Rail mounting which
is suitable for most industrial scenes, mounting steps as
follows:
Step 1 Check if the DIN-Rail mounting kit is installed firmly.
Step 2 Insert the bottom of DIN-Rail mounting kit (one side
with spring support) into DIN-Rail, and then insert
the top into DIN-Rail.
Tips:
Insert a little to the bottom, lift upward and then insert
to the top.
Step 3 Check and confirm the product is firmly installed on
DIN-Rail, then mounting ends.
【Disassembling DIN-Rail】
Step 1 Power off device.
Step 2 After lifting the device upward slightly, first shift out
the top of DIN-Rail mounting kit, and then shift out
the bottom of DIN-Rail, disassembling ends.
Notes:
Don't place or install the device in area near water or
moist, keep the relative humidity of the device
surrounding between 5%~95% without condensation.
Before power on, first confirm the supported power
supply specification to avoid over-voltage damaging the
device.
The device surface temperature is high after running;
please don't directly contact to avoid scalding.
【Power Supply Connection】
12~48VDC power supply
Model I, V, VII devices of this series support
DC power input, and provide 3-pin terminals
with a spacing of 7.62 mm. The power supply
has non-polarity function. Voltage range:
12~48VDC. The pin definitions of power supply are shown as
follows:
PIN
1
2
3
Definition
V+
FG
V-
48VDC power supply
Model III, IV devices of this series support DC
power input, and provide 3-pin terminals with
a spacing of 7.62 mm. The power supply has
anti-reverse connection function. Support
48V PoE, power range: 48VDC (44~55VDC). The pin
definitions of power supply are shown as follows:
PIN
1
2
3
Definition
V+
FG
V-
AC power supply
Model II, VI, VIII devices of this series
support AC power input, and provide 3-pin
terminals with a spacing of 7.62 mm. Power
supply range: 220VAC (100~240VAC). The
pin definitions of power supply are shown as follows:
PIN
1
2
3
Definition
L
FG
N
Notice:
Power ON operation: First insert the power supply
terminal block into the device power supply interface,
and then plug the power supply plug contact and power
on.
Power OFF operation: First, remove the power plug,
and then remove the wiring section of terminal block.
Please pay attention to the above operation sequence.
【DIP Switch Settings】
This series provide 4-pin DIP switch for function
setting, where "ON" is the enabled end. DIP
switches definition as follows:
DIP
Definition
Operation
1 Jumbo frame Set the DIP to ON to enable jumbo
frame function
2 Flow Control Set the DIP to ON to enable flow
control function
3
One-key
VLAN
Set the DIP to ON to enable VLAN
function. Copper port 1 is
interconnected with other
interfaces, and other ports except
copper port 1 are isolated from
each other.
4
Reserved
-
[Checking LED Indicator]
The device provides LED indicators to monitor the device
working status with a comprehensive simplified
troubleshooting; the detailed status of each LED is described
in the table as below:
LED
Indicate
Description
PWR
ON PWR is connected and running
normally
OFF PWR is disconnected and running
abnormally
PoE(1-4) ON POE port is powering other devices
normally
OFF
POE is disabled or disconnected
Link/ACT
(1-5)
ON Port has established valid network
connection
Blinking
Port is receiving/ transmitting data
OFF
Port hasn't established valid
network connection
【Specification】
Panel
100M Fiber Port 100Base-
FX, optional
SC/ST/FC
100M copper port 10/100Base-T(X) self-adapting
RJ45 port, half/full duplex
self-adaption or forced working
mode, support MDI/ MDI-X
self-adaption
100M POE copper port 10/100Base-
T(X) RJ45,
automatic flow control, full/half
duplex mode, MDI/ MDI-X
autotunning, POE port, output
power of 15W or 30W.
POE pin V+, V+, V-, V- are
corresponding to 1, 2, 3, 6.
Indicator Power indicator, PoE indicator,
interface indicator
Power supply
Input power supply 12~48VDC power supply,
support non-polarity
48VDC power supply:
44~55VDC, support
anti-reverse connection
220VAC power supply:
100~240VAC
Access terminal block 3-
pin 7.62mm pitch terminal
blocks
Switch Property
Backplane bandwidth
1G
MAC address
2K
Power consumption
Model I No-load: ≤0.96W@48VDC
Full-load: ≤1.4W@48VDC
Model IV
No-load: ≤2W@48VDC
Full-load:≤110W@48VDC (with
PoE full load)
Working Environment
Working temperature
-40
~
75℃
Storage temperature
-40
~
85
℃
Working humidity
5%
~
95% (no condensation)
Protection grade
IP40 (metal shell)