jobAid
DESCRIPTION
The Small Form-Factor Pluggable 10 Gigabit Ethernet XFP, 1550
nm, Temperature Hardened (XFP) optical transceiver is a fully
duplex serial electric, serial optic device. It contains both transmit
and receive functions, providing a high speed serial link at 10
Gb/s. Installed into an appropriate host module, the XFP
provides a 10 Gigabit interface to the supporting system.
The transmit side of the XFP converts serial NRZ electrical date at
the 10 Gb/s line rate to a standard compliant optical signal. The
receive side of the XFP converts the incoming DC balanced serial
NRZ optical data at the 10 Gb/s line rate into serial electrical data.
NOTE
To ensure compatibility, refer to the documentation provided
with the host module.
FEATURES
The following features are supported on the XFP:
■1550 nm optical signals for up to 40 km reach
■Low power consumption (<3.5 W max)
■Excellent EMI performance
CAUTION
!
Due to compliance certification requirements, use only XFPs
supplied by ADTRAN with the host module. ADTRAN cannot
certify system integrity with other XFPs.
Small Form-Factor Pluggable
10 Gigabit Ethernet XFP, 1550 nm,
Temperature Hardened
INSTALLATION
Before installation, inspect the XFP. If damage has occurred
during shipping, file a claim with the carrier, and then contact
ADTRAN Customer Support. For more information, refer to
“Warranty”.
Installation Guidelines
The following are guidelines for this installation.
■The latch on the XFP is for removal only. When removing the
XFP, rotate the latch away from the XFP. The XFP should slide
easily out of the cage.
■We recommend that you keep the connector plug on
whenever the transceiver optical fiber connector is not
inserted.
Installation Steps
To install the XFP, complete the following steps:
1. Insert the XFP into the XFP cage on the circuit board of the
host module with the latch handle facing outward. Slide the
XFP all the way into the cage.
2. Exert adequate pressure to ensure the XFP is completely
seated in the XFP cage.
3. Do not remove the connector plug until the optical fiber
connection is made.
4. Continue the installation and turn-up of the host module.
SPECIFICATIONS
■Optical Specifications:
♦Transmit Wavelength: 1530 nm to 1565 nm
♦Receive Wavelength: 1270 nm to 1600 nm
♦Data rate: 9.95 Gb/s to 10.30 Gb/s
♦Optical transmit level: –1.0 dBm to +2.0 dBm
♦Optical receive level: –16.0 dBm to –1.0 dBm
♦Optical distance: 40 km maximum
♦Optical connectors: LC
■Extended Environmental Support:
♦Operational temperature range: –40°C to +65°C
●Case temperature hardened range: –40°C to +85°C
♦Storage temperature range: –40°C to +85°C
♦Relative humidity to 85%, noncondensing
CLEI: BVL3ADMD_ _
Product P/N: 1442940G1
Issue Date: October 2014
Document P/N: 61442940G1-22C
Documentation for ADTRAN Carrier Networks products is available for
viewing and download directly from the ADTRAN Support Community
website.
Go to: https://supportforums.adtran.com/welcome
Registration is required.
ADTRAN offers training courses on our products, including customized
training and courses taught at our facilities or at customer sites.
For inquiries, go to: http://adtran.com/training
The following related online documents and resources provide additional information for this
product:
SFP/XFP/SFP+ Compatibility Matrix (online tool, go to: http://www.adtran.com/sfp)
CAUTION!
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY
HANDLING PRECAUTIONS REQUIRED
Warranty: ADTRAN will replace or repair this product within the warranty period if it does not
meet its published specifications or fails while in service. Warranty information can
be found online at www.adtran.com/warranty.
Trademarks: Brand names and product names included in this document are trademarks,
registered trademarks, or trade names of their respective holders.
©2015 ADTRAN, Inc. All Rights Reserved.
ADTRAN CUSTOMER CARE:
From within the U.S. 1.800.726.8663
From outside the U.S. +1 256.963.8716
PRICING AND AVAILABILITY 1.800.827.0807
*61442940G1-22C*
SAFETY AND REGULATORY COMPLIANCE
WARNING
!
Read all warnings and cautions before installing or servicing this
equipment.
CAUTION
C
The product is a Class 1 Laser Product and complies with the
Laser Safety requirements of FDA 21CFR 1040.10 and 1040.11,
and EN60825-1 and -2. The XFP is NRTL listed and CB Certified
to all applicable American and European safety standards.
For continued compliance with the above laser safety standards,
only approved Class 1 modules from our approved vendor list,
located on the ADTRAN website, should be installed in ADTRAN
products.
CAUTION
!
■Electrostatic Discharge (ESD) can damage electronic modules.
When handling modules, wear an antistatic discharge wrist
strap to prevent damage to electronic components. Place
modules in antistatic packing material when transporting or
storing. When working on modules, always place them on an
approved antistatic mat that is electrically grounded.
■This product meets or exceeds all the applicable requirements
of NEBS, Telcordia GR-63-CORE, and GR-1089-CORE. This
product is intended for deployment in Central Office type
facilities, EEEs, EECs, and locations where the NEC applies
(for example, Customer Premises). This product is to be
installed in ADTRAN products in Restricted Access Locations
only, and installed by trained service personnel.
■Per GR-1089-CORE the ADTRAN system that this product is
being deployed in is designed and intended for installation as
part of a Common Bonding Network (CBN). The ADTRAN
system that this product is being deployed in is not designed
nor intended for installation as part of an Isolated Bonding
Network (IBN).
■Per GR-1089-CORE Section 9, this product does not have an
internal DC connection between battery return and frame
ground. This product can be installed in a DC-I (isolated) or
DC-C (common) installation. For installations where other
cards or the host system have internal connections between
battery return and frame ground, the system would be
intended for deployment only in a DC-C installation.
■The ADTRAN system chassis frame ground terminal must be
connected to a reliable earth ground to ensure that the metal
enclosure of this product is properly grounded via the
backplane connector.
NOTE
■The Gigabit Ethernet port(s) are optical and therefore are not
classified as any type of port as defined in Appendix B of GR-
1089-CORE.
■This product is designed to be deployed in GR-3108-CORE
environmental Class 1, 2, & 3.
This device complies with Part 15 of the FCC rules. Operation is
subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including
interference that may cause undesired operation.
Changes or modifications not expressly approved by ADTRAN
could void the user's authority to operate this equipment.
This product is designed to meet the following environmental
classes:
■ETSI EN 300 019-1-1 Classification of environmental conditions;
Storage, Class 1.2
■ETSI EN 300 019-1-2 Classification of environmental conditions;
Transportation, Class 2.3
■ETSI EN 300 019-1-3 Classification of environmental conditions;
Stationary use at weather-protected locations, Class 3.3
The equipment is designed to function without degradation
during exposure to all test severities per Class 3.3.
This product meets EU RoHS Directive 2002/95/EC and/or
applicable exemptions. Refer to www.adtran.com for further
information on RoHS/WEEE.

Other ADTRAN Control Unit manuals

ADTRAN E1 User manual

ADTRAN

ADTRAN E1 User manual

ADTRAN SFP GPON ONU User manual

ADTRAN

ADTRAN SFP GPON ONU User manual

ADTRAN MX2820 SCU User manual

ADTRAN

ADTRAN MX2820 SCU User manual

ADTRAN OC-48/STM-16 DWDM SFP User manual

ADTRAN

ADTRAN OC-48/STM-16 DWDM SFP User manual

ADTRAN FXS+ Quad User manual

ADTRAN

ADTRAN FXS+ Quad User manual

ADTRAN Total Access 300 Series Product manual

ADTRAN

ADTRAN Total Access 300 Series Product manual

ADTRAN Job Aid+ Total Access 5000 1442910G1C User manual

ADTRAN

ADTRAN Job Aid+ Total Access 5000 1442910G1C User manual

ADTRAN Modem-16 Module User manual

ADTRAN

ADTRAN Modem-16 Module User manual

ADTRAN U-BR1TE Instruction Manual

ADTRAN

ADTRAN U-BR1TE Instruction Manual

ADTRAN E220 HFAC HDSL Product manual

ADTRAN

ADTRAN E220 HFAC HDSL Product manual

ADTRAN Async-232 User manual

ADTRAN

ADTRAN Async-232 User manual

ADTRAN Job Aid+ 1442707G1 User manual

ADTRAN

ADTRAN Job Aid+ 1442707G1 User manual

ADTRAN Total Access 300 Series User manual

ADTRAN

ADTRAN Total Access 300 Series User manual

ADTRAN Total Access 1500 Instruction Manual

ADTRAN

ADTRAN Total Access 1500 Instruction Manual

ADTRAN NetVanta SHDSL User manual

ADTRAN

ADTRAN NetVanta SHDSL User manual

ADTRAN Job Aid+ 1442804G1 User manual

ADTRAN

ADTRAN Job Aid+ 1442804G1 User manual

ADTRAN Quad T1 User manual

ADTRAN

ADTRAN Quad T1 User manual

ADTRAN Job Aid+ 1442910G1 User manual

ADTRAN

ADTRAN Job Aid+ 1442910G1 User manual

ADTRAN SFP User manual

ADTRAN

ADTRAN SFP User manual

ADTRAN Type 400 User manual

ADTRAN

ADTRAN Type 400 User manual

ADTRAN Job Aid+ 1442910G2 User manual

ADTRAN

ADTRAN Job Aid+ 1442910G2 User manual

ADTRAN Total Access 1500 FT1 DP Instruction Manual

ADTRAN

ADTRAN Total Access 1500 FT1 DP Instruction Manual

ADTRAN E220 HFAC HDSL Instruction Manual

ADTRAN

ADTRAN E220 HFAC HDSL Instruction Manual

ADTRAN Job Aid+ 1442704PG2 User manual

ADTRAN

ADTRAN Job Aid+ 1442704PG2 User manual

Popular Control Unit manuals by other brands

Watts AMES 960GD-17 Installation, operation and maintenance

Watts

Watts AMES 960GD-17 Installation, operation and maintenance

Campbell CR300 series Application note

Campbell

Campbell CR300 series Application note

Telegärtner STX V1 Mounting Information

Telegärtner

Telegärtner STX V1 Mounting Information

Emerson CROSBY BP SERIES INSTALLATION, MAINTENANCE AND ADJUSTMENT INSTRUCTIONS

Emerson

Emerson CROSBY BP SERIES INSTALLATION, MAINTENANCE AND ADJUSTMENT INSTRUCTIONS

Campbell CELL200 Series product manual

Campbell

Campbell CELL200 Series product manual

Franke AQUA400 Installation and operating instructions

Franke

Franke AQUA400 Installation and operating instructions

Cisco Catalyst 9400 Series Installation note

Cisco

Cisco Catalyst 9400 Series Installation note

ZyXEL Communications N-611 user manual

ZyXEL Communications

ZyXEL Communications N-611 user manual

AHS Antriebstechnik 6410 Application note

AHS Antriebstechnik

AHS Antriebstechnik 6410 Application note

Rohm LAPIS Semiconductor ML22620 manual

Rohm

Rohm LAPIS Semiconductor ML22620 manual

Tyco DV-3 manual

Tyco

Tyco DV-3 manual

Watts 909 Series Basic installation instructions

Watts

Watts 909 Series Basic installation instructions

HPE LSWM124XG2Q user guide

HPE

HPE LSWM124XG2Q user guide

UTC Fire and Security Interlogix VR1910 Installation & operation instructions

UTC Fire and Security

UTC Fire and Security Interlogix VR1910 Installation & operation instructions

DEOS RTC 1010 user guide

DEOS

DEOS RTC 1010 user guide

Vincotech flowPHASE 0 quick start guide

Vincotech

Vincotech flowPHASE 0 quick start guide

IBM AR-B3001 manual

IBM

IBM AR-B3001 manual

Fleck ELECTRONIC SE manual

Fleck

Fleck ELECTRONIC SE manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.