jobAid
1
DESCRIPTION
The OC-48/STM-16 DWDM 1559.79nm 80 km SFP (DWDM SFP)
is a full duplex serial electric, serial optic device with both
transmit and receive functions contained in a single module that
provides a high speed serial link at SONET OC-3, OC-12, OC-48,
SDH STM-1, STM-4, STM-16, and GigE rates. The DWDM SFP
operates on Optical Channel 22 (1559.79 nm). When installed in
the appropriate host module, the DWDM SFP provides an optical
interface to the supporting system.
The transmit side of the DWDM SFP converts serial NRZ
electrical data at the line rate to a standard compliant optical
signal. The receive side converts the incoming DC balanced serial
NRZ optical data at the line rate into serial electrical data.
NOTE
To ensure compatibility, refer to the documentation provided
with the host module.
The DWDM SFP supports the following features:
•1559.79 nm optical signals for up to 80 km reach
•Low power consumption (<1.5 W max)
•Bit error rate 10^–12
CAUTION
!
Due to compliance certification requirements, use only SFPs/
XFPs supplied by ADTRAN with the host module. ADTRAN
cannot certify system integrity with other SFP/XFPs.
Small Form-Factor Pluggable
OC-48/STM-16 DWDM 1559.79nm 80 km SFP
OPERATIONAL SPECIFICATIONS
•Channel Spacing: 100 GHz
•Data Rate: 150 Mbps to 2.5 Gbps
•Optical distance: 80 km nominal
•Transmit Wavelength: 1559.79 nm (Channel 22)
•Receive Wavelength: 1525nm to 1565 nm
•Optical transmit levels: 0.0 to +5.0 dBm
•Spectral Width: 0.4 nm (20 dB spectral width)
•Extinction Ratio: 8.2 dB
•Optical receive level: –29.0 dBm to –8.0 dBm
•Receiver Damage Threshold: –5.0 dBm
•Optical Path Penalty: 2.0 dB max
•Minimum Span Attenuation: 13 dB
•Optical Budget: –27 dB
•Dispersion Tolerance: 1600 ps/nm
•Optical connectors: LC
•Environmental Support:
oOperational temperature range: –40°C to +65°C
oStorage temperature range: –40°C to +85°C
oRelative humidity: up to 85%, noncondensing
INSTALLATION
To install the DWDM SFP into an appropriate module, complete
the following steps:
1. Inspect the DWDM SFP. If damaged, file a claim with the
carrier and then contact ADTRAN Customer Support.
CAUTION
!
Do not remove the protective end cap from the SFP until the fiber
optic cable is ready to be connected.
2. Insert the DWDM SFP into the SFP cage on the module.
Ensure that the manufacturer label on the SFP is facing
upward for correct installation.
3. Slide the DWDM SFP all the way into the receptacle until
there is an audible “click.”
NOTE
Use the latch on the DWDM SFP to remove the SFP from the SFP
cage mounted on the printed circuit board.
CLEI: SOOTALWJ__
Product P/N: 1442707G2
Issue Date: October 2011
Document P/N: 61442707G2-22A
Warranty: ADTRAN will replace or repair this product
within the warranty period if it does not meet its
published specifications or fails while in
service. Warranty information can be found
online at www.adtran.com/warranty.
©2011 ADTRAN, Inc. All Rights Reserved.
ADTRAN CUSTOMER CARE:
From within the U.S. 1.800.726.8663
From outside the U.S. +1 256.963.8716
PRICING AND AVAILABILITY 1.800.827.0807
*61442707G2-22A*
C A U T I O N
C A U T I O N
!
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
The DWDM SFP is to be installed in ADTRAN products in
Restricted Access Locations only, and installed by trained service
personnel.
This device complies with Part 15 of the FCC rules. Operation is
subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including
interference that may cause undesired operation.
Changes or modifications not expressly approved by ADTRAN
could void the user's authority to operate this equipment.
The DWDM SFP is designed to meet the following environmental
classes:
•ETSI EN 300 019-1-1 “Classification of environmental
conditions; Storage,” Class 1.2
•ETSI EN 300 019-1-2 “Classification of environmental
conditions; Transportation,” Class 2.3
•ETSI EN 300 019-1-3 “Classification of environmental
conditions; Stationary use at weather-protected locations,”
Class 3.3
The equipment is designed to function without degradation
during exposure to all test severities per Class 3.3 of ETSI EN 300
019-1-3.
The OC-48/STM-16 DWDM 1559.79nm 80 km SFP meets EU
RoHS Directive 2002/95/EC and/or applicable exemptions. Refer
to www.adtran.com for further information on RoHS/WEEE.
SAFETY AND REGULATORY COMPLIANCE
WARNING
!
Read all warnings and cautions before installing or servicing this
equipment.
CAUTION
C
This product contains a Class 1 Laser module that complies with
21 CFR 1040.10 and 1040.11 and IEC 60825-1, IEC 60825-2, EN
60825-1 and EN 60825-2. For continued compliance with the
above standards, only approved Class 1 laser modules from an
ADTRAN approved vendor list (located on the ADTRAN
website) should be installed in this product. ADTRAN cannot
certify system integrity with other laser modules.
CAUTION
!
• Electrostatic Discharge (ESD) can damage electronic modules.
When handling modules, wear an antistatic discharge wrist
strap to prevent damage to electronic components. Place
modules in antistatic packing material when transporting or
storing. When working on modules, always place them on an
approved antistatic mat that is electrically grounded.
• Per GR-1089-CORE this product is designed and intended for
installation as part of a Common Bonding Network (CBN).
This product is not designed nor intended for installation as
part of an Isolated Bonding Network (IBN).
• Per GR-1089-CORE Section 9, this product does not have an
internal DC connection between battery return and frame
ground. This product can be installed in a DC-I (isolated) or
DC-C (common) installation. For installations where other
cards or the host system have internal connections between
battery return and frame ground, the system would be
intended for deployment only in a DC-C installation.
• The chassis frame ground terminal must be connected to an
earth ground to ensure that the front panel of the module is
properly grounded via the backplane connector.
NOTE
• The Gigabit Ethernet port(s) are optical and therefore are not
classified as any type of port as defined in Appendix B of GR-
1089-CORE.
• This DWDM SFP is compliant with SFF-8472 “Digital
Diagnostics Monitoring Interface for Optical Transceivers,”
Revision 9.3.
• This DWDM SFP is compliant with the XFP Multi-Source
Agreement (MSA).
• This DWDM SFP is designed to be deployed in GR-3108-CORE
environmental class 1 or 2 as defined in GR-3108-CORE.
The DWDM SFP meets or exceeds all the applicable requirements
of NEBS, Telcordia GR-63-CORE, GR-1089-CORE, and ETSI EN
300368. The DWDM SFP is intended for deployment in Central
Office type facilities, EEEs, EECs, and locations where the NEC
applies (for example, Customer Premises).

This manual suits for next models

1

Other ADTRAN Control Unit manuals

ADTRAN Octal BRI/U User manual

ADTRAN

ADTRAN Octal BRI/U User manual

ADTRAN SFP GPON ONU User manual

ADTRAN

ADTRAN SFP GPON ONU User manual

ADTRAN Quad T1 User manual

ADTRAN

ADTRAN Quad T1 User manual

ADTRAN Octal BRI S/T User manual

ADTRAN

ADTRAN Octal BRI S/T User manual

ADTRAN 1200261L1 User manual

ADTRAN

ADTRAN 1200261L1 User manual

ADTRAN SFP User manual

ADTRAN

ADTRAN SFP User manual

ADTRAN Job Aid+ 1442707G1 User manual

ADTRAN

ADTRAN Job Aid+ 1442707G1 User manual

ADTRAN Job Aid+ 1442704PG2 User manual

ADTRAN

ADTRAN Job Aid+ 1442704PG2 User manual

ADTRAN U-BR1TE Instruction Manual

ADTRAN

ADTRAN U-BR1TE Instruction Manual

ADTRAN SFP User manual

ADTRAN

ADTRAN SFP User manual

ADTRAN Job Aid+ 1442971GX User manual

ADTRAN

ADTRAN Job Aid+ 1442971GX User manual

ADTRAN IMUX-56 User manual

ADTRAN

ADTRAN IMUX-56 User manual

ADTRAN Total Access 351 Series User manual

ADTRAN

ADTRAN Total Access 351 Series User manual

ADTRAN Total Access 300 Series User manual

ADTRAN

ADTRAN Total Access 300 Series User manual

ADTRAN GPON D OLT User manual

ADTRAN

ADTRAN GPON D OLT User manual

ADTRAN 1200068L1 HS Series User manual

ADTRAN

ADTRAN 1200068L1 HS Series User manual

ADTRAN SFP User manual

ADTRAN

ADTRAN SFP User manual

ADTRAN 1442442F1 User manual

ADTRAN

ADTRAN 1442442F1 User manual

ADTRAN Job Aid+ 1442910G1 User manual

ADTRAN

ADTRAN Job Aid+ 1442910G1 User manual

ADTRAN Octal User manual

ADTRAN

ADTRAN Octal User manual

ADTRAN E1 User manual

ADTRAN

ADTRAN E1 User manual

ADTRAN MX2820 SCU User manual

ADTRAN

ADTRAN MX2820 SCU User manual

ADTRAN Job Aid+ 1442982G7C User manual

ADTRAN

ADTRAN Job Aid+ 1442982G7C User manual

ADTRAN T200 H2TU-R User manual

ADTRAN

ADTRAN T200 H2TU-R User manual

Popular Control Unit manuals by other brands

M-system R3-AV4 instruction manual

M-system

M-system R3-AV4 instruction manual

Eaton DeviceNet user manual

Eaton

Eaton DeviceNet user manual

Energeeks EG-VALV001 Quick installation guide

Energeeks

Energeeks EG-VALV001 Quick installation guide

LEAMING INDUSTRIES AGC432 Instruction book

LEAMING INDUSTRIES

LEAMING INDUSTRIES AGC432 Instruction book

Parker PSSTACM12A Installation & service instructions

Parker

Parker PSSTACM12A Installation & service instructions

VIPA IM Series manual

VIPA

VIPA IM Series manual

Siemens LMV52 series user manual

Siemens

Siemens LMV52 series user manual

Avalue Technology ESM-2850 Quick installation guide

Avalue Technology

Avalue Technology ESM-2850 Quick installation guide

VAT 29 Series Installation, operating,  & maintenance instructions

VAT

VAT 29 Series Installation, operating, & maintenance instructions

Unex SOM-300 Series quick start guide

Unex

Unex SOM-300 Series quick start guide

ABB CMS-660 user manual

ABB

ABB CMS-660 user manual

Sinopulsar SPTS01 user manual

Sinopulsar

Sinopulsar SPTS01 user manual

G.R.A.S. 12AR instruction manual

G.R.A.S.

G.R.A.S. 12AR instruction manual

Beta LaserMike LASERSPEED 8000 Instruction handbook

Beta LaserMike

Beta LaserMike LASERSPEED 8000 Instruction handbook

Link 600 Series installation instructions

Link

Link 600 Series installation instructions

Axion 40 Series user manual

Axion

Axion 40 Series user manual

Neptune Systems AI Wireless Module Setup guide

Neptune Systems

Neptune Systems AI Wireless Module Setup guide

Franklin Electric SUBDRIVE CONNECT Series Installation and operation manual

Franklin Electric

Franklin Electric SUBDRIVE CONNECT Series Installation and operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.