ADTRAN T200 H2TU-R User manual

Other manuals for T200 H2TU-R

5

This manual suits for next models

1

Other ADTRAN Control Unit manuals

ADTRAN Total Access 300 User manual

ADTRAN

ADTRAN Total Access 300 User manual

ADTRAN Type 400 User manual

ADTRAN

ADTRAN Type 400 User manual

ADTRAN T400 Maintenance and service guide

ADTRAN

ADTRAN T400 Maintenance and service guide

ADTRAN NetVanta Octal T1/E1 Wide Module User manual

ADTRAN

ADTRAN NetVanta Octal T1/E1 Wide Module User manual

ADTRAN SFP GPON ONU User manual

ADTRAN

ADTRAN SFP GPON ONU User manual

ADTRAN IMUX-56 User manual

ADTRAN

ADTRAN IMUX-56 User manual

ADTRAN Total Access 300 Series Product manual

ADTRAN

ADTRAN Total Access 300 Series Product manual

ADTRAN Octal E&M User manual

ADTRAN

ADTRAN Octal E&M User manual

ADTRAN Modem-16 Module User manual

ADTRAN

ADTRAN Modem-16 Module User manual

ADTRAN Async-232 User manual

ADTRAN

ADTRAN Async-232 User manual

ADTRAN Job Aid+ 1442910G1 User manual

ADTRAN

ADTRAN Job Aid+ 1442910G1 User manual

ADTRAN FXS+ Quad User manual

ADTRAN

ADTRAN FXS+ Quad User manual

ADTRAN NetVanta SHDSL User manual

ADTRAN

ADTRAN NetVanta SHDSL User manual

ADTRAN U-BR1TE Instruction Manual

ADTRAN

ADTRAN U-BR1TE Instruction Manual

ADTRAN Job Aid+ 1442704PG2 User manual

ADTRAN

ADTRAN Job Aid+ 1442704PG2 User manual

ADTRAN Total Access 300 Series User manual

ADTRAN

ADTRAN Total Access 300 Series User manual

ADTRAN TRACER QUAD E1 User manual

ADTRAN

ADTRAN TRACER QUAD E1 User manual

ADTRAN OC-3 User manual

ADTRAN

ADTRAN OC-3 User manual

ADTRAN Job Aid+ 1442971GX User manual

ADTRAN

ADTRAN Job Aid+ 1442971GX User manual

ADTRAN 1200315L1 User manual

ADTRAN

ADTRAN 1200315L1 User manual

ADTRAN E1 User manual

ADTRAN

ADTRAN E1 User manual

ADTRAN SFP User manual

ADTRAN

ADTRAN SFP User manual

ADTRAN SFP User manual

ADTRAN

ADTRAN SFP User manual

ADTRAN E220 HFAC HDSL Product manual

ADTRAN

ADTRAN E220 HFAC HDSL Product manual

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
For more information, refer to the Installation and Maintenance Practice (P/N 61223HDSL2L2-5) available online at www.adtran.com.
HDSL2
T200 H2TU-R
P/N: 1223024L2
CLEI: T1L8FJFC_ _
T200 H2TU-R, Locally Powered
TX
RX
REM
LOC
L
B
K
1223024L2
DSL
LOCAL
DS1
ALM
(GRN)
SF
(YEL)
ESF/
(GRN)
AMI
(YEL)
B8ZS
/
(GRN)
RLB
(YEL)
LLB
/
URH T
C
U
S
R
S
2
3
2
T
M
O
N
*61223024L2-22B*
POWERING MODES
This T200 H2TU-R is locally powered only. If a span powered H2TU-R is required,
order P/N 1223026L2.
RS-232 DB-9 CONNECTOR
Used to access performance monitoring data, perform loopbacks, and provision units
via VT100 emulation applications, such as HyperTerminal - Private Edition.
♦There are two types of terminal emulation modes:
♦Manual Emulation Mode: Press the spacebar three times to manually update the
screen. Print screen and log file commands are available in this mode.
♦Real-Time Emulation Mode: The default mode. Print screen and log file
commands are not available in this mode. Cursor placement and screen
highlighting are enabled.
Use CTRL+T to toggle between the two terminal emulation modes.
♦Provision terminal port for VT100 as follows:
♦Data Rate: 1.2 to 19.2 kbps
♦Asynchronous Data Format: Eight data bits, no parity (none), one stop bit
♦When using a PC with terminal software, disable any power saving programs.
PUSHBUTTON LOOPBACK FUNCTIONS
♦LOC - Initiates a bidirectional loopback of the H2TU-R toward the network and
customer
♦REM - Initiates a bidirectional loopback at the H2TU-C toward the network and
customer
DS1 BRIDGING (BANTAM) JACKS
If the DS1 test set is optioned for MONITOR, the monitor jacks provide a nonintrusive
tap onto the signal line.
♦TX - Monitors the data stream being received from the customer equipment
♦RX - Monitors the data stream being transmitted to the customer equipment
COMPLIANCE
WARNING: Up to –200 VDC may be present on telecommunications wiring.
This product is intended to be installed in Restricted Access Areas only and in
equipment with a Type “B” or “E” enclosure.
This product meets all requirements of Bellcore GR-1089-CORE (Class A2) and
ANSI T1.418-2002, and is NRTL listed to the applicable UL standards.
Code Input Output
Power Code C C
Telecommunication Code (TC) X X
Installation Code (IC) A –
LED STATUS
CARD EDGE PINOUTS
Label Status Description
DSL !Green
!Red
!Flashing
Good signal margin on the loop (> 2 dB margin above 10−7 BER)
Poor signal margin on the loop (≥ 10−7 BER)
Error detected at H2TU-C or H2TU-R (the color of this LED
matches the color representing the signal margin of the loop)
DS1 !Green
!Red
Customer-side DS1 signal is present and synchronized
Customer-side DS1 signal not detected from customer or is of a
format not matching the HDSL2 circuit provisioning
ALM "Off
!Red
!Yellow
No alarm condition detected
Local alarm condition (H2TU-R) detected
Remote alarm condition (H2TU-C) detected
ESF/SF "Off
!Green
!Yellow
Unit is provisioned for Unframed operation
Unit is provisioned for DS1 SF framing mode
Unit is provisioned for DS1 ESF framing mode
B8ZS/AMI !Green
!Yellow
Unit is provisioned for AMI coding
Unit is provisioned for B8ZS coding
LLB/RLB "Off
!Green
!Yellow
Unit is not in loopback or armed state
Active remote bidirectional loopback at the H2TU-C
Unit is in bidirectional loopback at the H2TU-R
Pin Designation Description
1CH GND Chassis ground
5DS1-T1 DS1 receive out tip (to customer interface)
7H1-T HDSL2 Loop tip (facility)
11 CH GND Chassis ground
12 GND Ground for protection switching
13 H1-R HDSL2 Loop ring (facility)
15 DS1-R1 DS1 receive out ring (to customer interface)
17 –48VR –48 VDC Return
20 VCC +5 VDC for protection switching
27 CH GND Chassis ground
35 –48V –48 VDC
40 PROT-1 Control line for protection switching
49 DS1-R DS1 transmit in ring (from customer interface)
55 DS1-T DS1 transmit in tip (from customer interface)
61223024L2-22B
0412
PRICING AND AVAILABILITY 800.827.0807
TECH SUPPORT 800.726.8663
RETURN FOR REPAIR 256.963.8722
www.adtran.com
61223024L2-22B
Warranty: ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifications or fails while in service.
Warranty information can be found online at www.adtran.com/warranty.
T200 H2TU-R, Locally Powered
TROUBLESHOOTING HDSL2
This ADTRAN HDSL2 unit is equipped with troubleshooting-at-a-glance LEDs (identified on the
reverse side of this document) that provide customers with a simple means of identifying the location
of certain faults. Additionally, screens available via the craft interface simplify the trouble isolation
process. These screens and their associated benefits are described below.
Troubleshooting Screen
Available via the Main Menu - This screen provides ADTRAN contact information and access to the
Troubleshooting Guidance and General Information screens.
Troubleshooting Guidance Screens
Available via the Troubleshooting screen - The firmware detects and displays errors and/or alarms at
any of the monitored inputs (DSX1, DS1 and HDSL). Guidance on the fault(s) detected includes
possible cause(s) and suggested actions, including those shown below:
General Information Screen
Available via the Troubleshooting screen – This is a reference page that displays the minimum
acceptable signal margin, maximum attenuation, and other deployment parameters for this HDSL2
circuit. A sample display of this screen is shown below:
Non-loaded cable pair
Single bridge tap < 2 kft
Total bridge taps < 2.5 kft
Bridge tap within 1000ft of transceiver may affect performance.
Impulse noise < 50 dBrnF (F filter)
Wideband noise < 31 dBrnF (F filter)
Power influence ≤80 dBrnC
Longitudinal Balance ≥60 dB (If using Wideband test at 196 kHz ≥40 dB)
Foreign DC Voltage (t-r, t-g, r-g) < 3 VDC
Loop Resistance ≤775 ohms
Margin ≥6 dB
Attenuation ≤28 dB
Along with the Troubleshooting screens, the Detailed Status screen and Performance History screen,
also available via the craft access port, provide both real-time and historical views of this circuit.
DSX-1/DS1:
LOS Loss of signal (Red Alarm) at the
DSX-1/DS1 receiver
CLK T1 receive clock is out of range
RAI Remote Alarm Indication (Yellow
Alarm) detected at DSX-1/DS1
receiver
AIS Alarm Indication Signal (Blue
Alarm) detected at DSX-1/DS1
receiver
ERR Errors recorded at DSX-1/DS1
receiver
Facility:
GROUND Ground Fault on span (facility pair
grounded)
SHORT Short circuit (or low impedance)
between pairs
OPEN Open circuit between facility pairs
DSL:
LOS Loss of HDSL sync
MARG Margin has exceeded the alarm
threshold
ATTEN Attenuation has exceeded the alarm
threshold
ERR Errors recorded at the HDSL receiver
HIST Performance History of the DSL units
FEATURES
TScan
This module is equipped to function with Central Office units (H2TU-C) having the TScan™feature.
TScan allows for remote retrieval of circuit diagnostics and performs advanced fault location. For more
information about TScan refer to the Installation and Maintenance practice.
Bad Splice Detection
The Runtime TScan splice detection feature is an ADTRAN proprietary non-intrusive method for
detection of anomalies (poor splice connections) in the copper plant.
Data transmission transceivers, especially echo-cancelled technologies, such as HDSL2 (or HDSL4)
are subject to degraded performance in the presence of deteriorating splice connections. This
deterioration is often undetected by normal testing methods. Often, these splices present no problem
for the data transmission equipment until the point at which oxidation within the splice itself causes a
rapid impedance change. Such a change in impedance may cause errors, signal margin fluctuation, and/
or a retrain of the DSL transceivers. To address the difficulty in identifying deteriorating splice
connections, ADTRAN has developed the splice detection feature, which non-intrusively monitors the
cable pair during runtime for the presence of deterioration.
The screen below, accessed from the troubleshooting screen, shows a suspect splice 250 feet from the
H2TU-C.
Fast Retrain
Fast Retrain is an ADTRAN proprietary feature that minimizes downtime due to an intermittent
impairment (bad splice, noise burst, etc.) which due to its duration cannot be bridged.
When such impairments occur after HDSL synchronization has been achieved, the fast retrain feature
will be invoked to restore service within 5 to 7 seconds. This short retrain time allows for reduced
downtime compared to the traditional 25 to 30 second retrain duration.
NOTE: Fast-Retrain capable units must be installed on both ends of the HDSL2 circuit for this
feature to function properly. Also, if there is a failure, for any reason, of a Fast Retrain
attempt then the traditional (25-30 second) retrain will be initiated.
Circuit ID: 06/06/04 09:29:45
Press ESC to return to previous menu
* Note: Chronic Circuit Results are only valid after all other circuit *
* qualification tests have been performed and failed to show a trouble !! *
Splice Detector Version 1 Result Definitions:
---------------------------------------------
NTF - No Trouble Found yet.
LOS - Unit not in sync.
Number - Distance from Reference point (in ft.) of suspect splice.
Reference Splice Detection Version Result Shown
Point Results Number for date
--------- ---------------- ------- MM/DD/YY
H2TUC 250 01 --------
H2TUR NTF -- 06/06/04
(B)Back