20
P/N 80-8470-0900-000 (09-19)
Definitions
Automatic Re-lock Time: After a successful unlock, unit will re-lock automatically after 3 seconds or for a duration selected in
Advanced Lock Settings (Main Menu selection #3 then #1).
All Code Lockout Mode: This feature is enabled by the Master code. When enabled, it restricts all user (except Master) PIN code
access. When attempting to enter a code while unit is in Lockout, the RED locked padlock will appear on the screen. (Main Menu
selection #6.)
Eco Mode: When enabled, Eco Mode puts unit in low power mode extending life of battery.
One Touch Locking: When unit is unlocked, activating the touchscreen will lock unit (during Automatic Re-lock duration or when
Automatic Re-lock is disabled). When One-Touch Re-lock is not in use (disabled), any valid PIN code will re-lock the lock. (Main
Menu selection #3 then #3.)
Privacy Mode: With optional Door Position Switch installed, Privacy Mode enabled thru Menu Mode and door closed, all keypad
functions can be disabled with a 3 second press of the Privacy Button. Privacy Mode is disabled by default. Enable Privacy Mode
thru Main Menu selection #3 then #4. With door closed, press and hold the privacy button until voice prompt indicates Privacy Mode
is enabled. Privacy Mode duration ends when door is opened and voice prompt indicates Privacy Mode is disabled.
Shut Down Time: Unit will shut down for sixty (60) seconds and not allow operation after wrong code entry limit (5 attempts) has
been met. When unit is in Shut down, keypad will be flashing.
Tamper Alert: Audible alarm sounds if attempting to forcibly remove outside lock from door.
User PIN Code: The User code operates the lock. Maximum number of user codes is 500.
Low Battery: When battery power is low, the Low Battery Warning indicator flashes RED. If battery power is completely lost, use the
9Volt battery override. To use the 9V battery override apply 9V battery, in either direction, to terminals on the touchscreen for backup
power option. Activate the touchscreen and enter your pin code to unlock the door.
Inside Indicator Light: This light will blink red when the trim is locked.
Network Module Setting: With the optional Network Module installed, this setting becomes available (Main Menu selection #7) and
allows the lock to connect with a network controller.
Privacy Button to Lock Door: A short 1 second press of this button will lock the door.
Volume Setting Mode: The volume setting for PIN code verification is set to HIGH (1) by default; otherwise it can be set to Low (2)
or Silent (3) for quiet areas. (Main Menu selection #4.)
Wrong Code Entry Limit: After five (5) unsuccessful attempts at entering a valid PIN code, the unit will shut down and not allow
operation for sixty (60) seconds. When the unit is in Shut Down, the keypad will be flashing.
Master PIN Code: The Master PIN code is used for programming and for feature settings. It must be created prior to programming
lock. The Master code will also operate (unlock/lock) lock.
Language Setting Mode: Choose English (1), Spanish (2) or French (3) for the lock's voice prompts. (Main Menu selection #5.)