Axis BD/TL Series User manual

USER MANUAL
BD/TL Series
File: 2014-12-08 BD_TL-162 BTL004 GB

2 OPERATION MANUAL BD/TL
__________________________________________________________________________________________________________________
Index:
1. General description .....................................................................................................3
2. Completeness .............................................................................................................3
3. Security rules...............................................................................................................4
4. Technical data............................................................................................................. 5
5. General view of balance ..............................................................................................6
6. Keys and indicators .....................................................................................................8
7. Preparation of workplace........................................................................................... 11
8. Preparation to work ................................................................................................... 11
9. General rules............................................................................................................. 12
10. Operation rules during work with accumulators (batteries) ........................................ 13
11. Accumulator exchange.............................................................................................. 14
12. Start of work .............................................................................................................. 15
13. Pieces counting (PCS) .............................................................................................. 15
14. Summation of measurements series (
.) .................................................................. 18
15. Permanent tare memory (→PT)................................................................................ 19
16. Products data library (
MEM key ).......................................................................... 20
17. Connecting to computer or printer ............................................................................ 23
18. Basic function description.......................................................................................... 25
18.1 Zeroing scale indication............................................................................................ 25
18.2 Tare ......................................................................................................................... 26
19. User menu................................................................................................................. 27
Maintenance and repairs of small defects........................................................................ 31
Declaration of Conformity................................................................................................. 33

OPERATION MANUAL BD/TL 3
__________________________________________________________________________________________________________________
1. General description
BD/TL series scales are destined for identical pieces counting and can be used
in store houses production control and similar tasks.
Counting pieces function is based on calculation individual mass of detail from
sample weight or inscribed value using keyboard. Scale avails a “learn
algorithm” during calculation to correct inaccuracy conversion.
BD/TL is equipped with summing register. The register allows addition or
subtraction of succesive measurement and observation of the register current
state.
BD/TL is equipped with data library (products base) that enables to save up to
1000 products, wherein 30 products can be saved to handy data library (that
enables choosing product by using only one key).
Most effective way to work with products labeled by barcode e.g. EAN13 is to
use connection with barcode reader (option). Readout of barcode recalls product
from data library (products base).
Scale conforms European Union safety regulations and is marked with CE
sign.
PKWiU classification: : 33.20.31.
2. Completeness
Standard set consist of:
1. Scale
2. Support pan
3. Overlay pan
4. Feeder
5. Accumulator –1 piece (option)
6. User manual
7. Guarantee card

4 OPERATION MANUAL BD/TL
__________________________________________________________________________________________________________________
3. Security rules
To avoid electrical shock or damage of the scale or
connected peripheral devices, it is necessary to follow
the security rules below.
All repairs and necessary regulations can be made by authorised
personnel only.
To avoid fire risk use a feeder of an appropriate type (supplied with the
scale). Pay attention that supply voltage is compatible with specified
technical data.
Do not use the scale when its cover is opened.
Do not use the scale in explosive conditions.
Do not use the scale in high humidity.
If the scale seems not to operate properly, unplug it from the mains and
do not use until checked by authorised service.
According to legal regulations it if forbidden to
dispose wasted electronic equipment in waste
containers.
Please return wasted scale to the point of purchase or other company
specialised in recycling of wasted electronic components.

OPERATION MANUAL BD/TL 5
__________________________________________________________________________________________________________________
4. Technical data
Scale type
BD1.5TL
BD3TL
BD6TL
BD15TL
BD30TL
Load (Max)
1.5kg
3kg
6kg
15kg
30kg
Readout unit (d)
0,5g
*0,05g
1g
*0,1g
2g
*0,2g
5g
*0,5g
10g
*1g
Tare range
-1.5kg
-3kg
-6kg
-15kg
-30kg
Pan dimensions
300x210mm
Working temperature
-10°C ÷+40°C
Weighing time
<3s
Scale dimensions
335x320x110mm
Scale weight
3,5kg
Supply
~230V 50Hz 6VA / =12V 1,2A (external feeder)
Accumulator
EP 4.5 - 6 (4,5Ah 6V)
Products base:
- Handy products quantity
- All products quantity
Users bank:
-Users qunatity
2 x 15 products
1000 products
5 users
Continous working time on accumulators
2200mAh
about 48 h with display backlighting
about 100h without backlighting
Automatic turn-0ff time when with
accumulators
> 5 min (AutoOFF function)
Backlighting automatic turn-off when with
accumulators
> 30 s (b_LIGHt function)
*optional readout units designed not for verification (on demand)
Scale type
BD3TLY
BD6TLY
BD12TLY
BD30TLY
Load (Max)
3kg
6kg
12kg
30kg
Readout unit (d)
0,5g
1g
2g
5g
Verification unit (e)
0,5g
1g
2g
5g
Tare range
-3kg
-6kg
-12kg
-30kg
Class
III
Pan dimensions
300x210mm
Work temperature
-10°C ÷+40°C
Weighing time
<3s
Scale dimensions
335x320x110mm
Scale weight
3,5kg
Supply
~230V 50Hz 6VA / =12V 1,2A (zasilacz zewnętrzny)
Accumulator
EP 4.5 - 6 (4,5Ah 6V)
Products base:
- Handy products quantity
- All products quantity
Users bank:
Users qunatity
2 x 15 products
1000 products
5 users
Continous working time on accumulators
2200mAh
about 48 h with display backlighting
about 100h without backlighting
Automatic turn-0ff time when with accumulators
> 5 min (AutoOFF function)
Backlighting automatic turn-off when with
accumulators
> 30 s (b_LIGHt function)

6 OPERATION MANUAL BD/TL
__________________________________________________________________________________________________________________
5. General view of balance
Front view:
1 –Overlay pan 4 –keyboard
2 –suport pan (under overlay p.) 5 –level
3 –display 6 –rotary legs
Back view:
Back view - option with additional displays:
6
3
5
1
2
4

OPERATION MANUAL BD/TL 7
__________________________________________________________________________________________________________________
Interfaces view:
Attention:
+5V (option) supply in RS232C joint is installed only in scales ordered together
with a scanner. In that case the scanner doesn’t need feeder.
Feeder
RxD (receiver)
TxD (transmitter)
gnd
RS232C 1
2
3
4
5
6
7
8
9
USB Supply
+5V
(option)

8 OPERATION MANUAL BD/TL
__________________________________________________________________________________________________________________
6. Keys and indicators
Keys placement:
Keys description:
- turn on/off,
- print key (complies with port and print settings),
- scale zeroing key (verificated scale),
- scale tare key,
- short press –enter user menu,
- hold –enter user identification menu (when option is active ; release
key to choose the actual user that is displayed),
- short press –permanent tare menu,
- hold –predefined tare menu (release key to choose the actual tare),
- short press- adding actual netto weight / details quantity to TOTAL
register,
- hold –TOTAL menu access (release key to choose the actually displayed
option)

OPERATION MANUAL BD/TL 9
__________________________________________________________________________________________________________________
- short press –substraction of actual netto weight / details quantity from
TOTAL register,
- hold –TOTAL menu acces (release key to choose actually displayed
option)
- short press –pieces counting on (putting defined quantity of pieces on
pan),
- hold –PCS menu access (release key to choose actually displayed
option),
- short press –pieces counting on (taking off pieces from pan),
- hold –PCS menu access (release key to choose actually displayed
option),
- DATA display working mode change (in cycles: off/gross/tare/ unitary
mas/total/thr),
- unit change (in cycles: g/kg/lb),
- changing mode key (nr or id),
- cancel operation key,
- confirm operation key,
- range switch 1÷15 or 16÷30 for record library,
- short press –inserting record number or id (MODE key switches) to
recall record from memory,
- hold –inserting number or code (MODE key switches) of the record to
save/edition,
- unitary mass inserting,
…
- numerical values keyboard,
…
- short press –fast recalling record 1÷30 from memory
(handy products),
- hold –save/edition menu of product as 1÷30 record,

10 OPERATION MANUAL BD/TL
__________________________________________________________________________________________________________________
Scale indications:
Scale display is divided into three sections: WEIGHT - upper, DATA - middle
and COUNT - lower. Each of these sections has its own measurement indication
and information indicators that complement main information or describe scale
state. Indicator is active when there is a ◄mark next to it. On above screen
, o and M1 indicator is active.
In scales with additional displays on the back each display corresponds to proper
section (WEIGHT, DATA i COUNT).
Indicators section WEIGHT:
indicator
-measurement result stabilization,
indicator
0
-zeroing indicator (unloaded scale),
indicator NET
-netto weight (after using Tkey),
indicator o
-signalizes active Autotare option (AutotA) / in scale’s menu
indicates if function is on (indicator indicates) or off (without
indicator),
Indicators section DATA:
indicator B/G
-signalizes displaying gross weight,
indicator T
-signalizes displaying actual tare,
indicator APW
-signalizes displaying average unitary weight,
indicator
-signalizes displaying summing register.
Indicators section COUNT:
indicator M1
-records baze range 1÷15 active,
indicator M2
-records baze range 16÷30 active,
indicator PCS
-pieces counting,
◄
◄
◄
0.0
g

OPERATION MANUAL BD/TL 11
__________________________________________________________________________________________________________________
indicator ▲
-signalizes that APA option (automatic improving of pieces
counting accuracy)is on / in scale’s menu indicates if function
is on (indicator indicates) or off (without indicator).
7. Preparation of workplace
Workplace of scale should be chosen carefully. This place should be assured a
proper temperature and essential area for attendance. Weight should stand on
stable table.
Violent movements of air, dust, vibrations, violent changes of temperature or
humidity above 90% are inadmissible. Scale should be far off from strong
electromagnetically or magnetically fields.
8. Preparation to work
1. Take the scale, pan and feeder out of the package. It is recommended to keep
the original scale package in order to transport the balance safely in future.
2. Place the scale on a stable ground not affected by mechanical vibrations and
airflows.
3. Put a support pan 2in wholes.
4. Put the overlay pan 1.
5. Level the scale with the rotating rear legs 6so that the air bubble in the water-
level 5 at the front of the scale is in the middle.
1
2
5
6

12 OPERATION MANUAL BD/TL
__________________________________________________________________________________________________________________
9. General rules
1. It is advised to check scale indication accuracy before and after series of
measurement using any load with known weight. To check the scale with legal
verification uses a calibration weight with valid calibration certificate. In case
permissible error is exceeded it is advised to contact the nearest service to
calibrate the scale.
2. Weighed sample should be placed in the centre of the pan.
3. The scale is equipped with a tare equal to its range. To tare the scale press
Tkey. Storing a tare value does not extend measuring range, but only
subtracts it from a load placed on a pan.
4. Weighing result should be read when the indicator " " lights, which
signalizes stabilization of a result.
5. When the scale is not used but it is necessary to be ready to work
immediately, it can be switched off by pressing I/ key. The scale reading
system is then switched off to "standby" mode. To switch the scale on press
I/ key. The scale is immediately ready to operate maximum accuracy (after
self tests).
6. Before each measurement make sure that zero indicator is displayed. If zero
indicator does not displayed or “----“ communicate appears, press 0key
and wait until zero indication and zero indicator appears
7. The mechanism of scale is a precision devices and susceptible on congestions,
impacts and mechanical shakes.
If scale has been moved from places with low temperature to places with
high temperature (for example in winter), before connecting the scale to
supply leave it for about 4 hours in purpose of acclimatization.
Do not overload the scale more then 20% of maximum load (Max).
Do not press a pan by hand.
Niedopuszczalne jest naciskanie szalki ręką.
Scale should be protected during the transport.

OPERATION MANUAL BD/TL 13
__________________________________________________________________________________________________________________
10. Operation rules during work with accumulators (batteries)
1.Scale can be powered from ~230V supply through feeder attached with scale.
Moreover accumulators, which are placed in container inside the scale, can be
used for powering. Ordinary batteries can be used as well.
2.In order to make accumulators (batteries) discharging time longer, automatic
switching off display backlight and later the whole scale further is possible
during breaks in weighing. Configuration of these mechanisms is done using
b_LIGHT and Auto OFF functions.
3.Charging accumulators is performed automatically after connecting feeder to
the scale, also during weighing. Accumulator power level can be read using
bAttErY function (bat LEVEL option).
When using batteries in place of accumulators, charging during
work with feeder have to be switched off. bAttErY function is used
for this purpose (bAt OFF option), which is described in further
part of manual. Charging batteries can cause their breaking and
serious damage of the scale.

14 OPERATION MANUAL BD/TL
__________________________________________________________________________________________________________________
11. Accumulator exchange
1.Remove the pan carefully.
2.Invert the scale.
3.Remove the cover 12.
4.Unscrew tab bolts 16, remove accumulator clamp 15, remove sleeves 13 ,
remove used accumulator 14.
5.Sleeves 13 put on new accumulator 14 , check the polarization (on
accumulator + indicated by red color put sleeve with red color).
6.Arrange accumulator, put accumulator clamp 15 and screw bolts 16 .
7.Put on cover 12.
8.Invert the scale.
9.Put on pan carefully.
12
14
13
15
16
red color

OPERATION MANUAL BD/TL 15
__________________________________________________________________________________________________________________
12. Start of work
Leave the pan empty, plug the feeder to the mains (~230V/50Hz) and plug the
feeder connector to the 12V power socket at the bottom side of the scale.
Scale will execute following step:
- display type of scale and version of program,
-zeroing the indication.
After displaying an indication on the upper display section scale is ready to work.
13. Pieces counting (PCS)
Scale enables to count identical pieces, e.g. turnbuckles or buttons.
Measurement with unitary weight calculated from given sample:
A measurement is performed in two phases:
-first phase - single piece weight calculation on the basis of defined pieces amount
(default is 10 pieces.),
-second phase –pieces counting
1. Put on pan quantified details sample.
2. Turn on pieces counting by pressing
PCS+ key.
3. Place 10 then press Enter communicate will appear. If the quantified sample
consists 10 pieces press ENTER. If amount of detail is other write correct value
by using numeric keys and press ENTER.
4. Number of details is diplayed on lower section of display with PCS indicator.
A single piece mass is displayed in middle section with APW indicator.
5. Remove sample form pan and put a portion of pieces to count.
6. Result of calculation is read from lower section display.
◄
◄
◄
Place
10
then

16 OPERATION MANUAL BD/TL
__________________________________________________________________________________________________________________
Measurement with single pieces removing from pan:
A measurement is performed in two phases:
-first phase - single piece weight calculation on the basic of removed pieces
(default is 10 pieces),
-second phase –recalculating pieces in weighting portion.
1. Turn pieces counting by pressing
PCS- key.
2. Place total then press Enter communicate will appear. Put on the pan container
with details portion to count and press ENTER.
3. Remove 10 then press Enter communicate will appear. Remove one or more
details from the portion.
4. If ten details is removed press ENTER key. If amount of removed pieces is
other write correct value by using numeric keys and then press ENTER.
5. Number of details has been showed on lower section display with PCS
indicator.A sample mass has been showed in middle section display with
APW indication.
6. Result of calculation is read from lower section display.
Turning off pieces counting option is possible by holding
PCS+ or
PCS-
key and releasing it when PCSoFF displays.
◄
◄
◄
Place
total
then
◄
◄
◄
Remov
10
then

OPERATION MANUAL BD/TL 17
__________________________________________________________________________________________________________________
Change/write a unitary mass using numeric keys:
During pieces counting (indicator PCS) user can change actual sample mass.
Writing a sample mass when counting process is turned-off initiates counting
process.
1. Press
SPW key.
2. Write sample mass using numeric keys and press ENTER.
3. Number of details is displayed on lower display section with PCS indicator.A
unitary mass is displayed in middle display section with APW indicator. The
upper display section displays sample mass.
4. Result of calculation is read from lower display.
Note:
1. It is advised that single piece weight is not less than one reading unit and
sample weight used in first phase is bigger than 100 reading units.
2. If the unit mass (APW) is smaller than scale readout unit but bigger than 1/10
of readout unit, a APW LOW communicate appears and the counting result
blinks. If the unit mass is smaller than 1/10 of readout unit, APW to LOW
communicate appears and pieces counting is disabled.
SPW
_
g

18 OPERATION MANUAL BD/TL
__________________________________________________________________________________________________________________
14. Summation of measurements series (.)
Scale is equipped with summation register. The register enables adding
successive results of measurements.
1. Put weighted element on the pan and press
+button.Contents of this
register have been showed temporary in middle section display, the upper
section displays Total sign.
Note: Using a
-key causes subtraction of actual measurement from the
register.
2. Press several times DATA key for continuous displaying of register value –in
this case an indicator is turn-on.
Hold
+ or
- key for more options:
- View –viewing summing register value; pressing
+or
-key again will
cause displaying average value and measurements quantity,
- Print –report printout,
- Reset –reset summing register,
- Auto/Manual –switching working mode to automatic or manual.
We choose option by releasing chosen key (
+ or
- ) when proper option
is displayed.
◄
◄
◄
Total
114.8
g

OPERATION MANUAL BD/TL 19
__________________________________________________________________________________________________________________
15. Permanent tare memory (→PT)
The scale can store up to 10 tare values in memory that can be later recalled. The
option enables gross weight measurement (pieces quantity) of product in for eg.
container of known weight, and then readout of calculated net weight (pieces
quantity).
1. To save permanent tare value into memory put object (eg. empty container) on
pan and press →PT . Below screen will be displayed:
2. In lower section display successive tare memory numbers will appear from
tare 1 to tare 10. By using ENTER key user can select proper tare memory
number, where actual weight value is saved.
To recall saved earlier tare value press and hold →PT. Successive tare numbers
and their values will display. Releasing →PT key chooses actually displayed
tare.
Ptare
save
tare 1

20 OPERATION MANUAL BD/TL
__________________________________________________________________________________________________________________
16. Products data library (MEM key )
The scale is equipped with data library where user can save 1000 details.
Products base consists of:
- M no - record number (M0001÷1000), needed to recall to it,
- M Id –product code, inscribed by using keyboard or scanner,
- APW –product unit mass, used for pieces counting,
- SAMPL –inscribing quantity of products, above which counting results
correction algorithm turns on,
- PtArE –inscribing constant tare for product (not necessary),
- thr Lo –lower threshold value (not necessary),
- thr Hi –upper threshold value (not necessary),
- thr Zr -zero threshold value (not necessary).
During scale work, barcode reader readout of record number causes searching
through scale product library and in case of finding the right record recalling to
single piece mass and other product data.
Database can be built in Excel datasheet form, where each product has one row
and each column have product data. This way created database, saved in *.csv
extension with semicolons can be send to scale using Scale Database software
and scale’s serial interface. Scale Database is available on our webpage
www.axis.pl/en.
Handy products banks
The scale is equipped with two handy detail banks: M1 and M2, that are related
to fast choice keys M01÷M15 and M16÷M30. Each key recalls proper number
record. Switching between handy detail banks is done by pressing MEM1/MEM2
key (indicator on lower section display changes position from M1 to M2 or vice
versa signalizing which bank is used at the moment).
fast choice keys memory switch indicator on M1 position
Longer pressing one of the fast choice keys causes displaying chosen parameter
edition menu.
Short key pressing recalls chosen record.
◄
This manual suits for next models
4
Table of contents
Other Axis Scale manuals

Axis
Axis BDM Series User manual

Axis
Axis B/U Series User manual

Axis
Axis AKA/G Series User manual

Axis
Axis B/P Series User manual

Axis
Axis LCD GB V4 User manual

Axis
Axis B0.6D User manual

Axis
Axis ATN Series User manual

Axis
Axis AD Series User manual

Axis
Axis 4BA/T Series User manual

Axis
Axis B/E Series User manual