Axis LCD GB V4 User manual

SPECIAL FUNCTIONS
DESCRIPTION
USER MANUAL COMPLEMENT
b series
File: EO-F-005-01-08 b-41_3 LCD GB v.4

2
SPECIAL FUNCTIONS DESCRIPTION
____________________________________________________________________________________________________________________
Contents:
1.
Basic information............................................................................................................3
2.
Keys and indicators........................................................................................................4
3.
Date and time setting (dAtE) ..........................................................................................5
4.
Formulation function ( U
≡
)............................................................................................6
5.
Average calculation ( rE)...............................................................................................7
6.
Percentage weighing (F..-Pro) .......................................................................................8
7.
Animal weighing (LOC) ..................................................................................................9
8.
Maximum value (UP)....................................................................................................10
9.
Anti-disturbance filter (FIL)...........................................................................................11
10.
Checkweighing (thr) ..................................................................................................... 12
11.
Total weight function (totAL).........................................................................................15
12.
Density determination (hYdro)......................................................................................17
13.
Function Menu customisation (F..-ACt) ........................................................................19

SPECIAL FUNCTIONS DESCRIPTION
3
____________________________________________________________________________________________________________________
1. Basic information
Beside basic measuring functions all balances are equipped with the set of special
user functions.
Standard balance features the following functions:
basic set of special functions, including:
- pieces counting
- autozero
- serial port wor ing mode setting
- serial port parameters setting
- constant tare
- calibration options
On customers’ request balances may be equipped with:
additional set of special functions, including:
- percentage weighing
- formulation
- animal weighing
- maximum value
- anti-stro e filter
chec weighing
paper substance determination*
total weight function
liquid and solids density determination
This brochure describe s the functions not explained in user manual (i.e. additional
functions set).
* Functions available with special balance program (with limited use of other functions).

4
SPECIAL FUNCTIONS DESCRIPTION
____________________________________________________________________________________________________________________
2. Keys and indicators
ey - switch-on / switch-off (standby),
ey
HR - increased indication resolution,
ey
B/G - gross weight indication switch,
ey
MENU - special functions menu,
ey
→0← - zero,
ey
- print-out,
ey
switch-on / switch-off (standby),
indicator →0← - zero indicator
indicator
- result stabilisation indicator
indicator
NET - net weight indicator (indication with subtracted tare)
indicator
MODE - special function mode indicator,
bar indicator - total load indicator (graduated 0-100%)
indicator
OFF - standby (switched-off with
ey),
indicator B/G - gross weigh indicator (after pressing B/G ey)
indicator pcs - number of pieces
To enter numeric values use the following keys:
→0← - digit increase,
- decimal point,
→
T
←
- next digit,
MENU - end.
OFF
AUT
MODE
0
50
10 0
SUM
Max Min e d

SPECIAL FUNCTIONS DESCRIPTION
5
____________________________________________________________________________________________________________________
3. Date and time setting (dAtE)
This function enables to set current
date and time of internal balance
cloc and enable/disable date and
time on weighing result printouts.
Options:
- F-..-0 – deactivate date printout,
- F..-1 – activate date printout
( ey),
- F..-2 - change date and time.
The example at the left presents how
to set current date and time with F..-2
option.
Change successive numbers using
→
0
←
ey.
To move to the next position use
→
T
←
ey.
Once current date and time is set
activate it with F..-1 option.
Time format: h gg – mm
(gg - hour, m - minute).
Date format: d mm – dd
(m - month, d - day).
Year format: r - rr
(r - two last digits of a year).
0g
F..-dA
F..- 2
F..- 0
h13 - 18
h13 - 1
8
h13 - 1
9
h13 -
1
9
0g
d04 - 05
r - 06
- -
MENU
T
T
T
0
T

6
SPECIAL FUNCTIONS DESCRIPTION
____________________________________________________________________________________________________________________
4. Formu ation function (SU
≡
≡≡
≡
)
This function allows separate
weighing of several ingredients in
one container with a possibility to
control aggregated sum of all
weighed components.
Function options:
- F..-0 – leave the function to read
aggregated weight,
- F..-1 – start recipe formulation
- F..-2 – return to formulation.
Before weighing each of successive
recipe ingredients (A, B, C, etc.)
ma e sure the balance displays zero
indication or simply tare the balance
with
→
T
←
ey.
To display aggregated sum of series
of measurements, press MENU ey,
choose SU
≡
function and use F..-0
option.
Aggregated weight of the recipe is
displayed when SUM indicator is lit.
Whilst SUM indicator is displayed, it
is possible to return to the previous
formula with F..-2 option.
To finish formulation and to remove
SUM indicator press
→
T
←
ey.
Notes:
If „o” indication is displayed at the
left of the display, SU
≡
function is
active.
0 g
F..-SU
F..- 0
F..- 1
11g
12g
13g
0g
0g
36g
A
A+ B+ C
B
C
MENU
T
T
T
T
o
o
o
o
o
SUM
F..-SU
F..- 0
MENU
T
T

SPECIAL FUNCTIONS DESCRIPTION
7
____________________________________________________________________________________________________________________
5. Average ca cu ation (SrE)
This function enables to calculate average value of series of measurements. During
measurements successive values are registered automatically after result
stabilisation.
Press MENU ey and choose F..-SrE
function with
→
T
←
ey.
The following options appear:
- F..-0 - exit,
- F..-1 – average calculation.
Select F..-1 option. The balance is now
registering each stable result for
average value calculation.
Pay attention that the value is registered
only when the result is stable. Remove
the load only after „ - - ” communicate
is displayed.
The balance registers the results above
Min balance value only.
The number of successive
measurements is limited to 9999.
Press ey several times to display
average calculation information in the
sequence given below:
- number of measurements (n).
- average value (=).
Press ey for the third time to
continue measurements.
If the printer is connected, the
following report is printed:
To leave the function press MENU ey,
choose F..-SrE function and select F..-0
option.
Date: ... Time. ...
MEASUREMENTS No = ...
AVERAGE VALUE = ...
0g
0g
F..-SrE
F..- 1
10g
20g
2
15g
_
_
0g
0g
MENU
T
T
n

8
SPECIAL FUNCTIONS DESCRIPTION
____________________________________________________________________________________________________________________
6. Percentage weighing (F..-Pro)
This function enables to display
weighing result as a percentage of
a reference sample.
A measurement is performed in two
phases:
- first phase – weighing a reference
sample,
- second phase – measuring specific
sample as a percentage of
the reference sample.
Weighing result is displayed in
different format, depending on the
reference sample weight value. For
values of 0÷3,5% of weighing range
the format is “100.0”, for values
3,5÷35% it is “100.00” and 35÷100%
- “100.00”
The function has the following
options:
- F-0 – disables the function,
- F-1– stores current indication as
100% and activates percentage
weighing,
- F-2 – activates percentage weighing
with the previous reference sample
value.
„%” sign is replaced with „
_
_
”
indicator.
Note:
1. Err-3 communicate signalises that
100% alue is smaller then 0.5*Min
or not entered (see F-1).
2. When the function is acti ated
→
T
←
key function does not change.
0 g
170 g
F..-Pro
F..-0
F..-1
100.00%
50.00%
100%
50%
MENU
T
T

SPECIAL FUNCTIONS DESCRIPTION
9
____________________________________________________________________________________________________________________
7. Anima weighing (LOC)
This function allows precise animals weighing.
Press MENU ey. When LOC function
is displayed press
→
T
←
ey.
Function options:
- F..-0 – leave the function,
- F..-1 – automatic weighing after
loading the balance,
- F..-2 – the measurement initiated
manually with ey.
For automatic weighing press
→
T
←
ey when F..-1 is displayed.
Tare the balance when necessary and
place the animal on the pan.
Wait until the weighing result is
averaged (the indication blin s). Final
result is displayed on the display and
send via serial port to computer or
printer.
Remove the animal from the pan – the
result is displayed for 30s and then the
balance starts the new measurement.
Important notes:
1.The load less than Min is not a eraged.
2.In case placing the animal takes more than 5s, it is ad ised to use F..-2 option
(manual weighing with key).
0g
F..-LOC
F..- 0
F..- 1
25g
25g
PrIn
MENU
T
T

10
SPECIAL FUNCTIONS DESCRIPTION
____________________________________________________________________________________________________________________
8. Maximum va ue (UP)
This function enables to display the maximum value from the series of weighing.
Ma e sure the balance displays zero
indication before starting
measurements.
Enter the function menu with MENU
ey and choose F..-UP function. The
displayed indication is the highest
value from the series of
measurements.
Press
→
T
←
ey to zero the
indication.
Note:
Autozero function and the
stabilisation indicator are
deacti ated when UP function is
acti e. The indication is the result of
continuous a eraging of 5
measurements.
0 g
F..-UP
F..- 0
F..- 1
1g
1g
1g
10g
10g
MENU
T
T

SPECIAL FUNCTIONS DESCRIPTION
11
____________________________________________________________________________________________________________________
9. Anti-disturbance fi ter (FIL)
This function activates digital filter of
chosen intensity, which reduces the
influence of mechanical vibrations (air
blasts, base vibrations) on measurement
result. Using the filter is necessary for
accurate people or animal weighing.
Press MENU ey and choose F..-FIL
with
→
T
←
ey.
The following options appears:
- F..-0 – filter deactivated
- F..-1 - filter I (wea )
- F..-2 - filter II (average)
- F..-3 - filter III (intense)
- F..-4 - filter IV (very intense)
Choose the filter of desired intensity –
the balance is now operating with
selected filter.
To return to normal wor (deactivate
the filter) enter F..-FIL menu and
choose F..-0 option.
0 g
0 g
F..-FIL
F..- 0
F..- 1
F..- 2
F..- 4
MENU
T
T
Fil er

12
SPECIAL FUNCTIONS DESCRIPTION
____________________________________________________________________________________________________________________
10. Checkweighing (thr)
This function compares weighing
result with two reference values: lower
and upper threshold. The balance
signalises comparison result with MIN,
OK and MAX indicators and sound
signal generated when threshold values
are exceeded.
Press MENU ey and choose F..- thr
with
→
T
←
ey.
The following options are displayed:
- F..-0 – deactivate the function,
- F..-1
– activate the function,
- F..-P – chec current threshold values
(use to display successive values).
Choose F..-0 option with
→
T
←
ey.
Following options are displayed:
- SEt-0 - start the function with the
excess signalisation,
- SEt-1
- set lower threshold value,
- SEt-2
- set lower threshold value,
- SEt-3
- set zero excess signalisation,
Set the lower and the upper threshold
values with the following eys:
→0← - digit increase,
- decimal point,
→T← - next digit,
MENU - end.
To start chec weighing function use
Set-0 option.
To leave the function, press MENU ey
and choose thr and F..-0 options.
0g
F.. - hr
F.. -1
F.. -0
SE-1
SE-0
5
5 -
50
62g
MENU
MENU
T
T
T
T
0
0
T
SE-2
100
MENU
T

SPECIAL FUNCTIONS DESCRIPTION
13
____________________________________________________________________________________________________________________
Notes:
When necessary, use SEt-3 option to set the zero threshold value (indications
below this value are regarded as unloaded balance – see PROGI interface
description).
If comparison result is:
- smaller than lower threshold – the balance displays MIN,
- between threshold values - the balance displays OK with the sound signal when
exceeding the threshold,
- greater than upper threshold - the balance displays MAX with the sound signal
when exceeding the threshold,
The chec weighing results can be use to control external optical indicator or
batching devices. Standard balance is set for cooperation with the external
indicator. Dosing option is installed on customer’s request – to change external
device mode service intervention is necessary.
Threshold comparison results appear on P1-P3 output pins as a short-circuit state
(presented on the state chart on the next page).
During dosing (optional), short-circuit pulses lasting for 0.5s appear on P1 (I
threshold) and P2 (II threshold) outputs and for P3 output (zero threshold) – short-
circuit state for the indication below zero threshold.
Transmitter connection diagram
PROGI output is the open collector transoptor output with load capacity 100mA /
24V. Transmitter inputs must be protected with diodes, e.g. 1N4148.
It is advised to use MS3K/P electronic board (sold separately), consisting of
RM96P transmitters, with DC24V input voltage and AC250V, 8A output.
Important notes:
After switching the balance on, both thresholds are set as maximum alues.
When selecting upper threshold alue, pay attention that its alue is not greater
than the lower threshold alue.

14
SPECIAL FUNCTIONS DESCRIPTION
____________________________________________________________________________________________________________________
Output state charts (increasing load):
External optical indicator: Dosing (optional):
P3
P1
P2
P3
zero
zero
treshold
treshold
thr I
thr I
thr I
thr II
thr II
thr II
P1
P2

SPECIAL FUNCTIONS DESCRIPTION
15
____________________________________________________________________________________________________________________
11. Tota weight function (totAL)
The function enables to calculate total weight of series of measurements greater
than the balance capacity.
To enter the function, press MENU ey
and choose F..-tot option with
→
T
←
ey.
The following options are displayed:
- F..-P - report printout without clearing
the adding register,
- F..-0 - report printout with clearing the
adding register,
- F..-1 - report printout after each
measurement,
- F..-2 - report printout disabled.
Press
→
T
←
ey when F..-1 is displayed.
Place successive samples on the pan and
press after each measurement to store
the value in the adding register
To display current results enter F..-tot
function menu and choose F..-P option.
The results are display in the following
order:
- total weight (To al)
- number of registered measurements (n),
- average value (t
)
.
(Press ey twice).
To continue series of measurements press
ey for the third time.
0g
0g
F..- o
F..- o
F..- P
F..- 1
10g
20g
2
15g
0g
30g
0g
MENU
MENU
T
T
T
T
n
TOTAL

16
SPECIAL FUNCTIONS DESCRIPTION
____________________________________________________________________________________________________________________
To leave the function with clearing the adding register, enter F..-tot function menu
and choose F..-1 option. When connected to a printer, the balance prints the
communicate informing about clearing the register.
The sample chec for each measurement:
Report printout sample:
Note:
When the balance has not an internal clock, Date and Time do not appear
on printout. Maximum number of measurements 99 999.
Maximum total load 99 999 000d.
The weighing unit of the aggregated alue from the register (total) is the same as
the weighing unit stated on the keypad or is 1000 times greater (signalised with
“o” indicator at the left of the display).
If the registered alue is too big to be displayed, “E” communicate appears on the
display.
If the number of series is too high to be displayed, “Err1”communicate appears
on the display.
Date: ... Time ...
measurement no weight
measurement no weight
… …
Date: ... Time ...
TOTAL WEIGHT =
NUMBER OF SAMPLES =
AVERAGE VALUE =

SPECIAL FUNCTIONS DESCRIPTION
17
____________________________________________________________________________________________________________________
12. Density determination (hYdro)
This function calculates material
density basing on its weight in air
and in liquid of nown density using
the formula below:
where, m
1
– weigh in air
m
2
– weight in water
ρ
L
– density of liquid
Default liquid density is:
ρ
L
= 1g/cm
3
(distilled water).
When using liquid other than
distilled water, choose F..- hYd and
use F..-2 option to enter its density
according to its temperature.
To enter the value use the following
eys:
→0← - digit increase,
- decimal point,
→T← - next digit,
MENU
- end.
The measurement is performed in
three phases:
-measurement in air,
-measurement in liquid,
-hanger weighing.
To read density determination result,
enter F..-hYd function menu and use
F..-P option. Press ey to
display successive measurement
number. Press ey again to
display density measurement result
and to send the density value to the
printer. The balance is now ready for
the next density determination.
F.. -hYd
F.. -hYd
F.. -1
F.. -P
-
-
MENU
MENU
T
T
T
T
0g
0g
0g
0g
100g
51g
1g
2,0000
1
n
L
mm
m
ρρ
*
21
1
−
=

18
SPECIAL FUNCTIONS DESCRIPTION
____________________________________________________________________________________________________________________
To print a density determination report after all necessary measurements, connect
a printer to the balance.
Operation sequence (weighing in air and in liquid) for below-balance weighing:
Phase I: measurement in air.
Phase II: measurement in liquid.
Date: ... Time. ...
MEASUREMENT No. =
WEIGHT in air =......... g
WEIGHT in liquid = g
HANGER WEIGHT = g
LOAD DENSITY = g/cm
3
LIQUID DENSITY = g/cm
3

SPECIAL FUNCTIONS DESCRIPTION
19
____________________________________________________________________________________________________________________
13. Function Menu customisation (F..-ACt)
This function enables to select special
functions that will be displayed after
pressing MENU ey. Easy access to the
most useful functions will shorten
operation time and ma e wor more
comfortable.
Operation sequence shown on the
picture, presents how to add RS232C
parameters setting function (F..-rS) to
the Function Menu.
To remove a function from the Function
Menu choose “F..-0” in the last
operation.
0.00
F.. -AC
F.. -1
F.. -0
F1-AU
F..-rS
T
T
T

20
SPECIAL FUNCTIONS DESCRIPTION
____________________________________________________________________________________________________________________
Table of contents
Other Axis Scale manuals

Axis
Axis B Series User manual

Axis
Axis 4B/NA Series User manual

Axis
Axis B/U Series User manual

Axis
Axis ACG Series User manual

Axis
Axis AKA120 User manual

Axis
Axis AGN50 User manual

Axis
Axis BD2P User manual

Axis
Axis AGN/C Series User manual

Axis
Axis 4BA/T Series User manual

Axis
Axis BD/TL Series User manual

Axis
Axis ATA1200 User manual

Axis
Axis 4BA SERIES User manual

Axis
Axis AG Series User manual

Axis
Axis B/P Series User manual

Axis
Axis SE-12 Operator's manual

Axis
Axis B0.6D User manual

Axis
Axis BD/S series User manual

Axis
Axis BTA Series User manual

Axis
Axis BTA 2100 User manual

Axis
Axis 4BA SERIES User manual