manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. B-K lighting
  6. •
  7. Lighting Equipment
  8. •
  9. B-K lighting BKSSL Precision2 DR2 Series User manual

B-K lighting BKSSL Precision2 DR2 Series User manual

Warning Low Voltage Hot Surface
Patented HydroLock®
Barrier Plate
Assembly (ACV™)
DR2 Housing
Patented
Stability
Flange
1/8” Allen Wrench
Phillips Screwdriver
Level
Hammer
NEEDED
FOR
INSTALLATION:
By Others
Optical
Assembly
Faceplate
RELEASE DATE
12-9-16
REFERENCE NUMBER
INS-2179-00
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY
DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS
· Suitable for wet locations
IMPORTANT LISTINGS AND CERTIFICATIONS
Proper soil preparation is recommended before installation. See the DIG-IT guide at www.bklighting.com/dig-it for more information.
Quick Disconnect
DR2SERIES
Deep Housing - Solid State LED
Remote Transformer Installation Instructions
Waterproof Wire
Connectors
Soil Prep
Conduit
trench
A. Determine Soil Type by referencing
DIG-IT Guide.
B. Dig hole 24” wide and 8” deep.
Conduit
Trench
Excavated
for Housing
C. Prep soil according to DIG-IT Guide.
REMOTE WIRING
Please refer to the low
voltage design guide at
www.bklighting.com/
lvg before installation for
proper wire selection.
O-Ring
• Product must be installed by a qualified person in a manner
consistent with its intended use and in compliance with the
National Electrical Code, Canadian Electrical Code, and all Local and
Provincial Codes.
• Follow product label information and instructions.
• Qualified Personnel with appropriate personal protective
equipment must perform all servicing of this product.
• Before wiring to power supply and during servicing, turn off and
lock out power at fuse or circuit breaker before service.
• The use of accessory equipment not recommended by the
manufacturer or installed contrary to instructions may cause an
unsafe condition. The use of damaged components may cause an
unsafe condition and void product warranty.
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY
AND INSTALLATION INSTRUCTIONS
• Do not block light emanating from product in whole or part, as
this may cause an unsafe condition.
• Never operate the fixture with missing or damaged lens.
Lens must be cleaned on regular basis.
• Entire fixture may become extremely hot. Do not touch hot
lens or fixture body.
• Replace LED assembly only with correct wattage and type of
power supply appropriate for LED assembly.
• All gaskets, o-rings and sealing surfaces must be kept clean
during installation and service; failure to do this may cause an
unsafe condition and void product warranty.
INSTRUCTIONS PERTAINING TO
A RISK OF FIRE, OR INJURY TO
PERSONS IMPORTANT SAFETY
INSTRUCTIONS
Lighted fixture is HOT!
WARNING - To reduce the risk of
FIRE OR INJURY TO PERSONS:
Turn off/unplug and allow to cool before replacing LED.
Fixture gets HOT quickly! Contact only switch/plug when
turning on. Do not touch hot lens, guard, or enclosure.
Keep fixture away from materials that may burn.
Do not operate the luminaire fitting with a missing or
damaged shield. Do not touch the source at any time. Use
a soft cloth or gloves. Oil from skin may cause damage.
SAVE THESE INSTRUCTIONS
RELEASE DATE
12-9-16
REFERENCE NUMBER
INS-2179-00
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
Threaded Entry
Side Flats
1. Connect branch conduit connectors (By Others)
to the junction box using either the threaded
conduit entries on the bottom of the junction
box or through holes drilled into the sides of the
junction box.
2. Place housing in hole. Align junction box in the
path of the conduit trench.
3. Align holes to final installation orientation. Point
arrows on temporary cover toward surface to
be illuminated.
NOTE: Do not remove temporary cover until
installation of faceplate.
Flush with finished grade
5. Raise housing on EMT so housing is flush with
finished grade. Use a level to aid in leveling
housing.
6. When housing is level, tighten screws on
Patented Stability Flange™ to secure housing to
EMT. Remove excess EMT as needed.
8. Per DIG-IT Guide, backfill the gap between the
bottom of housing and bottom of hole with
sand for drainage.
Housing
9. Fill and tamp soil to the appropriate height
leaving room for sod, pavers, etc. to be level
with the top of the temporary cover.
10. Pull secondary wiring from remote transformer
to installed housing(s).
7. Connect the conduit to the conduit connectors.
4. Insert (4) pieces of ½” EMT conduit through
the Patented Stability Flange™. Hammer into
substrate until secure.
Leave sufficient clearance to elevate housing
to finished grade.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
PROJECT:
TYPE:
DR2SERIES
Deep Housing - Solid State LED
Remote Transformer Installation Instructions
RELEASE DATE
12-9-16
REFERENCE NUMBER
INS-2179-00
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
Fixture Installation
WIRING DIAGRAM1. Remove temporary cover. 2. Make watertight connections using waterproof
wire connectors (provided) to leads on the
bottom of Patented HydroLock®Barrier Plate
Assembly. See wiring diagram.
3. Wipe O-ring clean of debris on Patented
HydroLock® Barrier Plate. Install Patented
HydroLock® Barrier Plate by aligning
keyholes with dome-topped fasteners
at the bottom of the housing and
while grasping handle; push down on
Patented HydroLock® Barrier Plate until firmly
seated.
4. Turn HydroLock®
Barrier Plate clockwise ¼” to
lock.
Patented HydroLock® Barrier Plate must be
completely seated to ensure proper seal or
water may intrude. This step must be done
as stated or you will void your warranty.
6. Connect optical assembly and faceplate to
Patented HydroLock® Barrier Plate with quick
disconnect.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
PROJECT:
TYPE:
DR2SERIES
Deep Housing - Solid State LED
Remote Transformer Installation Instructions
LINE
COM
GROUND
REMOTE
TRANSFORMER
GROUND
HYDROLOCK PLATE
12V
COM
5. Carefully place O-ring into the groove on top of
housing, keep free of dirt and debris. Dirt and
debris may allow water entry into fixture.
This step must be done as stated or you will
void your warranty.
7. Secure faceplate and optical assembly to
housing with four (4) #10-24 socket head
screws as provided on faceplate with 1/8” Allen
wrench. Hand tighten screws in a cross pattern
to 30 in-lbs. to create proper seal.
Do not use a power tool to install screws. Do
not exceed 40 in-lbs.
LED - For use with 12VAC remote
transformer or magnetic transformers only.
B-K Lighting cannot guarantee performance
with third party manufacturers’ transformers.

Other B-K lighting Lighting Equipment manuals

B-K lighting MINI-MICRO DRIVESTAR User manual

B-K lighting

B-K lighting MINI-MICRO DRIVESTAR User manual

B-K lighting ORION User manual

B-K lighting

B-K lighting ORION User manual

B-K lighting ArtiStar Series User manual

B-K lighting

B-K lighting ArtiStar Series User manual

B-K lighting MB2 User manual

B-K lighting

B-K lighting MB2 User manual

B-K lighting Altair User manual

B-K lighting

B-K lighting Altair User manual

B-K lighting MICRO NITE STAR User manual

B-K lighting

B-K lighting MICRO NITE STAR User manual

B-K lighting SQUARE ADJUSTABLE WELL STAR User manual

B-K lighting

B-K lighting SQUARE ADJUSTABLE WELL STAR User manual

B-K lighting DENALI User manual

B-K lighting

B-K lighting DENALI User manual

B-K lighting ArtiStar Remote User manual

B-K lighting

B-K lighting ArtiStar Remote User manual

B-K lighting ArtiStar Remote ES16 Metal Halide User manual

B-K lighting

B-K lighting ArtiStar Remote ES16 Metal Halide User manual

B-K lighting LT User manual

B-K lighting

B-K lighting LT User manual

B-K lighting Mini-Micro Series User manual

B-K lighting

B-K lighting Mini-Micro Series User manual

B-K lighting Precision2 HP2 Series User manual

B-K lighting

B-K lighting Precision2 HP2 Series User manual

B-K lighting Precision2 HP2 Series User manual

B-K lighting

B-K lighting Precision2 HP2 Series User manual

B-K lighting RE1 User manual

B-K lighting

B-K lighting RE1 User manual

B-K lighting INTEGRAL DENALI Series User manual

B-K lighting

B-K lighting INTEGRAL DENALI Series User manual

B-K lighting Union Bollard User manual

B-K lighting

B-K lighting Union Bollard User manual

B-K lighting MINI-MICRO RECESSED UPLIGHT User manual

B-K lighting

B-K lighting MINI-MICRO RECESSED UPLIGHT User manual

B-K lighting YOSEMITE Series User manual

B-K lighting

B-K lighting YOSEMITE Series User manual

B-K lighting ArtiStar Integral User manual

B-K lighting

B-K lighting ArtiStar Integral User manual

B-K lighting BACK BOX User manual

B-K lighting

B-K lighting BACK BOX User manual

B-K lighting Union Bollard User manual

B-K lighting

B-K lighting Union Bollard User manual

B-K lighting TETON User manual

B-K lighting

B-K lighting TETON User manual

B-K lighting PRECISION2 CO2 Series User manual

B-K lighting

B-K lighting PRECISION2 CO2 Series User manual

Popular Lighting Equipment manuals by other brands

Lumatek ATS200W manual

Lumatek

Lumatek ATS200W manual

walimex 16638 instruction manual

walimex

walimex 16638 instruction manual

WE-EF FLC122LED Installation and maintenance instructions

WE-EF

WE-EF FLC122LED Installation and maintenance instructions

Lightolier FA01 specification

Lightolier

Lightolier FA01 specification

Iluminarc Ilumipod 18g2 IP Optic RGB user manual

Iluminarc

Iluminarc Ilumipod 18g2 IP Optic RGB user manual

Godox MG2400Bi manual

Godox

Godox MG2400Bi manual

Beamz Pro BAC306 instruction manual

Beamz Pro

Beamz Pro BAC306 instruction manual

Clas Ohlson LUM-112X159W1-01D manual

Clas Ohlson

Clas Ohlson LUM-112X159W1-01D manual

Cameo MOVO BEAM 200 user manual

Cameo

Cameo MOVO BEAM 200 user manual

Tronix 600-022 manual

Tronix

Tronix 600-022 manual

Living Spaces GSP-001 Assembly instructions

Living Spaces

Living Spaces GSP-001 Assembly instructions

Prolux MOVING WASH STROBE user manual

Prolux

Prolux MOVING WASH STROBE user manual

Integral LED ILSTRGBA163B Installation instruction

Integral LED

Integral LED ILSTRGBA163B Installation instruction

DÖRR REPROSTAND SET H75 instruction manual

DÖRR

DÖRR REPROSTAND SET H75 instruction manual

Sanlight Q1W DIM Operation manual

Sanlight

Sanlight Q1W DIM Operation manual

Robus RHA28405FTV2-24 quick start guide

Robus

Robus RHA28405FTV2-24 quick start guide

Anslut 005055 operating instructions