manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. B-K lighting
  6. •
  7. Lighting Equipment
  8. •
  9. B-K lighting BKSSL Precision2 DR2 Series User manual

B-K lighting BKSSL Precision2 DR2 Series User manual

Warning Low Voltage Hot Surface
Patented HydroLock®
Barrier Plate
Assembly (ACV™)
DR2 Housing
Patented
Stability
Flange
1/8” Allen Wrench
Phillips Screwdriver
Level
Hammer
NEEDED
FOR
INSTALLATION:
By Others
Optical
Assembly
Faceplate
RELEASE DATE
12-9-16
REFERENCE NUMBER
INS-2179-00
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY
DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS
· Suitable for wet locations
IMPORTANT LISTINGS AND CERTIFICATIONS
Proper soil preparation is recommended before installation. See the DIG-IT guide at www.bklighting.com/dig-it for more information.
Quick Disconnect
DR2SERIES
Deep Housing - Solid State LED
Remote Transformer Installation Instructions
Waterproof Wire
Connectors
Soil Prep
Conduit
trench
A. Determine Soil Type by referencing
DIG-IT Guide.
B. Dig hole 24” wide and 8” deep.
Conduit
Trench
Excavated
for Housing
C. Prep soil according to DIG-IT Guide.
REMOTE WIRING
Please refer to the low
voltage design guide at
www.bklighting.com/
lvg before installation for
proper wire selection.
O-Ring
• Product must be installed by a qualified person in a manner
consistent with its intended use and in compliance with the
National Electrical Code, Canadian Electrical Code, and all Local and
Provincial Codes.
• Follow product label information and instructions.
• Qualified Personnel with appropriate personal protective
equipment must perform all servicing of this product.
• Before wiring to power supply and during servicing, turn off and
lock out power at fuse or circuit breaker before service.
• The use of accessory equipment not recommended by the
manufacturer or installed contrary to instructions may cause an
unsafe condition. The use of damaged components may cause an
unsafe condition and void product warranty.
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY
AND INSTALLATION INSTRUCTIONS
• Do not block light emanating from product in whole or part, as
this may cause an unsafe condition.
• Never operate the fixture with missing or damaged lens.
Lens must be cleaned on regular basis.
• Entire fixture may become extremely hot. Do not touch hot
lens or fixture body.
• Replace LED assembly only with correct wattage and type of
power supply appropriate for LED assembly.
• All gaskets, o-rings and sealing surfaces must be kept clean
during installation and service; failure to do this may cause an
unsafe condition and void product warranty.
INSTRUCTIONS PERTAINING TO
A RISK OF FIRE, OR INJURY TO
PERSONS IMPORTANT SAFETY
INSTRUCTIONS
Lighted fixture is HOT!
WARNING - To reduce the risk of
FIRE OR INJURY TO PERSONS:
Turn off/unplug and allow to cool before replacing LED.
Fixture gets HOT quickly! Contact only switch/plug when
turning on. Do not touch hot lens, guard, or enclosure.
Keep fixture away from materials that may burn.
Do not operate the luminaire fitting with a missing or
damaged shield. Do not touch the source at any time. Use
a soft cloth or gloves. Oil from skin may cause damage.
SAVE THESE INSTRUCTIONS
RELEASE DATE
12-9-16
REFERENCE NUMBER
INS-2179-00
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
Threaded Entry
Side Flats
1. Connect branch conduit connectors (By Others)
to the junction box using either the threaded
conduit entries on the bottom of the junction
box or through holes drilled into the sides of the
junction box.
2. Place housing in hole. Align junction box in the
path of the conduit trench.
3. Align holes to final installation orientation. Point
arrows on temporary cover toward surface to
be illuminated.
NOTE: Do not remove temporary cover until
installation of faceplate.
Flush with finished grade
5. Raise housing on EMT so housing is flush with
finished grade. Use a level to aid in leveling
housing.
6. When housing is level, tighten screws on
Patented Stability Flange™ to secure housing to
EMT. Remove excess EMT as needed.
8. Per DIG-IT Guide, backfill the gap between the
bottom of housing and bottom of hole with
sand for drainage.
Housing
9. Fill and tamp soil to the appropriate height
leaving room for sod, pavers, etc. to be level
with the top of the temporary cover.
10. Pull secondary wiring from remote transformer
to installed housing(s).
7. Connect the conduit to the conduit connectors.
4. Insert (4) pieces of ½” EMT conduit through
the Patented Stability Flange™. Hammer into
substrate until secure.
Leave sufficient clearance to elevate housing
to finished grade.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
PROJECT:
TYPE:
DR2SERIES
Deep Housing - Solid State LED
Remote Transformer Installation Instructions
RELEASE DATE
12-9-16
REFERENCE NUMBER
INS-2179-00
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
Fixture Installation
WIRING DIAGRAM1. Remove temporary cover. 2. Make watertight connections using waterproof
wire connectors (provided) to leads on the
bottom of Patented HydroLock®Barrier Plate
Assembly. See wiring diagram.
3. Wipe O-ring clean of debris on Patented
HydroLock® Barrier Plate. Install Patented
HydroLock® Barrier Plate by aligning
keyholes with dome-topped fasteners
at the bottom of the housing and
while grasping handle; push down on
Patented HydroLock® Barrier Plate until firmly
seated.
4. Turn HydroLock®
Barrier Plate clockwise ¼” to
lock.
Patented HydroLock® Barrier Plate must be
completely seated to ensure proper seal or
water may intrude. This step must be done
as stated or you will void your warranty.
6. Connect optical assembly and faceplate to
Patented HydroLock® Barrier Plate with quick
disconnect.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
PROJECT:
TYPE:
DR2SERIES
Deep Housing - Solid State LED
Remote Transformer Installation Instructions
LINE
COM
GROUND
REMOTE
TRANSFORMER
GROUND
HYDROLOCK PLATE
12V
COM
5. Carefully place O-ring into the groove on top of
housing, keep free of dirt and debris. Dirt and
debris may allow water entry into fixture.
This step must be done as stated or you will
void your warranty.
7. Secure faceplate and optical assembly to
housing with four (4) #10-24 socket head
screws as provided on faceplate with 1/8” Allen
wrench. Hand tighten screws in a cross pattern
to 30 in-lbs. to create proper seal.
Do not use a power tool to install screws. Do
not exceed 40 in-lbs.
LED - For use with 12VAC remote
transformer or magnetic transformers only.
B-K Lighting cannot guarantee performance
with third party manufacturers’ transformers.

Other B-K lighting Lighting Equipment manuals

B-K lighting Precision2 HP2 Series User manual

B-K lighting

B-K lighting Precision2 HP2 Series User manual

B-K lighting ORION User manual

B-K lighting

B-K lighting ORION User manual

B-K lighting YOSEMITE Series User manual

B-K lighting

B-K lighting YOSEMITE Series User manual

B-K lighting PS User manual

B-K lighting

B-K lighting PS User manual

B-K lighting Denali Series User manual

B-K lighting

B-K lighting Denali Series User manual

B-K lighting Union Bollard User manual

B-K lighting

B-K lighting Union Bollard User manual

B-K lighting BACK BOX User manual

B-K lighting

B-K lighting BACK BOX User manual

B-K lighting DENALI User manual

B-K lighting

B-K lighting DENALI User manual

B-K lighting Altair User manual

B-K lighting

B-K lighting Altair User manual

B-K lighting HP2RM User manual

B-K lighting

B-K lighting HP2RM User manual

B-K lighting LT User manual

B-K lighting

B-K lighting LT User manual

B-K lighting ORION User manual

B-K lighting

B-K lighting ORION User manual

B-K lighting SIGN STAR Series User manual

B-K lighting

B-K lighting SIGN STAR Series User manual

B-K lighting INTEGRAL DENALI Series User manual

B-K lighting

B-K lighting INTEGRAL DENALI Series User manual

B-K lighting RE1 User manual

B-K lighting

B-K lighting RE1 User manual

B-K lighting ArtiStar Series User manual

B-K lighting

B-K lighting ArtiStar Series User manual

B-K lighting MB2 User manual

B-K lighting

B-K lighting MB2 User manual

B-K lighting MINI-MICRO DRIVESTAR User manual

B-K lighting

B-K lighting MINI-MICRO DRIVESTAR User manual

B-K lighting ArtiStar Remote ES16 Metal Halide User manual

B-K lighting

B-K lighting ArtiStar Remote ES16 Metal Halide User manual

B-K lighting MICRO NITE STAR User manual

B-K lighting

B-K lighting MICRO NITE STAR User manual

B-K lighting ArtiStar Remote User manual

B-K lighting

B-K lighting ArtiStar Remote User manual

B-K lighting ArtiStar Integral User manual

B-K lighting

B-K lighting ArtiStar Integral User manual

B-K lighting Mini-Micro Series User manual

B-K lighting

B-K lighting Mini-Micro Series User manual

B-K lighting Path Star User manual

B-K lighting

B-K lighting Path Star User manual

Popular Lighting Equipment manuals by other brands

Heitronic 47211 Installation and operating instructions

Heitronic

Heitronic 47211 Installation and operating instructions

Renkforce 1519480 operating instructions

Renkforce

Renkforce 1519480 operating instructions

ProLights EclProfile FW IP user manual

ProLights

ProLights EclProfile FW IP user manual

BoomToneDJ SKYBAR V3 user manual

BoomToneDJ

BoomToneDJ SKYBAR V3 user manual

Chauvet SlimPAR Pro Tri user manual

Chauvet

Chauvet SlimPAR Pro Tri user manual

EuroLite LED Techno Strobe 250 EC user manual

EuroLite

EuroLite LED Techno Strobe 250 EC user manual

Uplus Lighting 250 LED BEAM user manual

Uplus Lighting

Uplus Lighting 250 LED BEAM user manual

Chauvet Colorado 1-Quad Tour user manual

Chauvet

Chauvet Colorado 1-Quad Tour user manual

Intex 52" owner's manual

Intex

Intex 52" owner's manual

Elinchrom Ranger Quadra Service manual

Elinchrom

Elinchrom Ranger Quadra Service manual

FONESTAR BAR-73L instruction manual

FONESTAR

FONESTAR BAR-73L instruction manual

Mercura GYROLED M80 Mounting

Mercura

Mercura GYROLED M80 Mounting

Lena Lighting UV-C Sterilon Hepa user manual

Lena Lighting

Lena Lighting UV-C Sterilon Hepa user manual

Gama Sonic 179010 instruction manual

Gama Sonic

Gama Sonic 179010 instruction manual

Lightronics FXLD548C4O owner's manual

Lightronics

Lightronics FXLD548C4O owner's manual

EuroLite PAR-64 Profi Spot user manual

EuroLite

EuroLite PAR-64 Profi Spot user manual

Skytron STELLAR LFS Series owner's manual

Skytron

Skytron STELLAR LFS Series owner's manual

Commercial Electric HPLA11CWB user guide

Commercial Electric

Commercial Electric HPLA11CWB user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.