TOOLS
NEEDED:
3/32”, 1/8” & 7/64” Allen Wrench
Waterproof Wire Connectors
Data Cable (RE3 Option Only)
Union Bollard
Installation Instructions
CONCRETE INSTALLATION ONLY
RE1 Option - GFI Machined
Aluminum Housing Anchor Kit
RE2 Option - GFI & USB
RE3 Option - RJ45 Jack
(Optional)
Cover with Captive
Tamper Resistant
Screw
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION
INSTRUCTIONS
RELEASE DATE
02/22/2022
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR
SELL ANYTHING IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
REFERENCE NUMBER
INS-2846-00
• Product must be installed by a qualified person in a manner
consistent with its intended use and in compliance with the
National Electrical Code, Canadian Electrical Code, and all
Local and Provincial Codes.
• Follow product label information and instructions.
• Qualified Personnel must perform all servicing or relamping
of this product.
• Before wiring to power supply and during servicing or
relamping, turn off power at fuse or circuit breaker before
service.
• The use of accessory equipment not recommended by the
manufacturer or installed contrary to instructions may cause
an unsafe condition. The use of damaged components may
cause an unsafe condition and void product warranty.
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL
SAFETY AND INSTALLATION INSTRUCTIONS
• Do not block light emanating from product in whole or
part, as this may cause an unsafe condition.
• Never operate the fixture with missing or damaged lens.
Lens must be cleaned on regular basis.
• Entire fixture may become extremely hot. Do not touch hot
lens or fixture body. Do not touch the lamp at any time.
Use a clean, dry, soft cloth to handle the lamp. Oil from
skin may damage the lamp and cause it to rupture.
• Replace lamp only with correct wattage and type of lamp
marked on fixture label.
• All gaskets, o-rings and sealing surfaces must be kept
clean during installation and service; failure to do this may
cause an unsafe condition and void product warranty.
· Suitable for wet locations
IMPORTANT LISTINGS AND CERTIFICATIONS
INSTRUCTIONS PERTAINING TO
A RISK OF FIRE, OR INJURY
TO PERSONS IMPORTANT
SAFETY INSTRUCTIONS
Lighted fixture is HOT!
WARNING - To reduce the risk of
FIRE OR INJURY TO PERSONS:
Turn off/unplug and allow to cool before
replacing lamp/LED. Fixture gets HOT quickly!
Contact only switch/plug when turning on.
Do not touch hot lens, guard, or enclosure.
Keep fixture away from materials that may burn.
Do not operate the luminaire fitting with a missing or
damaged shield. Do not touch the source at any time.
Use a soft cloth or gloves. Oil from skin may cause
damage.
SAVE THESE INSTRUCTIONS
Proper soil preparation is recommended before installation. See the DIG-IT guide at www.bklighting.com/collaterals/install/digit.
pdf for more information.
Warning High Voltage
Union Bollard
Installation Instructions
3. Install anchor plate and bolt assembly flush
with the finished grade.
1 1/2”
1. Adjusted anchor bolts to project at least 1-1/2”
using the four (4) 1/4-20 nuts to the top of the
plate. The four (4) nuts can be left in place
while concrete is poured.
4. With the conduits in place and the anchor
plate properly positioned, secured and leveled,
concrete may be poured.
2. Run conduit inside of the anchor plate center
hole prior to pouring concrete.
Union Anchor Kit Installation
5. The fixture may be installed by removing the
four (4) 1/4-20 nuts and re-using them to
secure the fixture mounting base assembly.
Trim conduit as needed.
Soil Prep
Conduit
trench
B. Dig hole 13” wide and 6” deep.
Conduit
Trench
Excavate for
anchor bolts
C. Prep soil according to DIG-IT Guide.A. Determine Soil Type by referencing DIG-IT
Guide. Prep soil according to DIG-IT Guide.
Finished Grade
RELEASED DATE
02/22/2022
REFERENCE NUMBER
INS-2846-00
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
Union Bollard
Installation Instructions
1. Remove 1/4-20 nuts from installed Union
anchor kit with a socket. Keep the hardware
to reuse in the next step.
2. Line up then place base over installed 1/4-20
nuts.
3. Secure to anchor bolts with the 1/4-20 nuts
and lockwashers provided with the Union
anchor kit using a socket.
Base & Tenon Installation
4. Seal as per NEC with waterproof silicone
sealant (not included).
If the fixture has a receptacle.
7. Secure receptacle cover by tightening #6-32
set screw using a 7/64” allen wrench.
6. Attach receptacle to installed anchor base with
four (4) #10-32 stainless steel countersunk
screws at the base using a 1/8” allen wrench.
5. Pull primary branch circuit wiring and any
additional dimming controls or other wiring
necessary for installation. Attach ground from
branch circuit to ground lead on the anchor
base. Place connectors inside of the housing
(Please refer to page 4 for wiring diagram).
RELEASED DATE
02/22/2022
REFERENCE NUMBER
INS-2846-00
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
Union Bollard
Installation Instructions
HOT
NEUTRAL
GROUND
RECEPTACLE
HOT
NEUTRAL
GROUND
- DIM
+ DIM
FIXTURE
HOT
NEUTRAL
GROUND
FIXTURE
WIRING DIAGRAM
Pull branch circuit wiring. Make watertight
connections from primary branch circuit to
pre-wired 12ga solid wire receptacle leads
using waterproof wire connectors. Connect
incoming ground and ground from receptacle
to ground wire on base. See wiring diagram.
WIRING DIAGRAM - 0-10
Pull branch circuit wiring. Make watertight
connections from primary branch circuit to
pre-wired 16/5 round jacketed fixture head
leads using waterproof wire connectors.
Connect incoming ground and ground from
receptacle to ground wire on base. See wiring
diagram.
WIRING DIAGRAM - INC
Pull branch circuit wiring. Make watertight
connections from primary branch circuit to
pre-wired 16/3 round jacketed fixture head
leads using waterproof wire connectors.
Connect incoming ground and ground from
receptacle to ground wire on base. See wiring
diagram.
RECEPTACLE INSTALLATION DIAGRAM
FIXTURE INSTALLATION DIAGRAM
RELEASED DATE
02/22/2022
REFERENCE NUMBER
INS-2846-00
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
3. Secure receptacle cover by tightening #6-32
set screw using a 7/64” allen wrench.
Union Bollard
Installation Instructions
DATA Receptacle
RJ45
WIRING DIAGRAM 5. Place connection(s) and/or cable inside
receptacle.
4. Place connections into bollard. Attach
inner bracket with RJ45 jack with two (2)
#6-32 screws with a 7/64” allen wrench.
INSTALLATION OF RECEPTACLE (RE3 Option)
2. Loosen two (2) #6-32 screws with a 7/64”
allen wrench to remove inner bracket with
RJ45 jack.
3. Connect incoming data cable (by others)
to RJ45 jack as per installation plan. Follow
manufacturer’s instructions as per cable and
method of connection to RJ45 jack (cable and
connections required by others). See wiring
diagram.
1. Open receptacle cover. Receptacle cover has
#6-32 screw for use with a 7/64” allen wrench.
2. Attach receptacle to installed anchor base
with (4) #10-32 stainless steel countersunk
screws at the base using a 1/8” allen wrench.
1. Attach ground from branch circuit to screw on
anchor base. Place connectors inside receptacle.
INSTALLATION OF RECEPTACLE (RE1 & RE2 Option)
RELEASED DATE
02/22/2022
REFERENCE NUMBER
INS-2846-00
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
6. Attach in-use receptacle to installed anchor
base and plate with (4) #10-32 stainless steel cap
screws at the base using a 1/8” allen wrench.
7. Receptacle cover has captive #6-32 screw.
Secure receptacle by tightening captive
#6-32 set screw using a 7/64” allen wrench.
Union Bollard
Installation Instructions
RELEASED DATE
02/22/2022
REFERENCE NUMBER
INS-2846-00
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS

Other B-K lighting Lighting Equipment manuals

B-K lighting SQUARE ADJUSTABLE WELL STAR User manual

B-K lighting

B-K lighting SQUARE ADJUSTABLE WELL STAR User manual

B-K lighting Mini-Micro Series User manual

B-K lighting

B-K lighting Mini-Micro Series User manual

B-K lighting MB2 User manual

B-K lighting

B-K lighting MB2 User manual

B-K lighting Path Star User manual

B-K lighting

B-K lighting Path Star User manual

B-K lighting ORION User manual

B-K lighting

B-K lighting ORION User manual

B-K lighting CORE DRILL User manual

B-K lighting

B-K lighting CORE DRILL User manual

B-K lighting INTEGRAL DENALI Series User manual

B-K lighting

B-K lighting INTEGRAL DENALI Series User manual

B-K lighting Precision2 HP2 Series User manual

B-K lighting

B-K lighting Precision2 HP2 Series User manual

B-K lighting ArtiStar Remote User manual

B-K lighting

B-K lighting ArtiStar Remote User manual

B-K lighting DENALI User manual

B-K lighting

B-K lighting DENALI User manual

B-K lighting LT User manual

B-K lighting

B-K lighting LT User manual

B-K lighting ArtiStar Integral User manual

B-K lighting

B-K lighting ArtiStar Integral User manual

B-K lighting PRECISION2 CO2 Series User manual

B-K lighting

B-K lighting PRECISION2 CO2 Series User manual

B-K lighting ORION User manual

B-K lighting

B-K lighting ORION User manual

B-K lighting Nite Star User manual

B-K lighting

B-K lighting Nite Star User manual

B-K lighting TETON User manual

B-K lighting

B-K lighting TETON User manual

B-K lighting RE1 User manual

B-K lighting

B-K lighting RE1 User manual

B-K lighting Union Bollard User manual

B-K lighting

B-K lighting Union Bollard User manual

B-K lighting SIGN STAR Series User manual

B-K lighting

B-K lighting SIGN STAR Series User manual

B-K lighting Precision2 HP2 Series User manual

B-K lighting

B-K lighting Precision2 HP2 Series User manual

B-K lighting SS User manual

B-K lighting

B-K lighting SS User manual

B-K lighting BKSSL Precision2 DR2 Series User manual

B-K lighting

B-K lighting BKSSL Precision2 DR2 Series User manual

B-K lighting ArtiStar Series User manual

B-K lighting

B-K lighting ArtiStar Series User manual

B-K lighting YOSEMITE Series User manual

B-K lighting

B-K lighting YOSEMITE Series User manual

Popular Lighting Equipment manuals by other brands

Brighter Pixel Strobe user manual

Brighter

Brighter Pixel Strobe user manual

Sky FLUVAL AQUASKY LED instruction manual

Sky

Sky FLUVAL AQUASKY LED instruction manual

Lanta Aurora 12T-v2 Owner's handbook

Lanta

Lanta Aurora 12T-v2 Owner's handbook

Chauvet COREbar user manual

Chauvet

Chauvet COREbar user manual

SM International KING SPOT 250 user guide

SM International

SM International KING SPOT 250 user guide

Clevertronics L10 Cleverfit Pro Installation & maintenance instructions

Clevertronics

Clevertronics L10 Cleverfit Pro Installation & maintenance instructions

MOFLASH SIGNALLING X201 Series Installation & technical manual

MOFLASH SIGNALLING

MOFLASH SIGNALLING X201 Series Installation & technical manual

Lightolier LP-19 Specification sheet

Lightolier

Lightolier LP-19 Specification sheet

JUNO RCLF11 installation instructions

JUNO

JUNO RCLF11 installation instructions

Insignia NS-DCLR32X5 Quick setup guide

Insignia

Insignia NS-DCLR32X5 Quick setup guide

Conrad 57 43 83 operating instructions

Conrad

Conrad 57 43 83 operating instructions

ECLAIR ARMLED PLUS user manual

ECLAIR

ECLAIR ARMLED PLUS user manual

Robus R8MLEDTS-01 instruction manual

Robus

Robus R8MLEDTS-01 instruction manual

Vision & Control SLF-100-W5K7-P-24V Instructions for use

Vision & Control

Vision & Control SLF-100-W5K7-P-24V Instructions for use

Task Lighting T-C-RGB180 installation guide

Task Lighting

Task Lighting T-C-RGB180 installation guide

ETD Chameleon 6 Mounting guide

ETD

ETD Chameleon 6 Mounting guide

Chauvet CH-215 user guide

Chauvet

Chauvet CH-215 user guide

HEPER DRAGO 8 LED LB6048.910-EN manual

HEPER

HEPER DRAGO 8 LED LB6048.910-EN manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.