manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. B-K lighting
  6. •
  7. Lighting Equipment
  8. •
  9. B-K lighting LT User manual

B-K lighting LT User manual

Pea gravel or sand
Finished grade
Pea gravel or sand
Concrete or Soil
Finished grade
LINE 12V
FIXTURE
COM
Remote
Transformer
(by others)
COM
Finished grade Optional
Stability Flange
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY
DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
TOOLS
NEEDED:
By Others
5/64” Allen Wrench
Phillips Screwdriver
Waterproof Wire Connectors
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY
DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
Pea gravel or sand
Finished grade
Pea gravel or sand
Concrete or Soil
Finished grade
LINE 12V
FIXTURE
COM
Remote
Transformer
(by others)
COM
Finished grade Optional
Stability Flange
This set of instructions works for:
LT - Litestick™
LT-L - Litestick™ Style L
LT-T - Litestick™ Style T
Pea gravel or sand
Finished grade
Pea gravel or sand
Concrete or Soil
Finished grade
LINE 12V
FIXTURE
COM
Remote
Transformer
(by others)
COM
Finished grade Optional
Stability Flange
LT-L
TOOLS
NEEDED:
By Others
18 Gauge Wire
Optional Stability
Flange
Power Pipe™
Adjustable
Stem
Fixed
Stem
DATE
11-30-16
REFERENCE NUMBER
INS001109
Warning Flammable Hot Surface
LT
• Product must be installed by a qualified person in a manner
consistent with its intended use and in compliance with the
National Electrical Code, Canadian Electrical Code, and all Local
and Provincial Codes.
• Follow product label information and instructions.
• Qualified Personnel must perform all servicing or relamping of
this product.
• Before wiring to power supply and during servicing or relamping,
turn off power at fuse or circuit breaker before service.
• The use of accessory equipment not recommended by the
manufacturer or installed contrary to instructions may cause an
unsafe condition. The use of damaged components may cause
an unsafe condition and void product warranty.
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY
AND INSTALLATION INSTRUCTIONS
• Do not block light emanating from product in whole or part,
as this may cause an unsafe condition.
• Never operate the fixture with missing or damaged lens.
Lens must be cleaned on regular basis.
• Entire fixture may become extremely hot. Do not touch hot
lens or fixture body. Do not touch the lamp at any time. Use
a clean, dry, soft cloth to handle the lamp. Oil from skin may
damage the lamp and cause it to rupture.
• Replace lamp only with correct wattage and type of lamp
marked on fixture label.
• All gaskets, o-rings and sealing surfaces must be kept clean
during installation and service; failure to do this may cause an
unsafe condition and void product warranty.
INSTRUCTIONS PERTAINING TO
A RISK OF FIRE, OR INJURY TO
PERSONS IMPORTANT SAFETY
INSTRUCTIONS
Lighted lamp is HOT!
WARNING - To reduce the risk of FIRE OR INJURY TO PERSONS:
Turn off/unplug and allow to cool before replacing lamp.
Lamp gets HOT quickly! Contact only switch/plug when turning on.
Do not touch hot lens, guard, or enclosure
(see diagram/picture).
Keep lamp away from materials that may burn.
Do no touch the lamp at any time. Use a soft cloth.
Oil from skin may damage lamp.
Do not operate the luminaire fitting with a missing or damaged shield.
SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS
· SUITABLE FOR WET LOCATIONS · SUITABLE FOR IN-GROUND RECESSED INSTALLATION
IMPORTANT LISTINGS AND CERTIFICATIONS
Fixed Stem
with
T - housing
option
LT-T
& Low Voltage Halogen LT™/ LT-L™/ LT-T™
Installation Instructions
High Voltage
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING
IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
& Low Voltage Halogen LT™/ LT-L™/ LT-T™
Installation Instructions
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING
IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
Pea gravel or sand
Finished grade
Pea gravel or sand
Concrete or Soil
Finished grade
LINE 12V
FIXTURE
COM
Remote
Transformer
(by others)
COM
Finished grade Optional
Stability Flange
DATE
11-30-16
REFERENCE NUMBER
INS001109
Pea gravel or sand
Finished grade
Pea gravel or sand
Concrete or Soil
Finished grade
LINE 12V
FIXTURE
COM
Remote
Transformer
(by others)
COM
Finished grade Optional
Stability Flange
4. Place Power Pipe™ in hole.
Pea gravel or sand
Finished grade
Pea gravel or sand
Concrete or Soil
Finished grade
LINE 12V
FIXTURE
COM
Remote
Transformer
(by others)
COM
Finished grade Optional
Stability Flange
2. Slide optional Stability Flange onto Power
Pipe™. Use optional Stability Flange to aid in
installation of Power Pipe™.
1. Excavate trench according to designed lighting
plan. Dig hole a minimum of 24” deep and 10”
wide to accommodate Power Pipe™ at desired
fixture locations.
Power Pipe™ Installation
Pea gravel or sand
Finished grade
Pea gravel or sand
Concrete or Soil
Finished grade
LINE 12V
FIXTURE
COM
Remote
Transformer
(by others)
COM
Finished grade Optional
Stability Flange
5. Back fill with pea gravel or sand as required.
Pea gravel or sand
Finished grade
Pea gravel or sand
Concrete or Soil
Finished grade
LINE 12V
FIXTURE
COM
Remote
Transformer
(by others)
COM
Finished grade Optional
Stability Flange
6. Backfill with soil or prepare for concrete pour.
Label on Power Pipe™ indicates installation
depth with finished grade.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
3. Pull low voltage wiring from remote transformer
(By Others) to Power Pipe™. Allow for additional
cable to make connections to fixture lead and
future service.
Pea gravel or sand
Finished grade
Pea gravel or sand
Concrete or Soil
Finished grade
LINE 12V
FIXTURE
COM
Remote
Transformer
(by others)
COM
Finished grade Optional
Stability Flange
2. Insert additional wires and connectors into
Power Pipe. Place fixture on Power Pipe™.
3. Tighten three (3) #8-32 stainless steel round
head Phillips screws on cap to secure to
installed Power Pipe™.
Pea gravel or sand
Finished grade
Pea gravel or sand
Concrete or Soil
Finished grade
LINE 12V
FIXTURE
COM
Remote
Transformer
(by others)
COM
Finished grade Optional
Stability Flange
1. Make watertight connections from remote
12V transformer to fixture leads using
waterproof wire connectors (By Others).
Adjustable stem includes 60” of addtional
18/2 direct burial low voltage cable.
4. Slide stem up or down to desired height. Delrin
bushing holds stem in position. Tighten three
(3) #10 stainless steel set screws using a 3/32”
Allen wrench to lock mounting height in place.
Unused stem length remains hidden inside
Power Pipe™ to accommodate future landscape
growth.
Pea gravel or sand
Finished grade
Pea gravel or sand
Concrete or Soil
Finished grade
LINE 12V
FIXTURE
COM
Remote
Transformer
(by others)
COM
Finished grade Optional
Stability Flange
Fixed and Adjustable Stem Fixture Installation
For Adjustable Stem Only
LED - For use with 12VAC remote
transformer or magnetic transformers
only. B-K Lighting cannot guarantee
performance with third party manufacturers’
transformers.
Low Voltage - For use with 12VAC remote
transformer.
NOTE: Leave sufficient wire length in the
fixture housing for future service. Do not cut
PVC.
& Low Voltage Halogen LT™/ LT-L™/ LT-T™
Installation Instructions
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
Pea gravel or sand
Finished grade
Pea gravel or sand
Concrete or Soil
Finished grade
LINE 12V
FIXTURE
COM
Remote
Transformer
(by others)
COM
Finished grade Optional
Stability Flange
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
Pea gravel or sand
Finished grade
Pea gravel or sand
Concrete or Soil
Finished grade
LINE 12V
FIXTURE
COM
Remote
Transformer
(by others)
COM
Finished grade Optional
Stability Flange
Pea gravel or sand
Finished grade
Pea gravel or sand
Concrete or Soil
Finished grade
LINE 12V
FIXTURE
COM
Remote
Transformer
(by others)
COM
Finished grade Optional
Stability Flange
1. Loosen #8-32 stainless steel set screw on cap
using a 5/64” Allen wrench and remove.
THIS PRODUCT IS AVAILABLE WITH A FACTORY INSTALLED LED OR HALOGEN LAMP.
Halogen Lamp or LED Installation - If Required
DATE
11-30-16
REFERENCE NUMBER
INS001109
3. Place cap on fixture and tighten set screw.
Tighten screw to 1/2 inch pounds. Top of
screw should sit flush with fixture cap.
Warning: Do not over tighten set screw.
Doing so will compromise O Ring seal and
will void warranty.
2. Install lamp. For BKSSL: Pull the heat sink
from the body to expose the LED board
and Driver components. Utilize quick
disconnects to change modular LED and
driver components. Re-install the heat sink
into body.
CAUTION…follow lamp manufacturers instructions. Do
not touch lamp glass with bare skin. High temperature
of lamp will cause skin oil to damage glass. Clean lamps
with alcohol, if touched.
Halogen BKSSL
Integral Transformer
1. Pull branch circuit wires necessary for installation
(By Others) through Power Pipe™. Use waterproof
wire connectors (By Others) to connect transformer
primary leads to branch circuit wires. Connect
incoming ground to ground wire provided in
fixture body. See wiring diagram.
120V 12V
Fixture
COM
Remote
Transformer
COM
120V 12V
Fixture
COM
GROUND
Integral
Transformer
COM
GROUND IN HOUSING
Pea gravel or sand
Finished grade
Pea gravel or sand
Concrete
Finished grade
Finished grade Optional
Stability Flange
120V 12V
Fixture
COM
GROUND
Integral
Transformer
COM
GROUND IN HOUSING
2. Insert wires, connectors and/or transformer into
fixture base and attach to Power Pipe™. Tighten
three (3) #8-32 stainless steel round head Phillips
screws at base to secure.
120V 12V
Fixture
COM
Remote
Transformer
COM
120V 12V
Fixture
COM
GROUND
Integral
Transformer
COM
GROUND IN HOUSING
Pea gravel or sand
Finished grade
Pea gravel or sand
Concrete
Finished grade
Finished grade Optional
Stability Flange
120V 12V
Fixture
COM
GROUND
Integral
Transformer
COM
GROUND IN HOUSING
120V 12V
Fixture
COM
Remote
Transformer
COM
120V 12V
Fixture
COM
GROUND
Integral
Transformer
COM
GROUND IN HOUSING
Pea gravel or sand
Finished grade
Pea gravel or sand
Concrete
Finished grade
Finished grade Optional
Stability Flange
120V 12V
Fixture
COM
GROUND
Integral
Transformer
COM
GROUND IN HOUSING
WIRING DIAGRAM
Integral
Transformer
Fixed Stem And T-Housing Option Fixture Installation
TRANSFORMER HOUSING MUST BE INSTALLED ABOVE GRADE. POWER PIPE™ IS LABELED AT GRADE LEVEL.
TRANSFORMER HOUSING INSTALLED BELOW GRADE WILL VOID WARRANTY

This manual suits for next models

2

Other B-K lighting Lighting Equipment manuals

B-K lighting Precision2 HP2 Series User manual

B-K lighting

B-K lighting Precision2 HP2 Series User manual

B-K lighting Precision2 HP2 Series User manual

B-K lighting

B-K lighting Precision2 HP2 Series User manual

B-K lighting ArtiStar Series User manual

B-K lighting

B-K lighting ArtiStar Series User manual

B-K lighting SS User manual

B-K lighting

B-K lighting SS User manual

B-K lighting CORE DRILL User manual

B-K lighting

B-K lighting CORE DRILL User manual

B-K lighting HP2RM User manual

B-K lighting

B-K lighting HP2RM User manual

B-K lighting Nite Star User manual

B-K lighting

B-K lighting Nite Star User manual

B-K lighting Path Star User manual

B-K lighting

B-K lighting Path Star User manual

B-K lighting BACK BOX User manual

B-K lighting

B-K lighting BACK BOX User manual

B-K lighting BKSSL Precision2 DR2 Series User manual

B-K lighting

B-K lighting BKSSL Precision2 DR2 Series User manual

B-K lighting ORION User manual

B-K lighting

B-K lighting ORION User manual

B-K lighting Denali Series User manual

B-K lighting

B-K lighting Denali Series User manual

B-K lighting SQUARE ADJUSTABLE WELL STAR User manual

B-K lighting

B-K lighting SQUARE ADJUSTABLE WELL STAR User manual

B-K lighting MINI-MICRO DRIVESTAR User manual

B-K lighting

B-K lighting MINI-MICRO DRIVESTAR User manual

B-K lighting MICRO NITE STAR User manual

B-K lighting

B-K lighting MICRO NITE STAR User manual

B-K lighting PRECISION2 CO2 Series User manual

B-K lighting

B-K lighting PRECISION2 CO2 Series User manual

B-K lighting Union Bollard User manual

B-K lighting

B-K lighting Union Bollard User manual

B-K lighting DENALI User manual

B-K lighting

B-K lighting DENALI User manual

B-K lighting TETON User manual

B-K lighting

B-K lighting TETON User manual

B-K lighting YOSEMITE Series User manual

B-K lighting

B-K lighting YOSEMITE Series User manual

B-K lighting Mini-Micro Series User manual

B-K lighting

B-K lighting Mini-Micro Series User manual

B-K lighting INTEGRAL DENALI Series User manual

B-K lighting

B-K lighting INTEGRAL DENALI Series User manual

B-K lighting ORION User manual

B-K lighting

B-K lighting ORION User manual

B-K lighting MINI-MICRO RECESSED UPLIGHT User manual

B-K lighting

B-K lighting MINI-MICRO RECESSED UPLIGHT User manual

Popular Lighting Equipment manuals by other brands

Generac Power Systems RS801 installation manual

Generac Power Systems

Generac Power Systems RS801 installation manual

Monacor AL-16/ RT operating instructions

Monacor

Monacor AL-16/ RT operating instructions

Omron F3SG-SR Series instruction sheet

Omron

Omron F3SG-SR Series instruction sheet

LIVARNO LG-9483 Instructions for use

LIVARNO

LIVARNO LG-9483 Instructions for use

Paramount Fitness Paraskim V Owner's manual and installation guide

Paramount Fitness

Paramount Fitness Paraskim V Owner's manual and installation guide

Unilamp AGAR Prismatic installation manual

Unilamp

Unilamp AGAR Prismatic installation manual

Leding Spark Wash 4C user manual

Leding

Leding Spark Wash 4C user manual

EuroLite LED KRF-144 user manual

EuroLite

EuroLite LED KRF-144 user manual

IMRELAX IM-MH3715 user manual

IMRELAX

IMRELAX IM-MH3715 user manual

Moda Light MODA MINI GRAZE INT COLOR 0-10V installation instructions

Moda Light

Moda Light MODA MINI GRAZE INT COLOR 0-10V installation instructions

Elation ELED Fresnel 150 User instructions

Elation

Elation ELED Fresnel 150 User instructions

S.R.Smith ROGUE GRAND RAPIDS owner's manual

S.R.Smith

S.R.Smith ROGUE GRAND RAPIDS owner's manual

Portfolio HZA1601L-4 manual

Portfolio

Portfolio HZA1601L-4 manual

Eglo BOYAL 99457A instructions

Eglo

Eglo BOYAL 99457A instructions

Laserworld CS-300G DMX user manual

Laserworld

Laserworld CS-300G DMX user manual

Oase 45387 operating instructions

Oase

Oase 45387 operating instructions

Philips GreenPower LED production module DR/B Quick installation guide

Philips

Philips GreenPower LED production module DR/B Quick installation guide

Index Z0865 LED product manual

Index

Index Z0865 LED product manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.