**IMPORTANT** Photo sensor(s) MUST be properly installed (see p.19-20)
BEFORE the AUTOSET procedure!
**IMPORTANT** OPEN and CLOSE limit switches MUST be properly adjusted
(see p.9) BEFORE the AUTOSET procedure!
Launch an AUTOSET operation by going to the relevant menu. As soon as you press the OK button, the “.... .... ....” message is displayed, and the
control unit commands the device to perform a full cycle (opening followed by closing), during which the minimum torque value required to move the
leaf is set automatically. The number of cycles required for the AUTOSET function can range from 1 to 3. During this stage, it is important to avoid
breaking the photocells’ beams and not to use the START and STOP commands or the display. Once this operation is complete, the control unit will
have automatically set the optimum torque values. Check them and, where necessary, edit them as described
in the programming section.
During the AUTOSET stage, it is
important to avoid breaking the
photocells’ beams and not to use
the START and STOP commands or