manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. BFT
  6. •
  7. Gate Opener
  8. •
  9. BFT KUSTOS ULTRA BT User manual

BFT KUSTOS ULTRA BT User manual

Other manuals for KUSTOS ULTRA BT

1

Other BFT Gate Opener manuals

BFT P7 User manual

BFT

BFT P7 User manual

BFT DEIMOS BT KIT UL User manual

BFT

BFT DEIMOS BT KIT UL User manual

BFT EBB KIT BL-LARGE User manual

BFT

BFT EBB KIT BL-LARGE User manual

BFT PHOBOS N User manual

BFT

BFT PHOBOS N User manual

BFT P7 User manual

BFT

BFT P7 User manual

BFT CELLULA 180 User manual

BFT

BFT CELLULA 180 User manual

BFT ELI-250 User manual

BFT

BFT ELI-250 User manual

BFT PHOBOS N BT User manual

BFT

BFT PHOBOS N BT User manual

BFT ICARO User manual

BFT

BFT ICARO User manual

BFT LUX BT 2B User manual

BFT

BFT LUX BT 2B User manual

BFT D113745-00001 User manual

BFT

BFT D113745-00001 User manual

BFT OBERON Manual

BFT

BFT OBERON Manual

BFT MAXIMA 30 User manual

BFT

BFT MAXIMA 30 User manual

BFT P7 User manual

BFT

BFT P7 User manual

BFT ELI 250 BT User manual

BFT

BFT ELI 250 BT User manual

BFT DEIMOS BT A 600 User manual

BFT

BFT DEIMOS BT A 600 User manual

BFT KUSTOS ULTRA BT A25 User manual

BFT

BFT KUSTOS ULTRA BT A25 User manual

BFT IGEA User manual

BFT

BFT IGEA User manual

BFT P7 User manual

BFT

BFT P7 User manual

BFT PHOBOS N User manual

BFT

BFT PHOBOS N User manual

BFT Cell Box Switch Instruction Manual

BFT

BFT Cell Box Switch Instruction Manual

BFT P7 - P 4.5 User manual

BFT

BFT P7 - P 4.5 User manual

BFT CLONIX1-2 User manual

BFT

BFT CLONIX1-2 User manual

BFT AKTA A30 User manual

BFT

BFT AKTA A30 User manual

Popular Gate Opener manuals by other brands

Nortek Security & Control Mighty Mule HD272 installation manual

Nortek Security & Control

Nortek Security & Control Mighty Mule HD272 installation manual

tousek TURN 10 Installation and operating instructions

tousek

tousek TURN 10 Installation and operating instructions

SOMFY AXOVIA 220B RTS installation instructions

SOMFY

SOMFY AXOVIA 220B RTS installation instructions

Nice HySecurity CBOX1050 Installation and programming manual

Nice HySecurity

Nice HySecurity CBOX1050 Installation and programming manual

CAME FROG-PM4 installation manual

CAME

CAME FROG-PM4 installation manual

Aprimatic ONDA 500 installation instructions

Aprimatic

Aprimatic ONDA 500 installation instructions

Turnstiles FSW 900 manual

Turnstiles

Turnstiles FSW 900 manual

Erreka BUL BL33 Quick installation and programming guide

Erreka

Erreka BUL BL33 Quick installation and programming guide

Extel VERA quick guide

Extel

Extel VERA quick guide

Beninca R1-2 WBV quick start guide

Beninca

Beninca R1-2 WBV quick start guide

Erreka VULCAN D user manual

Erreka

Erreka VULCAN D user manual

Motorline professional FORT User& installer's manual

Motorline professional

Motorline professional FORT User& installer's manual

Beninca BOB5024 manual

Beninca

Beninca BOB5024 manual

AGA GATEMASTER 900 HD installation manual

AGA

AGA GATEMASTER 900 HD installation manual

Cardin BL Series manual

Cardin

Cardin BL Series manual

Westfalia 85 27 06 instruction manual

Westfalia

Westfalia 85 27 06 instruction manual

Riello Elettronica CARDIN ACE FAST Instruction handbook

Riello Elettronica

Riello Elettronica CARDIN ACE FAST Instruction handbook

Telcoma ARM Instruction handbook

Telcoma

Telcoma ARM Instruction handbook

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1Motor fastening
2
Limit switch adjustment (put motor in gear by moving the panel by hand)
Programming (see reverse)
3
4
Adjust the limit switches 5and the stops 3according to the diagrams, open/closed position.
Once set up, fine-tune the adjustments.
5x0.75 mm²
3x1.5 mm²
230 v
3x1.5 mm²
2x0.75 mm²
3x1.5 mm²
b
a100 110 120
101401801311911621321021711001
110 112 116 119 121 122 116 110 105 102
120 107 110 114 117 120 117 111 106 102
130 103 106 109 113 116 117 113 107 102
140 97 102 105 108 112 115 113 110 103
150 97 101 104 107 110 113 110 104
160 97 100 104 107 109 110 105
170 96 100 103 106 108 105
180 96 100 103 106 107
190 96 99 102 105
200 96 98 101
210 95 98
220 95
130 140 150 160 170 180 190 200 210 220
Z=b-x>60mm
Pa
x
b
S
D
F
2s
kg
C=1190mm
1
2
CLOSE
4
35
6
1
2
OPEN
5
6
A
B
4
3
S
(mm)
KUSTOS ULTRA BT A40
125
kg
(~ 1250 N) 250
kg
(~ 2500 N)
b (mm)
20 130 ÷ 160 170 ÷ 260
30 130 ÷ 170 180 ÷ 260
40 130 ÷ 180 190 ÷ 260
KUSTOS ULTRA BT A40
a
1210 355
Cu Max
120
110
FC1
(open)
80
80
FC2
(close)
a
Cu MAX
KUSTOS ULTRA BT
Cable run
Use normalised black cables
R02V - HO5VVF
For safety warnings, please see complete instruction manual
Product reserved for professionals
FW ≥ v2.12
D812964 04903_01 18-10-17
KUSTOS ULTRA BT
Maximum Power
Maximum Cycle
Motor 1 opens first.
S3 13s-1-13s-1 x30
40 W
pause
90min.
Thalia control board
JP5 JP7
Y #
F2 3,15 AT
F1 1.25 AT(220-230V)
F1 2.5 AT (120V)
ANT
220-230V ~
*
S2
S1
S3
L N 10 11
LN
M1
220-230V ~
*
14 15 20 21 26 27 40 41 42 43 44 45 50 51 52 60 61 62 70 71 72 73 74 75
+
M2
24V
AUX 3
(MAX 24V 1A)
SN 1
SN 2
24V -
24V +
24 VSafe+
COM
IC 1
IC 2
COM
SAFE 1
STOP
FAULT 1
SAFE 2
FAULT 2
-
+
-
NO
NO
NC
NC
NC
JP21
Antenne
Optional
board connector,
Safety devicesCommandsAUXPower supply Motor limit switch
inputs
Accessories
power
supply
40 41 42 43 44 45
SW 1
10 11
M1
14 15
+
M2
-
+
-
SW 2
123
SW 1
M1 +
M1-
123
SW 2
M2 +
M2-
THALIA
1Simplified menu: basic regulations
Click OK Upward/Downward
x1
Motor at stroke centre and in gear:
- apply power
- 1x OK: language appears. 3x - (ENG) + click OK
- select “type” of motor. x - (Kustos) + click OK
- select number of motors (n. mot.). 2x - + click OK
- select direction (direction of opening). Select (int. or ext.) + click OK
- select preset. (Ar: auto closure or Sr: semi-auto closure). Select + click OK
- start autoset with panels at half-travel; they close.
If this is not a closing operation, then press +- simultaneously.
Reconnect the motors in the right direction (motor 1 switch 10&11; motor 2 switch 14&15)
When autoset is finished, the display show OK.
As an option, you can go even further...
4How to perform an open/close test by using the remote control.
3How to programme the remote control
- Access the radio menu
- Select the channel you want (“add start” total opening or “add2ch” for the 2nd channel), then press OK.
Screen display Screen display Screen display
Screen display
hidden button
Ok + key no
release desidered button
Press the 2 top keys
simultaneously (hidden
key), until the screen
displays...
Select the key to be
programmed, with a
single push
1 - I wish to de-activate the photocells while opening: Access the Logic menu, scroll down to screen SAFE 1,
go to 4.
2 - I wish to access automatic closing: Access the logic menu, scroll down to the TCA screen,
go to 1.
3 - I wish to adjust the automatic closing time: Access the Param menu, click OK, and scroll down to
the TCA screen, enter the value and click OK.
4- I wish to activate pedestrian opening: Access the Logic menu; scroll down to screen AUX 3, go
to 1.(then continue programming the 2nd key on your
remote control).
language
Dir
ITA
fra
deu
eng
esp
int
EXT
type eli
2
n. mot.
1
.....
phobos BT A
phobos N
AR
preset
sr
ac
sc
ind
24V
2
1TX1 2
1
RX1
4
5
3
50 51 52
70 72 73
SAFE1= 1 , 3 , 5
24V
2
1TX1 2
1
RX1
4
5
3
50 51
70 72
SAFE1= 0, 2, 4
Wire the THEA photocells.
2b
2a
Wire the DESME photocells.
or