16 en | System overview Plena Voice Alarm System
9922 141 1037x (V2.16) | V0.6 | 2011.09 Installation and Operation manual Bosch Security Systems B.V.
5. Emergency call zone selectors:
Six buttons to select the zones to which the emergency call must be distributed (see
section 7.4 ). Each button has a green and a red LED. The six red LEDs indicate the zones
that are selected for the emergency call. The six green LEDs indicate the zones in which a
business call is running.
6. BGM zone selectors:
Six buttons to select the zones to which the BGM is distributed (see section 7.2 ). Each
button has a green LED and a rotary knob. The six green LEDs indicate the zones to
which BGM is distributed. The six rotary knobs are local volume controls that can be used
to adjust the volume of the BGM in each zone. Each volume control knob has six settings.
7. BGM master volume control:
A rotary knob to set the master volume of the BGM (see section 7.2 ).
8. BGM source selector:
A button to select the BGM source (CD/Tuner or Aux). The selected source is indicated
with a green LED (see section 7.2 ).
9. BGM tone controls:
Two rotary knobs to control the high and low frequencies of the BGM (see section 7.2 ).
10. All call button:
A button to select all zones. This button is only available in the emergency state (see
section 7.4 ).
11. Indicator test button:
A button to test all LEDs on the front panel of the voice alarm controller, and connected
voice alarm routers, remote control panels, remote control extensions and fireman’s
panels. All LEDs are lit as long as the button is pushed (see section 7.5 ).
12. Emergency button:
A push button to put the system in the emergency state (see section7.4 ).
13. Alert message button:
A button to select the alert message. This button is only available in the emergency state
(see section 7.4 ).
14. Alarm message button:
A button to select the default alarm message. This button is only available in the
emergency state (see section 7.4 ).
15. Microphone socket:
A socket to connect the hand-held emergency microphone (see section 5.1.1 ).
16. Bracket:
A bracket for the hand-held emergency microphone that is supplied with the voice alarm
controller.
17. Monitoring speaker:
Built-in monitoring speaker.
18. Zone outputs:
Six zone outputs to connect loudspeakers to the voice alarm controller. Each zone output
consists of two loudspeaker line outputs (see section 5.1.6 ).
19. Override outputs:
Six volume override outputs to override local volume controls in each zone (see section
5.1.7 ).
20. Status outputs:
Three status outputs to send the status of the Plena Voice Alarm System to third party
equipment (see section 5.1.11 ).