Precautions
• Do not touch with bare hands — always wear heat
resistant gloves to touch the probe during
or after cooking.
• Dispose of used batteries promptly and keep the
batteries and thermometer away from children.
• Always read the user manual thoroughly before
operating.
• Avoid subjecting the probe or thermometer
to an open ame on the BBQ.
• Avoid submerging the probe past the junction (where
the probe meets the case) or the case itself. The
junction and/or case are not waterproof.
• Avoid subjecting the probe and/or thermometer
to temperatures over 572°F/300°C.
• Clean the probe and thermometer with warm soapy
water and dry thoroughly after use.
• Avoid cleaning the unit with an abrasive or corrosive
compound, which may scratch the plastic parts and
corrode the electronic circuits.
• Avoid subjecting the thermometer to excessive force,
shock, dust, temperature, direct sunlight or humidity.
This may result in thermometer malfunction, shorter
electronic life span, battery damage and/or distort
parts.
• Avoid tampering with the thermometer’s internal
components, which may cause battery damage and
distort parts.
• Avoid immersing case into water or exposure to
heavy rain. The case is not waterproof.
• Do not use the thermometer in microwave oven.
Specications
Measurement Range: -40 to +572°F/-40 to 300°C
Operating Range: 32~104°F/0~40°C/≤90% RH
Unit of Measure: °F/°C
Resolution: 0.1°F/0.1°C
Accuracy: -40 to +392°F/-40 to +200°C:
±0.7°F/±0.4°C; above
392°F/200°C: ±1.8°F/±1°C
Water Resilience: IP54
Probe Type: Thermocouple Type K
Probe Length: 4.5"/11.5 cm probe
Sensor Diameter: 1.5 mm thin tip
Power: Two 1.5V AAA IEC LR03
alkaline
Dimensions: 1.61 W x 6.34 H x 0.98 D (in)/
4.1 W x 16.1 H x 2.5 D (cm)
Weight: 4.0 oz / 113 g
CAUTION: Avoid keeping the thermometer too close to
objects that continuously generate high heat for long
periods (i.e., hot plate). This can cause the thermometer to
overheat.
CE Note: This device could be sensitive to electrostatic
discharge. If electrostatic discharge or malfunctioning
occurs, please re-install the battery to reset this unit.
USDA SAFE FOOD TEMPERATURES
* Beef, Veal, Lamb – well ...160°F ..71°C
* Beef, Veal, Lamb – medium 145°F ..63°C
* Beef, Veal, Lamb – rare ...140°F ..60°C
Poultry . . . . . . . . . . . . . . . 165°F ..74° C
* Pork/Ham – pre-cooked...145°F ..63°C
Ground Meat...........160°F ..71°C
* 3 minutes rest time
CANDY TEMPERATURE GUIDE
Jelly .............220°F . . . . . . 104°C
Thread .......230–234°F . . 110–112°C
Soft Ball ......234–240°F . . .112–115°C
Firm Ball......244–248°F . . 118–120°C
Hard Ball .....250–266°F . . .121–130°C
Soft Crack ....270–290°F . . .132–143°C
Hard Crack ....300–310°F . . 149–154°C
Caramelize ....316–338°F . . .15 8 –170° C
HIGH ALTITUDE ADJUSTMENT
FOR CANDY-MAKING
STAGE 2,000 feet 5,000 feet 7,500 feet
Soft Ball 230–236°F 224–230°F 219–225°F
Firm Ball 238–244°F 232–238°F 227–233°F
Hard Ball 246–264°F 240–258°F 235–253°F
Soft Crack 266–286°F 260–286°F 255–275°F
Hard Crack
296–306°F 290–300°F 285–295°F