Crow RUNNER-8 Operating instructions

1
Runner Series
8/16 ZONE WIRELESS AND WIRED ALARM CONTROL PANEL
VERSION 908.2 AUSTRALIA
COVERS:RUNNER-8, RUNNER-16, RUNNER-PLUS
CONDENSED PROGRAMMING (TECHNICIAN’S)GUIDE
USER PROGRAMMING
ADDRESS DESCRIPTION DEFAULT NEW
P1E 1-100E USER CODES 1 TO100. Codescan be up to 6 digits.User 1 (Master
Code) =123
U1 =123
P2E 1-100E USER TYPE - Code/Radio/Access tag-Card
0 =Keypad Code User (PIN)
1 =Radio User (Users21-100 only)
2 =Access Tag/Card User
3 =Both Code and Access Tag/Card User (Tag +PIN)
4 =Either Code or Access Tag/Card User (Tag or PIN)
U 1-40 =4
U 41-100 =1
P3E 1-100E USER AREAASSIGNMENT. 1= Area A, 2 =Area B U 1-100 =1
P4E 1-100E USER CODEACCESS OPTIONS
User 1-40 =1,2,3,4,8
User 41,45,49,53,57, =1,3,4,8
User 42,46,50,54,58 =2,4,8
User 43,47,51,55,59 =8,(DelayPanic – see P8E)
User 44,48,52,56,60 =8,(O/P-4 control – see P12E 4E, P13 4E, P14E
4E)
User 61,66,71,76,81,86,91,96 =3,4,8
User 62,67,72,77,82,87,92,97 =1,8
User 63,68,73,78,83,88,93,98 =2,8
User 64,69,74,79,84,89,94,99 =8, (O/P-4 control–see P12E 4E,P13
4E, P14E 4E)
User 65,70,75,80,85,90,95,100 =8,(DelayPanic– see P8E)
1 =Code can Arm Area
2 =Code can arm Stay Mode
3 =Code can DisarmArea
4 =Code can disarm Stay Mode
5 =Code isa SecurityGuard Code
6 =Code will Arm LatchkeyMode
7 =CallDivertCode
8 =User can ViewEvent Memory

2
USER PROGRAMMING– Cont.
ADDRESS DESCRIPTION DEFAULT NEW
P5E 1-100E USER CODEACCESS OPTIONS
1 =User can Change their Code (Defaultfor users 2-100)
2 =User can Change All Codes
3 =User can AllowAccess to Installer Mode/Edit allCodes
4 =User can Change Telephone Numbers
5 =User can Change the Clock
6 =User can Change DTMF CommandCodes
7 =User can Learn NewRadio Devices
8 =User can Force a Download to Call-backNumber
U1 =
2,3,4,5,6,7,8
U2-100 =1
P7E 21-100E RADIO USER TYPE (Applies toUsers 21-100 Only)
0 =Generic(generalPendant Type)
1 =CrowFreewave Pendant
2 =Ness Pendant
U21 –100 =1
P8E 21-100E RADIO USER PRIVILEGES
User 21-42,45,46,49,50,53,54,57,58,61,65,66,70,71,
75,76,80,81,85,86,90,91,95,96,100 = 1
User 43,47,51,55,59,65,70,75,80,85,90,95,100 = 3
1 =Pendant Can DisarmatAll Times
2 =Pendant CausesImmediatePanic
3 =Pendant CausesDelayed Panic( 1.5Sec)
4 =Pendant onlyworksduring entry delay
5 =ThisUser isa dedicated Duress Code
P9E 1-100E TIMEZONEASSIGNED TOAUSER
1 =TimeZone 1 ……….. 8 = TimeZone 8
U 1-100 =0
P10E 1-100E USER TO KEYPAD ASSIGNMENT
1 =Can operate @ K/pad 1 ....8 =Can operate @K/pad 8
U 1-100 =All
Keypads
P11E 21-100E RADIO PENDANTPANIC BEEPS TOKEYPAD
1 =Radio Panic beepsK/pad 1 ...8 =RadioPanicbeepsK/pad 8
U 1-100 =All
Keypads
P12E 1-100E USERS TO OUTPUT MASK
Users44,48,52,56,60,64,69,74,79,84,89,94,99 = 4
1 =User Mapped to O/P 1 …. 8=User Mapped to O/P 8
P13E 1-100E USERS CANTURN ONAN OUTPUT
Users44,48,52,56,60,64,69,74,79,84,89,94,99 = 4
1 =User can turn ONO/P 1….8 =User can turn ON O/P8
P14E 1-100E USERS CANTURN OFFAN OUTPUT
Users44,48,52,56,60,64,69,74,79,84,89,94,99 = 4
1 =User can turn OFFO/P1 …. 8 =User can turnOFFO/P8
P15E 1-100E RADIO PENDANTPANIC ALARM TOAN OUTPUT
1 =Radio Panicto O/P 1…. 8 =Radio Panic toO/P 8
U 21 – 100 =
1 & 2
P18E 1-100E LEARN RADIO PENDANTTRANSMITTER CODE
P19E 1-100E DELETE ASPECIFICRADIO PENDANTTRANSMITTER CODE
P20E 1-100E FIND ASPECIFIC RADIO PENDANTTRANSMITTER CODE
P21E 1-100E LEARN ACCESS TAG/ CARD CODE
P22E 1-100E DELETE ASPECIFICACCESS TAG /CARD CODE
P23E 1-100E FIND ASPECIFIC ACCESS TAG/ CARD CODE

3
MISCELLANEOUS PANEL SETTINGS
ADDRESS DESCRIPTION DEFAULT NEW
P25E 1E INSTALLERCODE 0 0 0 0 0 0
P25E 2E DURESS DIGIT 0 =DISABLED
P25E 3E DIAL REPORT DELAY (0-255 SECONDS) 0
P25E 4E RADIO DETECTOR SUPERVISED TIMER (0-9999 min) 2880 MIN
P25E 5E TWOTRIGGER TIMER (0-255 sec) 60 sec
P25E 6E MAINS FAIL REPORTINGDELAY (0-9999 sec) 900 sec
P25E 7E RECEIVER FAIL DELAY (0-9999 SEC) 0 sec
(DISABLED)
P25E 8E UPLOAD/DOWNLOAD SITECODE NUMBER (Up to 8 Characters) NONE
P25E 9E TEMPORARY OUTPUTDISABLE (Output 1-8)
P25E 10E MISCELLANEOUS PANEL OPTIONS
1 =PanelTamper is2k2 EOL
2 =Direct access to program mode forthe installer code
3 =Disable MainsFailTest
4 =Listen-into O/P# 1 LowVolume
5 =Receiver Fail Lockout (no signalor jamming)
6 =Send output information to keypad bus
7 =Cannot armif the system battery islow& AC Fail
8 =Installer Lockout
1,2,6
P25E 11E MISCELLANEOUS PANEL OPTIONS
1 = Entryto Installer Mode (via Client Prog Mode) MUST Reset
Confirmed Alarms
2 = Entryto Installer Mode (via Client Prog Mode) MUST Reset
Tamper Alarms
3 = Entryto Installer Mode (via Client Prog Mode) MUST Reset Low
BatteryAlarm
4 = Entryto Installer Mode (via Client Prog Mode) MUST Reset
SupervisoryAlarms
5 = CanNot Arm if there is a keypad Fault or Missing Keypad
6 = CanNot Arm if there is a Telephone Line Failure orComms Fault
7 =Keypad Lockout for 90 Seconds after10 Incorrect Code Attempts
8 =User codesmust be 4-6digitslong
NONE
P25E 13E MISCELLANEOUS USER OPTIONS
1 =Code Requiredto ViewMemory
2 =CancelHandoverZone Function in Stay Mode
3 =OutputControl from Keypad isDisabled when Armed
4 =Keypad Codesare Disabled During EntryDelay
5 =NoKeypad Indicationswhile Armed
6 =MonitoredKP Buss Output Board
7 =Enable Keypad Tamper
8 =LimitEventsLogging &Dialler Reporting to3 Only from Each Zone
During Each Armed Period.
2

4
CLOCK SETTINGS
ADDRESS DESCRIPTION DEFAULT NEW
P26E 1E REALTIME HOUR/MINUTE (0-2359)
P26E 2E REALTIME DAY OF WEEK (1-7) (1=Sunday, 2=Monday and so on)
P26E 3E REALTIME DATE/MONTH/YEAR (DD/MM/YY)
P26E 4E DAYLIGHT SAVING IS ACTIVE
IfOption-1 isOn,Daylight Saving iscurrentlyactive.
Turn Option-1 ON if you are in Daylight Saving Time when the panelis
installed.
P27E 1E DAYLIGHT SAVING START SUNDAY 1 =ENABLED 1
P27E 2E DAYLIGHT SAVING ENDSUNDAY 3
P28E 1E DAYLIGHT SAVING START MONTH (1-12) 10
P28E 2E DAYLIGHT SAVING ENDMONTH (1-12) 3
P29E 1E DAYLIGHT SAVING START HOUR (0-23) 2
P29E 2E DAYLIGHT SAVING ENDHOUR (0-23) 2
OUTPUTS
ADDRESS DESCRIPTION DEFAULT NEW
P34E 1-8E PROGRAMMINGOUTPUTOPTIONS A
1 =InvertOutput
2 =Flash Output
3 =Single Pulse to Output
4 =LockoutOutput
5 =DTMF RemoteControl can operate Output
6 =User Can operate thisOutput
7 =Controlbutton Can Operate Output
8 =ChimeAlarms Flash thisOutput(linked to Pulse Timer)
O/P1 =0
O/P2 =0
O/P3 =0
O/P4 =3
O/P5 =0
O/P6 =0
O/P7 =0
O/P8 =0
P35E 1-8E PROGRAMMINGOUTPUTOPTIONS B
1 =MainsFailtoOutput (Operateswhen P25E6E timeout)
2 =Fuse Failure to Output
3 =BatteryLowto output
4 =Telephone LineFailureto Output
5 =Zone RadioSupervised SignalFailure
6 =Sensor-Watch Alarm
7 =System Tamperto Output (Only WhenArmed to Outputs 1, 2& 3)
8 =Receiver Failure
O/P1, 2, 3 =
7
O/P4-8
=NONE
P36E 1-8E PROGRAMMINGOUTPUTOPTIONS C
1 =WalkTest Pulse toOutput(only for Outputs 1 & 2)
2 =Pulse Output every 5secondswhen Disarmed
3 =Pulse Output on Kiss-off Following Arming
4 =Pulse Output on Kiss-off Following a Zone Alarm
5 =Disable DuringdialDelay (P25E3E)
6 =Spare
7 =Spare
8 =Spare
O/P1, 2=1
O/P3-8 =
NONE

5
OUTPUTS –Cont.
ADDRESS DESCRIPTION DEFAULT NEW
P37E 1-8E PROGRAMMINGOUTPUTOPTIONS D
1 =SirenDrivertoOutput(requiresa horn speaker, outputs1&2)
2 =OutputReset/ChimeTimersare inMinutes
3 =Output muted for 10 secondson key-pressifalarm
4 =Turn Output OFFduring TwoWay Voice Mode
5 =Not used
6 =Not used
7 =Not used
8 =MonitoredOutput(1&2 only) can tellifsiren cableiscut
O/P1-8 =
NONE
P38E 1-8E OUTPUTON DELAYTIME Enter a value 0-9999 SecondsO/P1-8 =0
secs
P39E 1-8E OUTPUT PULSE TIME Enter avalue0-255 for 1/10th Sec increments
Output 1=3, Output2 =7,Output 3 = 3, Output4 =10, Output 5-8 = 0
P40E 1-8E OUTPUT RESETTIME Enter avalue0-9999 Seconds(Default=300
Sec) (ifoption 2at P37E ison the reset timeisinminutes)
Output 1=300, Output 2=0 (Latching),Output 3 =300, Output 4 =5,
Default 5-8=0
P41E 1-8E OUTPUT CHIME MODE TIME Entera value 0-255 for 1/10th Sec
increments(Eg:20 =2Sec,50 =5Sec,255 =25.5Sec)
P42E 1-8E START OFOUTPUT COMMAND CONTROL STATUSMESSAGES
Enter a value 0-99 (Eg: If aVoiceBoard is fitted to the panel, Enterthe
Message Number asprogrammed inthe Voice Boards)
O/P1-8 =0
P43E 1-8E UN-MAP AN OUTPUT RemoveALL defaults fromthe Output
P44E 1-8E ASSIGNINGATIME-ZONE TOAN OUTPUT Time-zonesthat control
output 1-8. Outputs1-8 Entera time-zone 1-8
NONE
AREAS
ADDRESS DESCRIPTION DEFAULT NEW
P45E 1-2E AREAS A& B OPTIONSA. 1 =Area A and 2=Area B.
1 =Armbutton required before code to Arm (set)
2 =Stay button required before code to Arm (set) stay mode
3 =Code required to Arm (set)
4 =Code required to bypass zones
5 =Not used
6 =Send Arm (Closing) atthe end ofthe ExitDelay
7 =Can Armonlyif AllZonesare Sealed (Ready)
8 =Can ArmStay Mode onlyif AllZonesare Sealed (Ready)
NONE
P46E 1-2E AREAS A& B OPTIONSB. 1 = Area Aand 2=Area B.
1 =Use near and verified alarm reporting forall zonesin thisarea
2 =Area willArmat End ofTime-Zone
3 =Area willDisarm atBeginning ofTime-Zone
4 =Assign beepsto access tags
5 =Not used
6 =Not used
7 =Cannot Arm if Zone Unsealed at end ofExit Delay
8 =Not used
NONE
P47E 1-2E AREAS A& B ARM INDICATIONTO OUTPUT
1=Area A and 2=Area B
Area A &B ArmIndication to Output. Entera value of 1-8 for each of
the 2 Area’sasrequired.
NONE

6
AREAS – Cont.
ADDRESS DESCRIPTION DEFAULT NEW
P48E 1-2E AREAS A& B STAY ARM INDICATION TO OUTPUT
1=Area A and 2=Area B
Area A &B ArmIndication to Output. Enter a value of1-8 for each of
the 2 Area’sasrequired.
NONE
P49E 1-2E AREAS A& B DISARM INDICATION TOOUTPUT
1=Area A and 2=Area B
Area A &B ArmIndication to Output. Enter a value of1-8 for each of
the 2 Area’sasrequired.
NONE
P50E 1-2E AREAS A& B PENDANT/ TAG ARM INDICATION TOOUTPUT
1=Area A and 2=Area B
Area A &B ArmIndication to Output. Enter a value of1-8 for each of
the 2 Area’sasrequired.
Area A =1,2
Area B =
1,2,3
P51E 1-2E AREAS A& B PENDANT/ TAG STAY ARM INDICATION TO
OUTPUT1 =Area A and 2=Area B
Area A &B ArmIndication to Output. Enter a value of1-8 for each of
the 2 Area’sasrequired.
Area A =1,2
Area B =1,2
P52E 1-2E AREAS A& B PENDANT/ TAG DISARM INDICATIONTO OUTPUT
1=Area A and 2=Area B
Area A &B ArmIndication to Output. Enter a value of1-8 for each of
the 2 Area’sasrequired.
Area A =1,2
Area B =
1,2,3
P53E 1-2E AREAS A& B PENDANT/ TAG STAY DISARM INDICATIONTO
OUTPUT1 =Area A and 2=Area B
Area A &B ArmIndication to Output. Enter a value of1-8 for each of
the 2 Area’sasrequired.
Area A =1,2
Area B =1,2
P54E 1-2E AREAS A& B ARM PULSEINDICATION TOOUTPUT
1=Area A and 2=Area B
NONE
P55E 1-2E AREAS A& B STAY ARM PULSE INDICATION TO OUTPUT
1=Area A and 2=Area B
NONE
P56E 1-2E AREAS A& B DISARM PULSE INDICATIONTO OUTPUT
1=Area A and 2=Area B
NONE
P57E 1-2E AREAS A& B STAY DISARM PULSEINDICATION TOOUTPUT
1=Area A and 2=Area B
NONE
P58E 1-2E AREAS A& B ARMED MODEEXIT DELAY BEEPSTO KEYPAD
1=Area A and 2=Area B
Keypad 1 &
2 ON
P59E 1-2E AREAS A& B STAY ARMED MODE EXIT DELAY BEEPS TO
KEYPAD 1 =Area A and 2=Area B
Keypad 1 &
2 ON
P60E 1-2E AREAS A& B ARMED EXIT DELAYTIME 0-255Sec’s 60
P61E 1-2E AREAS A& B STAY ARMED EXIT DELAYTIME 0-255Sec’s 60
P62E 1-2E AREAS A& B MONITORING ACCOUNTNUMBER
1=Area A and 2=Area B
A & B =
0000
P63E 1-2E AREAS A& B REMOTECONTROL COMMAND CODE NUMBER
1=Area A and 2=Area B ( Requires Voice Module )
A & B =0
P64E 1-2E AREAS A& B STARTMESSAGE NUMBER FOR REMOTE
CONTROL COMMAND ( Requires Voice Module )
A & B =0
P65E 1-2E AREAS A& B ARMED EXITE DELAYTO OUTPUT
1=Area A and 2=Area B
NONE
P66E 1-2E AREAS A& B STAY ARMED EXITEDELAYTO OUTPUT
1=Area A and 2=Area B
NONE
P67E 1-2E AREAS A& B DELINQUICY DELAY 1 =Area A and 2=Area B NONE
P68E 1-2E AREAS A& B AUTO ARM / DISARM TIME ZONE
1=Area A and 2=Area B
NONE

7
KEYPADS
ADDRESS DESCRIPTION DEFAULT NEW
P71E 1-8E KEYPAD TO AREAASSIGNMENT
1=Area A and 2=Area B
K/P 1-8 = 1
(AREA A)
P72E 1-8E KEYPAD BUTTONOPTIONS
1 CHIME or CONTROL PROGRAM buttonsenabled
2 BYPASS button enabled
3 PANIC button enabled
4Delayed panicon PANIC button
5<1>+<3>(on LED K/P)or <CONTROL>+<CHIME>(on LCD K/P)=
Panic Alarm Enabled
6<4>+<6>(on LED K/P)or <A>+<B>(onLCD K/P)=FireAlarm
Enabled
7<7>+<9>(on LED K/P)or <B>+<CHIME>(on LCD K/P) =Medical
Alarm Enabled
8Stay Armed Beep to Keypad
K/P 1-8 = 1-8
ON
P73E 1-8E ALARM BEEPS &LEDCONTROLTOKEYPAD
1 MainsFail BeepsKeypad Buzzer
2 Fuse Failure BeepsKeypad Buzzer
3 BatteryLowBeepsKeypad Buzzer
4Telephone Line FailureBeepsKeypad Buzzer
5System TamperAlarmBeepsKeypad Buzzer
6Receiver Fail BeepsKeypad Buzzer
7Turn Off Keypad LED’swhen Armed /after 90 sec if not touched
8Turn Off Keypad &Backlight LED’son MainsFailure
K/P 1-8 = 5
& 8 ON
P74E 1-8E KEYPAD ARM BUTTON TOAREA
1 ARM Button assigned to Area A
2 ARM Button assigned to Area B
K/P 1-8 = 1
ON
P75E 1-8E KEYPAD ARM BUTTON TOAREAOPTIONS
1 ARM Button can Arm
2 ARM Button can Stay Mode Arm
3 ARM Button can Disarm atAll Times
4ARM Button can Disarm StayMode atAllTimes
5ARM Button can Reset Alarms
6ARM Button can ArmLatchkey Mode
7ARM Button can Disarm DuringExitDelay
8ARM Button can Disarm StayMode During ExitDelay
K/P 1-8 = 1
& 7 ON
P76E 1-8E KEYPAD STAY BUTTON TOAREA
1 STAY Buttonassigned to Area A
2 STAY Buttonassigned to Area B
K/P 1-8 = 1
ON
P77E 1-8E KEYPAD ARM BUTTON TOAREAOPTIONS
1 STAY Buttoncan Arm
2 STAY Buttoncan StayMode Arm
3 STAY Buttoncan Disarmat AllTimes
4STAY Buttoncan DisarmStay Mode at AllTimes
5STAY Buttoncan Reset Alarms
6STAY Buttoncan Arm LatchkeyMode
7STAY Buttoncan DisarmDuring Exit Delay
8STAY Buttoncan DisarmStay Mode During Exit Delay
K/P 1-8 = 2
& 8 ON
P78E 1-8E KEYPAD ABUTTON TOAREA
1 A Button assigned to Area A
2 A Button assigned to Area B
K/P 1-8 = 1
ON

8
KEYPADS– Cont.
ADDRESS DESCRIPTION DEFAULT NEW
P79E 1-8E KEYPAD ABUTTON TOAREAOPTIONS
1 ‘A’ Button can Arm
2 ‘A’ Button can StayMode Arm
3 ‘A’ Button can DisarmatAllTimes
4‘A’ Button can DisarmStay Mode at AllTimes
5‘A’ Button can Reset Alarms
6‘A’ Button can Arm Latchkey Mode
7‘A’ Button can DisarmDuring ExitDelay
8‘A’ Button can DisarmStay Mode During Exit Delay
K/P 1-8 = 1
& 7 ON
P80E 1-8E KEYPAD B BUTTON TOAREA
1 ‘B’ Button assigned to Area A
2 ‘B’ Button assigned to Area B
K/P 1-8 = 2
ON
P81E 1-8E KEYPAD ABUTTON TOAREAOPTIONS
1 ‘B’ Button can Arm
2 ‘B’ Button can StayMode Arm
3 ‘B’ Button can DisarmatAllTimes
4‘B’ Button can DisarmStay Mode at AllTimes
5‘B’ Button can Reset Alarms
6‘B’ Button can Arm Latchkey Mode
7‘B’ Button can DisarmDuring ExitDelay
8‘B’ Button can DisarmStay Mode During Exit Delay
K/P 1-8 = 1
& 7 ON
P82E 1-8E KEYPAD MAPPED TOOUTPUT MASK FOR ACCESS CONTROL
1 KEYPADISMAPPED TOOUTPUT 1
2 KEYPADISMAPPED TOOUTPUT 2
3 KEYPADISMAPPED TOOUTPUT 3
4KEYPADISMAPPED TOOUTPUT 4
5KEYPADISMAPPED TOOUTPUT 5
6KEYPADISMAPPED TOOUTPUT 6
7KEYPADISMAPPED TOOUTPUT 7
8KEYPADISMAPPED TOOUTPUT 8
K/P 1=1 ON
K/P 2=2 ON
K/P 3=3 ON
K/P 4=4 ON
K/P 5=5 ON
K/P 6=6 ON
K/P 7=7 ON
K/P 8=8 ON
P83E 1-8E CONTROL BUTTONMAPPED TO OUTPUTMASK FOR ACCESS
CONTROL
1 CONTROL BUTTON IS MAPPEDTOOUTPUT 1- 8
2 CONTROL BUTTON IS MAPPEDTOOUTPUT 1- 8
3 CONTROL BUTTON IS MAPPEDTOOUTPUT 1- 8
4CONTROL BUTTON IS MAPPEDTOOUTPUT 1- 8
5CONTROL BUTTON IS MAPPEDTOOUTPUT 1- 8
6CONTROL BUTTON IS MAPPEDTOOUTPUT 1- 8
7CONTROL BUTTON IS MAPPEDTOOUTPUT 1- 8
8CONTROL BUTTON IS MAPPEDTOOUTPUT 1- 8
K/P 1=1-8 ON
K/P 2=1-8 ON
K/P 3=1-8 ON
K/P 4=1-8 ON
K/P 5=1-8 ON
K/P 6=1-8 ON
K/P 7=1-8 ON
K/P 8=1-8 ON
P84E 1-8E KEYPAD PANIC OR <1>+<3>ALARMS TOOUTPUT
1 KEYPADPANICOR<1>+<3>TURNS ON OUTPUT 1
2 KEYPADPANICOR<1>+<3>TURNS ON OUTPUT 2
3 KEYPADPANICOR<1>+<3>TURNS ON OUTPUT 3
4KEYPADPANICOR<1>+<3>TURNS ON OUTPUT 4
5KEYPADPANICOR<1>+<3>TURNS ON OUTPUT 5
6KEYPADPANICOR<1>+<3>TURNS ON OUTPUT 6
7KEYPADPANICOR<1>+<3>TURNS ON OUTPUT 7
8KEYPADPANICOR<1>+<3>TURNS ON OUTPUT 8
K/P 1-8=1-3
ON

9
KEYPADS– Cont.
ADDRESS
DESCRIPTION
DEFAULT
NEW
P85E 1-8E KEYPAD FIRE OR <4> +<6>ALARMS TO OUTPUT
1 KEYPAD FIRE OR <4> + <6> TURNS ON OUTPUT1
2 KEYPAD FIRE OR <4> + <6> TURNS ON OUTPUT2
3 KEYPAD FIRE OR <4> + <6> TURNS ON OUTPUT3
4KEYPAD FIRE OR <4> + <6> TURNS ON OUTPUT4
5KEYPAD FIRE OR <4> + <6> TURNS ON OUTPUT5
6KEYPAD FIRE OR <4> + <6> TURNS ON OUTPUT6
7KEYPAD FIRE OR <4> + <6> TURNS ON OUTPUT7
8KEYPAD FIRE OR <4> + <6> TURNS ON OUTPUT8
K/P 1-8=1-3
ON
P86E 1-8E KEYPAD MEDICAL OR <7>+<9>ALARMS TO OUTPUT
1 KEYPAD MEDICAL OR <7> + <9> TURNS ON OUTPUT1
2 KEYPAD MEDICAL OR <7> + <9> TURNS ON OUTPUT2
3 KEYPAD MEDICAL OR <7> + <9> TURNS ON OUTPUT3
4KEYPAD MEDICAL OR <7> + <9> TURNS ON OUTPUT4
5KEYPAD MEDICAL OR <7> + <9> TURNS ON OUTPUT5
6KEYPAD MEDICAL OR <7> + <9> TURNS ON OUTPUT6
7KEYPAD MEDICAL OR <7> + <9> TURNS ON OUTPUT7
8KEYPAD MEDICAL OR <7> + <9> TURNS ON OUTPUT8
K/P 1-8 = 2
ON
P87E 1-8E KEYPAD DURESS ALARM TO OUTPUT
1 KEYPAD DURESS TURNS ON OUTPUT1
2 KEYPAD DURESS TURNS ON OUTPUT2
3 KEYPAD DURESS TURNS ON OUTPUT3
4KEYPAD DURESS TURNS ON OUTPUT4
5KEYPAD DURESS TURNS ON OUTPUT5
6KEYPAD DURESS TURNS ON OUTPUT6
7KEYPAD DURESS TURNS ON OUTPUT7
8KEYPAD DURESS TURNS ON OUTPUT8
NONE
P88E 1-8E KEYPAD TAMPER SWITCH ALARM TO OUTPUT
1 KEYPAD TAMPER TURNS ON OUTPUT1
2 KEYPAD TAMPER TURNS ON OUTPUT2
3 KEYPAD TAMPER TURNS ON OUTPUT3
4KEYPAD TAMPER TURNS ON OUTPUT4
5KEYPAD TAMPER TURNS ON OUTPUT5
6KEYPAD TAMPER TURNS ON OUTPUT6
7KEYPAD TAMPER TURNS ON OUTPUT7
8KEYPAD TAMPER TURNS ON OUTPUT8
NONE
P89E 1-8E KEYPAD WRONG CODE ALARM TOOUTPUT
1 KEYPAD WRONG CODE TURNS ON OUTPUT1 & 2
2 KEYPAD WRONG CODE TURNS ON OUTPUT1 & 2
3 KEYPAD WRONG CODE TURNS ON OUTPUT1 & 2
4KEYPAD WRONG CODE TURNS ON OUTPUT1 & 2
5KEYPAD WRONG CODE TURNS ON OUTPUT1 & 2
6KEYPAD WRONG CODE TURNS ON OUTPUT1 & 2
7KEYPAD WRONG CODE TURNS ON OUTPUT1 & 2
8KEYPAD WRONG CODE TURNS ON OUTPUT1 & 2
K/P 1-8 =
O/P1 &2
P90E 1-8E MANUALLY OPERATEDPANIC ALARM BEEPS THE KEYPAD
1 A Panic Alarm at the selected keypad BeepsKP #1
2 A Panic Alarm at the selected keypad BeepsKP #2
3 A Panic Alarm at the selected keypad BeepsKP #3
4A Panic Alarm at the selected keypad BeepsKP #4
5A Panic Alarm at the selected keypad BeepsKP #5
6A Panic Alarm at the selected keypad BeepsKP #6
7A Panic Alarm at the selected keypad BeepsKP #7
8A Panic Alarm at the selected keypad BeepsKP #8
K/P 1-8 = 1-8
ON

10
KEYPADS– Cont.
ADDRESS DESCRIPTION DEFAULT NEW
P91E 1-8E MANUALLY OPERATEDFIRE ALARM BEEPS THE KEYPAD
1 A FireAlarmatthe selected keypad BeepsKP # 1
2 A FireAlarmatthe selected keypad BeepsKP # 2
3 A FireAlarmatthe selected keypad BeepsKP # 3
4A FireAlarmatthe selected keypad BeepsKP # 4
5A FireAlarmatthe selected keypad BeepsKP # 5
6A FireAlarmatthe selected keypad BeepsKP # 6
7A FireAlarmatthe selected keypad BeepsKP # 7
8A FireAlarmatthe selected keypad BeepsKP # 8
K/P 1-8 = 1-8
ON
P92E 1-8E MANUALLY OPERATEDMEDICAL ALARM BEEPS THE KEYPAD
1 A Medical Alarmatthe selected keypad BeepsKP # 1
2 A Medical Alarmatthe selected keypad BeepsKP # 2
3 A Medical Alarmatthe selected keypad BeepsKP # 3
4A Medical Alarmatthe selected keypad BeepsKP # 4
5A Medical Alarmatthe selected keypad BeepsKP # 5
6A Medical Alarmatthe selected keypad BeepsKP # 6
7A Medical Alarmatthe selected keypad BeepsKP # 7
8A Medical Alarmatthe selected keypad BeepsKP # 8
K/P 1-8 = 1-8
ON
P93E 1-8E WRONG CODE OR KEYPAD TAMPER SWITCHALARM BEEPS
THE KEYPAD
1 AWrong Code or KPTamperAlarmatthe selected keypad Beeps
KP # 1
2 AWrong Code or KPTamperAlarmatthe selected keypad Beeps
KP # 2
3 AWrong Code or KPTamperAlarmatthe selected keypad Beeps
KP # 3
4A Wrong Code or KPTamperAlarmatthe selected keypad Beeps
KP # 4
5A Wrong Code or KPTamperAlarmatthe selected keypad Beeps
KP # 5
6A Wrong Code or KPTamperAlarmatthe selected keypad Beeps
KP # 6
7A Wrong Code or KPTamperAlarmatthe selected keypad Beeps
KP # 7
8A Wrong Code or KPTamperAlarmatthe selected keypad Beeps
KP # 8
K/P 1-8 =
NONE
P94E 1-8E CHIME ALARM BEEP TIME ATAKEYPAD
The Timethe Chime Alarm soundsat Each Keypad enter a value 0-255
1/10th sec.
K/P 1-8 = 20
(2Sec)
P98E 1-8E PROXIMITY READER LED TO OUTPUT MAPPING
1 Proximity Reader 1-8 LEDfollowsthe state ofOutput # 1
2 Proximity Reader 1-8 LEDfollowsthe state ofOutput # 2
3 Proximity Reader 1-8 LEDfollowsthe state ofOutput # 3
4 Proximity Reader 1-8 LEDfollowsthe state ofOutput # 4
5 Proximity Reader 1-8 LEDfollowsthe state ofOutput # 5
6 Proximity Reader 1-8 LEDfollowsthe state ofOutput # 6
7 Proximity Reader 1-8 LEDfollowsthe state ofOutput # 7
8 Proximity Reader 1-8 LEDfollowsthe state ofOutput # 8
K/P 1-8 =
NONE
P99E 1-8E LEARN PROXIMITY READER KEYPAD ADDRESS NUMBER

11
KEYSWITCH
ADDRESS DESCRIPTION DEFAULT NEW
P111E 1-2E KEYSWITCH AREAASSIGNMENT – assign the Key-Switch to
AREAS Aor B
K/S 1&2=
None
P112E 1-2E KEYSWITCH OPTIONS
1 K/Scan Arm Area
2 K/Scan armStayMode
3 K/Scan DisarmArea
4 K/Scan disarmStay Mode
5 K/ShasSecurityGuard Options
6 K/SwillArm LatchkeyMode
7 Key-switch isN/O (Ifturned off the Key-Switch isN/C)
8 Key-switch isMomentary(Ifturned offthe K/S isLatched)
K/S 1&2=
1,3,7,8
ZONES
ADDRESS DESCRIPTION DEFAULT NEW
P121E 1-16E
(Runner 8 =1-8)
PROGRAMMINGZONESTOAREAS (Runner-8 =Only Zones 1-8)
1 Assigned to area A
2 Assigned to area B
Zone 1-16 =
1
P122E 1-16E
(Runner 8 =1-8)
ProgrammingZoneOptionsA (Runner-8 =Only Zones 1-8 avail)
1 Zone isActive
2 Zone isN/O(Off = N/C)
3 Not an ExitDelayZone
4 Keypad Zone
5 Zone isa Radio Zone
6Stay Mode Zone
7 Zone can be ManuallyBypassed
8 Zone can be Auto-Bypassed
Runner-8
Zone 1-4 =
1,6,7
Zone 5-8 =
6,7
Runner-16
Zone 1-8 =
1,6,7
Zone 9-16 =
6,7
P123E 1-16E
(Runner 8 =1-8)
ProgrammingZoneOptionsB (Runner-8 =Only Zones 1-8 avail)
1 Zone isa Handover Zone
2 Zone isa Two TriggerZone
3 Zone isa 24 HourZone
4 Zone isa 24 HourAuto-reset Zone
5 Zone isa 24 HourFire Zone
6 Spare
7 Zone isa ChimeZone
8 Zone isa Permanent Chime Zone
Runner-8
Zone 1-8 =
None
Runner-16
Zone 1-16 =
None
P124E 1-16E
(Runner 8 =1-8)
ProgrammingZoneOptionsC (Runner-8 =Only Zones 1-8 avail)
1 Can Armif Zone isnot Ready
2 SendsMultiple Reports via Dialler
3 Sensor-WatchZone
4 Zone ison SoakTest
5 Zone willreporttoArea BAccountNumber
6 Zone willNotReport 24 hour Alarms via Dialler
7 Pulse Outputon Kiss-offFollowing a Zone Alarm
8 Exit Terminator Zone
Runner-8
Zone 1-8 =
1,2
Runner-16
Zone 1-16 =
1,2

12
ZONES– Cont.
ADDRESS DESCRIPTION DEFAULT NEW
P125E 1-8E
(Runner 8 =1-4)
ProgrammingZoneEOL Resistor Options (Runner-8=Only Zn’s 1-4)
0 Short Circuit Loop (NoResistor)
1 Terminated with a1K resistor
2 Terminated with a1K5 resistor
3 Terminated with a2K2 resistor
4 Terminated with a3K3 resistor
5 Terminated with a3K9 resistor
6 Terminated with a4K7 resistor
7 Terminated with a5K6 resistor
8 Terminated with a6K8 resistor
9 Terminated with a10K resistor
10 Terminated with a 12Kresistor
11 Terminated with a 22Kresistor
12 Terminated with a 2K2/4K7 resistor
13 Terminated with a 3K3/6K8 resistor
14 Terminated with a 2K2/4K7 /8K2 resistor
15 Terminated with a 4K7/8K2 resistor
Runner-8
Zone 1-4 =3
Runner-16
Zone 1-8 =3
P126E 1-8E
(Runner 8 =1-4)
ProgrammingZoneResponse Type (Runner-8 =Only Zones 1-4)
For Vibration ContactsP125 must be type 3 =2K2
1-8 Vibration Contact Mode.1 =HIGH sensitivity,8 =LOWEST
sensitivity
9 NormalAlarm Relay type input
Runner-8
Zone 1-4 =9
Runner-16
Zone 1-8 =9
P127E 1-16E
(Runner 8 =1-8)
ProgrammingRadioZone Type (Runner-8 =Only Zones 1-8 avail)
0 GenericDevice Alarm SignalOnly(will Not monitor device Low-Bat,
Tamper or Supervision signals)
1 CrowMerlinPIR (supervised signalignored - 433MHz AM)
2 CrowMerlinPIR (supervised signalactive- 433MHz AM)
3 CrowFreeWavew/Checksum(supervision Active–433 or 916MHz
FM)
4 CrowFreeWavew/Checksum(supervision NonActive–433 or
916MHz FM)
5 CrowAE seriesbattery Low(304MHz AM)
6 CrowAE seriesRadio Reed Switch (304MHz AM)
11 NessRadio devicesBatteryLow(304MHz AM)
12 NessRadio Reed Switch (304MHz AM)
21 ElectronicsLine Radio PIR -433MHz AM
31 Visonic K900 Radio PIR
32 Visonic Power code (supervised signalignored - 433MHz AM)
33 Visonic Power code (supervised signalactive- 433MHz AM)
34 Siemens(Supervised SignalIgnored)
35 Siemens(Supervised SignalActive)
Runner-8
Zone 1-8 =3
Runner-16
Zone 1-16 =
3
P128E 1-16E
(Runner 8 =1-8)
ARMED ZONE ALARMS TO OUTPUTS (Runner-8 =Zones 1-8 avail)
1 Zone AlarmTurnsOn Output# 1
2 Zone AlarmTurnsOn Output# 2
3 Zone AlarmTurnsOn Output# 3
4 Zone AlarmTurnsOn Output# 4
5 Zone AlarmTurnsOn Output# 5
6 Zone AlarmTurnsOn Output# 6
7 Zone AlarmTurnsOn Output# 7
8 Zone AlarmTurnsOn Output# 8
Runner-8
Zone 1-8 =
1,2,3
Runner-16
Zone 1-16 =
1,2,3
EOL Resistorsin Options1~11
and the 2k2 & 3k3inOptions
12~14 MUST be connected in
Serieswith the Zn Circuit
(i.e.: Between Relay & Tamper
TerminalsofPIR).
The 4k7, 6k8& 8k2 EOL’sin
Options12~15 MUST be
connected in Parallel Across the
Alarm (Relay)Contactsof the
Detection Device. See Diagrams
at rear of manual.

13
ZONES– Cont.
ADDRESS DESCRIPTION DEFAULT NEW
P129E 1-16E
(Runner 8 =1-8)
STAY ARMED ZONEALARMS TOOUTPUTS (Runner-8 =Only
Zones 1-8 avail)
1 STAY Zone AlarmTurnsOn Output # 1
2 STAYZone AlarmTurnsOn Output # 2
3 STAYZone AlarmTurnsOn Output # 3
4 STAYZone AlarmTurnsOn Output # 4
5 STAYZone AlarmTurnsOn Output # 5
6 STAYZone AlarmTurnsOn Output # 6
7 STAYZone AlarmTurnsOn Output # 7
8 STAYZone AlarmTurnsOn Output # 8
Runner-8
Zone 1-8 =
1,2,3
Runner-16
Zone 1-16 =
1,2,3
P130E 1-16E
(Runner 8 =1-8)
24 HOUR ZONEALARMS TO OUTPUTS (Runner-8 = Only Zones 1-
8 avail)
1 24 Hour Zone Alarm TurnsOn Output# 1
2 24 Hour Zone Alarm TurnsOn Output# 2
3 24 Hour Zone Alarm TurnsOn Output# 3
4 24 Hour Zone Alarm TurnsOn Output# 4
5 24 Hour Zone Alarm TurnsOn Output# 5
6 24 Hour Zone Alarm TurnsOn Output# 6
7 24 Hour Zone Alarm TurnsOn Output# 7
8 24 Hour Zone Alarm TurnsOn Output# 8
Runner-8
Zone 1-8 =
1,2,3
Runner-16
Zone 1-16 =
1,2,3
P131E 1-16E
(Runner 8 =1-8)
CHIME ZONEALARMS TOOUTPUTS (Runner-8 =Only Zones 1-8
avail)
1 Chime Zone AlarmTurnsOn Output# 1
2 ChimeZone AlarmTurnsOn Output# 2
3 ChimeZone AlarmTurnsOn Output# 3
4 ChimeZone AlarmTurnsOn Output# 4
5 ChimeZone AlarmTurnsOn Output# 5
6 ChimeZone AlarmTurnsOn Output# 6
7 ChimeZone AlarmTurnsOn Output# 7
8 ChimeZone AlarmTurnsOn Output# 8
Runner-8
Zone 1-8 =
None
Runner-16
Zone 1-16 =
None
P132E 1-16E
(Runner 8 =1-8)
ZONE TAMPER ALARMS TO OUTPUTS (Runner-8 = Only Zones 1-
8 avail)
1 Zone TamperAlarmTurnsOn Output #1
2 Zone TamperAlarmTurnsOn Output #2
3 Zone TamperAlarmTurnsOn Output #3
4 Zone TamperAlarmTurnsOn Output #4
5 Zone TamperAlarmTurnsOn Output #5
6 Zone TamperAlarmTurnsOn Output #6
7 Zone TamperAlarmTurnsOn Output #7
8 Zone TamperAlarmTurnsOn Output #8
Runner-8
Zone 1-8 =
1,2,3
Runner-16
Zone 1-16 =
1,2,3
P134E 1-16E
(Runner 8 =1-8)
ARMED ZONE ALARM BEEPS TO KEYPADS (Runner-8 =Only
Zones 1-8 avail)
1 Armed Zone Alarm BeepsKeypad #1
2 Armed Zone Alarm BeepsKeypad #2
3 Armed Zone Alarm BeepsKeypad #3
4 Armed Zone Alarm BeepsKeypad #4
5 Armed Zone Alarm BeepsKeypad #5
6 Armed Zone Alarm BeepsKeypad #6
7 Armed Zone Alarm BeepsKeypad #7
8 Armed Zone Alarm BeepsKeypad #8
Runner-8
Zone 1-8 =
1,2
Runner-16
Zone 1-16 =
1,2

14
ZONES-Cont.
ADDRESS DESCRIPTION DEFAULT NEW
P135E 1-16E
(Runner 8 =1-8)
STAY MODEZONE ALARM BEEPS TO KEYPADS (Runner-8 =Only
Zones 1-8 avail)
1 Stay Mode Zone Alarm BeepsKeypad #1
2 Stay Mode Zone Alarm BeepsKeypad #2
3 Stay Mode Zone Alarm BeepsKeypad #3
4 Stay Mode Zone Alarm BeepsKeypad #4
5 Stay Mode Zone Alarm BeepsKeypad #5
6 Stay Mode Zone Alarm BeepsKeypad #6
7 Stay Mode Zone Alarm BeepsKeypad #7
8 Stay Mode Zone Alarm BeepsKeypad #8
Runner-8
Zone 1-8 =
1,2
Runner-16
Zone 1-16 =
1,2
P136E 1-16E
(Runner 8 =1-8)
24 HOUR ZONEALARM BEEPS TO KEYPADS (Runner-8 =Only
Zones 1-8 avail)
1 24 Hour Zone Alarm BeepsKeypad #1
2 24 Hour Zone Alarm BeepsKeypad #2
3 24 Hour Zone Alarm BeepsKeypad #3
4 24 Hour Zone Alarm BeepsKeypad #4
5 24 Hour Zone Alarm BeepsKeypad #5
6 24 Hour Zone Alarm BeepsKeypad #6
7 24 Hour Zone Alarm BeepsKeypad #7
8 24 Hour Zone Alarm BeepsKeypad #8
Runner-8
Zone 1-8 =
1,2
Runner-16
Zone 1-16 =
1,2
P137E 1-16E
(Runner 8 =1-8)
CHIME ZONEALARM BEEPS TOKEYPADS (Runner-8 =Only
Zones 1-8 avail)
1 ChimeZone AlarmBeepsKeypad #1
2 ChimeZone AlarmBeepsKeypad #2
3 ChimeZone AlarmBeepsKeypad #3
4 ChimeZone AlarmBeepsKeypad #4
5 ChimeZone AlarmBeepsKeypad #5
6 ChimeZone AlarmBeepsKeypad #6
7 ChimeZone AlarmBeepsKeypad #7
8 ChimeZone AlarmBeepsKeypad #8
Runner-8
Zone 1-8 =
1,2
Runner-16
Zone 1-16 =
1,2
P139E 1-16E
(Runner 8 =1-8)
ZONE TAMPER ALARM BEEPS TOKEYPADS (Runner-8 =Only
Zones 1-8 avail)
1 Zone TamperAlarmBeepsKeypad #1
2 Zone TamperAlarmBeepsKeypad #2
3 Zone TamperAlarmBeepsKeypad #3
4 Zone TamperAlarmBeepsKeypad #4
5 Zone TamperAlarmBeepsKeypad #5
6 Zone TamperAlarmBeepsKeypad #6
7 Zone TamperAlarmBeepsKeypad #7
8 Zone TamperAlarmBeepsKeypad #8
Runner-8
Zone 1-8 =
1,2
Runner-16
Zone 1-16 =
1,2
P140E 1-16E
(Runner 8 =1-8)
RADIO SUPERVISION ALARM BEEPS TOKEYPADS (Runner-8 =
Only Zones1-8 avail)
1 Radio SupervisionAlarmBeepsKeypad #1
2 Radio SupervisionAlarmBeepsKeypad #2
3 Radio SupervisionAlarmBeepsKeypad #3
4 Radio SupervisionAlarmBeepsKeypad #4
5 Radio SupervisionAlarmBeepsKeypad #5
6 Radio SupervisionAlarmBeepsKeypad #6
7 Radio SupervisionAlarmBeepsKeypad #7
8 Radio SupervisionAlarmBeepsKeypad #8
Runner-8
Zone 1-8 =
None
Runner-16
Zone 1-16 =
None

15
ZONES-Cont.
ADDRESS DESCRIPTION DEFAULT NEW
P141E 1-16E
(Runner 8 =1-8)
ZONESENSOR WATCHALARM BEEPS TO KEYPADS (Runner-8 =
Only Zones1-8 avail)
1 Zone Sensor WatchAlarm BeepsKeypad #1
2 Zone Sensor WatchAlarm BeepsKeypad #2
3 Zone Sensor WatchAlarm BeepsKeypad #3
4 Zone Sensor WatchAlarm BeepsKeypad #4
5 Zone Sensor WatchAlarm BeepsKeypad #5
6 Zone Sensor WatchAlarm BeepsKeypad #6
7 Zone Sensor WatchAlarm BeepsKeypad #7
8Zone Sensor WatchAlarm BeepsKeypad #8
Runner-8
Zone 1-8 =
None
Runner-16
Zone 1-16 =
None
P142E 1-16E
(Runner 8 =1-8)
ARMED ZONE ENTRYDELAY BEEPSTOKEYPADS (Runner-8 =
Only Zones1-8 avail)
1 Armed Zone EntryDelayBeepsKeypad #1
2 Armed Zone EntryDelayBeepsKeypad #2
3 Armed Zone EntryDelayBeepsKeypad #3
4 Armed Zone EntryDelayBeepsKeypad #4
5 Armed Zone EntryDelayBeepsKeypad #5
6 Armed Zone EntryDelayBeepsKeypad #6
7 Armed Zone EntryDelayBeepsKeypad #7
8Armed Zone EntryDelayBeepsKeypad #8
Runner-8
Zone 1-8 =
1,2
Runner-16
Zone 1-16 =
1,2
P143E 1-16E
(Runner 8 =1-8)
STAY MODEENTRY DELAY BEEPS TOKEYPADS (Runner-8 =
Only Zones1-8 avail)
1 Stay Mode EntryDelayBeepsKeypad #1
2 Stay Mode EntryDelayBeepsKeypad #2
3 Stay Mode EntryDelayBeepsKeypad #3
4 Stay Mode EntryDelayBeepsKeypad #4
5 Stay Mode EntryDelayBeepsKeypad #5
6 Stay Mode EntryDelayBeepsKeypad #6
7 Stay Mode EntryDelayBeepsKeypad #7
8Stay Mode EntryDelayBeepsKeypad #8
Runner-8
Zone 1-8 =1
Runner-16
Zone 1-16 =1
P144E 1-16E
(Runner 8 =1-8)
ARMED ZONE ENTRYDELAYTIMES – 0-9999 SECONDS
(Runner-8 =OnlyZones 1-8avail)
Zone 1=20 sec
Zone 2-16 =0
P145E 1-16E
(Runner 8 =1-8)
STAY MODEENTRY DELAYTIMES – 0-9999 SECONDS
(Runner-8 =OnlyZones 1-8avail)
Z
n 1-2=20sec
Zone
3-16 =0
P146E 1-16E
(Runner 8 =1-8)
ZONERE-TRIGGERCOUNTER – 0-15 TRIGGERS (ZONE LOCKOUT
COUNTER). A ‘0’ in thislocation =Unlimited Zone Triggersper Armed
Period. (Runner-8 =Only Zones 1-8 avail)
Zone 1-16 =
0
P157E 1-16E
(Runner 8 =1-8)
ZONEALARM CONTACT-ID REPORTINGCODE (3 digit Event Code)
(Runner-8 =OnlyZones 1-8avail)
Zone 1-16 =
130
P163E 1-16E
(Runner 8 =1-8)
SENSOR WATCH TIMER– 0-9999 MINUTES
(Runner-8 =OnlyZones 1-8avail)
Zone 1-16 =
7200 mins
P164E 1-16E
(Runner 8 =1-8)
ENROLLING (LEARNING) RADIO ZONES (Runner-8 =Only Zones
1-8 avail)
P164E +ZONE # +E+Ethen Release the Tamper Switch
P165E 1-16E
(Runner 8 =1-8)
DELETE ASPECIFICRADIO ZONE (Runner-8 =Only Zones 1-8
avail)
P165E +ZONE # +E+E
P166E 1-16E
(Runner 8 =1-8)
FINDING ARADIO DEVICES ZONE NUMBER (Runner-8 =Only
Zones 1-8 avail)
P166E +Ethen Release the Tamper Switch

16
TIME ZONES
ADDRESS DESCRIPTION DEFAULT NEW
P170E 1-8E PROGRAMMING HOLIDAYS – There are 8holidaysentered as
DDMMYY
P171E 1-8E PROGRAMMINGTIMEZONEDAYS OFTHE WEEK
1 Sunday
2 Monday
3 Tuesday
4 Wednesday
5 Thursday
6 Friday
7 Saturday
8Invert
None
P172E 1-8E TIMEZONESTARTTIME – Enter a value 0000-2359 0000
P173E 1-8E TIMEZONEEND TIME – Enter a value 0000-2359 0000
P174E 1-8E TIMEZONE1-8 OPTIONS
1 Ignore Holidays
2 Spare
None
DIALLER
ADDRESS DESCRIPTION DEFAULT NEW
P175E 1E DIALLER PROGRAMMINGOPTIONS 1
1 DiallerisEnabled
2 FaxDefeat
3 Disable Telephone Line Monitoring
4 DTMF or Pulse Dial (ForDTMF 4&5 must be bothOFF)
5 DTMF or Reverse Pulse Dial (For DTMF, 4&5 must be bothOFF)
6 Send long DTMFtonesduring dialling (MustbeONfor Aust.)
7 Auto Detect Modem Mode
8Force V21 Mode
2,6,7
P175E 2E DIALLER PROGRAMMINGOPTIONS 2
1 Step number on each call
2 Upload/Download use Callback
3 Upload/Download onlyifdisarmed
4 Test callsonlyif armed
5 Test TimePeriodis in days
6 Holdlineopen following Domestic/Voicereport for DTMF control
7 First to Open Last to Close Reporting
8Alarm EnablesAnswer (2 way Voice)
6
P175E 3E AUTO ANSWER RING COUNT – Enter avalue 0-99 17
P175E 4E TIME TO THEFIRST DIALLERTEST CALL – Enter a value 0-23599 0430
P175E 5E TEST CALL TIME PERIOD (HOURS) BETWEEN TEST REPORTS –
Enter a value 0-255 (0 = No Test)
168 Hrs
(Weekly)
P175E 6E KEYPAD LISTEN IN OPTIONSWHILE RUNNER IS DIALLING
1 Enabled During Dialling in Disarm State only
2 Enabled During Dialling inArmed State only
3 Enabled During Dialling inStay Mode Stateonly
4 Enabled Throughout the call inDisarmState only
5 Enabled Throughout the call in ArmedState only
6 Enabled Throughout the call inStayMode State only
7 Listen-in Enabled when the panelanswersa call
8Enabled at All Times
1-7 ON

17
DIALLER-Cont.
ADDRESS DESCRIPTION DEFAULT NEW
P175E 7E OUTPUT# 1 LISTENIN OPTIONS WHILE RUNNERIS DIALLING
1 Enabled During Dialling in Disarm State only
2 Enabled During Dialling inArmed State only
3 Enabled During Dialling inStay Mode Stateonly
4 Enabled Throughout the call inDisarmState only
5 Enabled Throughout the call in ArmedState only
6 Enabled Throughout the call inStayMode State only
7 Listen-in Enabled when the panelanswersa call
8Enabled at All Times
NONE
P175E 8E DIALLINGPREFIXNUMBER – Enter avalue 1-16digits NONE
P175E 9E PANIC ALARM (FROMKEYPAD) CONTACT-ID REPORTING CODE 120
P175E 10E FIREALARM (FROM KEYPAD) CONTACT-IDREPORTINGCODE 110
P175E 11E
MEDICAL ALARM
(FROM KEYPAD) CONTACT-ID REPORTINGCODE
100
P175E 12E REMOTE TELEPHONEOUTPUT CONTROLPINNUMBER – Entera
1-4 digit PIN (AvailableOnly whenVoiceModule fitted)
0
P175E 13E MICROPHONE ON/OFF (REMOTEVIAMOBILE) COMMAND PIN
NUMBER – Entera 1-4 digit PIN (Available withVoice Module Only)
0
P175E 14E DOMESTIC/VOICE DIAL KISSOFF(REMOTE VIAMOBILE) PIN
NUMBER – Enter a 1-4digitPIN (Runner-8 MUST have Voice Module
fittedtobeabletoKiss-Off)
0
P175E 15E FORCE TEST CALL TOBASE STATION(REMOTE VIAMOBILE) PIN
NUMBER – Enter a 1-4digitPIN (Avail withVoice Module Only) A
Keypad canalsoForce a ‘Test Call’– Press the < Control >& < 0 >
Buttons Together andtheDialler will report a ‘Test Call’.
0
P176E FOR PROGRAMMINGVOICE REPORTING MESSAGES, PLEASE
SEE THE INSTALLATION AND CONFIGGUIDE (RED MANUAL)
TELEPHONENUMBERS
ADDRESS DESCRIPTION DEFAULT NEW
P181E 1-8E TELEPHONENUMBER PROGRAMMING(8 NUMBERS) – Enter a 1-
16 digit phone #
NONE
P62E 1-2E AREAS A& B MONITORING ACCOUNTNUMBER
1=Area A and 2=Area B
A & B =0000
P182E 1-8E TELEPHONENUMBER REPORTINGFORMATS
1 Contact ID
2 Domestic Dial ( Runner-8 requires Voice Module toKiss-OffCall)
3 Pager
4 Speech Dialler (requires 90sec voice module- Part# AHPW16U )
PHONE
NUMBER
1&2 =1CID
PHONE
NUMBER 3-
8 =0
P183E 1-8E TELEPHONENUMBER REPORTINGOPTIONS
1 Stop Dialling ifKissed off
2 MonitorCallProgress
3 Blind Dial
4 Use Group Numbers for ContactID Reporting
5 Stay On-line afterAlarm report fortwo way voice
6 Auto Kiss-off for Voice/Domestic Reporting
7 Use the Dialling Pre-fix
8Isto be used asthe “Call-back” Number (OnlyForTelephone No 8)
PHONE
NUMBER
1&2 =1,2,4
PHONE
NUMBER 3-
8 =1,2
P184E 1-8E MAXIMUM DIAL ATTEMPTS PERTELEPHONENUMBER- Enter a
value 0-99
Ph# 1-8 =3

18
TELEPHONENUMBERS-Cont.
ADDRESS DESCRIPTION DEFAULT NEW
P186E 1-8E DIALLER REPORTINGOPTIONSA
1 Report MainsFailure
2 Report Battery Low
3 Report Radio BatteryLow
4 Report Line Fail
5 Report SystemTamper
6 Report Keypad Tamper
7 Report Zone Tamper
8Report RadioZone Tamper
PHONE
NUMBER 1-
8 =1-8
AllON
P187E 1-8E DIALLER REPORTINGOPTIONSB
1 Report Duress Alarm
2 Report Supervised Radio Alarm
3 Report Zone Sensor-watch Alarm
4 Report ManualPanicAlarm
5 Report ManualFire Alarm
6 Report ManualMedicalAlarm
7 Report Radio Pendant PanicAlarm
8Report Zone Bypasses
PHONE
NUMBER 1-
8 =1-8
AllON
P188E 1-8E DIALLER REPORTINGOPTIONSC
1 Report Arm/Disarm
2 Report StayMode Arm/Disarm
3 Report Disarmonly after an Activation
4 Report StayMode Disarmonly after anActivation
5 Report StayMode Zone Alarms
6 Report Access to ProgramMode
7 Report 24 Hour Alarmsif Domestic/Voice mode set
8Report Zone Restores
PHONE
NUMBER 1-2
=1,2,3,4,5,7,8
PHONE
NUMBER 3-8
=5,7,8
P189E 1-8E DIALLER REPORTINGOPTIONSD
1 Report Latchkey Disarm
2 Report Delinquent
3 Report Tests
4 Report Fuse Failure
5 Report Output 1 or2 Fail
6 Report RTC (RealTime Clock)Timechanged
7 Report Keypad Buss Trouble
8Report RFInterference (Jamming) Detected
PHONE
NUMBER 1-
2 =3,4,5
PHONE
NUMBER 3-
8 =4,5
P192E 1-2E DIVERT AREAEVENTS– 1=Area A,2 =Area B
1 Dial on away arm
2 Dial on away disarm
3 Dial on stay arm
4 Dial on stay disarm
5 Dial if Key-switch activation
6 Dial if Timezone activation
7 Dial if DTMF orPC activation
8Dial if keypad ARM orSTAY single button activation
NONE
P193E FOR PHONEDIVERSION OPTIONS CHECK THE INSTALLATION &
CONFIGURATIONGUIDE
NONE
P196E FOR SIAREPORTINGOPTIONS CHECK THEINSTALLATION &
CONFIGURATIONGUIDE

19
PANEL DIAGNOSTICS & DEFAULTINGOPTIONS
ADDRESS DESCRIPTION DEFAULT NEW
P200E 1E DISPLAY PANEL SOFTWARE VERSION NUMBER
P200E 2E DISPLAY KEYPAD ADDRESS NUMBER
P200E 3E DISPLAY AREASASSIGNED TO THIS KEYPAD DisplaysAreas
Assigned to thisKeypad
P200E 4E DISPLAY ACTIVE TIME ZONES
P200E 5E DISPLAY BATTERYVOLTAGE
P200E 6E WALK TESTMODE
P200E 7E WRITETOEEPROM(DTU/Memory Key) BOARD (EEPROM
(DTU/Memory Key) Must be set to‘write’ enable)
P200E 8E READ FROM EEPROM (DTU/Memory Key) BOARD
P200E 9E RESTORE USER& INSTALLERCODES+TELEPHONE NUMBERS
TODEFAULTS
P200E 10E RESTORE ALL FACTORY DEFAULTS
P200E 11E CLEAR ALARM MEMORY BUFFER
P200E 12E INITIATEACALL TO THE CALL-BACK
P200E 13E INSTALLERMODE ENTRY - (if Option-2 in 25E 10E (Installer
Direct Access) isOff, then to get into InstallersMode, you
Must first enter Client (Master-CodeUser Prog)modeandgo
to P200E 13E andenter the InstallersCode).
P200E 14E RSSI –In this mode, the controlpanel keypad willdisplay the RSSI
(Signal)Strength Level ofwireless detectorsand remotes. Must have
the 9F (916MHz)Freewave Receiver Ver:3.8+and LCD Keypad
Ver:2.10+

20
Connection Diagram:
RUNNER-8
Runner –8
The Runner-8board is suppliedin the Standard MINIHousing:
qStandard MINI-housing (with Front Screws for cover & space for 12V 7AH Bat).
Battery Spec.: SealedLead-AcidRechargeableBattery12V/1.3Ahupto12V/7Ah intheMiniandPW-housings.
Battery Cutoff Level: (WhenACmainsfails):10±0.3V
(*WARNING: ExposingtheControl PaneltoHighTemperatures(above50° Csuch as wheninstalledintheroof)
mayDamagetheControlPanelandcauseErraticPerformance. SuchDamageisconsideredAbuseand/orMisuse
that may voidWarranty).
Z5 Z6
16VAC 1.5A
Plug Pack
RUNNER
-
8
V9.08AL
1009
EOLResistorOptionshownasType-15(Zone
DoubledwithoutTamper)=4k7 forLow-Zones
(i.e.:Zones1-4)and8k2forHi-Zones(i.e.:
Zones5-8).See P125E (Pg-12)ofthismanual
forlistofEOLResistorsthatcanbeselected.
Panel Tamper2k2EOLResistor Optionshown.
Unless advisedotherwise,this2k2 isfactory
fittedtothePanelTamperSwitch Wire(under
theblackHeat Shrinkthatcovers the
end ofthe
TamperSwitchWire).
Standard MINI-housing
This manual suits for next models
2
Table of contents
Other Crow Control Panel manuals

Crow
Crow PowerWave - 64 Operating instructions

Crow
Crow PowerWave 8 User manual

Crow
Crow Runner Series Operator's manual

Crow
Crow Power Wave - 8 User manual

Crow
Crow Runner Series User manual

Crow
Crow RUNNER 8/64 Operating instructions

Crow
Crow Serenity Series User manual

Crow
Crow PowerWave-16 Installation guide

Crow
Crow Runner Series Operator's manual

Crow
Crow Arrowhead Elite V6 Operating instructions