7700 MultiFrame Manual
7707AT Multi-Channel AES Fiber Transmitter
Revision 1.0 7707AT-13
AT-8U 1v1_b53
AT-16 1v1_b82
Table 2: Firmware for simultaneous local and remote control
Note: If the firmware does not support both control types, the CONTROL jumper allows
selection of either remote or local control. The corresponding CONTROL LED
will be lit when the card is under VistaLINKTM control.
5.3. CONFIGURING THE MODULE FOR FIRMWARE UPGRADES
RUN/UPGRADE The RUN/UPGRADE jumper is used when firmware upgrades are being done to the
module. For normal operation it should be installed in the RUN position. See the Upgrading
Firmware chapter in the front of the binder for more information.
To upgrade the firmware in the module unit pull it out of the frame. Move the RUN/UPGRADE
jumper J16 into the UPGRADE position. Install the Upgrade cable provided (located in the
vinyl pouch in the front of the binder) onto SERIAL header J27 at the card edge. Re-install the
module into the frame. Run the upgrade as described in Upgrading Firmware chapter in the
front of the binder. Once the upgrade is completed, remove the module from the frame, move
J16 into the RUN position, remove the upgrade cable and re-install the module. The module is
now ready for normal operation.
6. VISTALINK™ REMOTE MONITORING/CONTROL
6.1. WHAT IS VISTALINK™?
VistaLINK™ is Evertz’s remote monitoring and control capability over an Ethernet network using Simple
Network Management Protocol (SNMP). SNMP is a standard computer network protocol that enables
different devices sharing the same network to communicate with each other. For monitoring, there needs
to be a detecting device that automatically reports all errors to a central alarm and error logging station.
We also need to be able to interrogate individual detector devices from the central station to determine the
status of individual channels. Finally, we need to be able to configure devices in the network from the
central station and receive feedback that the configuration has been carried out.
There are 3 components of SNMP:
1. An SNMP manager also known as a Network Management System (NMS) is a computer running
special software that communicates with the devices in the network. Evertz VL-Fiber demo Manager
graphical user interface (GUI), third party or custom manager software may be used to monitor and
control Evertz VistaLINK™ enabled fiber optic products.
2. Managed devices (such as 7707AT cards), each with a unique address (OID), communicate with the
NMS through an SNMP Agent. Evertz VistaLINK™ enabled 7700 series modules reside in the 3RU
7700FR-C MultiFrame and communicate with the manager via the 7700FC VistaLINK™ frame
controller module, which serves as the Agent.
3. A virtual database known as the Management information Base (MIB) lists all the variables being
monitored and which both the Manager and Agent understand. Please contact Evertz for further
information about obtaining a copy of the MIB for interfacing to a third party Manager/NMS.