9
MANUGENEX7xx - Version 2.12
© 2018-2022 EXOR International S.p.A. - Subject to change without notice
3 Technical Specications
Electromagnetic Compatibility (EMC)
Radiated disturbance test Class A CISPR 22
CISPR 16-2-3
Electrostatic discharge immunity test 8 kV (air electrostatic discharge) EN 61000-4-2
4 kV (contact electrostatic discharge)
Radiated, radio-frequency, 80 MHz ÷ 1 GHz, 10V/m EN 61000-4-3
electromagnetic eld immunity test 1,4 GHz ÷ 2 GHz, 3 V/m
2 GHz ÷ 2.7 GHz, 1 V/m
Burst immunity test ± 2 KV dc power port EN 61000-4-4
± 1 KV signal line
Surge immunity test ± 0,5 KV dc power port (line to earth) EN 61000-4-5
± 0,5 KV dc power port (line to line)
± 1 KV signal line (line to earth)
Immunity to conducted disturbances
inducted by radiofrequency eld 0.15 ÷ 80 MHz, 10V EN 61000-4-6
Power frequency magnetic eld
immunity test Enclosure, 50/60Hz, 30A/m EN 61000-4-8
Environmental conditions
Operating temperature (surrounding -20 ÷ +60°C (vertical installation) EN 60068-2-14
air temperature) Plug-in modules and USB devices
may limit max temperature to +50°C
Storage temperature -20 ÷ +70°C EN 60068-2-1
EN 60068-2-2
EN 60068-2-14
Operating and storage humidity 5 ÷ 85 % RH not-condensing EN 60068-2-30
Vibrations 5 ÷ 9 Hz, 7 mm p-p EN 60068-2-6
9 ÷ 150 Hz, 1 g
Shock ± 50 g, 11 ms, 3 pulses per axis EN 60068-2-27
Protection class Front panel IP66, Rear IP20 EN 60529
Touchscreen technology Projected capacitive
Back-up battery 3V 50mAh Lithium, rechargeable, not user-replaceable,
model VL2330.
Fuse Automatic
Serial Port RS-232, RS-485, RS-422 software congurable
Flash 4GB for eX705, eX707, eX710, eX707G, eX710G,
8GB for eX712, eX715, eX721
RAM 512MB for eX705, 1GB for eX707, eX710, eX707G, eX710G,
2GB for eX712, eX715, eX721
Hardware clock Clock/Calendar with back-up battery
Accuracy RTC (at 25°C) <100ppm