Safety
1.2 Safety instructions
àThe mandatory installation, maintenance and repair work must be performed by properly trained personnel
authorised by GEZE.
àThe country-specic laws and regulations are to be observed during safety-related tests.
àGEZE is not liable for any injuries or damage whatsoever resulting from unauthorised changes to the system.
àGEZE is not liable if products from other manufacturers are used with GEZE equipment.
àFurthermore, only original GEZE parts may be used for repair and maintenance work.
àThe connection to the power supply must be made by a professional electrician. Perform the power connec-
tion and equipment earth conductor test in accordance with VDE 0100 Part 610.
àUse a customer-accessible 10-A overload cut-out as the line-side disconnecting device.
àIn compliance with Machinery Directive (2006/42/EC), a risk analysis must be performed and the door system
identied in accordance with CE Marking Directive 93/68/EEC before the door system is commissioned.
àObserve the latest versions of guidelines, standards and country-specic regulations, in particular:
àASR A1.7 "Guidelines for doors and gates"
àDIN 18650 "Building hardware – Automatic door systems"
àAccident-prevention regulations, especially BGV A1 "General regulations" and BGV A2 "Electrical systems
and equipment"
àVDE 0100; Part 610 "Erection of low-voltage installations"
àDIN EN 60335-2-103 "Safety of electrical devices for home use and similar purposes; special requirements
for drives for gates, doors and windows"
àThe relevant regional building regulations must be consulted with regard to widths of escape routes.
1.3 Safety conscious working
àSecure workplace against unauthorised entry.
àUse only cables prescribed in the cable plan provided. Lay shields in accordance with the wiring diagram.
àSecure loose, internal drive cables with cable ties.
àBefore working on the electrical system:
àDisconnect the drive from the 230 V mains and check to ensure that it is not supplied with power.
àDisconnect the control unit from the 24 V battery.
àNote that if an uninterruptible power supply (UPS) is used, the system will still be supplied with power
despite the fact that the power supply is disconnected.
àAlways use insulated wire-end ferrules for wire cores.
àAttach safety stickers to glass door leaves.
àDanger of injury by broken glass!
àDanger of injury due to sharp edges in the drive!
1.4 Inspection of the installed system
Measures for security and prevention of pinching, impact, shearing or drawing-in spots:
àCheck the functioning of safety sensors and movement detectors.
àThe detection eld of the movement detector in the direction of the emergency exit must cover the opening
width x 1.5 m in front of the door.
àCheck protective earth connection to all metal parts that can be touched.
àPerform a safety analysis (risk analysis).
1.5 Environmentally conscious working
àWhen disposing of the door system, separate the dierent materials and have them recycled.
àDo not dispose of batteries and storage cells with household waste.
àComply with the statutory regulations when disposing of the door system and the batteries/rechargeable bat-
teries.