KLCM412P
Plug-in supply (Integrated emergency test, RJ45 Link)
KLCM413W
Wire-in supply (Integrated emergency test, RJ45 Link)
KLCM423WIET
Wire-in supply, emergency test (Standard emergency test, supply disconnect)
For KLCM how-to guides please see hager.co.uk or our YouTube channel
youtube.com/user/hageruktv.
Search ‘Hager Klik LCM’ for our video quick start guide.
Mounting Options
Supply Connection
Drop Rods Direct: e.g. nail gun or screw xing
(not possible for hard-wire KLCM413W)
Trunking
(Use slider along spring channel nuts.)
Hard wired - KLCM413W & WIET
Neutral
Line
CPC
Do not use
Do not use
Emergency connection to be
used for KLCM413WIET only.
Pluggable - KLCM412P
Plug in supply & Klik 7 Lead Connection
16A
LOCKED
16A
LOCKED
16A
LOCKED
16A
LOCKED
16A
LOCKED
PRE
SS
RELEASE
RELEASE
RELE
ASE
16A
LOCKED
PRESS
16A
LOCKED
16A
LOCKED
16A
LOCKED
PRESS
• Connecting the supply lead: plug
in and push down
• Disconnecting the supply lead:
press button and push up.
Plug colour coding
White: Luminaire Lead
Red: Luminaire & Emergency
Black: Link Lead
Search KlikLink in the iPad app store.
Klik LCM
Installation Instructions
GB
1ZD0782 - Issue 3 10-17
ZD0782ZD0782
Hager Ltd.
Hortonwood 50
Telford
Shropshire
TF1 7FT
Sales Service Centre: 01952 675 675
Technical Service Centre: 01952 675 689
Hager hereby declares that this KLCM**** is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.
A copy of the original declaration of conformity may be obtained from technical@hager.co.uk.
Technical Characteristics
Number of channels 4
Number of outputs per channel 3 (hard wired LCM has 4 outputs on channel A)
Number of sensor inputs 4 (KLCM-OS range)
Number of switch inputs 4
Supply Voltage 230V AC 50Hz
Maximum Number of Devices 64 DALI, 16 per output.
Rated current 10A (total load)
Rated current each connector 10A
Complies with BS 5733:2010,
FprEN60669-2-5
BS EN 61535:2009 - (Excluding clauses 10.1 and 10.3 due to Aluminium enclosure)
IP protection IP20
Connection for commissioning Bluetooth Smart (Bluetooth 4) (only available for apple iPad)
Dimensions Height Width Depth Weight
145mm 440mm 58mm 1.9kg
Brown/White On
Blue/White Off
Brown 0V (Common)
Supply input connection
x4 Max
x4 Max
KLCM-OS 1 Head Sensor (inc 10m RJ11)
KLCM-3OS 3 Head Sensor (corridor sensor, inc 10m RJ11)
KLCM-5OS 5 Head Sensor (wide area sensor, inc 10m RJ11)
KLO*RJ45G RJ45 Switch Drop (plug-to-plug), Grey
KLO*RJ45R RJ45 Link lead (plug-to-plug), Red
KLORJ45CON RJ45 Splitter
*5, 10, 15, 20, 30, 40, 50
Hager strongly recommends the use of Hager
supplied RJ54 cables for all installations. All
Hager leads are tested prior to shipment. If
other manufacturers RJ45 cables are used
we recommend that each lead is tested with
a dedicated RJ45 tester prior to installation.
Should Hager be called to site to support the
installation and a fault is found with the RJ45 cables, then a
charge for site support will be incurred.
Partition switching
For partition switching please use switch input 1 only.
Sollysta Wiring Accessories for use with Klik
Klik LCM Control Connection
WMGS13R 2 way & centre off retractive switch module, on/off, dim up/down
WMGS12 20A, 2 way, single pole switch
WMGKS 20A, double pole keyswitch for emergency override
WMGP*(1, 2, 3, 4, 6, 8) White moulded, grid switch cover plates
WMGP*(1, 2, 3, 4, 6, 8)G Grey moulded (Part M), grid switch cover plates
WMGF*(1, 2 & 34) Grid frames, 1, 2 and 3/4 gang
Decorative nishes also available for grid products, see Hager catalogue.
Scene control plates, brushed steel, are available on request, 4 scenes, on/dim up, off/dim down.
Standard Switch Drop
Default operation on power up (pre-commissioning)
Switch inputs - 1 to 4 on KLCM Emergency test, override, corridor hold, in & out.
(KLCM413WIET, emergency test not applicable)
COM LOOP
N
L1 L2
Orange/White
Orange
Green/White
Blue
Blue/White
Green
Brown
Brown/White
Override - All Outputs On
Override - All Outputs Off
Corridor Hold Line
Emergency Test (Timer 1)
Emergency Test (Timer 2)
Emergency Test (Timer 3)
Common
Not Used.
WMGS13R - 20A, 2 way, centre off retractive grid switch - white
For the latest range information or assistance call our sales service centre on 01952 675 675 or technical service centre on 01952 675 689 or hager.co.uk
The default settings on power up of the LCM is Presence with a 20 minute time out. Therefore any lights connected will not come on (to prevent a building being
lit 24/7).
To enable any light plugged in to the LCM to come on prior to nal commissioning (i.e. during other building works) we recommend temporarily connecting a
KLCM-OS. This will enable all lights to come on for 20 minutes unless the sensor is triggered, this also reduces the requirement to power off LCM at night and
could also aid building security during construction or renovation works.
RJ45 Link Lead RJ45 Link Lead
RJ45 Link Lead
Klik LCM
Installation Instructions
2ZD0782 - Issue 3 10-17
ZD0782 ZD0782

Other hager Control Unit manuals

hager TYA606 Series User manual

hager

hager TYA606 Series User manual

hager TYA610A User manual

hager

hager TYA610A User manual

hager TN002 User manual

hager

hager TN002 User manual

hager WK305 User manual

hager

hager WK305 User manual

hager RCBO-AFDD User manual

hager

hager RCBO-AFDD User manual

hager JK11254D Manual

hager

hager JK11254D Manual

hager RTN100X User manual

hager

hager RTN100X User manual

hager TXA101 User manual

hager

hager TXA101 User manual

hager Vega D FD Series User manual

hager

hager Vega D FD Series User manual

hager TYB621C User manual

hager

hager TYB621C User manual

hager TK 301 User manual

hager

hager TK 301 User manual

hager TYM632C User manual

hager

hager TYM632C User manual

hager TYF61 Series User manual

hager

hager TYF61 Series User manual

hager TRB221A-5A User manual

hager

hager TRB221A-5A User manual

hager H3 x250 User manual

hager

hager H3 x250 User manual

hager RTN710X User manual

hager

hager RTN710X User manual

hager RE 410 Series User manual

hager

hager RE 410 Series User manual

hager RE 310 Series User manual

hager

hager RE 310 Series User manual

hager ZZ45WAN2PP User manual

hager

hager ZZ45WAN2PP User manual

hager h3 h400 User manual

hager

hager h3 h400 User manual

hager TYA606A User manual

hager

hager TYA606A User manual

hager tebis TX100 User manual

hager

hager tebis TX100 User manual

hager NH00 User manual

hager

hager NH00 User manual

hager TN002S User manual

hager

hager TN002S User manual

Popular Control Unit manuals by other brands

Surface Concept HVPS-HC manual

Surface Concept

Surface Concept HVPS-HC manual

olympia electronics BS-464 manual

olympia electronics

olympia electronics BS-464 manual

Bed-Check Classic-Check Quick programming guide

Bed-Check

Bed-Check Classic-Check Quick programming guide

Bosch Professional GCY 42 Original instructions

Bosch

Bosch Professional GCY 42 Original instructions

Betts ES22PP-AABN Installation and maintenance manual

Betts

Betts ES22PP-AABN Installation and maintenance manual

Lintec CV-1000 Series instruction manual

Lintec

Lintec CV-1000 Series instruction manual

Cavli Wireless C16QS Hardware manual

Cavli Wireless

Cavli Wireless C16QS Hardware manual

White Rodgers 47D43-811 installation instructions

White Rodgers

White Rodgers 47D43-811 installation instructions

UNICORECOMM UM220-IV M0 Installation and Operation User Manual

UNICORECOMM

UNICORECOMM UM220-IV M0 Installation and Operation User Manual

Monacor ATT-212/WS manual

Monacor

Monacor ATT-212/WS manual

M-system R3-NF1 instruction manual

M-system

M-system R3-NF1 instruction manual

G&D RemoteAccess-IP-CPU installation guide

G&D

G&D RemoteAccess-IP-CPU installation guide

Casablanca W-18 Operation manual

Casablanca

Casablanca W-18 Operation manual

Xylem McDonnell & Miller RB-24E instruction manual

Xylem

Xylem McDonnell & Miller RB-24E instruction manual

Huawei APM30H user guide

Huawei

Huawei APM30H user guide

Texas Instruments WiLink WL 1MOD Series manual

Texas Instruments

Texas Instruments WiLink WL 1MOD Series manual

Freenove ESP32-S3 manual

Freenove

Freenove ESP32-S3 manual

Reliable Enviromate E3 Instructions for installation, operation care and maintenance

Reliable

Reliable Enviromate E3 Instructions for installation, operation care and maintenance

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.