manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Hameg
  6. •
  7. Test Equipment
  8. •
  9. Hameg HM303-6 User manual

Hameg HM303-6 User manual

Other manuals for HM303-6

2

Other Hameg Test Equipment manuals

Hameg HM 103-2 User manual

Hameg

Hameg HM 103-2 User manual

Hameg HM1004 User manual

Hameg

Hameg HM1004 User manual

Hameg HM1507-3 User manual

Hameg

Hameg HM1507-3 User manual

Hameg CombiScope HM2008 User manual

Hameg

Hameg CombiScope HM2008 User manual

Hameg HM 407A User manual

Hameg

Hameg HM 407A User manual

Hameg HM303-6 User manual

Hameg

Hameg HM303-6 User manual

Hameg HMO3000 Series Installation guide

Hameg

Hameg HMO3000 Series Installation guide

Hameg HM 204 User manual

Hameg

Hameg HM 204 User manual

Hameg HM 604 User manual

Hameg

Hameg HM 604 User manual

Hameg HM 1004-3.01 User manual

Hameg

Hameg HM 1004-3.01 User manual

Hameg HM6050-2 User manual

Hameg

Hameg HM6050-2 User manual

Hameg HM304 User manual

Hameg

Hameg HM304 User manual

Hameg HMO Series User manual

Hameg

Hameg HMO Series User manual

Hameg HM 1004-3 Series User manual

Hameg

Hameg HM 1004-3 Series User manual

Hameg HM 303-4 User manual

Hameg

Hameg HM 303-4 User manual

Hameg HM1507-3 User manual

Hameg

Hameg HM1507-3 User manual

Hameg HM 303-4 User manual

Hameg

Hameg HM 303-4 User manual

Hameg HM 1007 User manual

Hameg

Hameg HM 1007 User manual

Hameg HM 203-7 User manual

Hameg

Hameg HM 203-7 User manual

Hameg HM507 User manual

Hameg

Hameg HM507 User manual

Hameg HM 303-5 User manual

Hameg

Hameg HM 303-5 User manual

Hameg HM204-2 User manual

Hameg

Hameg HM204-2 User manual

Hameg HM 2005 User manual

Hameg

Hameg HM 2005 User manual

Hameg HM504-2 User manual

Hameg

Hameg HM504-2 User manual

Popular Test Equipment manuals by other brands

Ambit P.F. Series instruction manual

Ambit

Ambit P.F. Series instruction manual

Megger BMM500 Series user guide

Megger

Megger BMM500 Series user guide

RJG Lynx Sensor Tester operating instructions

RJG

RJG Lynx Sensor Tester operating instructions

Mark-10 TT02 Series user guide

Mark-10

Mark-10 TT02 Series user guide

Martel 3001 Operator's manual

Martel

Martel 3001 Operator's manual

ElproSys DiagProg4 instruction manual

ElproSys

ElproSys DiagProg4 instruction manual

Redtech TRAILERteck T05 user manual

Redtech

Redtech TRAILERteck T05 user manual

Venmar AVS Constructo 1.0 HRV user guide

Venmar

Venmar AVS Constructo 1.0 HRV user guide

Test Instrument Solutions SafetyPAT operating manual

Test Instrument Solutions

Test Instrument Solutions SafetyPAT operating manual

Hanna Instruments HI 38078 instruction manual

Hanna Instruments

Hanna Instruments HI 38078 instruction manual

Kistler 5495C Series instruction manual

Kistler

Kistler 5495C Series instruction manual

Waygate Technologies DM5E Basic quick start guide

Waygate Technologies

Waygate Technologies DM5E Basic quick start guide

StoneL DeviceNet CK464002A manual

StoneL

StoneL DeviceNet CK464002A manual

Seica RAPID 220 Site preparation guide

Seica

Seica RAPID 220 Site preparation guide

Kingfisher KI7400 Series Training manual

Kingfisher

Kingfisher KI7400 Series Training manual

Kurth Electronic CCTS-03 operating manual

Kurth Electronic

Kurth Electronic CCTS-03 operating manual

SMART KANAAD SBT XTREME 3G Series user manual

SMART

SMART KANAAD SBT XTREME 3G Series user manual

Agilent Technologies BERT Serial Getting started

Agilent Technologies

Agilent Technologies BERT Serial Getting started

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

2 Channels with deflection coefficients of 1mV/cm – 20 V/cm
Time Base: 0.2 s/cm – 100 ns/cm,
with X Magnification to 10 ns/cm
Low Noise Measuring Amplifiers with high pulse fidelity
and minimum overshoot
Triggering from 0 to 50 MHz from 5 mm signal level
(up to 100 MHz from 8 mm)
Up to 500,000 signal displays per second
in optimum analog quality
Yt, XY and component-test modes
35 MHz Analog Oscilloscope
HM303-6
HM303-6
Full screen display of
35 MHz sine wave signal
Line triggered composite
video signal
No signal distortion
resulting from overshoot
HM303-6E/140408/ce · Subject to alterations · © HAMEG Instruments GmbH · ® Registered Trademark · DQS-certified in accordance with DIN EN ISO 9001:2000, Reg.-No.: DE-071040 QM
HAMEG Instruments GmbH · Industriestr. 6 · D-63533 Mainhausen · Tel +49 (0) 6182 800 0 · Fax +49 (0) 6182 800 100 · www.hameg.com · info@hameg.com
A Rohde & Schwarz Company
www.hameg.com
35 MHz Analog Oscilloscope HM303-6
Valid at 23 °C after a 30 minute warm-up period
Vertical Deflection
Operating Modes: Channel I or II only
Channels I and II (alternate or chopped)
Sum or Difference of CH I and CH II
Invert: CH II
XY Mode: via CH I (X) and CH II (Y)
Bandwidth: 2 x 0 to 35 MHz (-3 dB)
Rise Time: ‹10ns
Deflection Coefficients: 1-2-5 Sequence
1 mV/div. – 2 mV/div.: ± 5 % (Bandwidth 0 – 10 MHz (-3 dB))
5 mV/div. – 20 V/div.: ± 3 % (Bandwidth 0 – 35 MHz (-3 dB))
Variable (uncalibrated): › 2.5 : 1 to › 50 V/div.
Input Impedance: 1 MΩ II 20 pF
Input Coupling: DC, AC, GND (ground)
Max. Input Voltage: 400 V (DC + peak AC)
Triggering
Automatic (Peak to Peak): 20 Hz – 50 MHz (≥5 mm)
50 MHz – 100 MHz (≥8 mm)
Normal with Level Control: 0 – 50 MHz (≥5 mm)
50 MHz – 100 MHz (≥8 mm)
Trigger Indicator: LED
Slope: positive or negative
Sources: Channel I or II, CH I / CH II alternate
(≥8 mm), Line and External
Coupling: AC: 10 Hz – 100 MHz
DC: 0 – 100 MHz
LF: 0 – 1.5 kHz
Trigger Indicator: LED
External Trigger Signal: ≥0.3 Vpp (30 Hz – 50 MHz)
Active TV sync. separator: pos. and neg.
Horizontal Deflection
Time Base: 0.2 s/div. – 0.1 μs/div. (1-2-5 Sequence)
Accuracy: ±3%
Variabel (uncalibrated): › 2.5:1 to › 0.5 s/div.
X Magnification x 10: up to 10 ns/div.
Accuracy: ± 5 %
Hold-Off Time: variable to approx. 10 : 1
XY
Bandwidth X Amplifier: 0 – 2.5 MHz (-3 dB)
XY Phase shift ‹ 3°: ‹ 120 kHz
Component Tester
Test Voltage: approx. 7 Vrms (open circuit)
Test Current: max. 7 mArms (short-circuit)
Test Frequency: approx. 50 Hz
Test Connection: 2 banana jacks 4 mm Ø
One test circuit lead is grounded via protective earth (PE)
Miscellaneous
CRT: D14-363GY, 8 x 10 cm with internal graticule
Acceleration Voltage: approx. 2 kV
Trace Rotation: adjustable on front panel
Calibrator Signal (Square Wave): 0.2 V ± 1 %, ≈ 1 kHz/1 MHz (tr ‹ 4 ns)
Power Supply (Mains): 105 – 253 V, 50/60 Hz ± 10 %, CAT II
Power Consumption: approx. 36 Watt at 230 V/50 Hz
Ambient temperature: 0 °C...+ 40 °C
Safety class: Safety class I (EN61010-1)
Weight: approx. 5.4 kg
Dimensions (W x H x D): 285 x 125 x 380 mm
Accessories supplied: Line Cord, operator’s manual, 2 Probes 1:1 / 10:1 (HZ154)