5. Calibrations
Calibrations for speed-sensor and motor-sensor have to be done before the system can work
correctly.
5.1 Speed-sensor
Calibration value for the speed sensor is in mm per pulse.
Example: If you have 430 mm between two pulses, the display value for the calibration-value
should be 430 (no decimal).
1. Set the display value to km/h.
2. Press the SET button for 2 second, this will activate the calibration function.
3. The display is now showing the calibration value (the display is flashing). The
calibration value is millimetre/speed-pulse [mm/speed-pulse]-[maximum 500 mm].
4. Press SET and drive a known length, example 100 metres, the display will show you
how far you have driven with the current calibration value in metres [m].
5. If the display is showing you the wrong driven length, change the length by pressing
up or down. It will show you the length in metres, with one decimal.
6. Press SET when the value is the same as the length you have driven.
7. The current and changed calibration value will be displayed.
8. Accept this value by pressing SET button again, this will finish the calibration
procedure.
9. You can always abort a current calibration by pressing the RESET button.
5.1 Motor-sensor
1. Set the display value to kg tot.
2. Press the SET button for 2 seconds, this will activate the calibration function.
3. The display is now showing the calibration value (the display is flashing). The
calibration value is in gram-by-pulse [set gram/motor pulse to 1,00].
4. Press SET and to activate the motor feeding.
Note! The ON/Auto-switch must be in off-mode when entering this new state, else the
ON-led will flash telling you to turn of the switch.
5. The motor can now be turn on by switching the motor-switch to ON.
6. Feed out seed for measurement, the display will show you the value of the outputted
seed with the current calibration value in kilograms [kg].
7. Measure the seed you have put out, and adjust the value on the display with the up and
down button. The value is showed in kilogram, with three decimal.
8. Accept this value by pressing SET button.
9. The now corrected calibration value will be displayed. Press SET to accept this value,
this will finish the calibration procedure.
10. You can always abort a current calibration by pressing the RESET button.