www.insigniarange.com Last Modied:27/01/2017
INSTALLATION MANUAL
GT9014
ATTENTION INSTALLERS:
These instrucons must be
le with the customer
30 Day Technical Support: 01908 226545
(NOTE: This service is only available to customers from the day of delivery,
please have your supplier’s details and your postcode to hand before calling)
Email: [email protected]
Replacements Parts: inside of your warranty contact:
www.insigniarange.co.uk/customerService.aspx
Spares/Replacements Parts: outside of your warranty
contact 0844 800 3069
www.insigniarange.co.uk
WARRANTY REG NO: __________________________
to claim your full 5 year warranty, register your shower within 90 days at: www.insigniarange.co.uk/warrantyreg.aspx
CHECK ALL CONTENTS BEFORE BUILD COMMENCES. NO RETURNS CAN BE MADE
ONCE THE BUILD HAS STARTED AS IT IS DEEMED ACCEPTANCE OF PRODUCT!
www.insigniarange.com Last Modied:27/01/2017
02
Contents
Introduction
Electrical Requirements
What’s In The Boxes?
Screw Pack Contents
Plumbing Requirements
Schematics
Starting The Installation
Electric Box Connections
Sealing and Water Testing
Control Panel Instructions
Help Book Information
Parts List
3
5
7
8
9
10
11
18
19
20
21
22
www.insigniarange.com Last Modied:27/01/2017
03
Thank you for your recent purchase of an Insignia shower. Please read this booklet with great care to ensure you get the best out of your build and have a shower that
will last for many years to come!
Like everything, in order to obtain a first class product that will serve you well for many years, the effort and correctness put into the assembly will reflect in the quality of
your finish.
OUR BADGE RATING IN TERMS OF DIFFICULTY OF ASSEMBLY IS BASED ON CLIENT FEEDBACK
1 Badge = Very easy
2 Badges = Easy
3 Badges = Moderate
4 Badges = Harder than average
5 Badges = Professional skills required
This shower is rated 3 Badges
www.insigniarange.com Last Modied:27/01/2017
04
ASSEMBLY AND PLUMBING
THIS PRODUCT BUILD IS RATED SUITABLE FOR DIY PURPOSES PROVIDING THE CUSTOMER IS OF ABOVE AVERAGE SKILL AND FEELS CONFIDENT IN
THEIR ABILITY. ONLY YOU THE CUSTOMER WILL KNOW THIS SO BEFORE ANY ATTEMPT IS MADE TO ASSEMBLE, READ THROUGH THE FOLLOWING
PAGES IN DETAIL THEN DECIDE. IF YOU HAVE ANY DOUBT USE THE SERVICES OF A PROFESSIONAL. IN PICKING SUCH, ALLOW THEM TO DECIDE IF
THEY ARE CAPABLE OF BUILD BY FIRST SHOWING THESE INSTRUCTIONS TO THEM. ALWAYS GET THREE QUOTES.
REMEMBER THE BEST IS NOT ALWAYS THE CHEAPEST!
REMEMBER PLUMBERS PLUMB! 90% OF THIS JOB IS NOT PLUMBING!
DUE TO THE NATURE OF THIS PRODUCT WE HIGHLY ADVISE THE PURCHASE AND FITTING OF A WATER SOFTENER
(PLEASE NOTE LIMESCALE BUILD UP MAY CAUSE DAMAGE TO YOUR SHOWER AND WILL NOT BE COVERED UNDER WARRANTY)
ELECTRICAL CONNECTION TO HOUSE MAINS
WHEN YOUR ITEM IS ASSEMBLED ALWAYS USE THE SERVICES OF A FULLY QUALIFIED ELECTRICAN COMPANY TO COMPLETE THE CONNECTION FROM
SHOWER TO THE HOUSE SUPPLY. LAWS DEMAND IN MANY CASES YOU DO THIS AND YOUR WARRANTY IS VOID IN REGARDS TO THE ELECTRICAL
ITEMS IF THIS IS NOT UNDERTAKEN.
YOURS AND OTHERS SAFETY IS PARAMOUNT. NEVER ATTEMPT THIS YOURSELF!
REMEMBER:
These showers are designed to be free standing and movable from their location should you have the need to replace anything. ALWAYS USE Flexible braided water
inlet pipes (not supplied) at least a metre long (not central heating plastic type!)
Always use a flexible waste pipe from your house supply to the shower .
NEVER FIX with rigid pipes, NEVER FIX the unit to the wall.
DURING BUILD, LIKE ALL SHOWERS CORRECT SEALING IS IMPERATIVE.
ATTENTION
ALWAYS FIT EASY TO GET TO ISOLATION TAPS ON BOTH THE HOT AND COLD WATER SUPPLY (NOT SUPPLIED). JUST LIKE A
DISHWASHER OR WASHING MACHINE, THIS PRODUCT MUST BE ISOLATED WHEN NOT IN USE.
FLEXIBLE SUPPLY HOSES (NOT SUPPLIED) COUPLE HERE AS ORIGIN OF SUPPLY
www.insigniarange.com Last Modied:27/01/2017
05
TOTAL ELECTRICAL REQUIREMENTS
Voltage Rating 220 -240AC
Frequency Rating 50HZ
Power Rating 2.8KW
Your electrical contractor should understand ALL legal requirements of connection before undertaking any work or installation.
UNDER NO CIRCUMSTANCES UNDERTAKE THIS YOURSELF!!!
Note for electrician. This product comes with 13 amp plug(s) fitted with an RCD unit. We leave it this way for you to connect this your own way
due to continued additions to current regulations. As at October 2010 we offered two methods.
1) Connect within current laws and IP directives using plug and RCD provided with steam version or supply one for non steam version
2) (Preferred) Wire into isolated fused feed connecting directly to the house consumer/service box. Remove the fitted plug and ensure the
Consumer unit has capabilities to replace RCD feature if RCD is removed.
Always use protection against electrical surge. Your shower should be treated the same as a home computer. A surge protector should
eradicate the possibility of either the transformer or computer control being burnt out. Please note earth is required and found on chassis of
shower tray. A further earth is required from Steam Generator unit. Each earth must ground through power supply line.
www.insigniarange.com Last Modied:27/01/2017
06
Tool Requirements
None Supplied
Scissors Stanley Blade Silicone Gun Spirit Level Tape Measure Philips Screwdriver Electric Drill
Adhesive Requirements
Bacteria Resistant Sanitary Silicone - (for vertical joints) RubberGum Plumbers Mait (for waste joints)
Not Supplied Not Supplied
Not Supplied
Hardware Requirements
A Hydro-Massage Shower requires 2 x 1 Metre Braided Hose
Not Supplied
www.insigniarange.com Last Modied:27/01/2017
07
Whilst the next steps show you how to assemble your shower we want to make sure you have a correct build to ensure you get a trouble free shower. Therefore our advice
is to follow the instructions and perform a dry run to ensure you are confident with the build and you understand fully how the unit is assembled. When we use the word
“DRY RUN” this means you do not silicone anything, just simply construct the shower, align, drill and screw everything together. Once you are happy with the build take the
unit apart and carry out the final fix.
What’s In The Boxes?
Tray Box
1x Tray
1x Roof
2x Curved Rails
1 x AC-DC 12V Adapter
Glass Room
2x Door seals
2x Glass doors
2x fixed glass
Backwalls
1x complete acrylic pre-formed backwall
In addition to above you will have all the required internal accessories to complete the shower
www.insigniarange.com Last Modied:27/01/2017
08
Insignia Screw Pack
VERY IMPORTANT
Have you got everything? If not please contact the Insignia Support Line on 01908 226545. Remember NEVER book your tradesman until everything has arrived, been
checked and is present. No replacement/missing parts can be obtained free of charge during or after the build. Any claims can only be within the timescale permitted (48
hours after delivery) and always BEFORE build.
Product Code Descripon Quanty
SP097 Door Handles 2
SP006 Chrome Door Wheels 8
ST20 20mm Screws 20
ST35 35mm Screws 10
ST13 14mm Screws 6
ST25 25mm Screws 10
PRC20 Retaining Clips 4
DB6 Drill Piece 1
Note: In some cases you may have more screws than needed, this is done so you have spares!
www.insigniarange.com Last Modied:27/01/2017
09
Pressure Requirements from your house supply
We recommend a bar pressure between 2.5 and 3.4 BAR. If you have a combi boiler system no problem should be experienced. If you have a gravity feed older type
installation (hot water tank type usually less than 1 bar) you will almost certainly need a pump. We cannot advise on which type of pump is used, location or design because
all house plumbing layouts vary. This is a job for your installer/plumber. The end delivery however must fall within the scope above.
Important Note Do not exceed 3.4 BAR pressure under any circumstances. Warranty is void if so as damage will occur. If you have a combi supply, please use a pressure
reducing valve if required to lower the BAR pressure to the shower.
Please Remember that this product is free standing and is designed to be pulled away from the wall.
The waste hose must be of a flexible type (1m flexible waste supplied).
The water supply pipes need to be at least 1 metre in length and must be that of a flexible braided type (not supplied).
DO NOT OVERTIGHTEN THE BRAIDED HOSES AS IT CAN CAUSE THE CONNECTION TO POP AFTER A FEW WEEKS OF USE
www.insigniarange.com Last Modied:27/01/2017
10
www.insigniarange.com Last Modied:27/01/2017
11
TO START
Make sure you have a clear space, remember when finished and in place you need access to check your build and
able to pull the shower out for servicing or should you have the need to replace anything!
Take the shower tub and remove all the protective wrapping and fit the waste. In the side of the waste supplied in the
optional fitting kit you will notice a spigot not seen on an ordinary waste. In most cases this is blanked yet should you
have a steam version you need to gently drill this out as this item is for the steam generator drainage and will be con-
nected in the instructions later.
Now please level the tray by firstly placing the tray in its final location and then using a spirit level, adjust the tray feet
accordingly. Once you are happy with the levelling of the tray, you can pull it out to begin the main construction.
Step 1
Attach the uprights to the top and bottom curved rail using
the ST35 screws. The end with the curved groove is
designed to sit on the tray, with the flat end connecting to
the roof. Please note the ‘U’ shaped channel is meant to
face inwards to allow the glass to fit correctly.
(Insignia logo on top rail)
PLEASE NOTE
The screw head needs to bypass the OUTER hole. If this
does not occur please bore out the outer hole only by
about 2-4mm
www.insigniarange.com Last Modied:27/01/2017
12
Step 3
Align the 2 x side glass panels with the rubber seal into the
glass frame as shown below and push tightly in to position.
Once both panels are tightly in place you can secure the outer
edges of the glass in to position using the glass retaining clips
(PRC20) as shown in the image. To do this simply align the
clips tight up to the glass and using screw type ST13 screw in
to position. Do this for all 4 clips (2 x top and 2 x bottom)
Step 2
Take the 2 x pieces of flat side glass and run the plastic seal down 1
side of each piece and cut to length if required.
www.insigniarange.com Last Modied:27/01/2017
13
Step 4
Offer your glass frame up to the tray
Step 5
Taking the pre-fabricated back wall, offer it up to the tray and align to the front
glass. Once you are happy with the overall position, remove the back wall and
run a bead of silicone under the bottom of the back wall and place back on the
tray. This will add to the water tightness once finished.
Using Screw type ST20 attach the back wall to the front glass framework as
shown above.
www.insigniarange.com Last Modied:27/01/2017
14
Step 6
Screw the back wall to the tray using screw type ST25
www.insigniarange.com Last Modied:27/01/2017
15
Step 7
Align the roof on to the top of the shower as shown below and secure in to position using screw type ST20
screws. Fill in any gaps with white silicone to seal the roof in place.
Step 8
Fit the adjustable wheels to the top and bottom of the glass doors and ensure the wheels
are at their lowest position and hang on the inner curved rails with the wheels facing the
outside of the glass.
Once all wheels are fitted and on the rails you can adjust the wheels by turning the plastic
bolt clockwise in which in turn will pull the wheels towards the track ensuring a secure a
tight fit.
Now grease the track to ensure a smooth and long lasting operation
(not supplied)
www.insigniarange.com Last Modied:27/01/2017
16
Hose
Attach the chrome flexible hose to the hand shower and water
outlet as shown in the image. Ensure you place the chrome
sleeve end to the hand shower coupling allowing it to sit com-
fortably in the shower holder.
Accessory Installation
Monsoon Head
Attach the grey hose from your valve to the inner black
tube using PTFE tape (please note this only needs to be
hand tight. Over tightening will snap/damage the inner
black tube)
Handle
Ensuring that the inner thread is
protruding out from the handle far
enough, place the handle on the
outside of the door and secure by
tightening the inner chrome knob to
the protruding inner thread.
www.insigniarange.com Last Modied:27/01/2017
17
Door Seals
Magnetic Seal: Push the magnetic door seal on the handle side of the glass door ensuring this is
tightly fitted.
Rear Door Seal: Place the rear door seal on the opposite side to the magnetic strip ensuring the
flap is facing the fixed glass panel
Hot Water InletCold Water Inlet
Body Jets
Hand Shower
Monsoon Shower
Shower Valve
Connect the corresponding hoses to the rear of the valve as shown.
Device output may differ from the image. Please refer to your outer chrome faceplate in-
side your Insignia shower as a reference point.
IF YOUR DIAL DOES NOT CORROSPOND TO THE APPROPRIATE DEVICE:
Turn on your water to the shower and note which output the water exits from then turn off
the water and swap over the relevant hose.
Alternatively remove the outer chrome knob by removing the chrome cap and loosening
the grub screw (please ensure not to unscrew fully as this will drop within the chrome
knob) this is found on the opposite side to the chrome pillar. Once you have succeeded in
loosening this you can now slide your faceplate to correspond to the device.
www.insigniarange.com Last Modied:27/01/2017
18
Electric Box Connections
Connect the cables below to the corresponding devices on the shower
Roof Light
Fan
Speaker
Antenna
Back Lights
RJ11 Phone Connection
12V power Supply
www.insigniarange.com Last Modied:27/01/2017
19
Silicone Seal where shown in red on the inside of the shower
TESTING FOR WATER LEAKS
LEAVE THE SHOWER 24 HOURS AFTER BUILD TO ALLOW SEALENT TO CURE AND ENSURE
THE SHOWER IS AWAY FROM ITS FINAL POSITION TO ALLOW REAR VIEWING
Ensure all connections are tight and sealed including the waste, body jets and steam outlet (model
dependent) on your shower.
Switch on the overhead shower NOT the massage jets, remember these will fire water out at you
and are not suitable for checking leaks as they would normally only operate when a person is in
front of them. DO NOT AIM THE HAND SHOWER AT THE JOINTS OF YOUR SHOWER AS THIS
DOES NOT FALL UNDER “NORMAL EVERYDAY USE”. Adjust the feet to ensure the direction of
the water flows towards to the waste to prevent puddling.
Just use COLD water setting as hot will make cabin misty and condensate thus the inspection be-
comes very difficult. Now on the OUTSIDE of the shower inspect each joint, factory seal, hose, clip
and jet by walking from one side and going around to the back and then to the other side finishing at
the front. If you have a small leak (normally caused through insufficient sealer or air bubble on as-
sembly, dry the area thoroughly and reseal.
Please remember the location of the water may not be exactly where the leak is as it could have run
around to a low point. Never seal your inner fittings unless necessary, remember you will see this
for the life of the shower! Again leave to cure and check. Once you are happy check the shower
functions i.e. jets for back massage, foot massage and finally hand shower (model dependent)
check your joints to these functions at the rear again. Never use the shower until all checks have
been made and the installer is 100% happy in the knowledge no leaks are present.
All good?
Now push your shower FROM THE BASE and NEVER THE GLASS OR FRAME into its final resting
position.
Happy Showering!
www.insigniarange.com Last Modied:27/01/2017
20
TL-2070GS Control Panel Instructions
Buon 1 (+ VOL)
Volume Up
Buon 2 (Down Arrow)
Radio Search Down
Buon 3 (Up Arrow)
Radio Search Up
Buon 4 (- VOL)
Volume Down
Buon 5 (Power)
On/O
Buon 6 (Telephone)
Answer telephone
Buon 7 (FM)
Radio On/O
Buon 8 (LIGHT)
On/O
Buon 9 (FAN)
On/O
1
23
4
5
67
89

Other Insignia Bathroom Fixture manuals

Insignia KSY1450 Series User manual

Insignia

Insignia KSY1450 Series User manual

Insignia MY810L User manual

Insignia

Insignia MY810L User manual

Insignia INS8719 User manual

Insignia

Insignia INS8719 User manual

Insignia Platinum Series User manual

Insignia

Insignia Platinum Series User manual

Insignia 1500 Series User manual

Insignia

Insignia 1500 Series User manual

Insignia ES001 User manual

Insignia

Insignia ES001 User manual

Insignia GT6000 User manual

Insignia

Insignia GT6000 User manual

Insignia INS8059.1L User manual

Insignia

Insignia INS8059.1L User manual

Insignia ES009 User manual

Insignia

Insignia ES009 User manual

Insignia Platinum Series User manual

Insignia

Insignia Platinum Series User manual

Insignia INS9012 User manual

Insignia

Insignia INS9012 User manual

Insignia Diamond Series User manual

Insignia

Insignia Diamond Series User manual

Insignia MC90CQ User manual

Insignia

Insignia MC90CQ User manual

Insignia Premium Series User manual

Insignia

Insignia Premium Series User manual

Insignia Premium Series User manual

Insignia

Insignia Premium Series User manual

Insignia 900 User manual

Insignia

Insignia 900 User manual

Insignia Monochrome Series User manual

Insignia

Insignia Monochrome Series User manual

Insignia ECO Series User manual

Insignia

Insignia ECO Series User manual

Insignia GT4000 User manual

Insignia

Insignia GT4000 User manual

Insignia Diamond Series User manual

Insignia

Insignia Diamond Series User manual

Insignia 1800 Series User manual

Insignia

Insignia 1800 Series User manual

Insignia INS8058.1R User manual

Insignia

Insignia INS8058.1R User manual

Insignia S7804 User manual

Insignia

Insignia S7804 User manual

Insignia MC115RT User manual

Insignia

Insignia MC115RT User manual

Popular Bathroom Fixture manuals by other brands

Delta 75628 Series installation instructions

Delta

Delta 75628 Series installation instructions

Delta SENTIMENT 25712LF-SS quick start guide

Delta

Delta SENTIMENT 25712LF-SS quick start guide

Delta 35764LF-SPPD-R manual

Delta

Delta 35764LF-SPPD-R manual

Delta Windemere B3596LF-SS manual

Delta

Delta Windemere B3596LF-SS manual

Delta 25840LF installation instructions

Delta

Delta 25840LF installation instructions

Concept2 4-part corner entry with swing doors Assembly instruction

Concept2

Concept2 4-part corner entry with swing doors Assembly instruction

Dreamline AQUA UNO Installation instruction

Dreamline

Dreamline AQUA UNO Installation instruction

Delta 59348 manual

Delta

Delta 59348 manual

Dreamline ALLIANCE PRO SDAL48W700 installation instructions

Dreamline

Dreamline ALLIANCE PRO SDAL48W700 installation instructions

NewLine Curved instruction manual

NewLine

NewLine Curved instruction manual

LaGard ALTEA Installation

LaGard

LaGard ALTEA Installation

Dreamline FLEX Shower Enclosure Installation instruction

Dreamline

Dreamline FLEX Shower Enclosure Installation instruction

Ro-Man DXL1HDR instruction manual

Ro-Man

Ro-Man DXL1HDR instruction manual

Delta Modern 559LF-PP manual

Delta

Delta Modern 559LF-PP manual

Gessi OVALE 21636 manual

Gessi

Gessi OVALE 21636 manual

Pacific Bay Treviso Roman Tub Faucet PB-RT01 installation manual

Pacific Bay

Pacific Bay Treviso Roman Tub Faucet PB-RT01 installation manual

PHOTON PHO-100FW/CC-CP user guide

PHOTON

PHOTON PHO-100FW/CC-CP user guide

Sensea ESSENTIAL 3276000677109 Assembly, use and maintenance

Sensea

Sensea ESSENTIAL 3276000677109 Assembly, use and maintenance

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.