Installation
Install the controller
WARNING
To prevent tampering, make sure the controller is only accessible to authorized
personnel (e.g. key-locked electrical panel).
1. Mount the controller on the DIN rail.
2. Make electrical connections.
Install the application
Note: if the execution process fails, it may be that the dependencies needed by the application are
not installed on the computer..
1. Download the LBK Designer application from the www.leuze.com website.
2. Install the application on the computer.
3. With Microsoft Windows operating system, download and install from the same site also the
driver for USB connection.
Start the LBK Designer application
1. Connect the controller to the computer using a data USB cable with a micro-USB connector or
the Ethernet cable (if an Ethernet port is available).
2. Supply power to the controller.
3. Start the LBK Designer application.
4. Choose the connection mode (data micro-USB or Ethernet).
Note: the default IP address for the Ethernet connection is 192.168.0.20.
5. Set a new admin password, memorize it and provide it only to people who are authorized to
change the configuration.
6. Select the sensor type and the number of sensors.
7. (only for LBK S-01 System) Set the working frequency. If the system is installed in one of the
countries with national restrictions, select the restricted band, otherwise select the full band.
Note: this setting does not have any effect on system performance or safety.
8. (only for LBK SBV System) Set the country in which the system is installed.
Note: this setting does not have any effect on system performance.
9. (only for LBK SBV System) Select the application type.
Installation
Leuze electronic GmbH + Co. KG Sensor LBK S-01 7