CONTROLLER SETUP
When using a Model 10A11-1, Rev C for two-way communication
with a central station, the Two-Way Voice option must be enabled.
FromtheInstallerSetupmenu,
select the 3 (DCM) key. Press the down arrow ( ) key until you
reachtheTwo-WayAudiooption:
TWO-WAY AUDIO: 0
0=NO 1=YES
Press1(YES),andthenpress'#'toenabletwo-wayaudio
communication.
When using a Model 10A11-1, Rev C to announce alarms, the
Announce Alarms option must be enabled. To enable this option,
fromtheSetupmenupressthe6(MISC)key.
Press the down arrow ( ) key to until you reach the Announce
Alarmsoption:
ANNOUNCE ALARMS: 0
0=NO 1=YES
Press1(YES),andthenpress'#'toenablethesystemannouncealarms.
OPERATION
The Two-Way Audio Module has two modes of audio communication:
1. Listen modeisusedtolistentothepremisesfromaninside,remote,orcentralstationtelephone.Yo u cannottalktoanyoneonpremisesinlistenmode.Wheneverthemodule
is switched on, it is set to the listen mode.
2. Talk modeisusedtotalktosomeoneon-premisesfromaninside,remote,orcentralstationtelephone.Yo u cannotlistentothepremiseswhileinthetalkmode.Themode
can be changed between listen and talk by using the keys on a phone. When the module is switched on, a 90 second disconnect timer is started. If no tones are detected
within 90 seconds, the module will be switched off. Each time a tone is received, the timer is reset.
CENTRAL STATION OPERATION
When an alarm occurs, the communicator first sends the appropriate report to the central station. After the transmission of the alarm to the central station, the operator can talk
and listen to people and sounds at the premises. After the report is received by the central station operator, the Two-Way Audio Module is switched on. The central station operator
can now listen to the premises. The module is always first switched on in the listen mode. The operator can control the direction of the communication by using the Touch-Tones
onatelephone.Eachtimetheoperatorswitchesbetweenthelistenandthetalkmode,ashorttonewillsoundovertheaudiospeakeratthesubscriber'spremises.Thisalertsthe
subscriber that the operator has switched communication mode. If no tones are detected within 90 seconds, the module will disconnect from the phone line.
PRESS 2 FOR CENTRAL STATION TO TALK TO THE PREMISES
PRESS 8 FOR CENTRAL STATION TO LISTEN TO THE PREMISES
PRESS 4 TO DISCONNECT (HANG UP) THE PHONE LINE
When the Two-Way Audio Module is switched on after an alarm transmission, the siren is automatically switched off so the central station can listen and talk to the premises.
PAGING AND LISTENING
By accessing the telephone menu, you can use an inside or remote phone to talk (page) and listen to someone on the premises.
1) From the main telephone menu choose the 8 (PHONE).
2) To talk or listen to the premises, press the 3 (INTERIOR).
3) To talk to someone at the premises, press the 2 key.
4) To listen to the premises, press the 8 key.
• Ifnokeyispressed,thesystemwillautomaticallyswitchtolistenmode.
• Whencomplete,press*toreturntothemaintelephonemenu.
• Ifnotonesaredetectedwithin90seconds,themodulewillswitchoffandyouwillreturntothemaintelephonemenu.
ANNUNCIATION OF ALARM
The Voice Alarm Module enables the system to speak the type of alarm and zone over a speaker on premises. When an alarm first occurs, the siren is activated. After a few
seconds, the siren is turned off and the type of alarm is announced. The siren is then reactivated. After a few seconds, the siren is again turned off and the violated zone is
announced. The siren is then reactivated. This process is repeated until the alarm is disarmed or reset.
NOTE: During central station communication (while the system is reporting an alarm to the central station), voice alarm notifications are temporarily suspended. After the
successful transmission of the alarm to the central station, voice alarm notifications are restarted.
SPEAKER VOLUME CONTROL
Thevolumeoftheaudiocanbecontrolledbyadjustingavariableresistoronthemodule.UseasmallscrewdrivertoadjustR35labeled"SpeakerVolume".
Do notadjustR59labeled"AudioCancel".Thisvariableresistoritisadjustedatthefactorytoitsoptimalsetting.
DI-021-OA103-00AAR2213
FCC Compliance
ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigitaldevice,pursuanttopart15oftheFCCRules.Theselimitsaredesignedtoprovide
reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and
usedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradiocommunications.However,thereisnoguaranteethatinterferencewillnotoccurinaparticular
installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged
totrytocorrecttheinterferencebyoneormoreofthefollowingmeasures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consultthedealeroranexperiencedradio/TVtechnicianforhelp.
LEVITON LIMITED WARRANTY
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that products manufactured by Leviton under the Leviton brand name (“Product”) will be free from
defects in material and workmanship for the time periods indicated below, whichever is shorter: • OmniPro II and Lumina Pro: three (3) years from installation or 42 months from manufacture date.
• OmniLT, Omni IIe, and Lumina: two (2) years from installation or 30 months from manufacture date. • Thermostats, Accessories: two (2) years from installation or 30 months from manufacture date.
• Batteries: Rechargeable batteries in products are warranted for ninety (90) days from date of purchase. Note: Primary (non-rechargeable) batteries shipped in products are not warranted.
Products with Windows®Operating Systems: During the warranty period, Leviton will restore corrupted operating systems to factory default at no charge, provided that the product has been used as
originally intended. Installation of non-Leviton software or modification of the operating system voids this warranty. Leviton’s obligation under this Limited Warranty is limited to the repair or replacement,
at Leviton’s option, of Product that fails due to defect in material or workmanship. Leviton reserves the right to replace product under this Limited Warranty with new or remanufactured product.
Leviton will not be responsible for labor costs of removal or reinstallation of Product. The repaired or replaced product is then warranted under the terms of this Limited Warranty for the remainder
of the Limited Warranty time period or ninety (90) days, whichever is longer. This Limited Warranty does not cover PC-based software products. Leviton is not responsible for conditions or applications
beyond Leviton’s control. Leviton is not responsible for issues related to improper installation, including failure to follow written Installation and operation instructions, normal wear and
tear, catastrophe, fault or negligence of the user or other problems external to the Product. To view complete warranty and instructions for returning product, please visit us at www.leviton.com.
Usehereinofthirdpartytrademarks,servicemarks,tradenames,brandnamesand/orproductnamesareforinformationalpurposesonly,are/maybethetrademarksoftheir
respective owners; such use is not meant to imply affiliation, sponsorship, or endorsement.