manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Lumel
  6. •
  7. Transducer
  8. •
  9. Lumel P11P User manual

Lumel P11P User manual

This manual suits for next models

2

Other Lumel Transducer manuals

Lumel P30U series User manual

Lumel

Lumel P30U series User manual

Lumel P30O User manual

Lumel

Lumel P30O User manual

Lumel P43 User manual

Lumel

Lumel P43 User manual

Lumel P30P User manual

Lumel

Lumel P30P User manual

Lumel P41 User manual

Lumel

Lumel P41 User manual

Lumel P43 User manual

Lumel

Lumel P43 User manual

Lumel P21Z Series User manual

Lumel

Lumel P21Z Series User manual

Lumel P20 User manual

Lumel

Lumel P20 User manual

Lumel P15 User manual

Lumel

Lumel P15 User manual

Lumel P30H User manual

Lumel

Lumel P30H User manual

Lumel P21Z Series User manual

Lumel

Lumel P21Z Series User manual

Lumel P18S User manual

Lumel

Lumel P18S User manual

Lumel VTR10 User manual

Lumel

Lumel VTR10 User manual

Lumel P30H User manual

Lumel

Lumel P30H User manual

Lumel P18D User manual

Lumel

Lumel P18D User manual

Lumel P20G series User manual

Lumel

Lumel P20G series User manual

Lumel P30O User manual

Lumel

Lumel P30O User manual

Lumel P30P User manual

Lumel

Lumel P30P User manual

Lumel P18D User manual

Lumel

Lumel P18D User manual

Lumel P19 User manual

Lumel

Lumel P19 User manual

Lumel P10 User manual

Lumel

Lumel P10 User manual

Lumel P18S User manual

Lumel

Lumel P18S User manual

Lumel P30U series User manual

Lumel

Lumel P30U series User manual

Lumel ULT20 User manual

Lumel

Lumel ULT20 User manual

Popular Transducer manuals by other brands

LEM DK series installation guide

LEM

LEM DK series installation guide

HBM AD101B quick start guide

HBM

HBM AD101B quick start guide

Camille Bauer SINEAX F534 operating instructions

Camille Bauer

Camille Bauer SINEAX F534 operating instructions

Trane KIT 16724 Installer's guide

Trane

Trane KIT 16724 Installer's guide

B&C Speakers DE75PTN datasheet

B&C Speakers

B&C Speakers DE75PTN datasheet

Mianyang Weibo Electronic WB Series user manual

Mianyang Weibo Electronic

Mianyang Weibo Electronic WB Series user manual

ProMinent Dulcometer DMT operating instructions

ProMinent

ProMinent Dulcometer DMT operating instructions

Camille Bauer SIRAX CH-5610 operating instructions

Camille Bauer

Camille Bauer SIRAX CH-5610 operating instructions

Veris Industries PW Series installation guide

Veris Industries

Veris Industries PW Series installation guide

HBM TJ1-S6 installation manual

HBM

HBM TJ1-S6 installation manual

Simrad ES120-7C -  REV D Dimensions

Simrad

Simrad ES120-7C - REV D Dimensions

HBM C18 Mounting instructions

HBM

HBM C18 Mounting instructions

Spirax Sarco ITV1030 Installation and maintenance instructions

Spirax Sarco

Spirax Sarco ITV1030 Installation and maintenance instructions

MAMAC SYSTEMS PR-243 technical information

MAMAC SYSTEMS

MAMAC SYSTEMS PR-243 technical information

Balluff BTL5-P user guide

Balluff

Balluff BTL5-P user guide

MKS MicroPirani 925 Series Short form manual

MKS

MKS MicroPirani 925 Series Short form manual

WIKA WU-20 operating instructions

WIKA

WIKA WU-20 operating instructions

Alcatel Vacuum Technology BARATRON 622A instruction manual

Alcatel Vacuum Technology

Alcatel Vacuum Technology BARATRON 622A instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1
ISO 9001ISO 9001
CERTYFIKAT
SERVICE MANUAL
POWER TRANSDUCERS
FOR SINGLE-PHASE
AND THREE-PHASE NETWORK
P11P, P13P and P13B
45 ´120 ´100 mm
2
Contents Page
1. APPLICATION .......................................................................... 3
2. BASIC REQUIREMENTS......................................................... 3
3. TRANSDUCER SET ................................................................. 4
4. TECHNICAL DATA ................................................................... 5
5. INSTALLATION ........................................................................ 7
5.1. Fixing ................................................................................. 7
5.2. Connection diagrams ........................................................ 8
5.2.1. Measurement of active power in a single-phase
network ................................................................... 8
5.2.2. Measurement of active power in a 3-phase
3-wire network ......................................................... 9
5.2.3. Measurement of reactive power in a 3-phase
3-wire network ........................................................ 11
6. CODING AND ORDERING .................................................... 12
7. MAINTENANCE AND GUARANTEE..................................... 15
3
1. APPLICATION
The P11P transducer is destined for the conversion of active or
reactive a.c. power into a d.c. current or d.c. voltage standard
signal. The input, output and supply circuits are galvanically
isolated (transformer separation) The conversion frequency range
enables the correct measurement of power when currents and
voltages are distorted (up to 25 th harmonic).
The pulse feeder ensures the operation in a width range of values
and frequency of the supply voltage. The measurement is realised
through the analogue multiplier function with the pulse modulation
(TDM). These transducers are destined to operate in industrial
conditions and can be mounted in optional position. Transducer
housings are made of a self-extinguishing plastic and are adapted
to be fixed on 35 mm DIN rail (DIN EN 50 022-35).
P11P - transducer destined for active power measurement
in a single-phase network.
P13P - transducer destined for active power measurement
in a symmetrically loaded 3-phase 3-wire network.
P13B - transducer destined for reactive power measurement
in a symmetrically loaded 3-phase 3-wire network.
2. BASIC REQUIREMENTS, OPERATIONAL SAFETY
Symbols located in this service manual mean:
Especially important, one must acquaint with this before
connecting the transducer. The non-observance of notices
marked by these symbols can occasion the damage of the
transducer.
One must take note of this when the transducer is working
inconsistently to the expectations.
In the security scope the transducer meets the requirements of the
EN 61010-1 standard.
!
?
4
!
Remarks concerning the operator safety:
P11P, P13P and P13B transducers are destined to be mounted on
35 mm DIN rails. In the range of operational safety they are in
conformity with the EN 61010-1standard requirements.
lThe installation and transducer connection should be
operated by a qualified personnel.
lOne must take into consideration all accessible protection
requirements.
lBefore switching the instrument on, one must check the
correctness of the network lead connection.
lIn case of the protection terminal connection with a separate
lead one must remember to connect it before the connection
of network leads.
lDo not connect the instrument to the network through an
auto-transformer.
lBefore taking the transducer housing out, one must turn
the supply off.
lThe removal of the transducer housing during the guarantee
contract period may cause its cancellation. The programmer
connector is destined only for the PD11 programmer
connection. After the transducer programming, one should
put the hole plug of the programmer connector.
3. TRANSDUCER SET
The transducer set includes:
- P11P or P13P or P13B transducer 1 pc
- service manual 1 pc
- guarantee card 1 pc
5
4. TECHNICAL DATA
Basic parameters:
- input current 1 A (X/1 A), 5 A (X/5 A)
- input voltage 10/Ö3 V, 100 V, 230 V, 400 V,
500 V, 690 V, X/100 V
- output signals 5 mA, 20 mA, 4...20 mA, 10 V
- accuracy class 0.5
- output load resistance:
- for 5 mA current output 0...2000 W
- for 20 mA current output 0...500 W
- for 10 V voltage output ³500 W
- circuit consumption:
- voltage measurement £0.6 VA
- current measurement £0.3 VA
- supply £6 VA
- preheating time of the
transducer 15 min.
- set-up time of the output
signal (0/90%) £0.5 s
- insulation test voltage 3.25 kV
- limitation of output current 28 mA ± 10%
Nominal reference and operating conditions:
- ambient temperature -20...23...55°C
- supply voltage 18...40 V or 85...253 V a.c./d.c.
- frequency of the supply voltage 40...400 Hz
- frequency of the input current
(voltage) 45...65...1250 Hz
- input voltage 0...0.01...1.2 Un
- power factor (cos fi) - 1...0...1
- input current 0...0.01...1.2 In
- peak factor of the measured
current £3
6
- peak factor of the measured
voltage £2
- storage temperature - 25... + 85°C
- air relative humidity (condensation
inadmissible) 0... 45...75...85%
- external magnetic field 0...40...400 A/m
- working position any
Additional Errors caused by the influence of:
- frequency of the input quantity < 0.05 k/100 Hz
- ambient temperature < 0.5 k/10°C
- external magnetic field < 0.1 k/100 A/m.
Input overload:
Voltage:
- short duration 2 Un
- long-lasting 1.2 Un
Current:
- short duration 10 In
- long-lasting 1.2 In
Ensured protection degree:
- through the housing IP 50
- from the terminal side IP 20
Dimensions: 45 x 100 x 120 mm
Weight: 210 g
Compliance to standards:
- service security, requirements and tests EN 61010-1
- insulation ensured by the housing double
- insulation between circuits basic
- installation category III
- pollution level 2
- maximal working voltage in relation
to earth 600 V
7
Electromagnetic compatibility:
- immunity EN 50082-2
- emission EN 50081-2
5. INSTALLATION
5.1 Fixing
P11P, P13P or P13B transducers are designed to be installed on a
35 mm DIN rail acc. DIN EN 50 022-35. On the external side of the
transducer there are screw or self-locking terminal strips enabling
the connection of 2.5 mm2external leads (supply and output) and
up to 1.5 mm2leads (input).
Fig.1 Overall dimensions and fixing way of the transducer
P11P
35
93
120
41
100
45
35 mm DIN rail
8
5.2. Connection diagrams
5.2.1. Measurement of active power in a single-phase network
by a P11P transducer.
10915
+
16
1
L1
23 5
P11P
NorL2
Supply Output
10915
+
16
1
L1
S1 S2
23 5
P11P
NorL2
P1 P2
Supply Output
a) Direct measurement of
single-phase active power
b) Measurement of single-
phase active power through
a current transformer
9
10915
+
16
1
L1
S1
ba S2
23 5
P11P
NorL2
P1 P2
B
A
Supply Output
c) Measurement of single-phase
active power through a current
and voltage transformer
5.2.2. Measurement of active power in a 3-phase 3-wire
network by a P13P transducer (Symmetrically loaded)
10915
+
16
12
L1
35 8
P13P
Supply Output
L2
L3
a) Direct measurement of active
power in a 3-phase 3-wire
network symmetrically loaded
10
L2
10915
+
16
1
L1
S1 S2
23 5
P13P
Supply Output
P1 P2
L3
8
10915
+
16
1
L1
S1
ba S2
23 5
P13P
Supply Output
P1 P2
B
A
8
L2
L3
ba
B
A
b) Measurement of active power in a
3-phase 3-wire network symmetri-
cally loaded through a current
transformer
c) Measurement of active power in a
3-phase 3-wire network symmetri-
cally loaded through a current and
a voltage transformer