20
Pre-Application System Checkout
Before beginning actual spraying, perform the following
“pre-application” procedure to ensure that your valve
settings, nozzle selection and desired speed range will allow
the MT-400 to provide the required application control. This
procedure should be repeated for each new nozzle selection
and/or application rate. By performing all of the steps listed
below, you set up your system to allow the MT-400 to
perform at optimum level. Fill your sprayer tank with clean
water. DO NOT use chemicals until the entire system is
completely checked out and operating properly.
NOTE: Most nozzles will maintain a good pattern over a
maximum speed range of two to one. (For example, if your
maximum speed is 12, your minimum speed shouldn’t go
below 6.)
Pre-application System Checkout is a procedure performed
while the console is in the CAL mode. The red warning light
will be lit during the procedure and “CAL” on the display will
be flashing.
1. Start vehicle and pump, bring the engine up to normal
operating RPM.
2. Enter MAXIMUM application TEST SPEED into console.
Turn all booms OFF and enter calibration mode.
CAL will appear on display and red light will be on.
Turn rotary switch to TEST SPEED position. Use “+” or
“-” button to enter maximum application speed. Do
not exit calibration mode. CAL will flash on the display
indicating TEST SPEED mode.
3. Select manual “MAN” control mode and turn all lane
control switches ON.
4. Turn rotary switch to APP. RATE position and hold “+”
button for approximately 30 seconds to completely
open the servo valve (control valve). (Maximum flow
output to lane).
CAN’T GET THERE?
If you can’t get to the desired application rate, you may
need different nozzles, pump, or you may need to make
modifications to your plumbing configuration. Please refer
to Troubleshooting Plumbing.
• Now is a good time to confirm that GPM, MPH, WIDTH
and PSI all coincide with the nozzle manufacturer’s
charts. PSI may be slightly higher than indicated by the
charts due to pressure drop across the solenoid valve,
nozzle diaphragm check valves, nozzle screen, etc.
5. Turn all lane control switches OFF and enter MINIMUM
application TEST SPEED into console. Turn rotary switch
to TEST SPEED position. Use the “+” or “-” button to enter
minimum application speed. Do not exit calibration
mode. (Remember, the minimum application speed is
not normally less than half of the maximum application
speed).
6. Turn all active lane control switches ON. Make certain
system is in manual mode, turn rotary switch to the APP.
RATE position and hold “-” button for approximately 30
seconds to completely close the servo valve (control
valve). (Minimum flow output to lane). The display should
now read less than the desired application rate.
• It is not normally a problem if the application rate goes
all the way to zero when holding the “-” button for 30
seconds, as long as it goes back up when the “+” button
is held.
CAN’T GET THERE?
If holding the “-” button does not get the application rate
to go below the desired application rate, please refer to
Troubleshooting Plumbing.
7. Enter the TARGET application TEST SPEED into console.
Turn booms OFF. Turn rotary switch to TEST SPEED
position. Use the “+” or “-” button to enter target
application speed. Do not exit calibration mode.
8. Select automatic “AUTO” control mode, turn booms ON
and turn rotary switch to APP. RATE position. The console
should take control and lock-on to your calibrated target
application rate.
• If you calibrated your ADJUST RATE to zero (0), disregard
steps 9 and 10.
9. Press the “+” button and release. The display will
momentarily show the new target rate (target rate +
adjust rate) and then lock on to that rate.
10. Press the “-” button and release. The display will
momentarily show the new target rate (target rate -
adjust rate) and then lock on to that rate.
• If the application rate was correctly displayed during
manual “MAN” control mode, but registered too high in
automatic “AUTO” control mode, the calibration value
for MIN FLOW is set too high.
At this point, the Pre-application System Checkout is
complete. TEST SPEED will automatically cancel when you
exit the CAL mode or when power to the console is turned
OFF.