Nibe ESV 22 User manual

MAV 0935-2
ESV 22
031261 ESV 22
MONTERINGSANVISNING EXTRA SHUNT ESV 22 TILL NIBE SPLIT
SE
INSTALLATION INSTRUCTIONS EXTRA SHUNT ESV 22 FOR NIBE SPLIT
GB
MONTAGEANLEITUNG EXTRA MISCHGRUPPE ESV 22 FÜR NIBE SPLIT
DE
ASENNUSOHJE ESV 22 LISÄSHUNTTIRYHMÄLLE KÄYTETTÄVÄKSI NIBE SPLIT KANSSA
FI
LEK
LEK
GRUNDFOS
Type UPS 25 - 60 130 P/N:59526447
230V-
HEJSAN
PC;0017NIB
DK
50Hz
IP 44
TF 110
Class H
Max. 10bar
2.5uF
45
0.20
65
0.30
90
0.40
1m(A) P,(W)


MONTERINGSANVISNING
ESV 22
Allmänt
Detta tillbehör används då NIBE ACVM 270 installeras i hus
med två olika värmesystem som kräver olika framlednings-
temperaturer, t.ex. då huset har både radiatorsystem och
golvvärmesystem. I nedanstående text avser värmesystem 1
det system som kräver den högre temperaturen och som
kopplas in till den ordinarie framlednings- respektive returled-
ningsanslutningen. Värmesystem 2 avser det värmesystem
som arbetar med lägre temperatur.
Vattenflödet i de två värmesystemen tillsammans bör ej
överstiga 2050 l/h (0,57 l/s).
OBS!
Detta tillbehör kräver även tillbehöret ACK 22.
Innehåll
3-ledare för cirkulationspump1st
Buntband4st
Värmeledningspasta2st
Isoleringstejp1st
Planpackning2st
Rundhylsa4st
Cirkulationspump Union 3-hastighet, EP21-GP201st
Kulventil M Unionsmutter2st
3-vägsventil1st
Aluminiumtejp (bitar)2st
Temperaturgivare, EP21-BT2 (framledningsgivare),
EP21-BT3 (returledningsgivare)
2st
Reglermotor, EP21-QN251st
3ESV 22
SE

Röranslutning ACVM 270
Montering sker enligt följande:
႑Töm först pannvattenkärlet/värmesystemet om detta är
vattenfyllt.
႑Den extra värmebärarpumpen (EP21-GP20) placeras på
lämplig plats utanför ACVM 270.
႑Shuntventilen (EP21-QN25) placeras på framledningen
efter ACVM 270, före första radiator på värmesystem 1.
Returledningen från värmesystem 2 kopplas till shuntven-
tilen (EP21-QN25) samt till returledningen från värmesy-
stem 1, se bild.
႑Framledningsgivaren (EP21-BT2) monteras på röret efter
värmebärarpumpen (EP21-GP20).
႑Returledningsgivaren (EP21-BT3) monteras på röret från
värmesystem 2.
႑Vid montering av givare skall värmeledningspasta använ-
das samt röret isoleras för att erhålla korrekt temperatur-
mätning.
OBS!
Vid felaktig montering kan funktionen äventyras.
LEK
Shuntventil, (EP21-QN25)
Anslutningar, Ø 22 mm
LEK
Retur
ACVM 270 Framledning
Pump- och tryckfallsdiagram
Flöde
kPa
l/h
10
200
0
0
20
400
30
600
40
800
50
1000
60
1200
70
1400 1600 1800 2000
l/s
0,50,40,30,20,10
Flöde
l/h
l/s
Tillgängligt tryck,
kPa
1
2
3
ESV 224
SE

Principschema ACVM 270 med ESV 22 - extra shunt
BT 1
RG10/
RE10
Erf. säker-
hetsutr.
FL1
FQ1
CM1
GP10
Överströmnings ventil
EP21-QN25
EP21-GP20
EP21-BT2
EP21-BT3
CP1
UKV40
Erforderlig säkerhetsutr.
Överströmningsventil
Förklaring
Utjämningskärl UKVCP1Temperaturgivare, utomhusBT1
Extra cirkulationspumpEP21-GP20Temperaturgivare, framledning 2EP21-BT2
ShuntventilEP21-QN25Temperaturgivare, returledning 2EP21-BT3
ExpansionskärlCM1
5ESV 22
SE

Elinkoppling ACVM 270
OBS!
All elektrisk inkoppling skall ske av behörig elektriker.
Elektrisk installation och ledningsdragning skall utföras
enligt gällande bestämmelser.
ACVM 270 ska vara spänningslös vid installation av
ESV 22.
Elscheman finns i slutet av denna monteringsanvisning.
Från ESV 22
Elkoppling,
X6
EBV
AA22
AA22:X4
1. Tillbehöret ACK 22 installeras enligt medföljande monte-
ringsanvisning.
2. Givarna kopplas in med tvåledare (exempelvis EKXX eller
LiYY) enligt följande till effektvaktskortet (EBV–AA22)
se bild nedan:
Använd medföljande rundstiftshylsor för skarvning mellan
2-ledarna och givarna BT2 och BT3.
-AA22
EBV-kort
>-EP21
Värmesystem 2 (Tillbehör)
Tempgivare framledning 2
Tempgivare returledning 2
X4
Den givare som används som framledningsgivare
(EP21-BT2) ansluts till position AA22:X4:7 och
AA22:X4:8 i effektvaktskortets nedre plint.
-
Returledningsgivaren (EP21-BT3) kopplas in till posi-
tion AA22:X4:5 och AA22:X4:6 på samma kort.
-
3. Ventilställdonet (EP21-QN25) anslutes enligt följande:
Brun ledare (230 V signal) till fjäderplinten X6:7b-
Vit ledare (230 V signal) till fjäderplinten X6:8a-
Blå ledare (nolla) till fjäderplinten X6:6b-
4. Cirkulationspumpen (EP21-GP20) anslutes enligt följande:
Blå ledare (nolla) till fjäderplinten –X6:6a-
Gul/grön ledare (jordledare) till fjäderplinten –X6:5a-
Brun ledare (fas) till fjäderplinten –X6:4a-
7
8
6
4
5
3
2
1
Elkoppling,
X6
Vit
Brun
Blå
Gul/grön
Brun
Montering av temperaturgivare
K
Temperaturgivaren monteras med buntband tillsammans
med värmeledningspasta och aluminiumtape.
Därefter skall den isoleras med medföljande isolertape.
OBS!
Givar- och kommunikationskablar får ej förläggas i
närheten av starkströmsledning.
ESV 226
SE

Programinställningar ACVM 270
႑Välj “Service” i meny 8.1.1 för att få tillgång till meny
9.0 och dess undermenyer.
႑Välj sedan “Värme”, "Värme + Kyla" eller "Kyla" i meny
9.3.4, “Värmesystem 2”. Därmed blir meny 3.0 och dess
undermenyer åtkomliga.
႑I undermenyerna ställs nu kurvlutning 2, förskjutning
värmekurva 2 samt min- och maxnivåer för framlednings-
temperatur 2 in på samma sätt som för värmesystem 1
under meny 2.0.
Se också “Monterings- och skötselanvisning” för NIBE SPLIT.
7ESV 22
SE

ESV 228
SE

INSTALLATION INSTRUCTIONS
ESV 22
General
This accessory is used when NIBE ACVM 270 is installed in
houses with two different heating systems that require dif-
ferent flow line temperatures, for example, in cases where
the house has both a radiator system and an under floor
heating system. In the following text Heating system 1 covers
the system that requires the greater temperature and that is
connected to the normal flow line respectively return line
connection. Heating system 2 covers the heating system that
works at the lower temperature.
The water flow in the two heating systems should not exceed
2050 l/h (0,57 l/s).
NOTE
This accessory also requires accessory ACK 22.
Contents
3 wire circulation pump1x
Cable ties4x
Heating pipe paste2x
Insulation tape1x
Flat gasket2x
Round sleeve4x
Circulation pump Union 3-speed, EP21-GP201x
Ball valve M Swivel nut2x
3-way valve1x
Aluminium tape (pieces)2x
Temperature sensor, EP21-BT2 (flow sensor), EP21-
BT3 (return sensor)
2x
Control motor, EP21-QN251x
9ESV 22
GB

Pipe connections ACVM 270
Install as follows:
႑First drain the boiler water reservoir/heating system if
filled with water.
႑Position the extra heat medium pump (EP21-GP20) in a
suitable location outside ACVM 270.
႑The shunt valve (EP21-QN25) is located on the flow line
after ACVM 270, before the first radiator in the heating
system 1. The return line from heating system 2 is con-
nected to the shunt valve (EP21-QN25) and to the return
line from heating system 1, see illustration.
႑The flow sensor (EP21-BT2) is installed on the pipe after
the heat medium pump (EP21-GP20).
႑The return line sensor (EP21-BT3) is installed on the pipe
from heating system 2.
႑When installing the sensor, heat conducting paste must
be used and the pipe must be insulated to obtain the
correct temperature measurement.
NOTE
Incorrect installation can affect the function.
LEK
By-pass valve, (EP21-QN25)
Connections, Ø 22 mm
LEK
Return
ACVM 270 Flow pipe
Pump and pressure drop diagrams
Flöde
kPa
l/h
10
200
0
0
20
400
30
600
40
800
50
1000
60
1200
70
1400 1600 1800 2000
l/s
0,50,40,30,20,10
Flow
l/h
l/s
Available pressure,
kPa
1
2
3
ESV 2210
GB

Outline diagram ACVM 270 with ESV 22 - extra shunt
BT 1
RG10/
RE10
Erf. säker-
hetsutr.
FL1
FQ1
CM1
GP10
Överströmnings ventil
EP21-QN25
EP21-GP20
EP21-BT2
EP21-BT3
CP1
UKV40
Required safety equipment
Overflow valve
Explanation
Buffer vessel UKVCP1Temperature sensor, outdoorBT1
Extra circulation pumpEP21-GP20Temperature sensor, supply line 2EP21-BT2
Shunt valveEP21-QN25Temperature sensor, return 2EP21-BT3
Expansion vesselCM1
11ESV 22
GB

Electrical connection ACVM 270
NOTE
All electrical connections must be carried out by an
authorised electrician.
Electrical installation and wiring must be carried out
in accordance with the stipulations in force.
ACVM 270 must not be powered when installing ESV
22.
The electrical circuit diagram is at the end of these installation
instructions.
From ESV 22
Electrical
c
onnection,
X6
EBV
AA22
AA22:X4
1. The accessory ACK 22 is installed according to the sup-
plied installation instructions.
2. The sensors are connected by twin cables (for example
EKXX or LiYY) as follows for the load monitor card
(EBV–AA22) see image below:
Use the enclosed round pin sleeves for splicing between
the 2-cables and sensors BT2and BT3.
-AA22
EBV Control Card
>-EP21
Heating System 2 (Optional)
Temp. sensor supply line 2
Temp. sensor return 2
X4
The sensor used as flow sensor (EP21-BT2) is connec-
ted to terminal AA22:X4:7 and AA22:X4:8 in the
load monitor card's lower terminal block.
-
The return line sensor (EP21-BT3) is connected to
terminal AA22:X4:5 and AA22:X4:6 on the same
card.
-
3. Connect valve actuator (EP21-QN25) as follows:
Brown cable (230 V signal) to spring terminal X6:7b-
White cable (230 V signal) to spring terminal X6:8a-
Blue cable (zero) to spring terminal X6:6b-
4. Connect circulation pump (EP21-GP20) as follows:
Blue cable (zero) to spring terminal –X6:6a-
Yellow/green cable (earth cable) to spring terminal
–X6:5a
-
Brown cable (phase) to spring terminal –X6:4a-
7
8
6
4
5
3
2
1
Electrical
connection,
X6
White
Brown
Blue
Yellow/green
Brown
Temperature sensor installation
K
Install the temperature sensor with cable ties with the heat
conducting paste and aluminium tape.
Then insulate with supplied insulation tape.
NOTE
Sensor and communication cables must not be placed
near power cables.
ESV 2212
GB

Program settings ACVM 270
႑Select “Service” in menu 8.1.1 to gain access to menus
9.0 and the sub-menus.
႑Then select “Heating”, "Heating + Cooling" or "Cooling"
in menu 9.3.4, “Heating system 2”. Menu 3.0 and its
sub-menus become accessible.
႑In the sub-menus the curve co-efficient 2, offset heat
curve 2 and min- and max levels for the flow line temper-
ature 2 are set in the same way as heat system 1 under
menu 2.0.
See “Installation and Maintenance Instructions” for NIBE
SPLIT.
13ESV 22
GB

ESV 2214
GB

MONTAGEANLEITUNG
ESV 22
Allgemeines
Dieses Zubehör kommt zum Einsatz, wenn ACVM 270 in ei-
nem Haus mit zwei verschiedenen Heizkreisen installiert ist,
die unterschiedliche Vorlauftemperaturen erfordern, z.B.
wenn ein Gebäude über Heizkörper und Fußbodenheizung
verfügt. Im folgenden Text gilt Heizkreis 1 als das System,
das die höhere Temperatur erfordert und das mit dem nor-
malen Vorlauf- bzw. Rücklaufanschluss verbunden wird. Als
Heizkreis 2 gilt das System, das mit der niedrigeren Tempera-
tur arbeitet.
Der kombinierte Wasserdurchfluss in beiden Heizkreisen darf
2050 l/h (0,57 l/s) nicht überschreiten.
HINWEIS!
Dieses Zubehör erfordert ebenfalls das Zubehör ACK
22.
Inhalt
3-Leiter-Umwälzpumpe1 St.
Kabelbinder4 St.
Wärmeleitpaste2 St.
Isolierband1 St.
Flachdichtung2 St.
Buchse4 St.
Umwälzpumpe Überwurfmutter 3 Geschwindigkei-
ten, EP21-GP20
1 St.
Kugelventil M Überwurfmutter2 St.
3-Wegeventil1 St.
Aluminiumklebeband (Abschnitte)2 St.
Fühler, EP21-BT2 (Vorlauffühler), EP21-BT3
(Rücklauffühler)
2 St.
Stellantrieb, EP21-QN251 St.
15ESV 22
DE

Rohranschluss ACVM 270
Führen Sie die Montage wie folgt durch:
႑Entleeren Sie zuerst das Wasser aus dem Heizwasserge-
fäß/Heizkreis.
႑Positionieren Sie die zusätzliche Heizungsumwälzpumpe
(EP21-GP20) an einer geeigneten Stelle außerhalb von
ACVM 270.
႑Bringen Sie das Mischventil (EP21-QN25) am Vorlauf
hinter dem ACVM 270 und vor dem ersten Heizkörperfür
Heizkreis 1 an. Verbinden Sie die Rücklaufleitung von
Heizkreis 2 mit dem Mischventil (EP21-QN25) und der
Rücklaufleitung vom Heizkreis 1 (siehe Abbildung).
႑Der Vorlauffühler (EP21-BT2) wird am Rohr nach der
Heizungsumwälzpumpe (EP21-GP20) montiert.
႑Der Rücklauffühler (EP21-BT3) wird am Rohr von Heizkreis
2 montiert.
႑Verwenden Sie bei der Fühlermontage Wärmeleitpaste
und isolieren Sie das Rohr, um eine korrekte Temperatur-
messung zu gewährleisten.
HINWEIS!
Bei einer falschen Montage kann die Funktionsweise
beeinträchtigt werden.
LEK
Mischventil, (EP21-QN25)
Anschlüsse, Ø 22 mm
LEK
Rücklauf
ACVM 270 Vorlauf
Pumpenkennliniendiagramm
Flöde
kPa
l/h
10
200
0
0
20
400
30
600
40
800
50
1000
60
1200
70
1400 1600 1800 2000
l/s
0,50,40,30,20,10
Fluss
l/h
l/s
Verfügbarer Druck,
kPa
1
2
3
ESV 2216
DE

Prinzipskizze ACVM 270 mit ESV 22 – zusätzliches Mischventil
BT 1
RG10/
RE10
Erf. säker-
hetsutr.
FL1
FQ1
CM1
GP10
Överströmnings ventil
EP21-QN25
EP21-GP20
EP21-BT2
EP21-BT3
CP1
UKV40
Erforderliche
Sicherheitsausr.
Überlaufventil
Erklärung
Pufferspeicher UKVCP1AußentemperaturfühlerBT1
Zusätzliche UmwälzpumpeEP21-GP20Fühler, Vorlauf 2EP21-BT2
MischventilEP21-QN25Fühler, Rücklauf 2EP21-BT3
AusdehnungsgefäßCM1
17ESV 22
DE

Elektrischer Anschluss ACVM 270
HINWEIS!
Alle elektrischen Anschlüsse müssen von einem befug-
ten Elektriker ausgeführt werden.
Bei der Elektroinstallation und beim Verlegen der Lei-
tungen sind die geltenden Vorschriften zu berücksich-
tigen.
ACVM 270 darf bei der Installation von ESV 22 nicht
mit Spannung versorgt werden.
Der Schaltplan befindet sich am Ende dieser Montageanlei-
tung.
Aus ESV 22
E
lektrischer
Anschluss,
X6
EBV
AA22
AA22:X4
1. Das Zubehör ACK 22 wird gemäß der beiliegenden
Montageanleitung installiert.
2. Die Fühler werden wie folgt per Zweileiter (z.B. EKXX
oder LiYY) mit der Leistungswächterkarte verbunden
(EBV–AA22) siehe Abbildung unten.
Verwenden Sie die folgenden Rundstifthülsen, um
2-Leiter sowie Fühler BT2 und BT3 zu verbinden.
-AA22
EBV-Karte
>-EP21
Heizsystem 2 (Zubehör)
Temp.fühler, Vorlauf 2
Temp.fühler, Rücklauf 2
X4
Der als Vorlauffühler verwendete Fühler (EP21-BT2)
wird mit Position AA22:X4:7 und AA22:X4:8 an der
unteren Anschlussklemme der Leistungswächterkarte
verbunden.
-
Rücklauffühler (EP21-BT3) wird mit Position
AA22:X4:5 und AA22:X4:6 an derselben Karte ver-
bunden.
-
3. Ventilstellvorrichtung (EP21-QN25) wird wie folgt ange-
schlossen:
Brauner Leiter (230-V-Signal) an Federklemme X6:7b-
Weißer Leiter (230-V-Signal) an Federklemme X6:8a-
Blauer Leiter (Nullleiter) an Federklemme X6:6b.-
4. Umwälzpumpe (EP21-GP20) wird wie folgt angeschlos-
sen:
Blauer Leiter (Nullleiter) an Federklemme -X6:6a-
Gelber/grüner Leiter (Erdleiter) an Federklemme -
X6:5a
-
Brauner Leiter (Phase) an Federklemme -X6:4a-
7
8
6
4
5
3
2
1
Elektrischer
Anschluss,
X6
Weiß
Braun
Blau
Gelb/Grün
Braun
ESV 2218
DE

Fühlermontage
K
Der Fühler wird mit Kabelbinder, Wärmeleitpaste und Alumi-
niumband angebracht.
Anschließend ist er mit dem beiliegenden Isolierband zu
umwickeln.
HINWEIS!
Fühler- und Kommunikationskabel dürfen nicht in der
Nähe von Starkstromleitungen verlegt werden.
Programmeinstellungen ACVM 270
႑Durch Auswahl von "Service" in Menü 8.1.1 erhalten Sie
Zugriff auf Menü 9.0 und die zugehörigen Untermenüs.
႑Wählen Sie anschließend “Heizung”, "Heizung + Küh-
lung" oder "Kühlung" im Menü 9.3.4, "Heizkreis 2" aus.
Dadurch erhalten Sie Zugriff auf Menü 3.0 und die zuge-
hörigen Untermenüs.
႑In den Untermenüs werden Heizkurvenverlauf 2, Parallel-
verschiebung der Heizkurve 2 sowie Minimal- und Maxi-
malwerte für Vorlauftemperatur 2 auf dieselbe Weise wie
für Heizkreis 1 unter Menü 2.0 eingestellt.
Siehe auch "Montage- und Wartungsanleitung" für NIBE
SPLIT.
19ESV 22
DE

ESV 2220
DE
Table of contents
Languages:
Other Nibe Heat Pump Accessories manuals
Popular Heat Pump Accessories manuals by other brands

Baxi
Baxi ROCA FLEXBRANE Assembly instructions

STIEBEL ELTRON
STIEBEL ELTRON WPIC-B Operating and installation

Resol
Resol SBS 2000 Manual for the specialised craftsman

Axiom
Axiom NT25-P18 Installation, operation and maintenance instructions

STIEBEL ELTRON
STIEBEL ELTRON WPSB 308 E Installation