manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Protekt
  6. •
  7. Safety Equipment
  8. •
  9. Protekt P-10R NIZE User manual

Protekt P-10R NIZE User manual

Safety harness is basic fall arrest equipment complied with EN 361. It is
also destinated to be used as a rescue harness complied with EN 1497.
Maximum load of the rescue harness is 100 kg.
DESCRIPTION
Full body harness P-10R is made of 44mm wide
webbing which is sewn and connected by metal buckles. Harness P-10R
is equipped with webbing loop for rescue equipment.
This configuration guarantees full safety and comfort work.
BASIC EQUIPMENT
!back attaching buckle - for attaching fall arrest systems
!back attaching buckle - for attaching fall arrest systems
!loop for attaching rescue equipment
!connecting and adjusting buckles - for comfort wearing and using of
harness
!front attaching buckle - for fall arrest sysytems
!rescue acces loop - for rescue equipment only
SIZES
The harness P-10R is manufactured in two sizes:
- universal: M-XL
polyamide/polyester
shoulder strap
adjusting
buckle
of the shoulder
strap
connecting
and adjusting
buckle
of the chest
strap
back attaching
buckle for attaching
fall arrest system
front attaching
buckle for attaching
fall arrest system
loop
for attaching
rescue
equipment only
do not use it
with fall arrest
equipment
connecting
and adjusting
buckle
of the thigh strap
thigh strap
SAFETY HARNESS
Ref. AB 110 03
Size:
Date
of manufacture: 03/2003
Serial
number: 0000001
M-XL
XXL
EN 361:2002
P-10R NIZE
CONTENT OF HARNESS IDENTITY LABEL
number of the manufacturing series
CE marking and number of a notified body
controlling manufacturing of the equipment (art. 11)
type of the device
reference number
month/year of the device manufacture
marking of the manufacturer
or distributor
trade mark of the device
size
EN 1497:2007
caution: read the manual
!
- trailing or looping of lanyards or lifelines over sharp edges,
- any defects like cutting, abrasion, corrosion,
- climatic exposure,
- pendulum falls,
- extremes of temperature,
- chemical reagents,
- electrical conductivity.
!personal protective equipment must be transported in the package (e.g.: bag made of moisture-proof textile or foil bag or cases made of steel or plastic) to protect it against damage or moisture.
!the equipment can be cleaned without causing adverse effect on the materials in the manufacture of the equipment. For textile products use mild detergents for delicate fabrics, wash by hand or in a
machine and rinse in water. Plastic parts can be cleaned only with water. When the equipment becomes wet, either from being in use or when due cleaning, it shall be allowed to dry naturally, and shall
be kept away from direct heat. In metallic products some mechanic parts (spring, pin, hinge, etc.) can be regularly slightly lubricated to ensure better operation.
Other maintenance and cleaning procedures should be adhered to detailed instructions stated in the manual of the equipment.
!personal protective equipment should be stored loosely packed, in a well-ventilated place, protected from direct light, ultraviolet degradation, damp environment, sharp edges, extreme temperatures and
corrosive or aggressive substances.
there are many hazards that may affect the performance of the equipment and corresponding safety precautions that have to be observed during equipment utilization, especially:
IDENTITY CARD
PERIODIC EXAMINATION AND REPAIR HISTORY
1
2
DATE
REASON FOR
ENTRY PERIODIC EXAMINATION
OR REPAIR
3
4
SERIAL NUMBER
USER NAME
DATE OF MANUF.
DATE OF PUTTING INTO OPERATION
DATE OF PURCHASE
IT IS THE RESPONSIBILITY OF THE USER ORGANISATION TO PROVIDE THE IDENTITY CARD AND TO FILL IN THE DETAILS REQUIRED.
THE IDENTITY CARD SHOULD BE FILLED IN BEFORE THE FIRST USE BY A COMPETENT PERSON, RESPONSIBLE INTHE USER ORGANIZATION FOR PROTECTIVE EQUIPMENT.
ANY INFORMATION ABOUT THE EQUIPMENT LIKE PERIODIC INSPECTIONS, REPAIRS, REASONS OF EQUIPMENT'S WITHDRAWN FROM USE SHALL BE NOTED INTO THE IDENTITY CARD BY A COMPETENT PERSON.
THE IDENTITY CARD SHOULD BE STORAGED DURING A WHOLE PERIOD OF EQUIPMENT UTILIZATION.
DO NOT USE THE EQUIPMENT WITHOUT THE IDENTITY CARD.
ALL RECORDS IN THE IDENTITY CARD CAN BE FILLED IN ONLY BY A COMPETENT PERSON.
MODEL AND TYPE OF EQUIPMENT
REF. NUMBER
DEFECTS NOTED,
REPAIRS CARRIED OUT
AND OTHER REVELANT INFORMATIONS
NAME AND SIGNATURE
OF COMPETENT PERSON PERIODIC
EXAMINATION
NEXT DUE DATE
number / year of the European standards
the equipment conform
EN 1497:2007
Ref.: AB 110 03
Instruction Manual
READ CAREFULLY BEFORE USE
THE EQUIPMENT
SAFETY
HARNESS
P-10R NIZE
EN 361:2002
ADMISSIBLE TIME OF USE
Safety harness can be used for 5 years counting from a date of putting
the harness into operation. After this period the harness
manufacturer's .
The manufacturer's inspection can be carried out by:
- manufacturer
- or person recommended by manufacturer
- or company recommended by manufacturer.
During this inspection will be established admissible time of harness use
till next manufacturer's inspection.
The harness
must be
withdrawn from use to carry out detailed inspection
must be withdrawn from use immediately and destroyed
when it has been used to arrest a fall.
EC type examination carried out by APAVE SUDEUROPE SAS, BP 3 - 33370 ARTIGUES près BORDEAUX France, no. 0082
PROTEKT, 93-403 LODZ, ul. Starorudzka 9, POLAND, TEL: (48 42) 680 20 83, FAX: 680 20 93, www.protekt.com.pl(48 42)
!
!
!
using the harness in connection with fall arrest system must be compatible with manual instructions of the fall arrest systems and obligatory
standards:
- EN353-1, EN353-2, EN355, EN354, EN360, EN362 - for the fall arrest systems;
- EN341 - for the rescue equipment.
the harness must be taken out of service and destroyed by a competent person after being used to arrest a fall.
it is strictly forbidden to make any modifications to the harness yourself.
!
!
the fall arrest system must be connected only to the attaching elements of the harness marked by capital letter A.
The fall arrest system must be connected only to the front or back attaching buckle.
The back attaching buckle is marked by a capital letter A - marked on the crossing plate with arrowsindicating back attaching buckle - 1.
The front attaching buckle is marked by a capital letter A on the label placed near the buckle - 2.
See drawings below.
ATTENTION: It is strictly forbidden to attach fall arrest system to the loop destined for attaching rescue equipment.
structural anchor point for connecting fallarrest system should be situated above the working position and should have static resistance min. 10 kN.
The shape of the structural anchor point should not let self-acting disconnection of fall arrest system.
It is recommended to use certified and marked structural anchor point complied with EN 795.
A
A
HOW TO PUT ON THE HARNESS
Harness is put on correctly if:
all straps are correctly adjusted (neither too loose nor too tight).
back attaching buckle is correctly positioned at the level of the shoulder blades.
front chest strap is correctly positioned at the middle of the chest.
the ends of all the straps must be kept by plastic loops.
Take the harness by the back attaching
buckle.
Put on the shoulder straps one after one,
take care do not twist them.
Connect chest strap buckle and adjust
the tension the chest strap.
Pull one and then other thigh straps
through crottch, take care do not twist
them.
Connecting of the steel buckles of the thigh straps and chest strap
Shortening Lengthening
Adjusting of the thigh straps and chest strap
1
9
2
10
3
11
4
12
Adjusting of the shoulder straps
Shortening Lengthening
5 6 7 8
1 2
ATTACHING FALL ARREST SYSTEM
!personal protective equipment shall only be used by a person trained and competent in its safe use.
!personal protective equipment must not be used by a person with medical condition that could affect the safety of the equipment user in normal and emergency use.
!a rescue plan shall be in place to deal with any emergencies that could arise during the work.
!it is forbidden to make any alterations or additions to the equipment without the manufacturer's prior written consent.
!any repair shall only be carried out by equipment manufacturer or his certified representative.
!personal protective equipment shall not be used outside its limitations, or for any purpose other than that for which it is intended.
!personal protective equipment should be a personal issue item.
!before use ensure about the compatibility of items of equipment assembled into a fall arrest system. Periodically check connecting and adjusting of the equipment components to avoid accidental loosening or
disconnecting of the components.
!it is forbidden to use combinations of items of equipment in which the safe function of any one item is affected by or interferes with the safe function of another.
!before each use of personal protective equipment it is obligatory to carry out a pre-use check of the equipment, to ensure that it is in a serviceable condition and operates correctly before it is used.
!during pre-use check it is necessary to inspect all elements of the equipment in respect of any damages, excessive wear, corrosion, abrasion, cutting or incorrect acting, especially take into consideration:
- in full body harnesses and belts - buckles, adjusting elements, attaching points, webbings, seams, loops;
- in energy absorbers - attaching loops, webbing, seams, casing, connectors;
- in textile lanyards or lifelines or guidelines - rope, loops, thimbles, connectors, adjusting element, splices;
- in steel lanyards or lifelines or guidelines - cable, wires, clips, ferrules, loops, thimbles, connectors, adjusting elements;
- in retractable fall arresters - cable or webbing, retractor and brake proper acting, casing, energy absorber, connector;
- in guided type fall arresters - body of the fall arrester, sliding function, locking gear acting, rivets and screws, connector, energy absorber;
- in connectors - main body, rivets, gate, locking gear acting.
!after every12 months of utilization, personal protective equipment must be withdrawn from use to carry out periodical detailed inspection. The periodic inspection must be carried out by
a competent person for periodic inspection. The periodic inspection can be carried out also by the manufacturer or his authorized representative.
In case of some types of the complex equipment e.g. some types of retractable fall arresters the annual inspection can be carried out only by the manufacturer or his authorized representative.
!regular periodic inspections are the essential for equipment maintenance and the safety of the users which depends upon the continued efficiency and durability of the equipment.
!during periodic inspection it is necessary to check the legibility of the equipment marking.
!it is essential for the safety of the user that if the product is re-sold outside the original country of destination the reseller shall provide instructions for use, for maintenance, for periodic examination and for
repair in language of the country in which the product is to be used.
!personal protective equipment must be withdrawn from use immediately when any doubt arise about its condition for safe use and not used again until confirmed in writing by equipment manufacturer or his
representative after carried out the detailed inspection.
!personal protective equipment must be withdrawn from use immediately and destroyed (or another procedures shall be introduced according detailed instruction from equipment manual) when it have been
used to arrest a fall. ,
!a full body harness is the only acceptable body holding device that can be used in a fall arrest system.
!the anchor device or anchor point for the fall arrest system should always be positioned, and the work carried out in such a way, as to minimise both the potential for falls and potential fall distance. The anchor
device/point should be placed above the position of the user . The shape and construction of the anchor device/point shall not allowed to self-acting disconnection of the equipment. Minimal static strength of
the anchor device/point is 10 kN. It is recommended to use certified and marked structural anchor point complied with EN795.
!it is obligatory to verify the free space required beneath the user at the workplace before each occasion of use the fall arrest system, so that, in the case of a fall, there will be no collision with the ground or
other obstacle in the fall path. The required value of the free space should be taken from instruction manual of used equipment.
THE ESSENTIAL PRINCIPLES FOR USERS OF PERSONAL PROTECTIVE EQUIPMENT AGAINST FALLS FROM A HEIGHT

Other Protekt Safety Equipment manuals

Protekt PB-30 User manual

Protekt

Protekt PB-30 User manual

Protekt HEXAPOD User manual

Protekt

Protekt HEXAPOD User manual

Protekt AT187 User manual

Protekt

Protekt AT187 User manual

Protekt Hebetech A-165 User manual

Protekt

Protekt Hebetech A-165 User manual

Protekt PB-10 User manual

Protekt

Protekt PB-10 User manual

Protekt IM 101 User manual

Protekt

Protekt IM 101 User manual

Protekt P-16 User manual

Protekt

Protekt P-16 User manual

Protekt TROLLEY ST012 User manual

Protekt

Protekt TROLLEY ST012 User manual

Protekt P-30N User manual

Protekt

Protekt P-30N User manual

Protekt P-01B User manual

Protekt

Protekt P-01B User manual

Protekt P-71 User manual

Protekt

Protekt P-71 User manual

Protekt CR250HV User manual

Protekt

Protekt CR250HV User manual

Protekt AZ 002 User manual

Protekt

Protekt AZ 002 User manual

Protekt AE 320 User manual

Protekt

Protekt AE 320 User manual

Protekt AT191 User manual

Protekt

Protekt AT191 User manual

Protekt WR 020 User manual

Protekt

Protekt WR 020 User manual

Protekt SP101 User manual

Protekt

Protekt SP101 User manual

Protekt PB-10 User manual

Protekt

Protekt PB-10 User manual

Protekt RJ200 User manual

Protekt

Protekt RJ200 User manual

Protekt AE 321 Series User manual

Protekt

Protekt AE 321 Series User manual

Protekt P-60 User manual

Protekt

Protekt P-60 User manual

Protekt P-56mX User manual

Protekt

Protekt P-56mX User manual

Protekt DR100 User manual

Protekt

Protekt DR100 User manual

Protekt PROTON 1 User manual

Protekt

Protekt PROTON 1 User manual

Popular Safety Equipment manuals by other brands

Protecta Rebel 3591002 quick guide

Protecta

Protecta Rebel 3591002 quick guide

ROOM VALET Visual Alerting System instructions

ROOM VALET

ROOM VALET Visual Alerting System instructions

Lyon LBSKT BRW User instructions

Lyon

Lyon LBSKT BRW User instructions

Clarke SV1B quick start guide

Clarke

Clarke SV1B quick start guide

Tractel rollclamp Installation, operating and maintenance manual

Tractel

Tractel rollclamp Installation, operating and maintenance manual

turck IMXK12-AI01 Series quick start guide

turck

turck IMXK12-AI01 Series quick start guide

Indemnis Nexus Mini Operation guide

Indemnis

Indemnis Nexus Mini Operation guide

Pilz PNOZ mo5p operating manual

Pilz

Pilz PNOZ mo5p operating manual

PMI HD26232 quick start guide

PMI

PMI HD26232 quick start guide

Chloride SGLO Installation and operating instructions

Chloride

Chloride SGLO Installation and operating instructions

Viking PS73 Series User instruction

Viking

Viking PS73 Series User instruction

Innova XTIRPA IN-8008 Instruction and safety manual

Innova

Innova XTIRPA IN-8008 Instruction and safety manual

Ultra-safe UT-97516 User instruction manual

Ultra-safe

Ultra-safe UT-97516 User instruction manual

DINA SAFELINE VARIO instruction manual

DINA

DINA SAFELINE VARIO instruction manual

Panlux FENIX FXE-9001-C instructions

Panlux

Panlux FENIX FXE-9001-C instructions

Standers L211-4 Assembly, Use, Maintenance Manual

Standers

Standers L211-4 Assembly, Use, Maintenance Manual

MSA PremAire System CARRIER AND HARNESS ASSEMBLY

MSA

MSA PremAire System CARRIER AND HARNESS ASSEMBLY

ABS ABS-Lock X-H-16-SR manual

ABS

ABS ABS-Lock X-H-16-SR manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.