1. Shoulder strap.
2. Shoulder strap adjusting buckle.
3. Frontal attachment D-ring - for attaching fall arrest
system.
4. Connecting snap hook.
5. Frontal waist attachment buckle - can be utilized as
a sit harness according EN 813 (it's not allowed to
use this buckle to attach fall arrest system).
6. Lateral belt attachment D-rings. Can be utilized only
to attach work positioning systems according
EN 358.
7. Work positioning belt strap.
8. Work positioning belt strap adjusting buckles.
9. Thigh straps.
10. Thigh straps connecting/adjusting buckles.
11. Dorsal attachment D-ring - for attaching fall arrest
system.
12. Crossing plate.
13. Dorsal strap adjusting buckle.
14. Belt pad.
15. Tool Plastic D-rings.
16. Tool Loops.
17. Identity label
SAFETY HARNESS
Ref. AB 171 01
Size:
M-XL
XXL
P-71
Date of manufacture:
12.2011
Serial number:
0000001
b
a c d
efghi
j
a-Device type, b-Model symbol, c-Reference
number, d-number/year European standards
e-CE mark and number of the notified body
controlling manufacturing of the equipment,
f- Month and year of manufacture, g-Serial
number of the harness, h-Harness size,
i-Caution: read the manual, j- identification of
the harness manufacturer or distributor.
k - max. weight for the sit harness use.
HARNESS MARKING
SIZES
The harness is manufactured in two sizes:
- medium and extra large size - M-XL
- extra large -XXL
7
,
!a full body harness (conforming to EN 361) is the only acceptable body holding device that can be used in a fall arrest system.
!in full body harness use only attaching points marked with big letter "A" to attach a fall arrest system.
!the anchor device or anchor point for the fall arrest system should always be positioned, and the work carried out in such a way, as to minimise both the
potential for falls and potential fall distance. The anchor device/point should be placed above the position of the user . The shape and construction of
the anchor device/point shall not allowed to self-acting disconnection of the equipment. Minimal static strength of the anchor device/point is 10 kN. It is
recommended to use certified and marked structural anchor point complied with EN795
!it is obligatory to verify the free space required beneath the user at the workplace before each occasion of use the fall arrest system, so that, in the case
of a fall, there will be no collision with the ground or other obstacle in the fall path. The required value of the free space should be taken from instruction
manual of used equipment.
!there are many hazards that may affect the performance of the equipment and corresponding safety precautions that have to be observed during
equipment utilization, especially: - trailing or looping of lanyards or lifelines over sharp edges, - any defects like cutting, abrasion, corrosion, - climatic
exposure, - pendulum falls, - extremes of temperature, - chemical reagents, - electrical conductivity.
!personal protective equipment must be transported in the package (e.g.: bag made of moisture-proof textile or foil bag or cases made of steel or plastic)
to protect it against damage or moisture.
!the equipment can be cleaned without causing adverse effect on the materials in the manufacture of the equipment. For textile products use mild
detergents for delicate fabrics, wash by hand or in a machine and rinse in water. Plastic parts can be cleaned only with water. When the equipment
becomes wet, either from being in use or when due cleaning, it shall be allowed to dry naturally, and shall be kept away from direct heat. In metallic
products some mechanic parts (spring, pin, hinge, etc.) can be regularly slightly lubricated to ensure better operation.
Other maintenance and cleaning procedures should be adhered to detailed instructions stated in the manual of the equipment.
!personal protective equipment should be stored loosely packed, in a well-ventilated place, protected from direct light, ultraviolet degradation, damp
environment, sharp edges, extreme temperatures and corrosive or aggressive substances.
EN 361:2002
EN 358:1999
EN 813:2008
Instruction Manual
READ CAREFULLY BEFORE USE THE EQUIPMENT
SAFETY HARNESS
P-71
EN 358:1999
EN 361:2002
5
Safety harness is the basic
element of fall arrest
equipment.
The harness P-71/P-71E/P-
71C complies with EN 361
(as a full body harness),
EN 358 (as a work
positioning belt) and EN
813 (as a sit harness) - the
maximum load of the sit
harness is 100 kg.
The harness is made of
polyamide webbings.
Models:
- P-71 - basic version.
- P-71E - elasticated
shoulder's strap.
- P-71C - quick release
buckles in the legs.
EN 813:2008
max. load 100 kg
Ref. AB 171 01
P-71E
Ref. AB 171 02
P-71C
P-71EC
Ref. AB 171 03 Ref. AB 171 04
IDENTITY CARD
SERIAL NUMBER
USER NAME
DATE OF MANUF.
DATE OF PUTTING
INTO OPERATION
DATE OF PURCHASE
IT IS THE RESPONSIBILITY OF THE USER ORGANISATION TO PROVIDE THE IDENTITY CARD AND TO FILL IN THE DETAILS REQUIRED. THE IDENTITY CARD SHOULD BE FILLED IN BEFORE THE FIRST
USE BY A COMPETENT PERSON, RESPONSIBLE INTHE USER ORGANIZATION FOR PROTECTIVE EQUIPMENT. ANY INFORMATION ABOUT THE EQUIPMENT LIKE PERIODIC INSPECTIONS, REPAIRS,
REASONS OF EQUIPMENT'S WITHDRAWN FROM USE SHALL BE NOTED INTO THE IDENTITY CARD BY A COMPETENT PERSON. THE IDENTITY CARD SHOULD BE STORAGED DURING A WHOLE
PERIOD OF EQUIPMENT UTILIZATION. DO NOT USE THE EQUIPMENT WITHOUT THE IDENTITY CARD. ALL RECORDS IN THE IDENTITY CARD CAN BE FILLED IN ONLY BY A COMPETENT PERSON.
MODEL AND TYPE OF EQUIPMENT
REF. NUMBER
PERIODIC EXAMINATION AND REPAIR HISTORY
DATE
REASON FOR
ENTRY PERIODIC EXAMINATION
OR REPAIR
DEFECTS NOTED,
REPAIRS CARRIED OUT
AND OTHER REVELANT INFORMATIONS
NAME AND SIGNATURE
OF COMPETENT PERSON
PERIODIC
EXAMINATION
NEXT DUE DATE
1
2
3
4
PROTEKT, 93-403 LODZ,
ul. Starorudzka 9, POLAND,
TEL: (48 42) 680 20 83, FAX: (48 42) 680 20 93
www.protekt.com.pl
Notified body, at which the European certification
was performed and which supervises
the production of the equipment:
APAVE SUDEUROPE SAS - BP 193 - 13322 MARSEILLE CEDEX 16 - FRANCE
A
2
3
112
11
k
!Fall arrest system must be connected only to the attaching elements of the harness marked by
capital letter A. The fall arrest system must be connected only to: - dorsal attachment D-ring -
drawing (1) or - to frontal attachment D-ring. The dorsal attachment D-ring is marked by a
capital letter A - embossed on the crossing plate. Front attachment D-ring is marked by a
capital letter A placed on the label sewn near the D-ring . See drawings.
PUTTING ON THE HARNESS
Fastening the straps
Adjusting the straps
Tightening
Loosening
ATTENTION:
Always protect free end of the strap with the loop
protecting belt strap
protecting thigh strap
1
Harness is put on correctly if:
all straps are correctly adjusted (neither too loose nor too tight).
back attaching buckle is correctlypositioned at the level of the shoulder blades.
front connecting snap hook is correctlypositioned at the middle of the chest.
the ends of the all straps must be kept by plastic loops.
!work positioning system can be attached only to the lateral buckles of the work positioning
belt or to the frontal waist buckle - work positioning lanyard must be anchored to the point of
construction that is situated at waist level or above.
Work positioning lanyard must be kept taut to restrict free movement to a maximum 0,6 m.
!personal protective equipment shall only be used by a person trained and competent in its safe use.
!personal protective equipment must not be used by a person with medical condition that could affect the safety of the equipment user in normal and emergency use.
!a rescue plan shall be in place to deal with any emergencies that could arise during the work.
!being suspended in PPE (e.g. arresting a fall), beware of suspension trauma symptoms.
!to avoid symptoms of suspention trauma, be sure that the proper rescue plan is ready for use. It is recommended to use foot straps.
!it is forbidden to make any alterations or additions to the equipment without the manufacturer's prior written consent.
!any repair shall only be carried out by equipment manufacturer or his certified representative.
!personal protective equipment shall not be used outside its limitations, or for any purpose other than that for which it is intended.
!personal protective equipment should be a personal issue item.
!before use ensure about the compatibility of items of equipment assembled into a fall arrest system. Periodically check connecting and adjusting of the equipment
components to avoid accidental loosening or disconnecting of the components.
!it is forbidden to use combinations of items of equipment in which the safe function of any one item is affected by or interferes with the safe function of another.
!before each use of personal protective equipment it is obligatory to carry out a pre-use check of the equipment, to ensure that it is in a serviceable condition and
operates correctly before it is used.
!during pre-use check it is necessary to inspect all elements of the equipment in respect of any damages, excessive wear, corrosion, abrasion, cutting or incorrect
acting, especially take into consideration:
- in full body harnesses and belts - buckles, adjusting elements, attaching points, webbings, seams, loops;
- in energy absorbers - attaching loops, webbing, seams, casing, connectors;
- in textile lanyards or lifelines or guidelines - rope, loops, thimbles, connectors, adjusting element, splices;
- in steel lanyards or lifelines or guidelines - cable, wires, clips, ferrules, loops, thimbles, connectors, adjusting elements;
- in retractable fall arresters - cable or webbing, retractor and brake proper acting, casing, energy absorber, connector;
- in guided type fall arresters - body of the fall arrester, sliding function, locking gear acting, rivets and screws, connector, energy absorber;
- in connectors - main body, rivets, gate, locking gear acting.
!after every12 months of utilization, personal protective equipment must be withdrawn from use to carry out periodical detailed inspection. The periodic inspection
must be carried out by a competent person for periodic inspection. The periodic inspection can be carried out also by the manufacturer or his authorized
representative.
In case of some types of the complex equipment e.g. some types of retractable fall arresters the annual inspection can be carried out only by the manufacturer or
his authorized representative.
!regular periodic inspections are the essential for equipment maintenance and the safety of the users which depends upon the continued efficiency and durability of
the equipment.
!during periodic inspection it is necessary to check the legibility of the equipment marking.
!it is essential for the safety of the user that if the product is re-sold outside the original country of destination the reseller shall provide instructions for use, for
maintenance, for periodic examination and for repair in language of the country in which the product is to be used.
!personal protective equipment must be withdrawn from use immediately when any doubt arise about its condition for safe use and not used again until confirmed
in writing by equipment manufacturer or his representative after carried out the detailed inspection.
!personal protective equipment must be withdrawn from use immediately and destroyed (or another procedures shall be introduced according detailed instruction
from equipment manual) when it have been used to arrest a fall.
THE ESSENTIAL PRINCIPLES FOR USERS OF PERSONAL PROTECTIVE EQUIPMENT AGAINST FALLS FROM A HEIGHT
WARNING:
1) It is strictly forbidden to attach any fall arrest system to side buckle of work positioning belt.
2) It is strictly forbidden to attach any fall arrest system to frontal buckle designed for use as a sit harness according EN 813.
ATTACHING FALL ARREST SYSTEM
ADMISSIBLE TIME OF USE
Safety harness can be used for 5 years. After this period the harness manufacturer's
The manufacturer's inspection can be carried out by:
- manufacturer
- or person recommended by manufacturer
- or company recommended by manufacturer.
During this inspection will be established admissible time of harness use till next manufacturer's inspection.
must be withdrawn from use to carry out detailed
inspection
ATTENTION: Before use the belt the first time the user should
carry out a suspension test in a safe place to ensure that the
sit harness is the correct size, has sufficient adjustment and is
of an acceptable comfort
level for the intended use.
A B C D E
A. Take the harness by the shoulder
straps. Disconnect shoulder straps
from connecting hook [Y].
B. Move the straps over the head.
Taking the harness by the belt,
put them on over the feet.
C.
to connecting hook [Y].
Connect shoulder straps D. Adjust the belt strap.
Necessarily protect free ends
of the straps with the loops.
Adjust the shoulder straps.
E. Fasten and adjust the thigh
straps. Necessarily protect
free ends of the straps with
the loops.
Y
Y
1
2
3
1
2
3
1
1
2
Opening
2

This manual suits for next models

6

Other Protekt Safety Equipment manuals

Protekt AT187 User manual

Protekt

Protekt AT187 User manual

Protekt CR250HV User manual

Protekt

Protekt CR250HV User manual

Protekt AZ411 User manual

Protekt

Protekt AZ411 User manual

Protekt Hebetech A-165 User manual

Protekt

Protekt Hebetech A-165 User manual

Protekt PROTON 1 User manual

Protekt

Protekt PROTON 1 User manual

Protekt P-30N User manual

Protekt

Protekt P-30N User manual

Protekt RJ200 User manual

Protekt

Protekt RJ200 User manual

Protekt AE 321 Series User manual

Protekt

Protekt AE 321 Series User manual

Protekt IM 101 User manual

Protekt

Protekt IM 101 User manual

Protekt WR 020 User manual

Protekt

Protekt WR 020 User manual

Protekt RJ 500 User manual

Protekt

Protekt RJ 500 User manual

Protekt PB-10 User manual

Protekt

Protekt PB-10 User manual

Protekt HEXAPOD User manual

Protekt

Protekt HEXAPOD User manual

Protekt SP101 User manual

Protekt

Protekt SP101 User manual

Protekt PROT-4 User manual

Protekt

Protekt PROT-4 User manual

Protekt P-10R NIZE User manual

Protekt

Protekt P-10R NIZE User manual

Protekt P-01B User manual

Protekt

Protekt P-01B User manual

Protekt PB-10 User manual

Protekt

Protekt PB-10 User manual

Protekt P-56mX User manual

Protekt

Protekt P-56mX User manual

Protekt AT191 User manual

Protekt

Protekt AT191 User manual

Protekt DR100 User manual

Protekt

Protekt DR100 User manual

Protekt P-60 User manual

Protekt

Protekt P-60 User manual

Protekt AE 320 User manual

Protekt

Protekt AE 320 User manual

Protekt TROLLEY ST012 User manual

Protekt

Protekt TROLLEY ST012 User manual

Popular Safety Equipment manuals by other brands

Emtec WorkSafe Safe Spacer manual

Emtec

Emtec WorkSafe Safe Spacer manual

Great Land Rescue Laser Light user guide

Great Land

Great Land Rescue Laser Light user guide

DELTA PLUS COBRA4 S3 SRC User instructions

DELTA PLUS

DELTA PLUS COBRA4 S3 SRC User instructions

DELTA PLUS MOONLIGHT MOONLJA quick start guide

DELTA PLUS

DELTA PLUS MOONLIGHT MOONLJA quick start guide

Abus JC9100 ERIC Assembly and operating instructions

Abus

Abus JC9100 ERIC Assembly and operating instructions

Rf-t KAMOUFLAGE P manual

Rf-t

Rf-t KAMOUFLAGE P manual

ABS ABS-Lock X-H-16 Series instructions

ABS

ABS ABS-Lock X-H-16 Series instructions

Innotech MOBI instruction manual

Innotech

Innotech MOBI instruction manual

Safety Xpress BOLSM114SS PRODUCT INFORMATION & INSTALLATION GUIDE

Safety Xpress

Safety Xpress BOLSM114SS PRODUCT INFORMATION & INSTALLATION GUIDE

Petzl VIZIR manual

Petzl

Petzl VIZIR manual

Bodypoint EvoFlex EBE100 Installation and user instructions

Bodypoint

Bodypoint EvoFlex EBE100 Installation and user instructions

ProMobility M28 Harness user guide

ProMobility

ProMobility M28 Harness user guide

SAR Quadpod user guide

SAR

SAR Quadpod user guide

Endress+Hauser RN42 operating instructions

Endress+Hauser

Endress+Hauser RN42 operating instructions

KStrong AFX201001 User instruction manual

KStrong

KStrong AFX201001 User instruction manual

schmersal SRB 324ST/R V.3 operating instructions

schmersal

schmersal SRB 324ST/R V.3 operating instructions

MAS BFD 3 operating instructions

MAS

MAS BFD 3 operating instructions

bolle SAFETY TRYON RX quick start guide

bolle SAFETY

bolle SAFETY TRYON RX quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.