INSTRUCTIONS
T8 LED SIGN TUBE
RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install
and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected]
IMPORTANT
READ CAREFULLY BEFORE INSTALLING TUBES. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB LED tubes must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is
required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON
FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
PARTS/COMPONENTS INCLUDED IN KIT
KIT IS COMPLETE ONLY WHEN ALL PARTS REQUIRED BY THE INSTRUCTIONS ARE PRESENT.
WIRING DIAGRAM
Endcap with L
mark
AC Input
Connect
Live wire
to this side
Connect
Neutral wire
to this side
Endcap with N
mark
- Installation Instructions 10pcs/carton
- LED Lamp 10pcs/carton
- Luminaire Marking Labels 10pcs/carton
WARNINGS:
• Risk of electric shock - Do not use where directly exposed to water.
• Risk of re or electric shock - LED Retrofit Kit installation requires knowledge of sign electrical systems. If not qualified, do not
attempt installation. Contact a qualified electrician.
• Risk of re or electric shock - Install this kit only in host signs that have been identified in the installation instructions and where
the input rating of the retrofit kit does not exceed the input rating of the sign.
• Risk of re or electric shock - Installation of this LED retrofit kit may involve drilling or punching of holes into the structure
of the sign. Check for enclosed wiring and components to avoid damage to wiring and electrical parts.
• Prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
• Installers should not disconnect existing wires from lampholder terminals to make new connections at lampholder terminals.
Instead installers should cut existing lampholder leads away from the lampholder and make new electrical connections to
lampholder lead wires by employing applicable connectors.
• Installers should examine all parts that are not intended to be replaced by the retrofit kit for damage and replace any
damaged parts prior to installation of the retrofit kit.
• Repair and seal any unused openings in the electrical enclosure. Openings greater than 12.7-mm (1/2-in) diameter require a metal
patch secured by screws or rivets and caulked with non-hardening caulk. Smaller openings may be sealed with non-hardening caulk.
SAFETY INFORMATION:
For your and others’ safety, please read the precaution carefully before installation:
- Always keep AC supply off during installation.
- The light source contained in this luminaire shall only be replaced by the manufacturer, its service agent, or a similar qualified person.
- Not for use with dimmers.
- This product is not intended for use with emergency exits.
- Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.
- The electrical rating is 120-277Vac, the installer must determine whether they have 120-277Vac at the luminaire before installation.
GENERAL PURPOSE
RETROFIT SIGN
CONVERSION
FOR USE ONLY
IN ACCORDANCE WITH
KIT INSTRUCTIONS
KIT IS COMPLETE ONLY WHEN ALL PARTS
REQUIRED BY THE INSTRUCTIONS ARE PRESENT
INSTALLATION INSTRUCTIONS
INSTRUCTIONS
T8 LED SIGN TUBE
RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install
and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected]
Align the two laser marks
Align the two laser marks
Fig.1
1. Make sure POWER IS OFF, remove diffuser
(If applicable), fluorescent tubes, lens and wiring if
applicable.
2. Confirm that the Lamp Holders in the fixture are in
good shape and are bi-pin R17D Lamp Holders.
3. Access sign raceway/wiring box. Ballast
configuration should be similar to one of the
diagrams.
INSTALLATION INSTRUCTIONS (Cont’d)
4. Remove the all leads of the electronic ballast in
the previous luminaire. Cut as far away from the
lamp holders to allow for longer lengths of wire
at both lamp holders (Note: Ballast must be
retained in place.)
5. If a disconnect switch is integral to the disconnect
ballast, the disconnect switch will need to be
relocated and mounted to a visible location on the
sign. Make sure the electrical rating of the switch or
circuit breaker is not exceeded. See “Mounting
Instructions for Disconnect Switch”
6. Confirm that power is still disconnected from fixture
and fixture is properly grounded.
7. Follow the step below to install single lamp or
multiple lamps
Single Lamp
Multiple Lamps
8. Complete all electrical connections with
appropriate connectors/wire nuts as needed, per
all local and national electrical codes.
9. Install Sign tubes, Align laser marks. (Fig.1)
Cut wires
Cut wires
Connect with wire nuts
Cut wiresCut wires
Black
Parallel Series
White
Ground
Blue
Blue
Blue
Blue
Blue
Blue
Blue
Blue
Red
Red
Blue
Blue
Orange/Black
Orange/Black
Orange
Orange
Red
Red
White
Black
Line
Brown
Brown
Blue/White
Blue/White
Yellow
Yellow
Black (Line) Black (Line)
White (Neutral) White (Neutral)
Parallel Series
Connect the line AC wire to one lampholder and the
neutral AC wire to lampholder on the opposite end.
If only one lamp is being, proceed to step 8.
Rewire the fixture using existing lampholders as
shown below according to the original ballast wiring
configuration. Maximum 8 tubes used.
Note: Ensure the minimum spacing between the side
and side of the lamp is 85mm (3.35 in.)
Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.
10. Connect Live and Neutral wires accordingly. (Fig.2)
Endcap with L
mark
AC Input
Connect
Live wire
to this side
Connect
Neutral wire
to this side
Endcap with N
mark
Fig.2
INSTRUCTIONS
T8 LED SIGN TUBE
RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install
and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected]
11. Attach the Luminaire Marking Label to the luminaire.
Assemble the tubes into the R17D Lamp Holders.
(Fig.3)
Fig.3
12. Rotate the tubes from 0° to 90° to get the best
illumination. (Fig.4)
Fig.4
13. Reinstall diffuser (if applicable) to complete the
assembly. (Fig.5)
INSTALLATION INSTRUCTIONS (Cont’d)
Fig.5
Base Board
R17D Lamp Holder
Follow the measurements on Table 1
INSTALLATION INSTRUCTIONS (Cont’d)
MOUNTING INSTRUCTIONS FOR
DISCONNECT SWITCH (IF APPLICABLE)
14. Apply power to fixture and check for illumination.
1. Install at a location at or near the point of each
supply connection of sign
2. Switch shall have a manual actuator which shall be
protected against mechanical injury and shall be
operable before entering the electrical enclosure
3. Switch shall open all ungrounded conductors
4. Switch shall be marked with the ON and OFF
positions
5. Switch shall have no energized parts (primary)
accessible to contact when in the OFF position, and
6. Switch shall not be of the solid-state type.
7. Switch shall be suitable for wet location use or
provided with a wet-location switch boot if
mounted to an outdoor rated sign
T8 LED SIGN TUBE
Easy Answers
rablighting.com
Visit our website for product info
Tech Help Line
Call our experts: 888 722-1000
e-mail
Answered promptly - sales@rablighting.com
Free Lighting Layouts
Answered online or by request
© 2019 RAB LIGHTING Inc.
Northvale, New Jersey 07647 USA
RAB WARRANTY: RAB’s warranty is subject to all terms and conditions found at rablighting.com/warranty.
INSTRUCTIONS
T8 LED SIGN TUBE
RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install
and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected]
DIMENSIONAL DRAWING (inch)
ACCESSORY INSTALLATION - CABLE KIT
1. Attach the Magnetic Mounting Bracket to the top of the
inside of the light box.
2. Adjust the Self-Clamping Tension Lock up or down the
Cable Wire according to your preferred height. (Fig.6)
3. Insert the Tube Light through the
(Fig.7)
Lamp-Holding C-Clip.
Magnetic mounting bracket
Hook
Cable wire
Self-clamping tension lock
Lamp-holding C-clip
Lamp
Application : for horizontal applications over 8’ long
Ø
L1
L2
L1 ( )
L2 ( )
1.5ft 2ft 3ft 4ft 5ft 6ft 7ft 8ft 9ft 10ft
ACCESSORY INSTALLATION
- SURGE PROTECTIVE DEVICE (OPTIONAL)
Installation drawing
Fig.7
Fig.6

Other RAB Lighting Equipment manuals

RAB PLC-9-V-8XX-BYP User manual

RAB

RAB PLC-9-V-8XX-BYP User manual

RAB X34 User manual

RAB

RAB X34 User manual

RAB TOMO- 2FT User manual

RAB

RAB TOMO- 2FT User manual

RAB PLL-14-8 DIR Series User manual

RAB

RAB PLL-14-8 DIR Series User manual

RAB DRI-21-EMGR-DC-D10 User manual

RAB

RAB DRI-21-EMGR-DC-D10 User manual

RAB T5HE-10-24P-8-EXT Series User manual

RAB

RAB T5HE-10-24P-8-EXT Series User manual

RAB FIELD-ADJUSTABLE TOMO-2 User manual

RAB

RAB FIELD-ADJUSTABLE TOMO-2 User manual

RAB STRING-50 User manual

RAB

RAB STRING-50 User manual

RAB HAZL34-40 User manual

RAB

RAB HAZL34-40 User manual

RAB GOTCHA PLUS GT500 User manual

RAB

RAB GOTCHA PLUS GT500 User manual

RAB STEALTH 360 User manual

RAB

RAB STEALTH 360 User manual

RAB STL360HB/L User manual

RAB

RAB STL360HB/L User manual

RAB LESLIE User manual

RAB

RAB LESLIE User manual

RAB SHARK - 8FT User manual

RAB

RAB SHARK - 8FT User manual

RAB STRINGER34 User manual

RAB

RAB STRINGER34 User manual

RAB X17 XFU 60W User manual

RAB

RAB X17 XFU 60W User manual

RAB GUS- 2FT User manual

RAB

RAB GUS- 2FT User manual

RAB EM-2H2RNY User manual

RAB

RAB EM-2H2RNY User manual

RAB EZPAN HE 1X4 User manual

RAB

RAB EZPAN HE 1X4 User manual

RAB EM User manual

RAB

RAB EM User manual

RAB SWISHFA -2X2 User manual

RAB

RAB SWISHFA -2X2 User manual

RAB Lightcloud Controller Mini User manual

RAB

RAB Lightcloud Controller Mini User manual

RAB STL200H/L User manual

RAB

RAB STL200H/L User manual

RAB SMSLES2X13 User manual

RAB

RAB SMSLES2X13 User manual

Popular Lighting Equipment manuals by other brands

B-K lighting RE1 installation instructions

B-K lighting

B-K lighting RE1 installation instructions

Heitronic 38185 installation instructions

Heitronic

Heitronic 38185 installation instructions

Chauvet DJ Bob LED H3 Quick reference guide

Chauvet DJ

Chauvet DJ Bob LED H3 Quick reference guide

Light Emotion DERBY2 User & installation manual

Light Emotion

Light Emotion DERBY2 User & installation manual

Precision Lighting Domino Basis Track Series instruction manual

Precision Lighting

Precision Lighting Domino Basis Track Series instruction manual

HERA 3D VERTICAL TUBE RGB SERIES User manual & installation guide

HERA

HERA 3D VERTICAL TUBE RGB SERIES User manual & installation guide

Denver LBF-405 user manual

Denver

Denver LBF-405 user manual

Armacost Lighting RibbonFlex Pro quick start guide

Armacost Lighting

Armacost Lighting RibbonFlex Pro quick start guide

Carson Magnivisor Deluxe CP-60 quick start guide

Carson

Carson Magnivisor Deluxe CP-60 quick start guide

Hella LED LIGHT BAR 470 SINGLE TWIN Installation instruction

Hella

Hella LED LIGHT BAR 470 SINGLE TWIN Installation instruction

lap 48429 Installation and safety instructions

lap

lap 48429 Installation and safety instructions

Ikan Piatto Lights PL60 quick start guide

Ikan

Ikan Piatto Lights PL60 quick start guide

Westcott 4896 Setup instructions

Westcott

Westcott 4896 Setup instructions

Robe ROBIN iPointe65 user manual

Robe

Robe ROBIN iPointe65 user manual

werma 853 manual

werma

werma 853 manual

Avenger Crosspole Instructions and applications

Avenger

Avenger Crosspole Instructions and applications

Paramount Fitness ECO POOL 006-527-6316 Series Installation

Paramount Fitness

Paramount Fitness ECO POOL 006-527-6316 Series Installation

V-TAC VT-1143 Installation instruction

V-TAC

V-TAC VT-1143 Installation instruction

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.