REMS Mini Cobra User manual

PIPE & SEWER
INSTRUCTION MANUAL
REMS Mini Cobra

2
Fig. 2
10
9
8
6
5
7
4
Fig. 1
3
10
1
2
11
6

3
Translation of the Original Instruction Manual
General Safety Instructions for power tools
WARNING
WARNING
Read all the s
afet
y notes, instructions, illustrations and technical data which
come with this power tool.
Failure to heed the following instructions can lead to
electric shock, fi re and/or severe injuries.
Keep all safety notes and instructions for the future.
The term "power tool" used in the safety notes refers to mains operated power tools
(with power cable).
1) Work area safety
a) Keep work area clean an
d w
ell lit.
Untidiness or poorly lit working areas can
lead to accidents.
b) Do not operate power tools in explosive atmospheres, such as in the pres-
ence of fl ammable liquids, gases or dust.
Power tools create sparks which
may ignite the dust or fum
es.
c) Keep children and bystanders away while operating a power tool.
Distrac-
tions can cause you to lose control.
2) Electrical safety
a) Power tool plugs mu
st match the outlet. Never modify the plug in any way.
Do not use any adapter plugs with earthed (grounded) power tools.
Unmod-
ifi ed plugs and matching outlets will reduce risk of electric shock.
b) Avoid body contact with earthed or grounded surfaces, such as pipes,
radiators, ranges and refrigerators.
There is an increased risk of electric shock
if your body is earthed or grounded.
c) Do not expose power tools to rain or wet conditions.
Water entering a power
tool will increase the risk of electric shock.
d) Do not misuse the connecting cable to carry or hang up the power tool or
to pull the plug out of the socket. Keep the connecting cable away from
heat, oil, sharp edges or moving tool parts.
Damaged or knotted cables
increase the risk of electric shock.
e) When operating a power tool o
utdoors, use an extension cord suitable for
outdoor use.
Use of a cord suitable for outdoor use reduces the risk of electric
shock.
f) If operating a power tool in a damp location is unavoidable, use a residual
current device (RCD) protected supply.
Use of an RCD reduces the risk of
electric shock.
3) Personal safety
a) Stay alert, watch what you are doing and use common sense when operating
a power tool. Do not use a power tool while you are tired or under the infl u-
ence of drugs, alcohol or medication.
A moment of inattention while operating
power tools may result in serious personal injury.
b) Use personal protective equipment. Always wear eye protection.
Protective
equipment such as dust mask, non-skid safety shoes, hard hat, or hearing protec-
tion used for appropriate conditions will reduce personal injuries.
c) Prevent unintentional starting. Ensure the switch is in the off-position before
connecting to power
source, picking up or carrying the tool.
Carrying power
tools with your fi nger on the switch or energising power tools that have the switch
on invites accidents.
d) Remove any adjusting key or wrench before turning the power tool on.
A
wrench or a key left attached to a rotating part of the power tool may result in
personal injury.
e) Do not overreach. Keep proper footing and balance at all times.
This enables
better control of the power tool in unexpected situations.
f) Dress properly. Do not wear loose clothing
or jewellery. Keep your hair,
clothing and gloves away from moving parts.
Loose clothes, jewellery or long
hair can be caught in moving parts.
g) Do not take your safety for granted and ignore the safety rules for power
tools even if you are very familiar with the power tool after frequent use.
Careless handling can lead to severe injury within split seconds.
4) Power tool use and care
a) Do not force
the power tool. Use the correct power tool for your application.
The correct power tool will do the job better and safer at the rate for which it was
designed.
b) Do not use the power tool if the switch does not turn it on and off.
Any power
tool that cannot be controlled with the switch is dangerous and must be repaired.
c) Disconnect the plug from the power source before making any adjustments,
changing acces
sories, or storing power tools.
Such preventive safety meas-
ures reduce the risk of starting the power tool ac
cidentally.
d) Store idle power tools out of the reach of children and do
not allow persons
unfamiliar with the power tool or these instructions to operate the power
tool.
Power tools are dangerous in the hands of untrained users.
e) Maintain power tools. Check for misalignment or binding of moving parts,
breakage of parts and any other condition that may affect the power tool’s
operation. If damaged, have the power tool repaired by qualifi ed technical
personnel or an authorised REMS service shop before use.
Many accidents
are caused by poorly maintained power tools.
f) Keep cutting tools sharp and clean.
Properly maintained cutting tools with
sharp cutting edges are less likely to bind and are easier to control.
g) Use the power tool, accessories and tool bits etc. in accordance with these
instructions, taking into account the working conditions and the work to
be performed.
Use of the power tool for operations different from those intended
could result in a hazardous situation.
h) Keep handles and gripping surfaces dry, clean and free from oil and grease.
Slippery handles and gripping surfaces prevent safe handling and control of the
power tool in unforeseeable situations.
5) Service
a) Have your power tool serviced by a qualifi ed repair person using only
identical replacement parts.
This will ensure that the safety of the power tool
is maintained.
Safety instructions for electric pipe cleaning machines
WARNING
WARNING
Read all the safety notes, instructions, illustrations and technical data which
come with this power tool.
Failure to heed the following instructions can lead to
electric shock, fi re and/or severe injuries.
Keep all safety notes and instructions for the future.
REMS Mini-Cobra
A
●
Observe the reaction torque of the drive unit to the spiral drum (10) and
operate the electric pipe cleaning machine only with both hands on the
thrust handle (1) and switch handle (2).
There is a risk of injury.
●
Only operate the electric pipe cleaning machine off the mains using a 30 mA
fault current protected switch (FI breaker).
There is a danger of electric shock.
●
Check the power cable of the electric pipe cleaning device and the exten-
sion leads regularly for damage.
Have these renewed by qualifi ed experts or
an authorised REMS customer service workshop in case of damage.
●
When the spiral runs back into the spiral drum (10), make sure that the
drive unit is switched off before the club head of the spiral runs into the
thrust gear (11).
The club head (6) will otherwise be damaged and useless.
●
Pay attention to the distance from the end of the pipe to the thrust gear
(
11
).
The cleaning spiral can whiplash if the distance is too great (> 200 mm).
There is a risk of injury!
●
Never let the pipe cleaning spiral run out of the thrust gear (
11
) without
feeding it into a pipe to be cleaned.
The pipe cleaning spiral can whiplash.
There is a risk of injury.
●
Wear rubber-soled shoes, e.g. Wellington boots, when working with the
electric pipe cleaning machine on a wet fl oor.
These shoes have an insulating
effect and protect against possible electric shock.
●
Do not use the electric pipe cleaning machine if it is damaged.
There is a
danger of accident.
●
Keep water away from electrical parts of the electric pipe cleaning machine
and from persons in the working area.
There is a danger of electric shock.
●
It could hit concealed electric cables when cleaning pipes, e.g. if the pipe
is damaged.
There is a danger of electric shock.
●
Never let the electric pipe cleaning machine operate unattended. Switch
off the electric pipe cleaning machine during longer work breaks, pull out
the mains plug. Electrical devices can cause hazards which lead to material
damage or injury when left unattended.
●
Children and persons who, due to their physical, sensory or mental abilities
or lack of experience and knowledge are unable to operate the electric pipe
cleaning machine safely may not use this electric pipe cleaning machine
without supervision or instruction by a responsible person.
Otherwise there
is a risk of operating errors and injuries.
●
Keep persons away from your working area.
Do not let other persons, especially
children, touch the power tool or cable. Keep them away from your working area.
●
Keep unused power tools in a safe place.
Power tools should be stored in a
dry, high or locked place out of the reach of children when not in use.
●
Do not use low performance power tools for heavy-duty work.
There is a
risk of injury.
●
Only use approved and appropriately marked extension leads with a suffi -
cient cable cross-section.
Use extension leads up to a length of 10 m with
cable cross-section 1.5 mm
², from 10 – 30 m with cable cross-section 2.5 mm².
REMS Mini-Cobra
●
Remove the crank handle (8) before using the pipe cleaning machine with
an electric drill/screwdriver (8).
There is a risk of injury.
●
Only use suitable electric drills/screwdrivers with electronic speed control
and observe the operating instructions of the electric drill/screwdriver.
There is a risk of injury.
●
Never use/lock the fi xing button of the electric drill's/screwdriver's on/off
switch.
There is a risk of injury.
●
Observe the reaction torque of the drive unit to the spiral drum (10) and
operate the electric pipe cleaning machine only with both hands on the handle
(7) and switch handle (2) the electric drill/screwdriver.
There is a risk of injury.
Fig. 1 – 2
1
Thrust handle
2 Switch handle
3 Direction ring
4 Safety inching switch
5 Chuck
6 Club head
7 Handle
8 Crank
9 Hexagonal driver
10 Spiral drum
11 Th
rust gear
eng eng
7

4
●
Pay attention to the distance from the end of the pipe to the chuck.
The
cleaning spiral can whiplash if the distance is too great (> 200 mm). There is a
risk of injury!
●
Do not use drive units with quick stop.
If the drive unit is shut down immediately,
the vibration torque of the still moving spiral drum (10) can knock over the unit.
Explanation of symbols
WARNING
WARNING
Danger with a medium degree of risk which could result in
death or severe injury (irreversible) if not heeded.
CAUTION
CAUTION
Danger with a low degree of risk which could result in minor
injury (reversible) if not heeded.
NOTICE
NOTICE
Material damage, no safety note! No danger of injury.
Read the operating manual before starting
Power tool complies with protection class II
Environmentally friendly disposal
CE conformity mark
1. Technical Data
Use for the intended purpose
WARNING
WARNING
REMS Mini-Cobra
A
nd REMS Mini-Cobra
A
are intended for clearing pipe blockages,
A are intended for clearing pipe blockages,A
e.g. in the kitchen, bathroom and toilet.
All other uses are not for the intended purpose and are prohibited.
1.1. Scope of Supply
REMS Mini-Cobra: Pipe cleaning machine, p
ipe cleaning spiral Ø 8 mm
,
Instruction Manual.
REMS Mini-Cobra
A
: E
lectric pipe cleaning machine, p
ipe cleaning spiral
with core Ø 8 mm
, Instruction Manual.
1.2. Article numbers
REMS Mini-Cobra pipe cleaning device for manual and electric drive 170010
REMS Mini-Cobra
A
electric pipe cleaning device
A electric pipe cleaning deviceA
170020
Pipe cleaning spiral Ø 8 mm × 7.5 m (REMS Mini-Cobra) 170200
Pipe cleaning spiral with core Ø 8 mm × 7.5 m 170201
Pipe cleaning spiral Ø 10 mm × 10 m 170205
Steel case with inlay 185058
REMS CleanM 140119
1.3. Capacity
REMS Mini-Cobra, REMS Mini-Cobra
A
Clearing pipe blockages
e.g. in the kitchen, bathroom, toilet, for pipes Ø 20 – 50 (75) mm
1.
4
. Electric data
REMS Mini-Cobra
A
230 V, 50 – 60 Hz, 630 W, 2.7 A; protective insulated,
radio interference suppressed, electronically controllable speed 0 – 950 rpm
1.
5
. Dimensions
REMS Mini-Cobra
A
445 ×
A 445 ×A
305
× 200 mm
(
17.5" ×
12.0
" × 7.9"
)
REMS Mini-Cobra 395 × Ø 200 mm
(
15.6
" × Ø 7.9"
)
1.
6
. Weight
REMS Mini-Cobra
A
5.2 kg
A 5.2 kgA
(
11.5 lb
)
REMS Mini-Cobra 2.9 kg
(
6.4 lb
)
1.
7
. Noise information
REMS Mini-Cobra
A
Emission at workplace
L
PA
84 dB(A), L
PA 84 dB(A), LPA
WA
84 dB(A), LWA84 dB(A), L
95 dB(A),
WA 95 dB(A),WA
Uncertainty K = 3 dB
1.
8
. Vibrations
REMS Mini-Cobra
A
Weighted effective value of acceleration 2.5 m/s²
Uncertainty K = 3 dB
The indicated weighted effective value of acceleration has been measured
against standard test procedures and can be used by way of comparison with
another device. The indicated weighted effective value of acceleration can also
be used as a preliminary evaluation of the exposure.
CAUTION
CAUTION
The indicated weighted effective value of acceleration can differ during opera-
tion from the indicated value, dependent on the manner in which the device is
used. Dependent upon the actual conditions of use (periodic duty) it may be
necessary to establish safety precautions for the protection of the operator.
2. Start-up
2.1. Electrical connection
WARNING
WARNING
Caution: Mains voltage present!
Before connecting the power tool, check
whether the voltage given on the rating plate corresponds to the mains voltage.
On building sites, in a wet environment, indoors and outdoors or under similar
installation conditions, only operate the power tool on the mains with a fault
current protection switch (FI switch) which interrupts the power supply as soon
as the leakage current to earth exceeds 30 mA for 200 ms.
2.2. Mounting the pipe cleaning spiral in the spiral drum (10)
When a new pipe cleaning spiral is mounted, this must be bent approx. 45°
about 50 mm before the rear end of the spiral and then pushed through the
open chuck (5) / thrust gear (
11
) into the spiral drum so that the pipe cleaning
spiral winds up in clockwise direction looking though the end opening of the
spiral drum (10). Push in the pipe cleaning spiral until the club head (6) protrudes
approx. 200 mm from the chuck (5) / thrust gear (
11
).
3. Operation
3.1. Operation REMS Mini-Cobra
A
CAUTION
CAUTION
Only operate the electric pipe cleaning machine with both hands, always grip
the thrust handle (1) and switch handle (2) tightly.
Note reaction torque of the
drive unit on the spiral drum (10) when switching on and off! Start the electric
pipe cleaning machine preferably at low speed and increase slowly as required.
Pull out the pipe cleaning spiral Ø 8 mm or Ø 10 mm approx. 150 mm. For pipe
cleaning spiral Ø 8 mm, turn the thrust handle (1) to the stop, for the pipe
cleaning spiral Ø 10 mm until it meets a resistance and then turn it further
approximately one revolution. Set the direction of rotation switch (3) to the arrow
in the direction of the spiral drum (10) to feed the pipe cleaning spiral into the
pipe. The arrow direction corresponds to the feed direction of the pipe cleaning
spiral. With the adjusting wheel on the safety inching switch (4) the speed can
be limited from the lowest stage A to the highest stage F. Press the safety
inching switch (4) lightly so that the spiral drum (10) turns, then increase the
speed slowly as required. If the cleaning spiral meets a resistance, the speed
may have to be reduced or the electric pipe cleaning machine switched off, set
the direction of rotation switch (3) to the arrow in the direction of the switch
handle (2) so that the feed direction can be reversed. After clearing the blockage,
switch off the electric pipe cleaning machine, set the direction of rotation switch
(3) to the arrow in the direction of the swit6ch handle (2) to retract the pipe
cleaning spiral from the pipe. The electric pipe cleaning machine must be
switched off about 200 mm before the club head (6) reaches the thrust gear
(11). After cleaning work, the thrust handle (1) must be released for transport
and the pipe cleaning spiral must be pushed back by hand into the spiral drum
(10) up to just before the stop of the club head (6) on the thrust gear (11).
CAUTION
CAUTION
The pipe cleaning spiral can whiplash if the distance between the end of the
pipe/drain and the thrust gear (
11
) is too great (danger of injury)!
NOTICE
NOTICE
Only push the pipe cleaning spiral into the pipe to an extent that at least two
windings remain in the spiral drum (10) when cleaning. If the pipe cleaning
spiral is pushed further, the motor can no longer retract the spiral. The pipe
cleaning spiral then has to be pushed back into the spiral drum (10) about 2
windings by hand. Then the automatic return starts working again.
The club head (6) formed on the pipe cleaning spiral may never be allowed to
get into the thrust gear (
11
) because otherwise the pipe cleaning spiral will be
damaged.
3.2. Operation REMS Mini-Cobra
Pull the pipe cleaning spiral approx. 300 mm out of the spiral drum (10), tighten
the chuck (5) by hand and insert the spiral into the pipe to be cleaned. Hold
the handle (7) tight and turn the spiral drum (10) clockwise by turning the crank
(8) with your other hand. Only insert the pipe cleaning spiral into the pipe to an
extent that the chuck (5) can still be operated by hand. Open the chuck (5) and
pull the pipe cleaning spiral about 300 mm back out of the spiral drum (10).
Repeat the process until you can feel a resistance or the blockage is cleared.
Pull back the pipe cleaning spiral by hand and push it back into the spiral drum.
3.3. Operation of REMS Mini-Cobra with a suitable electric drill/electric screw-
driver
If an e
lectric drill/electric screwdriver is used to drive the REMS Mini-Cobra,
make sure that this is equipped with a continuous electronic speed control
(0 – 550 rpm). Remove the crank (8). Connect the electric drill/screwdriver with
drill chuck to the hexagonal driver (9).
CAUTION
CAUTION
Do not use an electric drill/screwdriver with quick stop!
If the drive unit is
shut down immediately, the vibration torque of the still moving spiral drum (10)
can knock over the unit.
eng eng
8

5
Pull the pipe cleaning spiral about 300 mm out of the spiral drum (10), tighten
the chuck
(5) by hand. Always start the electric drill screwdriver at low speed
in right right hand rotation and increase the speed as required. Only insert the
pipe cleaning spiral into the p
ipe to an extent that the chuck (5) can still be
operated by hand. Switch off the electric drill/screwdriver. Open the chuck (5)
and pull the pipe cleaning spiral about 300 mm back out of the spiral drum (10).
Repeat the process until you c
an feel a resistance or the blockage is cleared.
Keep a maximum distance of 200 mm between the end of the pipe/drain and
the chuck (5) otherwise the pipe cleaning spiral can loop. Always pull back the
pipe cleaning spiral by hand and push it back into the spiral drum. Only use
anticlockwise rotation of the electric drill/screwdriver if the pipe cleaning spiral
is jammed in the pipe. Switch the electric drill/screwdriver carefully between
clockwise and anticlockwise rotation to remedy this.
4. Maintenance
Notwithstanding the maintenance described below, it is recommended to send
in the electric pipe cleaning machine to an authorised REMS contract customer
service workshop for inspection and periodic testing of electrical devices at
least once a year. In Germany, such periodic testing of electrical devices should
be performed in accordance with DIN VDE 0701-0702 and also prescribed for
mobile electrical equipment according to the accident prevention rules DGUV,
regulation 3 “Electrical Systems and Equipment”. In addition, the respective
national safety provisions, rules and regulations valid for the application site
must be considered and observed.
4.1. Maintenance
WARNING
WARNING
Pull out the mains plug before maintenance work!
Clean the electric pipe cleaning machine and the pipe cleaning spiral regularly
especially when they have not been in use for a long time. Clean plastic parts
(e.g. housing) only with REMS CleanM machine cleaner (Art. No. 140119) or
a mild soap and a damp cloth. Do not use household cleaners. These often
contain chemicals which can damage the plastic parts. Never use petrol,
turpentine, thinner or similar products for cleaning.
Make sure that liquids never get onto or inside the electric pipe cleaning machine.
Never immerse the electric pipe cleaning machine in liquid.
4.2. Inspection/Repair
REMS Mini-Cobra
A
WARNING
WARNING
Pull out the mains plug before maintenance and repair work
!
This work
may only be performed by qualifi ed personnel.
The gear runs in a life-long grease fi lling and therefore needs no lubrication.
The drive machine motor has carbon brushes. These are subject to wear and
must therefore by checked and changed by qualifi ed specialists or an author-
ised REMS
customer service workshop from time to time.
6. Disposal
REMS Mini-Cobra A may not be thrown in the domestic waste after use. It must
be disposed of properly by law.
7. Manufacturer’s Warranty
The warranty period shall be 12 months from delivery of the new product to the
fi rst user. The date of delivery shall be documented by the submission of the
original purchase documents, which must include the date of purchase and the
designation of the product. All functional defects occurring within the warranty
period, which are clearly the consequence of defects in production or materials,
will be remedied free of charge. The remedy of defects shall not extend or
renew the warranty period for the product. Damage attributable to natural wear
and tear, incorrect treatment or misuse, failure to observe the operational
instructions, unsuitable operating materials, excessive demand, use for unau-
thorized purposes, interventions by the customer or a third party or other
reasons, for which REMS is not responsible, shall be excluded from the warranty
Services under the warranty may only be provided by customer service stations
authorized for this purpose by REMS.
Complaints will only be accepted if the
product is returned to a customer service station authorized by REMS without
prior interference and in a fully assembled condition. Replaced products and
parts shall become the property of REMS.
The user shall be responsible for the cost of shipping and returning the product.
A list of the REMS-authorized customer service stations is available on the
Internet under www.rems.de. For countries which are not listed, the product
must be sent to the SERVICE-CENTER, Neue Rommelshauser Strasse 4,
71332 Waiblingen, Deutschland. The legal rights of the user, in particular the
right to make claims against the seller in case of defects as well as claims due
to wilful violation of obligations and claims under the product liability law are
not restricted by this warranty.
This warranty is subject to German law with the exclusion of the confl ict of laws
rules of German International Private Law as well as with the exclusion of the
United Nations Convention on Contracts for the International Sales of Goods
(CISG). Warrantor of this world-wide valid manufacturer’s warranty is REMS
GmbH & Co KG, Stuttgarter Str. 83, 71332 Waiblingen, Deutschland.
8. Spare parts lists
For spare parts lists, see
www.rems.de
→ Downloads → Parts lists.
eng eng
5. Faults
REMS Mini-Cobra
A
5.1.
Fault:
Electric pipe cleaning machine does not start.
Cause:
Remedy:
●
Worn carbon brushes.
●
Have carbon brushes changed by qualifi ed technical personnel or an
authorised REMS customer service workshop.
●
Mains lead defective.
●
Have the connecting cable changed by qualifi ed technical personnel or an
authorised REMS customer service workshop.
●
Electric pipe cleaning machine defective.
●
Have the electric pipe cleaning machine inspected/repaired by an authorised
REMS customer service workshop.
5.2.
Fault:
No feed of the pipe cleaning spiral.
Cause:
Remedy:
●
Thrust handle (1) was not engaged.
●
Engage thrust handle (1), see 3.1. Operation REMS Mini-Cobra A.
●
Pipe cleaning spiral stuck in the pipe or in a pipe blockage.
●
Switch off the electric pipe cleaning machine. Set the direction of rotation
switch (3) to the arrow in the direction of the switch handle (2). Press the safety
inching switch (4) lightly so that the spiral drum (10) turns, then increase the
speed slowly as required.
●
Pipe cleaning spiral is not mounted in the spiral drum (10) in clockwise
direction.
●
Remove pipe cleaning spiral and re-mount, see 2.2.
●
Electric pipe cleaning machine defective.
●
Have the electric pipe cleaning machine inspected/repaired by an authorised
REMS customer service workshop.
9
Table of contents
Other REMS Tools manuals

REMS
REMS Mini-Press 14 V ACC User manual

REMS
REMS Swing User manual

REMS
REMS Nano User manual

REMS
REMS Push User manual

REMS
REMS Tiger User manual

REMS
REMS 4 Quick start guide

REMS
REMS Eskimo User guide

REMS
REMS Amigo User manual

REMS
REMS Magnum 2000 RG-T User manual

REMS
REMS Akku-Press 22 V ACC Connected User manual

REMS
REMS Power-Press E User manual

REMS
REMS Hot Dog 2 User manual

REMS
REMS 153155 User manual

REMS
REMS Ax-Press 25 22 V ACC User manual

REMS
REMS Sinus User manual

REMS
REMS Eco-Press User manual

REMS
REMS Push User manual

REMS
REMS Ax-Press 25 22 V ACC User manual

REMS
REMS Eskimo User manual

REMS
REMS Curvo User manual