INT-SCR-BL SATEL
7
Information on the use of the partition keypad with proximity card reader can be found in the user
manual of the control panels.
The partition keypad with proximity card reader can be programmed by means of the LCD keypad
(¼SERVICE MODE ¼STRUCTURE¼HARDWARE¼EXPANDERS¼SETTINGS¼expander selection)
or a computer with the DLOADXprogram. The operating mode of partition keypad with proximity card
reader offers all the functions available for the partition keypad mode. Support of the proximity cards
should only be additionally taken into account. Presenting the card to the reader is recognized by the
expander as entering the code, confirmed with the key. Holding up the card for approx. 3 sec. is
recognized as entering the code, confirmed with the key.
7. Operation in the Entry Keypad Mode
In the entry keypad, only the LED designated . is used for signaling. Blinking of the LED informs
that the countdown of delay activation time is running (disarming has no effect on the LED blinking).
Information on the use of the entry keypad can be found in the user manual of the control panels.
The entry keypad can be programmed by means of the LCD keypad (¼SERVICE MODE
¼STRUCTURE ¼HARDWARE ¼EXPANDERS ¼SETTINGS ¼expander selection) or a computer with
the DLOADXprogram. Described below are settings and options available for programming.
Name – option to give an individual (16-character) name to the module. This option can be accessed
in the LCD keypad as follows: ¼SERVICE MODE ¼STRUCTURE ¼HARDWARE ¼EXPANDERS ¼
NAMES ¼expander selection.
Partition assignment of the keypad to a partition selected from the list. The delay activation will apply
to the zones with reaction type 3. INTERIOR DELAYED in this partition.
Master users / Users – this function defines master users / users authorized to use the given
keypad.
Alarm 3 incorrect codes – entering codes / reading cards unknown to the control panel three times
triggers alarm
Control BI output – the keypad accepts the BI OUTPUTS type of codes.
Control MONO output – the keypad accepts the MONO OUTPUTS type of codes.
Guard round control – entering the guard code ended with or key as well as presenting or
holding up the card will be recorded as completion of the round.
Signaling
Delay activation sign. – when the option is enabled, the keypad will signal with beeps the
countdown of delay unblocking time.
Access code signaling (hardware) – enabling this option will activate the signaling of code entry /
card reading acknowledgement, which is independent of the control panel. The option is useful
in expanded alarm systems, because of a considerable time lag between entering the
code / reading the card and generating the audible signal by the control panel.
Confirming – this option defines the way of communication between the control panel and the
keypad user:
No – the function of keypad operation acknowledgement is disabled.
Sound – the keypad generates beeps as described in the user manual for the alarm control panel.
Backlight – the audible signaling will be replaced by the blinking keypad illumination as described
in the user manual for the alarm control panel.
Backlight – defines the mode of keypad illumination
No – keypad backlighting disabled.
Auto – keypad backlighting goes on automatically on pressing any key.
Note: Automatic keypad illumination is ON for approx. 40 seconds from the moment of its
activation or from the last press of any key.
Permanent – keypad backlighting is permanently "ON".