SET DESCRIPTION DEFAULT NOTES
If the photocell is occupied during closing, the gate
reverses the movement; If the photocell is occupied
during the pause, it prevents the gate reclosing
If the photocell is occupied during opening or closing, it
stops the gate movement; when the photocell is released,
the movement continues
If the photocell is occupied before the Start input, the
Start will be ignored. If the photocell is occupied after the
Start input, the photocell will be ignored. If the photocell
is occupied during closing, the gate will reopen
If the photocell is occupied during closing, it stops the gate
movement; when released, the closing movement
continues
The photocell stops the gate until it is occupied in both
opening and closing; when released, it send a closing input
(the gate closes 1s after the photocell release)
If the photocell is occupied during opening or closing, it
stops the gate movement; when released, the movement
continues. If the photocell is occupied during the pause, it
reloads the pause time set
Pause reload
Photo closing
If the photocell is occupied during the pause, it reloads the
pause time set. If the photocell is occupied during closing,
the gate reverses the movement
When the gate is open, the shadow loop prevents the
reclosing until it is occupied. The Shadow loop is switched
off during closing
If the photocell is occupied during opening, pause or
closing, the gate reopens completely and closes without
observing the pause time set
Shadow loop RP
(pause reloading)
When the gate is open, the shadow loop prevents the
reclosing until it is occupied. When released, the gate
repeats the pause time set, then it closes. The Shadow
loop is switched off during closing
If the photocell is occupied during opening, the gate will
stop; when released, the gate continues the opening
movement. The photocell is ignored during closing
Stop N.O. Stop connection on ERG push-button panel
To enable the second safety edge
With models "R2BF" and "R2EF" only the connection of a
Standard Safety Edge (Normal) is allowed
With model "R3BF" the connection of different Safety
Edge types is allowed; Select the type on menu 101;
With all models it is possible to choose the working
direction of the second safety edge by the menu 103