SET DESCRIPTION MODEL DEFAULT NOTE
If the photocell is occupied during closing, the gate
reverses the movement; If the photocell is occupied
during the pause, it prevents the gate reclosing
If the photocell is occupied during opening or closing, it
stops the gate movement; when the photocell is
released, the movement continues
If the photocell is occupied before the Start input, the
Start will be ignored. If the photocell is occupied after
the Start input, the photocell will be ignored. If the
photocell is occupied during closing, the gate reopens
If the photocell is occupied during closing, it stops the
gate; when released, the closing movement continues
The photocell stops the gate until it is occupied in both
opening and closing; when released, the photocell gives
a closing command (the gate closes one second after
the photocell release)
If the photocell is occupied during the pause, it
recharges the same pause time set. If the photocell is
occupied during the opening, the gate stops and when
released, the movement continues
Pause reload
Photo closing
If the photocell is occupied during the pause, it reloads
the pause time set. If the photocell is occupied during
closing, the gate reverses the movement
Opening and Closing
Pause reloading
If the photocell is occupied during the pause, it reloads
the pause time set. If the photocell is occupied during
the closing, it reverses the movement; If the photocell is
occupied during the opening, it stops the gate and when
released, the opening continues
When the gate is open, the shadow loop prevents the
reclosing until it is occupied. The Shadow loop is
switched off during closing
If the photocell is occupied during opening, pause or
closing, the gate reopens completely and closes without
observing the pause time set
Shadow loop PR
(pause reloading)
When the gate is open, the shadow loop prevents the
reclosing until it is occupied. When released, the gate
repeats the pause time set, then it closes. The Shadow
loop is switched off during closing
If the photocell is occupied during opening, the gate
stops; when released, the gate continues the opening
movement. The photocell is ignored during closing
In closing, this function excludes the photocell reading
for the space percentage set
Normal Standard safety edge - N.C. contact
8K2 N.C. Safety edge protected by a 8K2 resistor enabled
8K2 N.C. Double Two safety edges protected by 8K2 resistor enabled
8K2 RES Resistive edge protected by 8K2 resistor enabled
8K2 RES Double Two resistive edges protected by 8K2 RES enabled
Normal Standard safety edge - N.C. contact
8K2 N.C. Safety edge protected by a 8K2 resistor enabled
8K2 N.C. Double Two safety edges protected by 8K2 resistor enabled
8K2 RES Resistive edge protected by 8K2 resistor enabled
8K2 RES Double Two resistive edges protected by 8K2 RES enabled