4 - CONNECTIONS ON CN1
Common
Common
Photocell 1
Common
Photocell 2
Partial Opening START
taliano
EGIS
International registered trademark n. 804888
TX1
TX2
24V
1
1
12
11
1
1
4
2
1
Start
Stop
Antenna
RX1
RX2
4.1 SAR ..
n clamps 2 and
The automation can be opened or closed through an impulse
transmitted to this input (via e button, eboard, etc.). To
connect other Start devices (for ex. the magnetic loop) refer to
the respective instructions
ote 1: In DEAD MAN logic it is necessar to hold the Start
button pressed to open the automation
ote 2: In 2 BUTTONS logic the connected Start device onl
performs the opening
4.2 ARIA EIG SAR ..
n clamps 2 and 4
The input allows to obtain the partial opening. It is possible to
manage the opening space through the men or through
the OLLY 3. It is also possible to manage the partial opening
pause time through the men 1
ote 1: In 2 BUTTONS logic, the connected Partial Opening
Start device onl performs the closing
ote 2: In DEAD MAN logic, it is necessar to hold the Partial
Opening Start button pressed to close the gate
ote : If this contact is engaged during the pause (eg. Timer),
the gate will not close until releasing
ote 4 PARTIAL OPENIN START contat is normall open (N.O.)
4. S .. n clamps and
If this button is pressed the engine stops immediatel in whatever condition or position it is. A new Start
command will be required to restore the movement.
ote After the Stop command, the engine will always re-start in closing
4.4 E 1 AD E 2
ma 75m clamp CM clamp CM clamp
otocell clamp otocell clamp
ote 1: To perform the self-test, connect the T positive to the clamp 10 (AU) and activate the Phototest
function on men4 From the ES menu it is possible to activate the self-test also on a
single photocell, choosing from the menu options.
ote 2: The default settings are: E 1 closing E 2 opening
for further functions and management, see menu-97 and menu-98
4. AUX 24V IS ma mA
From men 424VAUX or through the OLLY 3 it is possible to choose when to have voltage on the AU
output. In case of control units with batteries and/or photovoltaic panels, it is advisable to connect the
unused accessories (eg. Photocells) to the AU output and then configure the men 424VAUX as
CC D TTT so it will be possible to save energ b lowering the power consumption in stand-
b and increasing the sstem autonom
4. IMER ..
n clamp 4 artial penin Start or on clamp hotocell 2
It can be enabled through men2 or via OLLY 3. It opens and eeps the automation open until it
releases the contact. hen released, the operator will wait for the pause set then will close again
ote 1: If connected to the Partial Opening Start, this command will also be disabled on the remote control
ote 2: hen the timer is active, in the event of a safet intervention, a Start command will be required to
reset the movement
ote : In case of a power failure and with the gate open, if the TIMER is still active it will cause the gate
reclosing if no longer active, a new Start impulse will be required