Whenthe alarmoccurs,correspondingalarmindicatorofcontrolpanellights,LED
digitaldisplayarea showsthe fault code.
Whenthe factory, the maximumtemperatureprotectionvalue issetto230℃, the
valuecorrespondstotheparameterF-18.
Whenthe alarmoccurs, you can confirmthat the firstlayerof over-temperature
protection(EGO)disabled, the fault can beresolvedinaccordancewiththe E-04
alarmelimination methods.
4.4.6Actualtemperatureishigherthan the sumofset temperatureand alarm
temperature Over-temperature alarmE-07
Whenthe alarmoccurs,correspondingalarmindicatorofcontrolpanellights,LED
digitaldisplayarea showsthe fault code.
Whenthe factory, the temperatureprotection valueisset to15℃, thevalue
correspondstothe parameterF-05.
The significanceof the protection isreal-timetemperatureprotection, the
protectiontemperatureisarelativevalue (relativetoset temperature), for
example,the currentsettemperatureis100℃, protection temperatureis15℃,the
alarmoccurswhen the actualtemperatureishigherthan 135℃.
Accordingtothe following stepstoeliminatefault:
Check whetherthe contactorisworkingproperly.Innon-energized case, check
the electromagneticcontactormoving contactpartsarenormalaction,if actionis
not available,itisrecognized contactordamage,if you canoperatenormally, you
need toenergizethe machine,when the actualtemperaturereachesthesetpoint,
observewhethercontactormovablecontactisseparatefromstationarycontact, if
separatedthe contactorisworkingproperly,ifthereisnoseparation, can be
confirmed contactorisworkingproperlybymeasuring contactorcontactvoltage,if
electromagneticcontactorcontactisstillmeasured thesamevoltage and control
voltage when actualtemperaturereachesthesetpoint, youcan confirmthe
microcomputerfault, if not, youcan confirmthe mechanicalpart of contactorfault.
Check whetherblowerisworking properly. Asactualtemperatureismeasured by
measuring airtemperature, thermocouplewillmeasureastablelowtemperature
valueif the blowerisnot running,lead totemperaturecontrollerhasan output
signaltoheating pipetoheat allthetime, resulting inover-temperaturealarm.
Confirmmicrocomputerpanelinternalparametersarecorrect. Microcomputer
panelinternalsavethe PIDparametersforcontrolling temperatureheatmethod,if
the parametersarenot correct, willcauseheatingsystemheat abnormally. To