MOUNTING
8. Place reed at desired location
(top, right, bottom or left)
9. Position base. Mark and drill four (4) holes 1”
(25mm) deep. Using plastic anchor, drill 3/16”
(4.5mm). Install into wood or steel: drill 9/64”
(3.5mm). Mount using (4) M4 x 25mm screws.
10. Install reed magnet, mark with pencil,
drill, install using plastic anchor, drill 3/16”
(4.5mm). Install into wood or steel: drill 1/8”
(3mm). Mount with (2) M3.5 x 32mm screws.
11. Test, turn key on, open door
12. Replace cover, snap lid from top,
secure with security screw
6400 QUICK INSTALL
OCT2018
Subject to change
without notice.
2306 Airport Rd • Waterford, MI 48327, USA
Phone: 248-673-9898 • Fax: 248-673-1246
Taylor House • 34 Sherwood Road • Bromsgrove, Worcestershire • B60 3DR • England
T
el: +44 (0)1527 520 999 • Fax: +44 (0)1527 501 999 •
[email protected] • www
.sti-emea.com
MOUNTING HOLESMOUNTING HOLES
Mounting Holes Mounting Holes
Warranty
WARNING: This product can expose you to chemicals including Bisphenol A, which is known to the State of California to cause
reproductive harm and Dichloromethane, which is known to the State of California to cause cancer. For more information go to
www.P65Warnings.ca.gov.
Three year warranty or a one year limited warranty (from date of purchase) on most products. See website for details.
Electronic warranty form at www.sti-usa.com/wc14.
SWITCH SETTINGS 1 2 3 4 5 6 7 8
Arming - immediate OFF*
Arming - 15 second delay ON
Trip - immediate OFF*
Trip - 15 second delay ON
Shut-off based on duration
Shut-off approx. 3 sec. after
Duration - 30 second alarm OFF* OFF*
Duration - 180 second alarm OFF ON
Duration - continuous alarm ON OFF
Duration - annunciator mode ON ON
Low battery detection on - Turn switch off OFF*
Low battery detection off - Turn switch on ON
Volume - high ON*
Volume - low OFF
Relay function OFF OFF*
Relay function ON ON
OFF*
ON
door closes
(switches 4 & 5)
*default