manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. STI
  6. •
  7. Security System
  8. •
  9. STI Stopper SS2 0 Series User manual

STI Stopper SS2 0 Series User manual

This manual suits for next models

3

Other STI Security System manuals

STI STI-SA5600 User manual

STI

STI STI-SA5600 User manual

STI STI-SA5500 User manual

STI

STI STI-SA5500 User manual

STI Alert Point Troubleshooting guide

STI

STI Alert Point Troubleshooting guide

STI STI-SA5500 User manual

STI

STI STI-SA5500 User manual

STI Exit Stopper STI-6400 Series Instructions for use

STI

STI Exit Stopper STI-6400 Series Instructions for use

STI Theft Stopper STI-6200 Series Instruction sheet

STI

STI Theft Stopper STI-6200 Series Instruction sheet

STI Rex Plus II User manual

STI

STI Rex Plus II User manual

STI Stopper Station Series User manual

STI

STI Stopper Station Series User manual

STI STI-34501 User manual

STI

STI STI-34501 User manual

STI 6400 User manual

STI

STI 6400 User manual

STI SELECT-ALERT SA5000 Series User manual

STI

STI SELECT-ALERT SA5000 Series User manual

STI Exit Stopper STI-6400 Series User manual

STI

STI Exit Stopper STI-6400 Series User manual

STI STI-WS109 User manual

STI

STI STI-WS109 User manual

STI STI-6400 User manual

STI

STI STI-6400 User manual

STI Exit Stopper STI-6404 Instructions for use

STI

STI Exit Stopper STI-6404 Instructions for use

STI Mugger Stopper Plus User manual

STI

STI Mugger Stopper Plus User manual

STI Fire Stopper Series User manual

STI

STI Fire Stopper Series User manual

STI SA5500 User manual

STI

STI SA5500 User manual

STI SS2 6 Series User manual

STI

STI SS2 6 Series User manual

STI Home & Work Series User manual

STI

STI Home & Work Series User manual

STI UB-2PN User manual

STI

STI UB-2PN User manual

Popular Security System manuals by other brands

Inner Range Concept 2000 user manual

Inner Range

Inner Range Concept 2000 user manual

Climax Mobile Lite R32 Installer's guide

Climax

Climax Mobile Lite R32 Installer's guide

FBII XL-31 Series installation instructions

FBII

FBII XL-31 Series installation instructions

Johnson Controls PENN Connected PC10 Install and Commissioning Guide

Johnson Controls

Johnson Controls PENN Connected PC10 Install and Commissioning Guide

Aeotec Siren Gen5 quick start guide

Aeotec

Aeotec Siren Gen5 quick start guide

IDEAL Accenta Engineering information

IDEAL

IDEAL Accenta Engineering information

Swann SW-P-MC2 Specifications

Swann

Swann SW-P-MC2 Specifications

Ecolink Siren+Chime user manual

Ecolink

Ecolink Siren+Chime user manual

Digital Monitoring Products XR150 user guide

Digital Monitoring Products

Digital Monitoring Products XR150 user guide

EDM Solution 6+6 Wireless-AE installation manual

EDM

EDM Solution 6+6 Wireless-AE installation manual

Siren LED GSM operating manual

Siren

Siren LED GSM operating manual

Detection Systems 7090i Installation and programming manual

Detection Systems

Detection Systems 7090i Installation and programming manual

Se-Kure Controls MicroMini SK-4841 instructions

Se-Kure Controls

Se-Kure Controls MicroMini SK-4841 instructions

Siemens FDM273 manual

Siemens

Siemens FDM273 manual

DSC PC 4010 Programming manual

DSC

DSC PC 4010 Programming manual

UniPOS 6202L quick start guide

UniPOS

UniPOS 6202L quick start guide

AJAX DoubleButton user manual

AJAX

AJAX DoubleButton user manual

Rondish Nexus User instructions

Rondish

Rondish Nexus User instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

E-mail: [email protected] • Web: www.sti-usa.com
USA - Headquarters
2306 Airport Road • Waterford, Michigan 48327-1209
Phone: 248-673-9898 • Fax: 248-673-1246
Tel: 44 (0) 1527 520 999 Fax: 44 (0) 1527 501 999
E-mail: [email protected] • Web: www.sti-emea.com
European Office
Taylor House • 34 Sherwood Road • Bromsgrove
Worcestershire • B60 3DR • England
INSTALLATION OF SS-2000 SERIES STOPPER®STATION
1027IS JAN2017
All specifications and information shown were current as of publication, and are subject to change without notice
INSTALLATION OF SS2xx0, 2xx1, 2xx3 and 2xx4 SERIES STOPPER®STATION
All specifications and information shown were current as of publication, and are subject to change without notice
INSTALLATION OF SS-2000 SERIES STOPPER®STATION
1027IS JAN2017
All specifications and information shown were current as of publication, and are subject to change without notice
INSTALLATION OF SS2xx0, 2xx1, 2xx3 and 2xx4 SERIES STOPPER®STATION
ID_SS2_00_01_03_04_Rev0320
All specifications and information shown were current as of publication, and are subject to change without notice
INSTALLATION OF SS-2000 SERIES STOPPER®STATION
1027IS JAN2017
All specifications and information shown were current as of publication, and are subject to change without notice
INSTALLATION OF SS2xx0, 2xx1, 2xx3 and 2xx4 SERIES STOPPER®STATION
All specifications and information shown were current as of publication, and are subject to change without notice
INSTALLATION OF SS-2000 SERIES STOPPER®STATION
1027IS JAN2017
All specifications and information shown were current as of publication, and are subject to change without notice
INSTALLATION OF SS2xx0, 2xx1, 2xx3 and 2xx4 SERIES STOPPER®STATION
All specifications and information shown were current as of publication, and are subject to change without notice
NOTE: MODELS REQUIRE KIT-71101B-*COLOUR*
MODELS ONLY SUITABLE FOR EXTENDED DEPTH SURFACE
MOUNTING DUE TO DIMENSIONS OF CONTACTS
82mm
(3.25 in.)
124mm
(4.87 in.)
41mm
(1.62 in.) 57mm
(2.25 in.)
PRODUCT DIMENSIONS
SPACER DEPTH
12mm (0.47in.)
x2 24mm (0.94in.)
41mm
(1.62 in.) BACK BOX
DEPTH
40mm
(1.57 in.)
KIT-71101B-*COLOUR*
+ KIT-102720-* DEPTH
64mm
(2.52 in.)
*SS-2**4 and LT1 NOTES: For access control installations, power for the LT-1UL Timer must be supplied by a power
source listed to UL294. When used for access control, this device shall be used as part of an access controlled egress
door system. It is up to the local AHJ to allow use of this device in place of an automatic sensor. For higher security
installations, lower time limits should be used. For SS-2** and LT1-UL the enclosed timer is to be used and installed
per the enclosed LT-1UL installation sheet. SS-2**4 and LT1-UL maximum rating 30 VDC 3A.
WARNING: This product can expose you to chemicals including Dichloromethane,
which is known to the State of California to cause cancer, and Bisphenol A (BPA)
which is known to the State of California to cause birth defects or other
reproductive harm. For more information go to www.P65Warnings.ca.gov.
HOUSING INDEXING SLOTS
BACKPLATE ASSEMBLY
(SEE REVERSE SIDE)
KIT-71101B-*COLOUR*
(40MM BACKBOX,
& 12MM WORLDWIDE
MOUNTING
PLATE/SPACER)
M10274-W
OCTAGON SHELL
E10105 MOMENTARY BUTTON (#4)* KIT-H18062 KEYS
(2) PROVIDED
M10271 STATION
HOUSING
E10100 PUSH/TURN
RESET BUTTON (#1)
KEY BUTTON (#3)
KEY REQUIRED TO ACTIVATE - IN
ACTIVATE MODE KEY CAN BE REMOVED
#8-32 x 3/8 in. BUTTON HEAD
SCREW (1) PROVIDED
KEYS
(2) PROVIDED
E10102 KEY RESET SWITCH
OCTAGON KEY
RESET BUTTON (#0)
M02050
PUSH
PUSH
HERE
MESSAGE
AREA
KIT-102720-*COLOUR*
SUPPLIED 12MM
WORLDWIDE MOUNTING
PLATE/SPACER
USE FOR EUROPEAN SINGLE GANG INSTALLATION
M3.5 x 35MM SWITCH PINS (x2 SUPPLIED)
INSTALLATION OF SS-2000 SERIES STOPPER®STATION
1027IS JAN2017
All specifications and information shown were current as of publication, and are subject to change without notice
INSTALLATION OF SS2xx0, 2xx1, 2xx3 and 2xx4 SERIES STOPPER®STATION
All specifications and information shown were current as of publication, and are subject to change without notice
INSTALLATION OF SS-2000 SERIES STOPPER®STATION
1027IS JAN2017
All specifications and information shown were current as of publication, and are subject to change without notice
INSTALLATION OF SS2xx0, 2xx1, 2xx3 and 2xx4 SERIES STOPPER®STATION
All specifications and information shown were current as of publication, and are subject to change without notice
ID_SS2_00_01_03_04_Rev0320
STRIP 1/4 in. OF WIRE INSULATION
INSERT IN TERMINAL (AS SHOWN) THEN
USING A PHILLIPS SCREWDRIVER TURN
CLOCKWISE UNTIL TIGHT.
NC
NO
1
2
3
4
SEPARATION OF TERMINAL ASSEMBLY.
FROM BUTTON ASSEMBLY IS AS FOLLOWS:
GRASP TERMINAL HOUSING AND USING THUMB
APPLY PRESSURE DOWNWARD, REMOVE TERMINAL.
REMOVAL OF TERMINAL BLOCK
FROM TERMINAL HOUSING: INSERT
SMALL SCREWDRIVER (AS SHOWN)
AND PRY UPWARD, REMOVE TERMINAL.
TERMINAL BLOCK
RELEASE LEVER
MUST FACE UPWARD
AS SHOWN FOR SWITCH
TO FUNCTION CORRECTLY.
ELECTRICAL TERMINAL BLOCK
UP TO 3 TERMINALS MAY BE USED
INSERT NOTCH, AS SHOWN
THEN ROTATE UPWARD
TERMINAL BLOCK KIT-E10196 NO (1) PROVIDED
KIT-E10198 NC (1) PROVIDED
SEE VIEW IN DIRECTION OF ARROW
FOR CONTACT INDENTIFIER LOCATIONS
UP TO (3) TERMINALS MAY BE USED FOR EACH
STATION ASSEMBLY.
OUTGOING
INCOMING
USE SCREWS #6-32 x 1 (x2 PROVIDED) WHEN
FLUSH MOUNTING TO USA-TYPE OUTLET BOX.
USE SELF TAPPING SCREWS #4 x 1¼ (x2 PROVIDED)
WHEN USING KIT-102720-*COLOUR*
SPACER/BACKBOX (SEE REVERSE SIDE).
#10-32 x 3/8 in. GROUND
SCREW (1) PROVIDED
BUTTON LOCK NUT
BACKPLATE
A
VOLTAGERATED AVERAGE CURRENT
250 VDC 1 AMP
600 VAC 3 AMP
ALL TERMINALS ACCEPT TWO 12 TO 18 (AWG)
NOTE: SS2xx4/LT CONTACTS ON FORM C TIMER RATED: 120 VAC, 3A
28 VDC, 3A
E-mail: [email protected] • Web: www.sti-usa.com
USA - Headquarters
2306 Airport Road • Waterford, Michigan 48327-1209
Phone: 248-673-9898 • Fax: 248-673-1246
Tel: 44 (0) 1527 520 999 Fax: 44 (0) 1527 501 999
E-mail: [email protected] • Web: www.sti-emea.com
European Office
Taylor House • 34 Sherwood Road • Bromsgrove
Worcestershire • B60 3DR • England