manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. STI
  6. •
  7. Security System
  8. •
  9. STI STI-SA5500 User manual

STI STI-SA5500 User manual

This manual suits for next models

3

Other STI Security System manuals

STI SA5500 User manual

STI

STI SA5500 User manual

STI Home & Work Series User manual

STI

STI Home & Work Series User manual

STI SELECT-ALERT SA5000 Series User manual

STI

STI SELECT-ALERT SA5000 Series User manual

STI 6400 User manual

STI

STI 6400 User manual

STI STI-SA5600 User manual

STI

STI STI-SA5600 User manual

STI Exit Stopper STI-6400 Series User manual

STI

STI Exit Stopper STI-6400 Series User manual

STI STI-WS109 User manual

STI

STI STI-WS109 User manual

STI Alert Point Troubleshooting guide

STI

STI Alert Point Troubleshooting guide

STI Fire Stopper Series User manual

STI

STI Fire Stopper Series User manual

STI Exit Stopper STI-6400 Series Instructions for use

STI

STI Exit Stopper STI-6400 Series Instructions for use

STI SS2 6 Series User manual

STI

STI SS2 6 Series User manual

STI STI-SA5500 User manual

STI

STI STI-SA5500 User manual

STI STI-34501 User manual

STI

STI STI-34501 User manual

STI Stopper Station Series User manual

STI

STI Stopper Station Series User manual

STI Stopper SS2 0 Series User manual

STI

STI Stopper SS2 0 Series User manual

STI Theft Stopper STI-6200 Series Instruction sheet

STI

STI Theft Stopper STI-6200 Series Instruction sheet

STI Rex Plus II User manual

STI

STI Rex Plus II User manual

STI Exit Stopper STI-6404 Instructions for use

STI

STI Exit Stopper STI-6404 Instructions for use

STI UB-2PN User manual

STI

STI UB-2PN User manual

STI STI-6400 User manual

STI

STI STI-6400 User manual

STI Mugger Stopper Plus User manual

STI

STI Mugger Stopper Plus User manual

Popular Security System manuals by other brands

Inner Range Concept 2000 user manual

Inner Range

Inner Range Concept 2000 user manual

Climax Mobile Lite R32 Installer's guide

Climax

Climax Mobile Lite R32 Installer's guide

FBII XL-31 Series installation instructions

FBII

FBII XL-31 Series installation instructions

Johnson Controls PENN Connected PC10 Install and Commissioning Guide

Johnson Controls

Johnson Controls PENN Connected PC10 Install and Commissioning Guide

Aeotec Siren Gen5 quick start guide

Aeotec

Aeotec Siren Gen5 quick start guide

IDEAL Accenta Engineering information

IDEAL

IDEAL Accenta Engineering information

Swann SW-P-MC2 Specifications

Swann

Swann SW-P-MC2 Specifications

Ecolink Siren+Chime user manual

Ecolink

Ecolink Siren+Chime user manual

Digital Monitoring Products XR150 user guide

Digital Monitoring Products

Digital Monitoring Products XR150 user guide

EDM Solution 6+6 Wireless-AE installation manual

EDM

EDM Solution 6+6 Wireless-AE installation manual

Siren LED GSM operating manual

Siren

Siren LED GSM operating manual

Detection Systems 7090i Installation and programming manual

Detection Systems

Detection Systems 7090i Installation and programming manual

Se-Kure Controls MicroMini SK-4841 instructions

Se-Kure Controls

Se-Kure Controls MicroMini SK-4841 instructions

Siemens FDM273 manual

Siemens

Siemens FDM273 manual

DSC PC 4010 Programming manual

DSC

DSC PC 4010 Programming manual

UniPOS 6202L quick start guide

UniPOS

UniPOS 6202L quick start guide

AJAX DoubleButton user manual

AJAX

AJAX DoubleButton user manual

Rondish Nexus User instructions

Rondish

Rondish Nexus User instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

INSTALLATION OF STI-SA5500 SELECT ALERT SIREN/STROBE
All specifications and information shown were current as of publication and are subject to change without notice.
SA5500IS DEC2020
BATTERY INSTALLATION/REPLACEMENT
1. Unscrew lens to remove.
2. Loosen PCB screws (do not remove).
3. Gently rotate PCB without touching LED’s and
without damaging the reflectors.
4. Connect battery and slide under retainer.
5. Re-install PCB and tighten screws.
NOTES
1. Internal battery will provide backup power if loss of external power.
2. If no internal battery is used, remove all power and move S2-1 to
“OFF” position (see detail S2).
LOW BATTERY OPERATON
Replace battery when low battery condition occurs,
Low battery LED flashes 1x per 1 minute and sounder
beeps 1x per 3 minutes
WARNING: This product can expose you to chemicals including Dichloromethane, which is
known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the
State of California to cause birth defects or other reproductive harm. For more information go to
www.P65Warnings.ca.gov.
Three year warranty or a one year limited warranty (from date of purchase) on most products.
PCB SCREWS
9 VDC BATTERY (NOT INCLUDED)
9 VDC BATTERY CONNECTOR
CIRCUIT BOARD
LENS
LENS
#6 x 2 1/2 in. SCREW
(2) PROVIDED
O-RING (2) PROVIDED
ELECTRONIC BASE
DRILL 3/16 DIA. HOLES
1 1/4 in. DEEP WHEN USING ANCHORS
DRILL 7/64 DIA. HOLES 1 1/4 in. DEEP
WHEN ANCHORS ARE NOT USED
#8-10 WALL ANCHOR (2) PROVIDED
S1 S2
REFLECTORS
LOW BATTERY
LED
FLASH RATE ADJUSTMENT
2020_V1.6
ON
OFF
SIRENVOL
1 2 3 4 5 6
1 2 3 4 5 6
ON DIP
ON
OFF
STROBE
LOW
BAT
12 3 4
1 2 3 4
ON DIP
ON
OFF
LOW
BAT
1
S1
STROBE
2 3 4
SLOW
FAST
VR1
5501
2020_v1.6
ON
OFF
S2
4 5 61 23
VOL SIREN
LOW BATTERY LED
DETAILS S1 DETAILS S2
S2
S1
FLASH RATE
ADJUSTMENT
FAST
SLOW
Don’tTouch LED
Don’tTouch LED
1Siren Volume
23456
ON
OFF
1
Strobe
LOW
BAT
23
ON
OFF
4
5500
V1.3_x1
Slow
Fast
PCB SCREWS
9 VDC BATTERY (NOT INCLUDED)
9 VDC BATTERY CONNECTOR
CIRCUIT BOARD
LENS
LENS
#6 x 2 1/2 in. SCREW
(2) PROVIDED
O-RING (2) PROVIDED
ELECTRONIC BASE
DRILL 3/16 DIA. HOLES
1 1/4 in. DEEP WHEN USING ANCHORS
DRILL 7/64 DIA. HOLES 1 1/4 in. DEEP
WHEN ANCHORS ARE NOT USED
#8-10 WALL ANCHOR (2) PROVIDED
S1 S2
REFLECTORS
LOW BATTERY
LED
FLASH RATE ADJUSTMENT
2020_V1.6
ON
OFF
SIRENVOL
1 2 3 4 5 6
1 2 3 4 5 6
ON DIP
ON
OFF
STROBE
LOW
BAT
12 3 4
1 2 3 4
ON DIP
ON
OFF
LOW
BAT
1
S1
STROBE
2 3 4
SLOW
FAST
VR1
5501
2020_v1.6
ON
OFF
S2
4 5 61 2 3
VOL SIREN
LOW BATTERY LED
DETAILS S1 DETAILS S2
S2
S1
FLASH RATE
ADJUSTMENT
FAST
SLOW
Don’tTouch LED
Don’tTouch LED
1Siren Volume
23456
ON
OFF
1
Strobe
LOW
BAT
23
ON
OFF
4
5500
V1.3_x1
Slow
Fast
DETAIL S1
See pg. 2
DETAIL S2
3.73 in.
(94.6 mm)
.94 in.
(23.8 mm)
2.83 in.
(71.8 mm)
1.02 in.
(26.0 mm)
3.87 in.
( 98.2 mm)
3.73 in.
(94.6 mm)
.94 in.
(23.8 mm)
2.83 in.
(71.8 mm)
1.02 in.
(26.0 mm)
3.87 in.
( 98.2 mm)
1 2 3 4 FUNCTION
1 LOW BATTERY NOTIFICATION ON
* 0 LOW BATTERY NOTIFICATION OFF
* 0 0 0 CONTINUOUS “ON”
0 0 1 DOUBLE LED ROTATION
0 1 0 3 FLASH - DELAY - 3 FLASH
0 1 1 SINGLE LED ROTATION (FAST)
1 0 0 FLASHING
1 0 1 INTENSITY RAMPING UP & DOWN
1 1 0 SINGLE LED ROTATION (SLOW)
1 1 1 RIGHT/LEFT ROTATION
S2 - LOW BAT. NOTIFICATION/STROBE CONTROL
1 2 3 4
1 ON
0 OFF
*Default Settings
SPECIFICATION
Input Standby Operating
9VDC < 14µA 0.95A
12VDC < 180µA 0.96A
24VDC < 170µA 0.49A
Operating Temperature
-4°F to 140°F (-20°C to 60°C)
PCB SCREWS
9 VDC BATTERY (NOT INCLUDED)
9 VDC BATTERY CONNECTOR
CIRCUIT BOARD
LENS
LENS
#6 x 2 1/2 in. SCREW
(2) PROVIDED
O-RING (2) PROVIDED
ELECTRONIC BASE
DRILL 3/16 DIA. HOLES
1 1/4 in. DEEP WHEN USING ANCHORS
DRILL 7/64 DIA. HOLES 1 1/4 in. DEEP
WHEN ANCHORS ARE NOT USED
#8-10 WALL ANCHOR (2) PROVIDED
S1 S2
REFLECTORS
LOW BATTERY
LED
FLASH RATE ADJUSTMENT
2020_V1.6
ON
OFF
SIRENVOL
1 2 3 4 5 6
1 2 3 4 5 6
ON DIP
ON
OFF
STROBE
LOW
BAT
12 3 4
1 2 3 4
ON DIP
ON
OFF
LOW
BAT
1
S1
STROBE
2 3 4
SLOW
FAST
VR1
5501
2020_v1.6
ON
OFF
S2
4 5 61 2 3
VOL SIREN
LOW BATTERY LED
DETAILS S1 DETAILS S2
S2
S1
FLASH RATE
ADJUSTMENT
FAST
SLOW
Don’t Touch LED
Don’t Touch LED
1Siren Volume
23456
ON
OFF
1
Strobe
LOW
BAT
23
ON
OFF
4
5500
V1.3_x1
Slow
Fast
PCB SCREWS
9 VDC BATTERY (NOT INCLUDED)
9 VDC BATTERY CONNECTOR
CIRCUIT BOARD
LENS
LENS
#6 x 2 1/2 in. SCREW
(2) PROVIDED
O-RING (2) PROVIDED
ELECTRONIC BASE
DRILL 3/16 DIA. HOLES
1 1/4 in. DEEP WHEN USING ANCHORS
DRILL 7/64 DIA. HOLES 1 1/4 in. DEEP
WHEN ANCHORS ARE NOT USED
#8-10 WALL ANCHOR (2) PROVIDED
S1 S2
REFLECTORS
LOW BATTERY
LED
FLASH RATE ADJUSTMENT
2020_V1.6
ON
OFF
SIRENVOL
1 2 3 4 5 6
1 2 3 4 5 6
ON DIP
ON
OFF
STROBE
LOW
BAT
12 3 4
1 2 3 4
ON DIP
ON
OFF
LOW
BAT
1
S1
STROBE
2 3 4
SLOW
FAST
VR1
5501
2020_v1.6
ON
OFF
S2
4 5 61 2 3
VOL SIREN
LOW BATTERY LED
DETAILS S1 DETAILS S2
S2
S1
FLASH RATE
ADJUSTMENT
FAST
SLOW
Don’t Touch LED
Don’t Touch LED
1Siren Volume
23456
ON
OFF
1
Strobe
LOW
BAT
23
ON
OFF
4
5500
V1.3_x1
Slow
Fast
BLK (-)
RED (+)
9VDC
+
-
STROBE & SIREN
TRIGGER
(NOT PROVIDED)
BLK (-)
RED (+)
9VDC
+
-
TRIGGER
(NOT PROVIDED)
BLK (-)
RED (+)
9VDC
+
-
TRIGGER
(NOT PROVIDED)
Control with Power Supply
-Not supervised
- Alarm on close
- Cannot use battery
turn off Low Battery Detect
RED (+)
9VDC
-
+
BLK (-)
STROBE & SIREN
TRIGGER
(NOT PROVIDED)
RED (+)
9VDC
-
+
BLK (-)
TRIGGER
(NOT PROVIDED)
RED (+)
9VDC
-
+
BLK (-)
TRIGGER
(NOT PROVIDED)
Power Supply Plus Battery
- Supervised trigger
- Alarm on open trigger
- Low battery alert
(Turn off if battery not used)
RED (+)
9VDC
BLK (-)
STROBE & SIREN
TRIGGER
(NOT PROVIDED)
RED (+)
9VDC
BLK (-)
TRIGGER
(NOT PROVIDED)
RED (+)
9VDC
BLK (-)
TRIGGER
(NOT PROVIDED)
Battery Only
- Supervised trigger
- Alarm on open
trigger
- Low battery alert
INSTALLATION OF STI-SA5500 SELECT ALERT SIREN/STROBE
All specifications and information shown were current as of publication and are subject to change without notice.
SA5500IS DEC2020
SIREN
STROBE
S1 ALARM TONES
1 2 3 4 5 FUNCTION
* 1 1 1 1 1 1800Hz - 3300Hz @ 150ms
O 1 1 1 1 500Hz - 1200Hz, 0.5s/ 0.5s OFF x 3/1.5s OFF (AS1670 EVACUATION)
1 O 1 1 1 520Hz, 0.5s / 0.5s OFF x 3/1.5s OFF (FIRE)
O O 1 1 1 1200Hz - 500Hz @ 1Hz (DIN 33 404)
1 1 O 1 1 500Hz - 1200Hz, 3.75s ON / 0.25s OFF (AS2220)
O 1 O 1 1 550Hz/440Hz @ 0.5 Hz
1 O O 1 1 970Hz, 0.5s/ 630Hz, 0.5s
O O O 1 1 800Hz / 1000Hz 0.5s each (1Hz)
1 1 1 O 1 1500Hz - 2700Hz @ 3Hz
O 1 1 O 1 800Hz / 970Hz @2Hz
1 O 1 O 1 800Hz, 0.25s ON/ 1s OFF
O O 1 O 1 2400Hz - 2900Hz @ 9 Hz
1 1 O O 1 750Hz
O 1 O O 1 970Hz
1 O O O 1 970Hz, 1s OFF/1s ON
O O O O 1 500Hz - 1200Hz, 3.5s ON/ 0.5s OFF (NEN 2575:2000 DUTCH SLOW WHOOP)
1 1 1 1 O 800Hz - 970Hz @1Hz
O 1 1 1 O 1000-2500Hz, 0.5s/ 0.5s OFF x 3/1.5s OFF (AS1670 EVACUATION)
1 O 1 1 O 2850Hz, 0.5s ON/0.5s OFF x 3/1.5s OFF (ISO 8201)
O O 1 1 O 660Hz 1.8s ON/1.8s OFF
1 1 O 1 O 500Hz - 1200Hz @ 0.33Hz
O 1 O 1 O 250Hz - 1200Hz @ 12Hz
1 O O 1 O 2400Hz
O O O 1 O 800Hz - 970Hz @ 9Hz
1 1 1 O O 510Hz, 0.25s/ 610Hz, 0.25s
O 1 1 O O 550Hz, 0.7s/1000Hz, 0.33s
1 O 1 O O 660Hz 0.15s ON/0.15s OFF
O O 1 O O 800Hz - 970Hz @ 3Hz
1 1 O O O 420Hz 0.625s ON/0.625s OFF (AUSTRALIA AS1670 ALERT TONE)
O 1 O O O 554Hz, 0.1s/440Hz, 0.4s (AFNOR NF S 32 001)
1 O O O O 970Hz, 0.5s ON/0.5s OFF x 3/1.5s OFF (ISO 8201)
O O O O O 2400Hz - 2900Hz @ 3 Hz
S1 VOLUME
6 FUNCTION
* 1 High volume
0 Low volume
1 2 3 4 5 6
1 ON
0 OFF
*Default Settings
STROBE ONLY STROBE ONLY STROBE ONLY
SIREN ONLY SIREN ONLY SIREN ONLY
BLU YEL
BLU YEL
BLU YEL BLU YEL BLU YEL
BLU YEL BLU YEL
BLU YEL BLU YEL